• Title/Summary/Keyword: pre-cooling

Search Result 217, Processing Time 0.025 seconds

A study for the utilization of ready-prepared foodservice system concept to the Korean hospital foodservice operations (병원급식에서 Ready-Prepared Foodservice System 이용에 관한 연구)

  • Kim, Ji-Young;Kim, Hah-Young
    • Korean journal of food and cookery science
    • /
    • v.2 no.2
    • /
    • pp.21-31
    • /
    • 1986
  • Here is a research on hospital foodservice system, when korea traditional food of pyeon yuk and bin dae deok were used by ready-prepared foodservice system, it was estimated the preservations of microbiological quality and sensory quality. All data collection was replicated three times. The results were as following; 1. In time and temperature data, two menu items were needed internal temperature below $7^{\circ}C$ in a cooling stage, and in the case of cook/chill storage, the days were shortened within weeks, and the holding time must be possiblely minimized. Finally foods were served sanitary. 2. In view of microbiological safety, in the case of cook/chill storage as $0{\sim}4^{\circ}C$ the days must be shortened within 2 weeks and its was possible to store until 6 weeks in $-20{\sim}-23.3^{\circ}C$. So to preserve pre-cooked food longly, it was effective to freeze them quickly by using vacuum package and to reheat them by a microwave oven before serving and to serve lastly in microbiological quality. 3. Hospital ready-prepared foodservice system with food storage in plastic bags, biochemical test of C. Perfingens C. botulinum and Salmonella were not detected. 4. By using of a microwave oven, it had effects of thawing, reheating and sterilizing of chilled and frozen foods in a short time. 5. Sensory evaluations were made by a 10-member panel using five scoring tests. Because sensory of quality was lowered in the case of chilled storage, it was possible to serve foods within 2 weeks. Texture and aroma were preserved by cook/frozen system and usually there was no significance from 4 weeks until 6 weeks, but considering of the objects, it was good to store until 4 weeks in sensory quality.

  • PDF

A Study on the Improvement of Hydrogen Tank Fueling Performance Using MC Methods (MC 기법을 이용한 수소 탱크 충전 성능 향상에 관한 연구)

  • JIAH CHOI;SANGWON JI;JISEONG JANG
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.5
    • /
    • pp.447-455
    • /
    • 2023
  • SAE J2601, hydrogen fueling protocols, proposes two charging methods. The first is the table-based fueling protocol, and the second is the MC formula-based fueling protocol. Among them, MC formula-based fueling protocol calculates and supplies the target pressure and pressure ramp rate (PRR) using the pre-cooling temperature of the hydrogen and the physical parameters of the tank in the vehicle. The coefficient of the MC formula for deriving MC varies depending on the physical parameters of the tank in the vehicle. However, most studies use the MC coefficient derived from SAE J2601 as it is, despite the difference in the physical parameters of the tank applied to the study and the tank used to derive the MC coefficient from SAE J2601. In this study, the MC coefficient was derived by applying the hydrogen tank currently used, and the difference with the fueling performance using the MC coefficient proposed in SAE J2601 was verified. In addition, the difference was confirmed by comparing and analyzing the fueling performance of the table-based method currently used in hydrogen fueling stations and the MC formula-based method using MC coefficient derived in this study.

A Study on the Construction of the Gas Conversion Process System for a Pilot Plant Using a Small-scale Hydrogen Liquefaction System (소규모 수소 액화 시스템을 활용한 파일럿 플랜트의 기체 전환 공정 시스템 구축에 관한 연구)

  • YOUNG MIN SEO;HYUN WOO NOH;TAE HYUNG KOO;ROCK KIL KO;DONG WOO HA
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.4
    • /
    • pp.353-362
    • /
    • 2024
  • In this study, several studies were conducted on the construction of gas conversion process system for a pilot plant using a small-scale hydrogen liquefaction system. The pilot plant considered in this study includes a liquefier, a storage tank, an evaporator, a gas booster, and a gas storage tank. First, the suspected leak area of the container was checked using the sprayed method of helium gas. The small-scale hydrogen liquefaction system was designed based on the analysis results of the pre-cooling system and the liquefaction system. Additionally, the program was developed to maintain pressure within vessel for an automatic production of liquid hydrogen. The evaporator for liquid hydrogen was manufactured based on the designed analysis data, and the pollution of gas in the vessel was analyzed through a gas recovery line system.

Effect of gas condition on graphene synthesized by rapid thermal chemical vapor deposition

  • Yang Soo Lee;Dong In Jeong;Yeojoon Yoon;Byeongmin Baek;Hyung Wook Choi;Seok Bin Kwon;Do Hun Kim;Young Joon Hong;Won Kyu Park;Young Hyun Song;Bong Kyun Kang;Dae Ho Yoon;Woo Seok Yang
    • Journal of Ceramic Processing Research
    • /
    • v.21
    • /
    • pp.47-52
    • /
    • 2020
  • Graphene was synthesized using rapid thermal chemical vapor deposition (RT-CVD) equipment designed to produce largearea graphene at high speed. The effects of methane (CH4), argon (Ar), and hydrogen (H2) gases were investigated between 800 ℃ and 1,000 ℃ during heating and cooling in the graphene synthesis process. The findings reveal that multilayer domains increased due to hydrogen pretreatment with increase in temperature. Furthermore, when pretreated with the same gas, it was confirmed that the post-argon-treated sample cooled from 1,000 ℃ to 800 ℃ had a higher ID/IG value than that of the other samples. This result was consistent with the sheet resistance properties of graphene. The sample prepared in methane atmosphere maintained during both the pre-treatment and post-treatment demonstrated the lowest sheet resistance of 787.49 Ω/sq. Maintaining the methane gas atmosphere in the high-temperature region during graphene synthesis by RT-CVD reduced the defects and improved the electrical property.

Genetic Environments of Hydrothermal Vein Deposits in the Pacitan District, East Java, Indonesia (인도네시아 동부자바 빠찌딴(Pacitan) 광화대 열수 맥상 광상의 성인 연구)

  • Choi, Seon-Gyu;So, Chil-Sup;Choi, Sang-Hoon;Han, Jin-Kyun
    • Economic and Environmental Geology
    • /
    • v.28 no.2
    • /
    • pp.109-121
    • /
    • 1995
  • The hydrothermal vein type deposits which comprise the Kasihan, Jompong and Gempol mineralized areas are primarily copper and zinc deposits, but they are also associated with lead and/or gold mineralization. The deposits occur within the Tertiary sedimentary and volcanic rocks in the Southern Mountain zone of the eastern Java island, Indonesia. Mineralization can be separated into two or three distinct stages (pre-and/or post- ore mineralization stages and main ore mineralization stage) which took place mainly along pre-existing fault breccia zones. The main phase of mineralization (the main ore stage) can be usually classified into three substages (early, middle and late) according to ore mineral assemblages, paragenesis, textures and their chemical compositions. Ore mineralogy and paragenesis of the three areas in the district are different from each other. Pyrite, pyrrhotite (/arsenopyrite), iron-rich (up to 20.5 mole % FeS) sphalerite and (Cu-)Pb-Bi sulfosalts are characteristic of the deposits in the Kasihan (/Jompong) area. On the other hand, pyrite + hematite + magnetite + iron-poor (2.7 to 3.6 mole % FeS) sphalerite assemblage is restricted to the Gempol area. Fluid inclusion data suggest that fluids of the main ore stage evolved from initial high temperatures (near $350^{\circ}C$) to later lower temperatures (near $200^{\circ}C$) with salinities ranging from 0.8 to 10.1 equiv. wt. percent NaCl. Each area represents a separate hydrothermal system: the mineralization at Kasihan and Jompong were largely due to early fluid boiling coupled with later cooling and dilution, whereas the mineralization at Gempol was mainly resulted from cooling and dilution by an influx of cooler meteoric waters. Fluid inclusion evidence of boiling indicates that pressures of ${\geq}95$ to 255 bars (${\geq}95$ bars for the Gempol area: $\approx$ 120 to 170 bars for the Jompong area: $\approx$ 140 to 255 bars for the Kasihan area) during portions of main ore stage mineralization. Equilibrium thermodynamic interpretation indicates that the evolution trends of the temperature versus fS2 variation of ore stage fluids in the Pacitan district follow two fashions: ore fluids at Kasihan and Jompong changed from the pyrite-pyrrhotite sulfidation stage towards pyritehematite- magnetite state, whereas those at Gempol evolved nearly along pyrite-hematite-magnetite reaction curve with decreasing temperature. The sulfur isotope compositions of sulfide minerals are consistent with an igneous source of sulfur with a ${\delta}^{34}S_{{\Sigma}s}$ value of about 3.3 per mil. The oxygen and hydrogen isotopic compositions of the fluids in each area indicate a progressive shift from the dominance of highly exchanged meteoric water at early hydrothermal systems towards an un- or less-exchanged meteoric water at later hydrothermal systems.

  • PDF

Role of Catecholamines in Ventricular Fibrillation (Catecholamines에 관(關)하여 -제4편(第四編) : 심실전동발생(心室顫動發生)에 있어서의 catecholamines의 의의(意義)-)

  • Lee, Woo-Choo
    • The Korean Journal of Pharmacology
    • /
    • v.19 no.1
    • /
    • pp.15-35
    • /
    • 1983
  • Although it has been well known that ventricular fibrillation is the most important complication during hypothermia, much investigation has failed to show the exact nature of the etiology of ventricular fibrillation. Recently, there has been considerable research on the relationship between sympathetic activity and ventricular fibrillation under hypothermia. Cardiac muscle normally contains a certain amount of norepinephrine and the dramatic effect of this catecholamines on the cardiac muscle is well documented. It is, therefore, conceivable that cardiac catecholamines might exert an influence on the susceptibility of heart muscle to tachycardia, ventricular fibrillation and arrhythmia, under hypothermia. Hypothermia itself is stress enough to increase tonus of sympatheticoadrenal system. The normal heart is supplied by an autonomic innervation and is subjected to action of circulating catecholamines which may be released from the heart. If the reaction of the heart associated with a variable amount of cardiac catecholamines is. permitted to occur in the induction of hypothermia, the action of this agent on the heart has not to be differentiated from the direct effects of cooling. The studies presented in this paper were designed to provide further information about the cardio-physiological effects of reduced body temperature, with special reference to the role of catecholamines in ventricular fibrillation. Healthy cats, weighing about 3 kg, were anesthetized with pentobarbital(30 mg/kg) intraperitoneally. The trachea was intubated and the endotracheal tube was connected to a C.F. Palmer type A.C. respirator. Hypothermia was induced by immersing the cat into a ice water tub and the rate of body temperature lowering was $1^{\circ}C$ per 5 to 8 min. Esophageal temperature and ECG (Lead II) were simultaneously monitored. In some cases the blood pH and serum sodium and potassium were estimated before the experiment. After the experiment the animals were killed and the hearts were excised. The catecholamines content of the cardiac muscle was measured by the method of Shore and Olin (1958). The results obtained are summarized as follows. 1) In control animal the heart rate was slowed as the temperature fell and the average pulse rates of eight animals were read 94/min at $31^{\circ}C$, 70/min at $27^{\circ}C$ and 43/min at $23^{\circ}C$ if esophageal temperature. Ventricular fibrillation was occurred with no exception at a mean temperature of $20.3^{\circ}C(21-l9^{\circ}C)$. The electrocardiogram revealed abnormal P waves in each progressive cooling of the heart. there was, ultimately, a marked delay in the P-R interval, QRS complex and Q-T interval. Inversion of the T waves was characteristic of all animals. The catecholamines content of the heart muscle excised immediately after the occurrence of ventricular fibrillation was about thirty percent lower than that of the pre-hypothermic heart, that is, $1.0\;{\mu}g/g$ wet weight compared to the prehypothermic value of $1.41\;{\mu}g/g$ wet weight. The changes of blood pH, serum sodium and potassium concentration were not remarkable. 2) By the adrenergic receptor blocking agent, DCI(2-3 mg/kg), given intramuscularly thirty minutes before hypothermia, ventricular fibrillation did not occur in one of five animals when their body temperature was reduced even to $16^{\circ}C$. These animals succumbed at that low temperature, and the changes of heart rate and loss of myocardial catecholamines after hypothermia were similar to those of normal animals. The actual effect of DCI preventing the ventricular fibrillation is not predictable. 3) Administration of reserpine(1 mg/kg, i.m.) 24 hours Prior to hypothermia disclosed reduced incidence of ventricular fibrillation, that is, six of the nine animals went into fibrillation at an average temperature of $19.6^{\circ}C$. By reserpine myocardial catecholamines content dropped to $0.045\;{\mu}g/g$ wet weight. 4) Bretylium pretreatment(20 mg/kg, i.m.), which blocks the release of catecholamines, Prevented the ventricular fibrillation under hypothermia in four of the eight cats. The pulse rate, however, was approximately the same as control and in some cases was rather slower. 5) Six cats treated with norepinephrine(2 mg/kg, i.m.) or DOPA(50 mg/kg) and tranylcypromine(10 mg/kg), which tab teen proved to cause significant increase in the catecholamines content of the heart muscle, showed ventricular fibrillation in all animals under hypothermia at average temperature of $21.6^{\circ}C$ and the pulse rate increased remarkably as compared with that of normal. Catecholamines content of cardiac muscle of these animals markedly decreased after hypothermia but higher than control animals. 6) The functional refractory periods of isolated rabbit atria, determined by the paired stimulus technique, was markedly shortened by administration of epinephrine, norepinephrine and isoproterenol. 7) Adrenergic beta-blocking agents, such as pronethalol, propranolol and sotalol(MJ-1999), inhibited completely the shortening of refractory period induced by norepinephrine. 8) Pretreatment with either phenoxftenbamine or phentolamine, an adrenergic alphatlocking agent, did not modify the decrease in refractory period induced by norepinephrine. From the above experiment it is possible to conclude that catecholamines play an important role in producing ventricular fibrillation under hypothermia. The shortening of the refractorf period of cardiac muscle induced by catecholamines mar be considered as a partial factor in producing ventriculr fibrillaton and to be mediated by beta-adrenergic receptor.

  • PDF

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

Influence of the nitrogen gas addition in the Ar shielding gas on the erosion-corrosion of tube-to-tube sheet welds of hyper duplex stainless steel (질소 보호 가스 첨가가 하이퍼 듀플렉스 스테인리스 밀봉용접재의 마모부식 저항성에 미치는 영향)

  • Kim, Hye-Jin;Jeon, Soon-Hyeok;Kim, Soon-Tae;Lee, In-Sung;Park, Yong-Soo
    • Corrosion Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.70-80
    • /
    • 2014
  • Duplex stainless steels with nearly equal fraction of the ferrite(${\alpha}$) phase and austenite(${\gamma}$) phase have been increasingly used for various applications such as power plants, desalination facilities due to their high resistance to corrosion, good weldability, and excellent mechanical properties. Hyper duplex stainless steel (HDSS) is defined as the future duplex stainless steel with a pitting resistance equivalent (PRE=wt.%Cr+3.3(wt.%Mo+0.5wt.%W)+30wt.%N) of above 50. However, when HDSS is welded with gas tungsten arc (GTA), incorporation of nitrogen in the Ar shielding gas are very important because the volume fraction of ${\alpha}$-phase and ${\gamma}$-phase is changed and harmful secondary phases can be formed in the welded zone. In other words, the balance of corrosion resistance between two phases and reduction of $Cr_2N$ are the key points of this study. The primary results of this study are as follows. The addition of $N_2$ to the Ar shielding gas provides phase balance under weld-cooling conditions and increases the transformation temperature of the ${\alpha}$-phase to ${\gamma}$-phase, increasing the fraction of ${\gamma}$-phase as well as decreasing the precipitation of $Cr_2N$. In the anodic polarization test, the addition of nitrogen gas in the Ar shielding gas improved values of the electrochemical parameters, compared to the Pure Ar. Also, in the erosion-corrosion test, the HDSS welded with shielding gas containing $N_2$ decreased the weight loss, compared to HDSS welded with the Ar pure gas. This result showed the resistance of erosion-corrosion was increased due to increasing the fraction of ${\gamma}$-phase and the stability of passive film according to the addition $N_2$ gas to the Ar shielding gas. As a result, the addition of nitrogen gas to the shielding gas improved the resistance of erosion-corrosion.

Petrology of the Chaeyaksan basaltic rocks and application of hornblende geobarometer (채약산 현무암질암류의 암석학적인 특징 및 각섬석 지질압력계의 적용)

  • 김상욱;황상구;양판석;이윤종;고인석
    • The Journal of the Petrological Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.92-105
    • /
    • 1999
  • The Cretaceous Chaeyaksan basaltic rocks consist mainly of basaltic tuffs intercalating three layers of basalt. Stratigraphically, the rocks are located between the upper Songnaedong Formation and the lower Geoncheonri Formation and contain plagioclase, augite, hornblende, and a few olivine phenocrysts. Geochemically, they show calc-alkaline characteristics in some immobile element content, but show the alkaline suite feature in the mobile major element composition. The basalts are widely spilitized but some of them is altered to shoshonitic rocks with more calcic plagioclase, calcite, and chlorite, and adularia veinlets are common in the rocks. It is supposed that the post-eruption alteration of the rocks is done through alkali-replacement by hydrothermal solution or vapor rather than by low grade regional metamorphism. It is considered that A1 in hornblende will be available for estimating the pressure of the pre-eruption magma in the reservoir although the plagioclase of the rocks are highly albitized. The crystallization pressure was calculated as 5.7Kb by the equation of Johnson and Rutherford(l989) incorporating of the effect of overestimate of .41T in hornblende in the case of quartz-free rocks. Application of the estimated temperature, pressure and the constituent of phenocrysts of the rocks to the experimental P-T phase diagram for basalts established by Green(1982) indicates the crystallization course and succession of growth of the phenocrysts during of rising and cooling of the magma reservoir; augite + augite and olivine + augite, olivine, and hornblende -+ augite and hornblende+ augite, hornblende, and plagioclase. Such evolution course of the magma may include crystal fractionation by the phenocrysts crystallization and contamination by country rock in lower crust.

  • PDF

Development of Smart Switchgear for Versatile Ventilation Garments: Optimum Diameter and Voltage Application Unit Time of One-way Shape Memory Alloy Wire for a Bi-directional Actuator (가변 통기성 의복을 위한 스마트 개폐장치 개발: 양방향 작동 액추에이터 제작을 위한 일방향 형상기억합금 와이어의 최적 직경 및 전압인가 단위시간의 도출)

  • Kim, Sanggu;Kim, Minsung;Yoo, Shinjung
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2018
  • The study figured out the operational conditions of a two-way movement actuator made of one-way shape memory alloy (OWSMA) for versatile ventilation intelligent garments. To develop a low-power actuator that consumes energy only when a garment changes its form such as opening and closing, multiple channels of OWSMA were used, and optimum diameter of the wires was examined. For the switch device, optimum voltage application unit time was determined. Optimum diameter of OWSMA wire was determined by applying 3.7V to the pre-determined candidate diameters, which demonstrated two-way operation in previous studies. In order to evaluate the optimum voltage application time, the internal diameter of the actuator was measured while increasing and decreasing by 50 ms from the unit time of voltage application. Delay time under two-way operation of the actuator was measured to minimize interference caused by heat between channels. Power of 3.7V was applied to OWSMA for assessment of optimal time, and the whole process from heating to cooling was video-recorded with a thermal image camera to determine the point of time at which the temperature of OWSMA wire dropped below the phase transformation temperature. The results showed that $0.4{\Phi}$ was the most suitable diameter, and the optimum unit time of voltage applied to open and close the actuator was 4100ms. It was also shown that the delay time should be more than 1.8 seconds between two-way operations of the actuator.