• Title/Summary/Keyword: practical use effect

Search Result 928, Processing Time 0.028 seconds

Finite Element Based Stress Concentration Factors for Pipes with Local Wall Thinning (유한요소해석을 이용한 국부 감육배관에 대한 응력집중계수 제시)

  • Son, Beom-Goo;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.1014-1020
    • /
    • 2004
  • The present work complies the elastic stress concentration factor for a pipe with local wall thinning, based on detailed three-dimensional elastic FE analysis. To cover practically interesting cases, a wide range of pipe and defect geometries are considered, and both internal pressure and global bending are considered. Resulting values of stress concentration factors are tabulated for practical use, and the effect of relevant parameters such as pipe and defect geometries on stress concentration factors are discussed. The present results would provide valuable information to estimate fatigue damage of the pipe with local wall thinning under high cycle fatigue.

Reliability analysis of a mechanically stabilized earth wall using the surface response methodology optimized by a genetic algorithm

  • Hamrouni, Adam;Dias, Daniel;Sbartai, Badreddine
    • Geomechanics and Engineering
    • /
    • v.15 no.4
    • /
    • pp.937-945
    • /
    • 2018
  • A probabilistic study of a reinforced earth wall in a frictional soil using the surface response methodology (RSM) is presented. A deterministic model based on numerical simulations is used (Abdelouhab et al. 2011, 2012b) and the serviceability limit state (SLS) is considered in the analysis. The model computes the maximum horizontal displacement of the wall. The response surface methodology is utilized for the assessment of the Hasofer-Lind reliability index and is optimized by the use of a genetic algorithm. The soil friction angle and the unit weight are considered as random variables while studying the SLS. The assumption of non-normal distribution for the random variables has an important effect on the reliability index for the practical range of values of the wall horizontal displacement.

An egornomic study on visual accomodation and pupil functions during the observation of binocular 3-D images (이안식 입체영상 관찰자 조절과 공동기능에 관한 인간공학적인 연구)

  • Cho, Am
    • Journal of the Ergonomics Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.3-12
    • /
    • 1992
  • To put the binocular 3-D images system into practical use, it is required to investigate the relationship between the system and men and to make ergonomic evaluation of the system. In this study, we perform a comparative analysis of the changes in the accommodation and pupil functions before and afer observing binocular 3-D images a sthe visual distance varies. From the experiment, we obtained the following results: (1) The discordance in the distance informatioons on the accommodation and pupil functions when obwerving 3-D images is compensated by the miosis and altering the focal depth. (2) From the consideration of the effect of the visual distance condition on the visual functions, it is thoughth that the visual functions are stabilized at the dark focus in the sense that the changes in the tension and relazation afer observing the 3-D images are minimized.

  • PDF

PI-based Feedforward Control for Driving Mode Transformation of Rescue Robot capable of Obstacle Overcoming (장애물 극복이 가능한 구조로봇의 주행모드 변형을 위한 PI-based Feedforward 제어)

  • Jeong, Hae-Kwan;Kang, Hyun-Suk;Kwak, Yoon-Keun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.5
    • /
    • pp.489-495
    • /
    • 2008
  • This paper offers a practical control scheme for driving mode transformation of a rescue robot already developed. The rescue robot, VSTR(Variable Single-Tracked Robot), has two driving modes, so can traverse untidy terrain and overcome obstacles such as stairs easily by use of timely driving mode transformation. Classical PI control scheme was used firstly for driving mode transformation, but stationary phenomenon, which might have a bad effect on the performance in real situation, came into existence. Therefore, we suggest a new controller, PI-based feedforward controller, which should be a good alternative for the problem, and compare it with other nonlinear control scheme.

Characteristics of long-term operated Electrostatic airclean filter for air-conditioner (장시간사용(長時間使用)한 공조용(空調用) 전기집진(電氣集塵)필터의 특성(特性))

  • Hong, Young-Ki;Kang, Kwang-Ok;Lee, Sung-Hwa;Son, Sang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.453-455
    • /
    • 1995
  • In electrostatic airclean filter, the collection efficiency defends on particle charge in the ionizer section. The effect of electrostatic airclean filter condition (deposition of dust, variation of corona discharge current) on corona discharge characteristics was well studied. However, it seems not to be studied on corona discharge characteristics of electrostatic airclean filter respect to contaminated electrode which is caused by practical use. In this paper, Long-term(60days) effects are studied experimentally by two methods. The one is ozone concentration, the other is collection efficiency. Generation of ozone level was increased but collection efficiency was slightly reduced in long-term used electrostatic airclean filter.

  • PDF

A Study on Substation equipment Loss Actual State Investigation and Analysis of Office Building (건물의 변전설비 손실 실태조사 및 분석에 관한 연구)

  • 유현재
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.3
    • /
    • pp.57-62
    • /
    • 1992
  • In this paper, the reasonable design standard of Demand Factor for large office buildings is introduced that was made by the statistical way considering actual conditions, such as investigated electrical equipment capacity, electrical power consumption, etc. The results are as follows. 1) It is shown that th saving of electrical equipment investment, the decrease of power loss, the improvement of facilities utilization and the decrease of electrical power rates can be contributed by the application of the design standard. 2) The effect of reduction is showed to confirm the practical use of the proposed reference Demand Factor, and also, it is believed that this proposed reference Demand Factor will be useful in electrical equipment operation and planning.

  • PDF

AHP Usage Pattern As a GDSS Toward the Various Task Types: IS Theory Testing (다양한 문제형태에 대한 AHP의 GDSS사용특성: IS이론을 중심으로)

  • 손달호
    • Korean Management Science Review
    • /
    • v.13 no.3
    • /
    • pp.115-128
    • /
    • 1996
  • System usage, the utilization of information technology(IT) by individuals, groups or organizations, is a core variable in IS research. Indeed, there is widespread agreement among researchers that system usage is the primary variable through which IT affects white collar performance because it is a requisite, albeit insufficient, for deriving the benefits of IT. Furthermore, system usage has a notable practical value for managers interested in evaluating the impact of IT. Despite the number of studies of targeted at explaining system usage, there are more areas which required for the verification of system usage. The purpose of this paper is to address, using the Technological Acceptance Model (TAM), the usage pattern of AHP toward the various task in group decision (GD). The result showed that, for the all of the task types, perceived usage (PU) has more effect than perceived ease-of-use(PEU) on the AHP usage. However, more researches are required to generalize the result of this study.

  • PDF

Estimation of Tension Forces of Stay Cables (인장 케이블의 장력 추정기법에 관한 연구)

  • Kim, Nam-Sik;Jeong, Woon;Seo, Ju-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.121-126
    • /
    • 2002
  • In a recent construction industry, cable supported structures such as a cable-stayed bridge or space stadium have been increasingly constructed. Generally the stay cables as a critical member should be adjusted to be satisfied with the design tension forces. In this purpose, a vibration method has been applied to estimate the tension forces exerted to the existing stay cables. In this study, cable vibration tests were carried out to estimate the cable tension forces comparing with theoretical and practical formulas. From the measured frequencies obtained from free vibration and impulsive tests, the accuracy of 1he estimated tension forces is confirmed according to use only the first single mode or higher multiple modes.

  • PDF

Emulsion rheology and properties of polymerized high internal phase emulsions

  • Lee, Seong-Jae
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.4
    • /
    • pp.183-189
    • /
    • 2006
  • High internal phase emulsions are highly concentrated emulsion systems consisting of a large volume of dispersed phase above 0.74. The rheological properties of high internal phase water-in-oil emulsions were measured conducting steady shear, oscillatory shear and creep/recovery experiments. It was found that the yield stress is inversely proportional to the drop size with the exponent of values between 1 and 2. Since the oil phase contains monomeric species, microcellular foams can easily be prepared from high internal phase emulsions. In this study, the microcellular foams combining a couple of thickeners into the conventional formulation of styrene and water system were investigated to understand the effect of viscosity ratio on cell size. Cell size variation on thickener concentration could be explained by a dimensional analysis between the capillary number and the viscosity ratio. Compression properties of foam are important end use properties in many practical applications. Crush strength and Young's modulus of microcellular foams polymerized from high internal phase emulsions were measured and compared from compression tests. Of the foams tested in this study, the foam prepared from the organoclay having reactive group as an oil phase thickener showed outstanding compression properties.

Evaluation of Continuously and Intermittently Aerated Hog Manure Compost Stability in a Pilot-scale Bin Composting System (파일럿 규모 빈 퇴비화 시스템에서 연속 및 간헐 통기 돈분 퇴비의 안정도 평가)

  • Hong, Ji-Hyung
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 1998
  • Compost stability represents the state of microbiological activity and measurements of respiration either through $CO_2$ evolution or $O_2$ uptake should provide the best indication of this state. Hog manure amended with sawdust was composted in a pilot-scale reactor vessels using continuous and intermittent aeration for 3 weeks. In this study we evaluated the $CO_2$ respiration rate effect of aeration method on the reduction of $CO_2$ evolution, and investigated the stability of fresh and finished compost for plant growth. The intermittently aerated composting is a practical proposition for a very stable compost making. The $CO_2$ respiration rate in the fresh and finished compost during intermittently aerated composting was maintained from 0.3 to 1.4 and was good for use in horticulture, while the continuously aerated composting was 7 to 23 and needed more time for compost curing.

  • PDF