• Title/Summary/Keyword: power-sum

Search Result 529, Processing Time 0.02 seconds

A Near Optimal Linear Preceding for Multiuser MIMO Throughput Maximization (다중 안테나 다중 사용자 환경에서 최대 전송율에 근접하는 선형 precoding 기법)

  • Jang, Seung-Hun;Yang, Jang-Hoon;Jang, Kyu-Hwan;Kim, Dong-Ku
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.4C
    • /
    • pp.414-423
    • /
    • 2009
  • This paper considers a linear precoding scheme that achieves near optimal sum rate. While the minimum mean square error (MMSE) precoding provides the better MSE performance at all signal-to-noise ratio (SNR) than the zero forcing (ZF) precoding, its sum rate shows superior performance to ZF precoding at low SNR but inferior performance to ZF precoding at high SNR, From this observation, we first propose a near optimal linear precoding scheme in terms of sum rate. The resulting precoding scheme regularizes ZF precoding to maximize the sum rate, resulting in better sum rate performance than both ZF precoding and MMSE precoding at all SNR ranges. To find regularization parameters, we propose a simple algorithm such that locally maximal sum rate is achieved. As a low complexity alternative, we also propose a simple power re-allocation scheme in the conventional regularized channel inversion scheme. Finally, the proposed scheme is tested under the presence of channel estimation error. By simulation, we show that the proposed scheme can maintain the performance gain in the presence of channel estimation error and is robust to the channel estimation error.

Estimating excess post-exercise oxygen consumption using multiple linear regression in healthy Korean adults: a pilot study

  • Jung, Won-Sang;Park, Hun-Young;Kim, Sung-Woo;Kim, Jisu;Hwang, Hyejung;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.1
    • /
    • pp.35-41
    • /
    • 2021
  • [Purpose] This pilot study aimed to develop a regression model to estimate the excess post-exercise oxygen consumption (EPOC) of Korean adults using various easy-to-measure dependent variables. [Methods] The EPOC and dependent variables for its estimation (e.g., sex, age, height, weight, body mass index, fat-free mass [FFM], fat mass, % body fat, and heart rate_sum [HR_sum]) were measured in 75 healthy adults (31 males, 44 females). Statistical analysis was performed to develop an EPOC estimation regression model using the stepwise regression method. [Results] We confirmed that FFM and HR_sum were important variables in the EPOC regression models of various exercise types. The explanatory power and standard errors of estimates (SEE) for EPOC of each exercise type were as follows: the continuous exercise (CEx) regression model was 86.3% (R2) and 85.9% (adjusted R2), and the mean SEE was 11.73 kcal, interval exercise (IEx) regression model was 83.1% (R2) and 82.6% (adjusted R2), while the mean SEE was 13.68 kcal, and the accumulation of short-duration exercise (AEx) regression models was 91.3% (R2) and 91.0% (adjusted R2), while the mean SEE was 27.71 kcal. There was no significant difference between the measured EPOC using a metabolic gas analyzer and the predicted EPOC for each exercise type. [Conclusion] This pilot study developed a regression model to estimate EPOC in healthy Korean adults. The regression model was as follows: CEx = -37.128 + 1.003 × (FFM) + 0.016 × (HR_sum), IEx = -49.265 + 1.442 × (FFM) + 0.013 × (HR_sum), and AEx = -100.942 + 2.209 × (FFM) + 0.020 × (HR_sum).

Two-Way Hybrid Power-Line and Wireless Amplify-and-Forward Relay Communication Systems

  • Asiedu, Derek Kwaku Pobi;Ahiadormey, Roger Kwao;Shin, Suho;Lee, Kyoung-Jae
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.9 no.1
    • /
    • pp.25-37
    • /
    • 2019
  • Power-line communication (PLC) has influenced smart grid development. In addition, PLC has also been instrumental in current research on internet-of-things (IoT). Due to the implementation of PLC in smart grid and IoT environments, strides have been made in PLC and its combination with the wireless system to form a hybrid communication system. Also, PLC has evolved from a single-input-single-output (SISO) configuration to multiple-input-multiple-output (MIMO) configuration system, and from a point-to-point communication system to cooperative communication systems. In this work, we extend a MIMO wireless two-way amplify-and-forward (AF) cooperative communication system to a hybrid PLC and wireless (PLC/W) system configuration. We then maximize the weighted sum-rate for the hybrid PLC/W by optimizing the precoders at each node within the hybrid PLC/W system. The sum-rate problem was found to be non-convex, therefore, an iterative algorithm is used to find the optimal precoders that locally maximize the system sum-rate. For our simulation results, we compare our proposed hybrid PLC/W configuration to a PLC only and wireless only configuration at each node. Due to an improvement in system diversity, the hybrid PLC/W configuration outperformed the PLC only and wireless only system configurations in all simulation results presented in this paper.

Power Allocation and Subcarrier Assignment for Joint Delivery of Unicast and Broadcast Transmissions in OFDM Systems

  • Lee, Deokhui;So, Jaewoo;Lee, Seong Ro
    • Journal of Communications and Networks
    • /
    • v.18 no.3
    • /
    • pp.375-386
    • /
    • 2016
  • Most existing studies on broadcast services in orthogonal frequency division multiplexing (OFDM) systems have focused on how to allocate the transmission power to the subcarriers. However, because a broadcasting system must guarantee quality of service to all users, the performance of the broadcast service dominantly depends on the channel state of the user who has the lowest received signal-to-noise ratio among users. To reduce the effect of the worst user on the system performance, we propose a joint delivery scheme of unicast and broadcast transmissions in OFDM systems with broadcast and unicast best-effort users. In the proposed joint delivery scheme, the BS delivers the broadcast information using both the broadcast and unicast subcarriers at the same time in order to improve the performance of the broadcast service. The object of the proposed scheme is to minimize the outage probability of the broadcast service while maximizing the sum-rate of best-effort users. For the proposed joint delivery scheme, we develop an adaptive power and subcarrier allocation algorithm under the constraint of total transmission power. This paper shows that the optimal power allocation over each subcarrier in the proposed scheme has a multi-level water filling form. Because the power allocation and the subcarrier assignment problems should be jointly solved, we develop an iterative algorithm to find the optimal solution. Numerical results show that the proposed joint delivery scheme with adaptive power and subcarrier allocation outperforms the conventional scheme in terms of the outage probability of the broadcast service and the sum-rate of best-effort users.

Design of High Gain Low Noise Amplifier (2.4GHz 고이득 저잡음 증폭기 설계)

  • 손주호;최석우;윤창훈;김동용
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.309-312
    • /
    • 2002
  • In this paper, we discuss the design of high gain low noise amplifier by using the 0.2sum CMOS technology. A cascode inverter is adopted to implement the low noise amplifier. The proposed cascode inverter LNA is one stage amplifier with a voltage reference and without choke inductors. The designed 2.4GHz LNA achieves a power gain of 25dB, a noise figure of 2.2dB, and power consumption of 255㎽ at 2.5V power supply.

  • PDF

Optimal Long-term Transmission Planning Algorithm using Non-linear Branch-and-bound Method (비선형 분산안전법을 이용한 최적장기송전계률 알고리)

  • 박영문;신중린
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.5
    • /
    • pp.272-281
    • /
    • 1988
  • The problem of optimal transmission system planning is to find the most economical locations and time of transmission line construction under the various constraints such as available rights-of-way, finances, the technical characteristics of power system, and the reliability criterion of power supply, and so on. In this paper the constraint of right-of-way is represented as a finite set of available rights-of-way. And the constructed for a unit period. The electrical constraints are represented in terms of line overload and steady state stability margin. And the reliability criterion is dealt with the suppression of failure cost and with single-contingency analysis. In general, the transmission planning problem requires integer solutions and its objective function is nonlinear. In this paper the objective function is defined as a sum of the present values of construction cost and the minimum operating cost of power system. The latter is represented as a sum of generation cost and failure cost considering the change of yearly load, economic dispatch, and the line contingency. For the calculation of operating cost linear programming is adopted on the base of DC load flow calculation, and for the optimization of main objective function nonlinear Branch-and-Bound algorithm is used. Finally, for improving the efficiency of B & B algorithm a new sensitivity analysis algorithm is proposed.

AN APPROPRIATE INFLOW MODEL FOR SIMULTANEOUS DISSOLUTION AND DEGRADATION

  • Lee, Ju-Hyun;Kang, Sung-Kwon;Choi, Hoo-Kyun
    • Honam Mathematical Journal
    • /
    • v.31 no.1
    • /
    • pp.109-124
    • /
    • 2009
  • Based on the observed data for Clarithromycin released, three commonly used inflow models: the power, the exponential, and the logarithmic models are considered. Among them, the power model is used most in practice for simplicity. Using the numerical parameter estimation techniques, the parameters appeared in the model equations are estimated. Through the numerical estimation results using the several experimental data sets, the exponential model turns out to be best among the three models. More specifically, the sum of squares of absolute errors and the sum of squares of relative errors for the exponential model are reduced by 80-95 % for the experimental data sets and 60-90 % for the noise added data sets compared with those for the power and logarithmic models. A typical experimental data set is used in this paper to show the estimation method and its numerical results. The proposed numerical method and its algorithm are designed for estimating the parameters appeared in the model differential equations for which the exact form of the solution is unknown in general. The methodology developed can be applied to more general cases such as the nonlinear ordinary differential equations or the partial differential equations.

Efficient Power Allocation Algorithm for Wireless Networks (무선망의 효율적 전력 할당 알고리즘)

  • Ahn, Hong-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.103-108
    • /
    • 2016
  • In communication systems the solution of the problem of maximizing the mutual information between the input and output of a channel composed of several subchannels under total power constraint has a waterfilling structure. OFDM and MIMO can be decomposed into parallel subchannels with CSI. Waterfilling solves the problem of optimal power allocation to these subchannels to achieve the rate approaching the channel capacity under total power constraint. In waterfilling, more power is alloted to good channels(high SNR) and less or no power to bad channels to increase the rate of good channels, resulting in channel capacity. Waterfilling finds the exact water level satisfying the power constraint employing an iterative algorithm to estimate and update the water level. In this process computation of partial sums of inverse of square of subchannel gain is repeatedly required. In this paper we reduced the computation time of waterfilling algorithm by replacing the partial sum computation with reference to an array which contains the precomputed partial sums in initialization phase.

Design and Amplitude Modulation Characteristics with Bias of Class J Power Amplifier for CSB (CSB용 J급 전력증폭기 설계 및 바이어스에 따른 진폭 변조 특성)

  • Su-kyung Kim;Kyung-Heon Koo
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.849-854
    • /
    • 2023
  • In this paper, a high-efficiency power amplifier was designed by applying the operating point Class J using LDMOS(laterally diffused metal oxide semiconductor) and optimizing the output matching circuit so that the second harmonic impedance becomes the reactance impedance. The designed power amplifier has a frequency of 108 ~ 110 MHz, Characteristics of PAE(power added efficiency) is 71.5% at PSAT output (54.5 dBm), 55.5% at P1dB output (51.5 dBm), and 24.38% at 45 dBm. The CSB(carrier with sideband) amplifier, which is the reference signal in the spatial modulation method, has an operating output of 45 dBm ~ 35 dBm, and linear SDM(sum in the depth of modulation) characteristics(40% ± 0.3%) were obtained. We measure the characteristics in amplitude modulation according to the bias operating point of the power amplifier for CSB and propose the optimal operating point to obtain linear modulation characteristics.

Multi-user Diversity Scheduling Methods Using Superposition Coding Multiplexing (중첩 코딩 다중화를 이용한 다중 사용자 다이버시티 스케줄링 방법)

  • Lee, Min;Oh, Seong-Keun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4A
    • /
    • pp.332-340
    • /
    • 2010
  • In this paper, we deal with multi-user diversity scheduling methods that transmit simultaneously signals from multiple users using superposition coding multiplexing. These methods can make various scheduling methods be obtained, according to strategies for user selection priority from the first user to the first-following users, strategies for per-user power allocation, and resulting combining strategies. For the first user selection, we consider three strategies such as 1) higher priority for a user with a better channel state, 2) following the proportional fair scheduling (PFS) priority, 3) higher priority for a user with a lower average serving rate. For selection of the first-following users, we consider the identical strategies for the first user selection. However, in the second strategy, we can decide user priorities according to the original PFS ordering, or only once an additional user for power allocation according to the PFS criterion by considering a residual power and inter-user interference. In the strategies for power allocation, we consider two strategies as follows. In the first strategy, it allocates a power to provide a permissible per-user maximum rate. In the second strategy, it allocates a power to provide a required per-user minimum rate, and then it reallocates the residual power to respective users with a rate greater than the required minimum and less than the permissible maximum. We consider three directions for scheduling such as maximizing the sum rate, maximizing the fairness, and maximizing the sum rate while maintaining the PFS fairness. We select the max CIR, max-min fair, and PF scheduling methods as their corresponding reference methods [1 and references therein], and then we choose candidate scheduling methods which performances are similar to or better than those of the corresponding reference methods in terms of the sum rate or the fairness while being better than their corresponding performances in terms of the alternative metric (fairness or sum rate). Through computer simulations, we evaluate the sum rate and Jain’s fairness index (JFI) performances of various scheduling methods according to the number of users.