냉각수 계통의 운전변수가 중앙냉방시스템의 에너지소비량에 미치는 영향 (The Effects of Operational Conditions of Cooling Water System on Energy Consumption for Central Cooling System)

  • 안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.8-13
    • /
    • 2017
  • The effects of operational conditions of cooling water system on energy consumption for central cooling system are researched by using TRNSYS program. Cooling tower water pump flow rate, cooling tower fan flow rate, and condenser water temperature with various dry-bulb and wet-bulb temperatures are varied and their effects on total and component power consumption are studied. If the fan maximum flow rates of cooling tower is decreased, cooling tower fan and total power consumptions are increased. If the cooling tower water pump maximum flow rates is decreased, chiller and total power consumptions are increased. If condenser water set-point temperature is increased, chiller power consumption is increased and cooling tower fan power consumption is decreased, respectively.

하나로 2차 냉각탑의 냉각능력 평가 (Evaluation for the Cooling Capability of Secondary Cooling Tower in HANARO)

  • 박용철;우종섭;조영갑;류정수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.345-350
    • /
    • 2000
  • The heat produced by the fission in the fuel of HANARO, 30 MW research reactor, is transferred from the primary cooling water to the secondary cooling water through heat exchangers, and the heat absorbed by the secondary cooling water is released into the atmosphere by the 33 MW cooling tower which is a mechanical induced draft and counter flow type. If the outlet temperature of cooling tower exceeds 33 of due to the loss of the cooling tower performance under reactor operation above $50\%$ of the full power, the reactor power should be reduced to half of the full power for safe operation. Therefore, the cooling capability of cooling tower should be maintained for the reactor to be normally operated. To predict the capability of cooling tower for full power reactor operation of 30 MW, the performance test of cooling tower was done at the reactor present power of 24 MW and the capability was respectively evaluated by characteristics and performance curves methods in accordance with the Code of Cooling Tower Institute of U.S.A. to confirm the reliability of evaluation. As a result, it was confirmed, through the results of each evaluation, that the cooling capability of cooling tower meets the design required heat load. Also, the equations of the performance and the characteristics curves of the cooling tower, based on the collected data during this performance test, was obtained for developing the calculation program to predict the cooling capability during reactor operation.

  • PDF

풍력터빈 타워 하중 저감을 위한 타워 댐퍼 게인 스케줄링 알고리즘 설계 (Design of Tower Damper Gain Scheduling Algorithm for Wind Turbine Tower Load Reduction)

  • 김철진;김관수;백인수
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.1-13
    • /
    • 2018
  • This paper deals with the NREL (National Renewable Energy Laboratory) 5-MW reference wind turbine. The controller which include MPPT (Maximum power point tracking) control algorithm and tower load reduction control algorithm was designed by MATLAB Simulink. This paper propose a tower damper algorithm to improve the existing tower damper algorithm. To improve the existing tower damper algorithm, proposed tower damper algorithm were applied the thrust sensitivity scheduling and PI control method. The thrust sensitivity scheduling was calculated by thrust force formula which include thrust coefficient table. Power and Tower root moment DEL (Damage Equivalent Load) was set as a performance index to verify the load reduction algorithm. The simulation were performed 600 seconds under the wind conditions of the NTM (Normal Turbulence Model), TI (Turbulence Intensity)16% and 12~25m/s average wind speed. The effect of the proposed tower damper algorithm is confirmed through PSD (Power Spectral Density). The proposed tower damper algorithm reduces the fore-aft moment DEL of the tower up to 6% than the existing tower damper algorithm.

UsN 기반의 송전철탑 건전성 감시진단시스템 기본설계 (UsN based Soundness Monitoring Diagnosis System of Power Transmission Steel Tower)

  • 이동철;배을록;김우정;민병운
    • 전기학회논문지P
    • /
    • 제56권1호
    • /
    • pp.56-62
    • /
    • 2007
  • In this paper, design method for power tower hazard diagnosis/predition system based on UsN was proposed. The proposed method used multi-hybrid sensors to measure rotation, displacement, and inclination state of power tower, and made decision/prediction of hazard of power tower. System design was made with requirement analysis of monitoring for transmission power facility and use of MEMS and optic fiber sensors. For hazard decision, analysis of correlation was made using sensor output. LN based on IEC61850,international standard for digital substation, was also proposed. For transmission facility monitoring, digital substation and power tower were considered as parts of power facility networks.

Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members

  • Woo, Sangkyun;Chu, Inyeop;Youn, Byongdon;Kim, Kijung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.293-298
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.

향류형 냉각탑의 기본설계 프로그램 개발 (Program Development for Design of Counter-flow Cooling Tower)

  • 고광호;인종수;오태일
    • 한국산업융합학회 논문집
    • /
    • 제7권4호
    • /
    • pp.383-389
    • /
    • 2004
  • This paper is to develop the program for sizing of a counter-flow cooling tower. Air flow, air exit tmperature, fan power are calculated from design coditions of cooling tower by using this program. The basic equations and solutions of the heat transfer and pressure drop of cooling tower are descrived and the algorithm development for design of cooling tower is performed. The variation of fan power of cooling tower in acoording to variation of cell area and fill height is performed by using this program. This result shows that the optimal design for install and running cost of cooling tower can be performed by using this program.

  • PDF

Design feasibility of double-skinned composite tubular wind turbine tower

  • Han, Taek Hee;Park, Young Hyun;Won, Deokhee;Lee, Joo-Ha
    • Wind and Structures
    • /
    • 제21권6호
    • /
    • pp.727-753
    • /
    • 2015
  • A double-skinned composite tubular (DSCT) wind power tower was suggested and automatic section design software was developed. The developed software adopted the nonlinear material model and the nonlinear column model. If the outer diameter, material properties and design capacities of a DSCT wind power tower are given, the developed software performs axial force-bending moment interaction analyses for hundreds of sections of the tower and suggests ten optimized cross-sectional designs. In this study, 80 sections of DSCT wind power towers were designed for 3.6 MW and 5.0 MW turbines. Moreover, the performances of the 80 designed sections were analyzed with and without considerations of large displacement effect. In designing and analyzing them, the material nonlinearity and the confining effect of concrete were considered. The comparison of the analysis results showed the moment capacity loss of the wind power tower by the mass of the turbine is significant and the large displacement effect should be considered for the safe design of the wind power tower.

복합재를 이용한 대형 풍력 발전용 타워 기술개발 동향분석 (A Study on Trends for Development of Wind Turbine Tower)

  • 홍철현;정재훈;강병윤;문병영
    • 한국유체기계학회 논문집
    • /
    • 제15권4호
    • /
    • pp.50-54
    • /
    • 2012
  • Wind-power generation, which is recently drawing attention as one of renewable energies across the world, has been developed mainly by Europe. As the demand for the wind-power generation rose and the amount of wind-power generation increased, the studies on megawatt-class wind-power system have been active, and the use of composite with such properties as less weight, more strength, anti-corrosion and environment-friendliness has required gradually. In other word, wind turbine tower will be required to be lighter, more reliable and more consistent. Therefore it is necessary to lose weight of the wind turbine tower. This points squarely toward hybrid/composite tower production growing. It is important to note however that hybrid/composite tower production as it is today is flawed and that there are ways to improve greatly on the performance of these towers in manufacturing process and in their in-service performance. Through this, we have some detail on the current process and its advantage of cost and weight of towers.

냉각탑 성능 예측을 위한 프로그램 개발 (Program Development for the Prediction of Cooling Tower Performance)

  • 정재형;정재현;최영기
    • 설비공학논문집
    • /
    • 제26권3호
    • /
    • pp.130-136
    • /
    • 2014
  • The present study is performed to set up the framework of cooling tower performance predictions. The performance of mechanical forced draft cooling tower is directly related to the state of a nuclear power plant system, such as the condenser and evaporator. The main parameters related to the state of systems are as follows : wet bulb temperature, dry bulb temperature and absolute humidity. The performance evaluation of cooling tower must be considered at the power plant design. In this study, the toolkit developed by the American Cooling Tower Industry association (CTI) has been used for the framework construction. In order to validate the framework, it is being applied to the cooling tower constructed for the U.S. Nuclear Power Plant. The test results have shown good agreements with the cold water temperature on the cooling tower performance curves provided by manufacturers.

풍하중을 받는 송전철탑의 정적, 동적 및 좌굴해석 (Static, Dynamic and Buckling Analyses of a Power Transmission Tower under Wind Load)

  • 정형조;신동승;문병욱;박지훈;이성경;민경원
    • 한국전산구조공학회논문집
    • /
    • 제19권4호
    • /
    • pp.369-374
    • /
    • 2006
  • 가섭선 및 애자가 연결되어 있는 복잡한 구조물인 송전철탑의 3차원 모델링을 통하여 동특성을 파악하고, 풍하중에 대한 응답 특성을 정적, 동적 및 좌굴 해석을 가섭선의 절단 유무에 따라 분석하였다. 우선, 고유치해석을 통해, 송전철탑이라는 구조시스템이 일반 건축물과는 달리 극소수의 저차 모드가 구조물의 동적 거동을 좌우하지 않고, 상대적으로 많은 모드들이 동적 거동에 기여한다는 것을 확인하였다. 두 번째로, 정적 해석과 좌굴 해석을 통해, 대상 구조물이 정적인 개념의 풍하중에 대해서 구조적으로 안전하고 좌굴에 대해서도 충분한 안전율을 확보하고 있음을 확인하였다 그러나, 모든 가섭선이 단절되는 극단적인 경우에는 안전율이 상당히 낮아졌으며 이러한 경우에 구조물의 붕괴 및 전도를 방지할 대책에 대한 검토가 필요하다고 사료된다 마지막으로, 풍하중의 시간에 따른 변화를 고려한 동적해석을 통해, 풍하중의 동적 변동성분이 구조물의 응답을 증가시키고 있음을 확인하였다.