• Title/Summary/Keyword: power system equivalent

Search Result 732, Processing Time 0.031 seconds

Fault Analysis Method for Power Distribution Grid with PCS-based Distributed Energy Resources

  • Kim, Dong-Eok;Cho, Namhun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.522-532
    • /
    • 2017
  • In this study, we propose a fault analysis method for a power distribution grid with PCS-based DERs. We first explain the characteristics of a PCS-based DER. According to the characteristics, the DER is considered as a current-controlled voltage source, which produces varying voltages within a certain limit so that currents equal to given references flowing from the DER to the grid (currents controlled). So, we introduce the symmetrical equivalent models in the form of varying voltage source for fault analysis and then, construct a convex optimization problem to solve the fault problem associated with the equivalent models and grid conditions. Thus, the proposed method enables to perform a proper fault analysis considering the characteristics of the DER, which are currents controlled, voltage limited, and unity power factor achievement. To verify the validity of the proposed method, we perform computer simulations with the proposed method and with MATLAB Simulink, and the results are compared.

Energy harvesting from conducted electromagnetic interference of fluorescent light for Internet of Things application

  • Hyoung, Chang-Hee;Hwang, Jung-Hwan
    • ETRI Journal
    • /
    • v.44 no.5
    • /
    • pp.759-768
    • /
    • 2022
  • A novel energy harvesting technique that uses conducted electromagnetic interference as an energy source is presented. Conducted EMI generated from fluorescent light using a switched-mode power supply was measured and modeled as an equivalent voltage source. Two types of rectifier circuits-a bridge rectifier and a voltage doubler-were used as the harvesting devices for conducted EMI source. The matching networks were designed based on the equivalent model, and the harvested power was improved. The implemented energy harvester produces a regulated power over 68.9 mW and current over 15.1 mA while a regulated voltage can be selected between 3.3 V and 5 V. The proposed system shows the highest harvesting power indoor environment and can provide enough power for the Internet of Things devices.

Modeling and a Simple Multiple Model Adaptive Control of PMSM Drive System

  • Kang, Taesu;Kim, Min-Seok;Lee, Sa Young;Kim, Young Chol
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.442-452
    • /
    • 2017
  • This paper deals with the input-output modeling of a vector controlled PMSM drive system and design of a simple multiple model adaptive control (MMAC) scheme with desired transient responses. We present a discrete-time modeling technique using closed-loop identification that can experimentally identify the equivalent models in the d-q coordinates. A bank of linear models for the equivalent plant of the current loop is first obtained by identifying them at several operating points of the current to account for nonlinearity. Based on these models, we suggest a simple q-axis MMAC combined with a fixed d-axis controller. After the current controller is designed, another equivalent model including the current controller in the speed control loop shall be similarly obtained, and then a fixed speed controller is synthesized. The proposed approach is demonstrated by experiments. The experimental set up consists of a surface mounted PMSM (5 KW, 220V, 8 poles) equipped with a flywheel load of 220kg and a digital controller using DSP (TMS320F28335).

Analysis of HVDC Inverter and Application of Objective Functions for the Optimal Filter Design (직류송전 인버터의 필터 최적설계를 위한 해석 및 목적함수의 선정)

  • 오성철;정교범
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.82-89
    • /
    • 2001
  • This paper proposes several methods to analyze dynamic and static characteristics of HVDC inverter system. The characteristic analysis is essential of the controller and filter design of the HVDC inverter system. Dynamic characteristic can be analyzed with EMTP simulation and static characteristic can be obtained by solving newly proposed load flow equation which includes the filter and load characteristic. New simple per-phase-equivalent circuit is also proposed. In this circuit, HVDC inverter is considered as a current source depending on the on-off status of switch. Dynamic and static characteristic can be analyzed by the proposed per-phase-equivalent circuit. For the optimal filter design, various performance criteria are proposed. The performance index, based on the per-phase-equivalent circuit, is calculated. Voltage harmonics and filter power loss are selected as criteria. Optimization procedure is explained to find optimal passive filter parameters.

  • PDF

A Contingency Screening Algorithm Using SIME for Transient Stability Assessment of the KEPCO System

  • Lee, J.;Lee, B.;Kwon, S.H.;Nam, H.K.;Ahn, T.;Choo, J.B.;Yi, K.
    • Journal of KIEE
    • /
    • v.11 no.1
    • /
    • pp.55-61
    • /
    • 2001
  • SIME(Single Machine Equivalent) method has been recognized as a useful tool to determine transient stability of power system. In this paper, SIME method is used to develop the KEPCO transient stability assessment (TSA) tool. A new screening algorithm that can be generators are identified by a new index in the early stage of the time domain simulation. Thus, computational time require to find OMIB(One Machine Infinite Bus) can be reduced significantly. Second, clustering critical machines can be performed even in very stable cases. It enables to be avoid extra calculation of time trajectory that is needed in SIME for classifying the stable cases. This algorithm is applied to the fast TSA of the KEPCO system in the year of 2010.

  • PDF

Analysis of Economic Life Cycle for Hydro-Generator Based on Annual Equivalent Cost Method (연간등가비용법을 이용한 수력발전기의 경제적 수명주기 분석)

  • Lee, Sung-Hun;Chang, Jeong-Ho;Kim, Jin-O;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.1993-1999
    • /
    • 2011
  • Today, the power utilities is setting on the slow load growth and the aging of power equipment, and then could spend the efforts on the stability of system performance. Asset management may be defined as the process of maximizing corporate profit by maximizing performance and minimizing cost over the entire life cycle of power equipment. Therefore, asset management is great way to fulfill the economic investment and the stability of system performance. This paper presents the application of effective asset managem ent from an economic perspective. A proposed method is considering the life cycle analysis using life cycle cost methodology for hydro-generator during the total life cycle. The life cycle cost methodology include a way to calculating maintenance and operating costs. The proposed method will be expected to play an important role in investment decision making considering economic evaluation.

A Simple ESR Measurement Method for DC Bus Capacitor Using DC/DC Converter (DC/DC 컨버터를 이용한 DC Bus 커패시터의 간단한 ESR 측정 기법)

  • Shon, Jin-Geun;Kim, Jin-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.372-376
    • /
    • 2010
  • Electrolytic capacitors have been widely used in power electronics system because of the features of large capacitance, small size, high-voltage, and low-cost. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. The estimation of the equivalent series resistance(ESR) is important parameter in life condition monitoring of electrolytic capacitor. This paper proposes a simple technique to measure the ESR of an electrolytic capacitor. This method uses a switching DC/DC boost converter to measure the DC Bus capacitor ESR of power converter. Main advantage of the proposed method is very simple in technique, consumes very little time and requires only simple instruments. Simulation results are shown to verify the performance of the proposed method.

A Study for Dynamic Equivalent Models in Large Power System (대규모 전력계통의 동적등가 축약모형 연구)

  • Chang, Byung-Hoon;Choo, Jin-Boo;Kwon, Sea-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1305-1307
    • /
    • 1999
  • dynamic analysis of power systems is required the information for building a transfer function of has the heavy calculation of high order matrices. Since generally the order of the state matrix is over the limit of commercial analysis programs such as MASS(Multi-Area Small Signal Stability) Program, it is necessary to develop dynamic equivalent systems with preserving essential properties of the original system. In this work, a procedurd to find an optimal location of FACTS controllers is presented. The procedure was applied to KEPCO system in the year of 2000. The results on a test system demonstrate the accuracy of dynamic equivalencing and verify the effect of FACTS controllers.

  • PDF

A Performance Analysis and Experiment of Viscous Torsional Vibration Damper for High Speed Engine Shaft System (고속엔진축계용 점성 비틀림진동감쇠기의 성능해석 및 실험)

  • Yang, B.S.;Jeong, T.Y.;Kim, K.D.;Kim, D.J.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.98-105
    • /
    • 1997
  • In general, crankshafts which are used in internal combustion reciprocating engines are subjects to high torsional vibration. Therefore, a damper is often used to minimize the torsional vibration in reciprocating engines. In this paper, in order to investigate damping performance of viscous damper, the real effective viscosity and complex damping coefficient of silicone oil, and the effective inertia moment of inertia ring are calculated considering the relative motion between damper casing and inertia ring. Based on these results multi-cylinder shaft is modeled into equivalent 2-degree of freedom system and optimum condition is estimated by calculating the amplification factor of viscous damper. Also the test damper was manufactured according to the result of theoretical investigation, the performance and durability was ascertained through experimental examination.

  • PDF

Partitioning Technique for Equivalents of Power System (전력계통 등가화를 위한 지역분할기법)

  • Han, Soung-Ho;Rim, Seong-Jeong;Yoon, Yong-Han;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.112-114
    • /
    • 1993
  • This paper presents a partitioning technique for equivalent models to large scale power system. The proposed partitioning technique is utilized by using a heuristic approach based on distributed array processor and the coherent groupings of generator buses. In this paper the reduced Ward-PV method considering the characteristics of buses is used to equivalent models of external system. The technique is demonstrated on New England system with 39 buses, 46 lines and 10 generators.

  • PDF