• 제목/요약/키워드: power shutdown

검색결과 306건 처리시간 0.025초

A Three-Dimensional Operational Transient Simulation of the CANDU Core with Typical Reactor Regulating System

  • Yeom, Choong-Sub;Kim, Hyun-Dae;Park, Kyung-Seok;Park, Jong-Woon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.500-505
    • /
    • 1995
  • This paper describes the results of simulation of a CANDU operational transient problem (re-startup after short shutdown) using the Coupled Reactor Kinetics(CRKIN) code developed previously with CANDU Reactor Regulating System(RRS) logic. The performance in the simulation is focused on investigating the behaviours of neutron power and regulating devices in accordance with the changes of xenon concentration following the operation of the RRS.

  • PDF

Analysis of Dynamic Behavior of Natural Circulation Heat Recovery Steam Generators

  • Kim, Sung-Ho;Lee, Chi-Hwan;Cho, Chang-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.134.3-134
    • /
    • 2001
  • The dynamic behavior of heat recovery steam generators for combined cycle power plant is simulated in cases of startup and shutdown conditions. To ensure performance and design data, dynamic model of the HRSG was developed and dynamic simulation was performed. The dynamic analysis will undoubtedly reduce costs which is associated with plant startup and contribute to a smooth commercial plant operation.

  • PDF

원자로 보호 계통 설계 개선 (Design Improvement on Reactor Shutdown System in Nuclear Power Plant)

  • 박철주;김석남;오연우
    • 산업경영시스템학회지
    • /
    • 제19권38호
    • /
    • pp.69-76
    • /
    • 1996
  • The Special safety systems are incorporated into the plant design to limit radioactive releases to the public in the event of accident. Wolsung 2 is better builted than Wolsung 1 by 84 design changes for new approval requirements, codes & standards changes and manufacturing changes etc. This paper analysed and discussed the design change items for nuclear reactor safety system and needs development of design engineering for digital protection system.

  • PDF

노후 석탄화력발전소 가동중단에 따른 발전소 주변지역의 초미세먼지 농도 감소효과 분석 (The Local Effects of Coal-fired Power Plant Shutdown on PM2.5 Concentration: Evidence from a Policy Experiment in Korea)

  • 이동규;성재훈
    • 자원ㆍ환경경제연구
    • /
    • 제27권2호
    • /
    • pp.315-337
    • /
    • 2018
  • 정부는 준공된 지 30년 이상 경과한 8기의 노후 석탄화력발전소를 2017년 6월 한 달간 가동중단하였다. 이번 정부의 조치는 일종의 정책실험으로 자연실험에 가까운 특성을 가지고 있다. 본고는 이러한 정책실험의 특성을 이용하여 가동중단 조치에 따른 초미세먼지 농도변화의 인과적 효과를 분석하였다. 이를 위해 본 연구에서는 정책대상 발전기 중 2기가 위치한 영동 화력발전소 인근 지점을 실험군으로, 그곳에서 약 40km 거리를 가진 삼척 지점을 대조군으로 하여 이중차분법을 실행하였다. 해당 대조군은 발전소 지역과 지리적, 지형적 특성은 유사하나 해당 발전소에서 배출된 초미세먼지로부터의 직접적인 영향은 크지 않다는 특징을 가지고 있다. 분석 결과, 이번 가동중단 조치로 영동석탄화력발전소 주변지역은 $3.7{\sim}4.4{\mu}g/m^3$의 초미세먼지 농도 감소효과가 발생한 것으로 분석되었다.

자율학습기반의 에너지 효율적인 클러스터 관리에서의 성능 개선 (Performance Improvement of an Energy Efficient Cluster Management Based on Autonomous Learning)

  • 조성철;정규식
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제4권11호
    • /
    • pp.369-382
    • /
    • 2015
  • 에너지 절감형 서버 클러스터에서는 에너지 절감을 고려하지 않는 기존 서버 클러스터에 비해 서비스 품질을 보장하면서 전력소비를 절감하는 것을 목표로 하며, 현재의 부하를 처리하는 데 필요한 최소수의 서버들만 ON 하도록 고정 주기 또는 가변 주기로 서버들의 전원모드를 조정한다. 이에 대한 기존 연구들은 전력을 절감하거나 열을 낮추는데 노력해왔지만 에너지 효율성을 잘 고려하지 못했다. 본 논문에서는 기존 자율학습기반의 서버 전원 모드 제어 방법의 단위전력당 성능과 QoS를 높이기 위한 에너지 효율적인 클러스터 관리기법을 제안한다. 제안 방법은 다중임계기반의 자율학습 방법과 전력소모 예측 방법을 결합한 서버 전원 모드 제어이다. 일반적인 부하 상황에서는 다중임계 학습기반의 서버 전원 모드 제어를 적용하고, 급변하는 부하 상황에서는 예측기반의 서버 전원 모드 제어가 적용된다. 일반적 상황과 급변하는 상황의 구별은 현재의 사용자 요청과 관찰된 과거 몇 분의 사용자 요청의 비율에 따라 이루어진다. 또한, 동적종료 기법을 추가로 적용해 서버가 OFF 하는 데 소요되는 시간을 단축한다. 제안 방법은 16대 서버로 구성된 클러스터 환경에서 3가지 부하 패턴을 이용하여 실험을 수행한다. 다중임계 학습, 예측, 동적종료를 함께 이용한 실험에서 단위전력당 성능(유효응답 수)과 표준화된 QoS 측면에서 가장 우수한 결과를 보여준다. 제안하는 방법과 파라미터 로드된 단일임계 학습을 비교할 때 뱅킹 부하패턴, 실제 부하패턴, 가상 부하패턴에서 단위전력당 유효응답 수가 각각 1.66%, 2.9%, 3.84% 향상되고, QoS 관점에서는 각각 0.45%, 1.33%, 8.82% 향상되었다.

원전 급수펌프 구동용 터빈 제어시스템 개발 (A Development of Digital Control System for FWPT In Nuclear Power Plant)

  • 최인규;정창기;김병철;김종안;우주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1885-1886
    • /
    • 2006
  • The thermal energy from nuclear fission is transferred to the steam generator which is a kind of a large heat exchanger. After the feedwater is injected into the steam generator and absorbs the thermal energy, it is converted into the steam. This steam goes into the turbine. The balance between the generated energy and the consumed energy is required for the nuclear power plant to be stable. For the purpose of which, the feed water, a parameter for energy transfer, should be controlled in stability. Usually, the nuclear power plants are operated in base load in the view of power system for the stability of fission system. Therefore, though there will be almost no unbalance, there can be some instability from unbalance in case of startup/shutdown or disturbance. In this case, the controllability of feedwater pump is very important for the quick recover of stability.

  • PDF

빠른 응답성을 갖는 가변속 DFIM 분석 (Analysis of Doubly Fed Variable-Speed Pumped Storage Hydropower Plant for Fast Response)

  • 손금뢰;서정진;차한주
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.425-430
    • /
    • 2022
  • A pumped storage power station is an important means to solve the problem of peak load regulation and ensures the safety of power grid operation. The doubly fed variable-speed pumped storage (DFVSPS) system adopts a doubly fed induction machine (DFIM) to replace the synchronous machine used in traditional pumped storage. The stator of DFIM is connected to the power grid, and the three-phase excitation windings are symmetrically distributed on the rotor. Excitation current is supplied by the converter. The active and reactive power of the unit can be quickly adjusted by adjusting the amplitude, frequency, and phase of the rotor-side voltage or current through the converter. Compared with a conventional pumped storage hydropower station (C-PSH), DFVSPS power stations have various operating modes and frequent start-up and shutdown. This study introduces the structure and principle of the DFVSPS unit. Mathematical models of the unit, including a model of DFIM, a model of the pump-turbine, and a model of the converter and its control, are established. Fast power control strategies are proposed for the unit model. A 300 MW model of the DFVSPS unit is established in MATLAB/Simulink, and the response characteristics in generating mode are examined.

약한 AC 계통에서 동기조상기용 여자 시스템 특성에 따른 HVDC 과도 특성 (Dynamic Performance of HVDC According to Excitation System Characteristics of Synchronous Compensator in a Weak AC System)

  • 김찬기;김정부;심응보
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권6호
    • /
    • pp.431-440
    • /
    • 2000
  • This paper analyses the dynamic performance of HVDC System connected to a weak AC system for various exciter characteristics of synchronous machines connected at the converter bus. Conventionally capacitors are used to supply reactive power requirement at a strong converter bus. But the installation of synchronous machine is essential in a isolated weak network to re-start after a shutdown of HVDC and to increase system strength. The dynamic performance of a synchronous machine depends on the characteristics depends of its exciter. In this paper, several exciter types are used to investigate their effect on the dynamic performance of the HVDC system and modifications to standard exciter topologies are suggested to mitigate observed problems.

  • PDF

Performance evaluation of safety-critical systems of nuclear power plant systems

  • Kumar, Pramod;Singh, Lalit Kumar;Kumar, Chiranjeev
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.560-567
    • /
    • 2020
  • The complexity of safety critical systems of Nuclear Power Plant continues to increase rapidly due its transition from analog to digital systems. It has thus become progressively more imperative to model these systems prior to their implementation in order to meet the high performance, safety and reliability requirements. Timed Petri Nets (TPNs) have been widely used to model such systems for non-functional analysis. The paper presents a novel methodology for the analysis of the performance metrics using PN modeling. The paper uses the isomorphism property of the TPNs and the Markov chains for the performance analysis of the safety critical systems. The presented methodology has been validated on a Shutdown System of a Nuclear Power Plant.

마이크로 가스터빈 열병합 발전시스템 성능평가 (Performance Test of MGT Combined Heat & Power System)

  • 허광범;박정극;임상규
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF