• Title/Summary/Keyword: power shutdown

Search Result 306, Processing Time 0.032 seconds

Study on the Prediction Model of Reheat Gas Turbine Inlet Temperature using Deep Neural Network Technique (심층신경망 기법을 이용한 재열 가스터빈 입구온도 예측모델에 관한 연구)

  • Young-Bok Han;Sung-Ho Kim;Byon-Gon Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.841-852
    • /
    • 2023
  • Gas turbines, which are used as generators for frequency regulation of the domestic power system, are increasing in use due to the carbon-neutral policy, quick startup and shutdown, and high thermal efficiency. Since the gas turbine rotates the turbine using high-temperature flame, the turbine inlet temperature is acting as a key factor determining the performance and lifespan of the device. However, since the inlet temperature cannot be directly measured, the temperature calculated by the manufacturer is used or the temperature predicted based on field experience is applied, which makes it difficult to operate and maintain the gas turbine in a stable manner. In this study, we present a model that can predict the inlet temperature of a reheat gas turbine based on Deep Neural Network (DNN), which is widely used in artificial neural networks, and verify the performance of the proposed DNN based on actual data.

Preliminary Radiation Exposure Dose Evaluation for Workers of the Landfill Disposal Facility Considering the Radiological Characteristics of Very Low Level Concrete and Metal Decommissioning Wastes (극저준위 콘크리트, 금속 해체방폐물의 방사선적 특성을 고려한 매립형 처분시설 방사선작업자 예비 피폭선량 평가)

  • Ho-Seog Dho;Ye-Seul Cho;Hyun-Goo Kang;Jae-Chul Ha
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.509-518
    • /
    • 2023
  • The Kori Unit 1 nuclear power plant, which is planned to be dismantled after permanent shutdown, is expected to generate a large amount of various types of radioactive waste during the dismantling process. For the disposal of Very-low-level waste, which is expected to account for the largest amount of generation, the Korea Radioactive waste Agency (KORAD) is in the process of detailed design to build a 3-phase landfill disposal facility in Gyeongju. In addition, a large container is being developed to efficiently dispose of metal and concrete waste, which are mainly generated as Very low-level waste of decommissioning. In this study, based on the design characteristics of the 3-phase landfill disposal facility and the large container under development, radiation exposure dose evaluation was performed considering the normal and accident scenarios of radiation workers during operation. The direct exposure dose evaluation of workers during normal operation was performed using the MCNP computer program, and the internal and external exposure dose evaluation due to damage to the decommissioning waste package during a drop accident was performed based on the evaluation method of ICRP. For the assumed scenario, the exposure dose of worker was calculated to determine whether the exposure dose standards in the domestic nuclear safety act were satisfied. As a result of the evaluation, it was confirmed that the result was quite low, and the result that satisfied the standard limit was confirmed, and the radiational disposal suitability for the 3-phase landfill disposal facility of the large container for dismantled radioactive waste, which is currently under development, was confirmed.

Dynamic Behavior of Reactor Internals under Safe Shutdown Earthquake (안전정기지진하의 원자로내부구조물 거동분석)

  • 김일곤
    • Computational Structural Engineering
    • /
    • v.7 no.3
    • /
    • pp.95-103
    • /
    • 1994
  • The safety related components in the nuclear power plant should be designed to withstand the seismic load. Among these components the integrity of reactor internals under earthquake load is important in stand points of safety and economics, because these are classified to Seismic Class I components. So far the modelling methods of reactor internals have been investigated by many authors. In this paper, the dynamic behaviour of reactor internals of Yong Gwang 1&2 nuclear power plants under SSE(Safe Shutdown Earthquake) load is analyzed by using of the simpled Global Beam Model. For this, as a first step, the characteristic analysis of reactor internal components are performed by using of the finite element code ANSYS. And the Global Beam Model for reactor internals which includes beam elements, nonlinear impact springs which have gaps in upper and lower positions, and hydrodynamical couplings which simulate the fluid-filled cylinders of reactor vessel and core barrel structures is established. And for the exciting external force the response spectrum which is applied to reactor support is converted to the time history input. With this excitation and the model the dynamic behaviour of reactor internals is obtained. As the results, the structural integrity of reactor internal components under seismic excitation is verified and the input for the detailed duel assembly series model could be obtained. And the simplicity and effectiveness of Global Beam Model and the economics of the explicit Runge-Kutta-Gills algorithm in impact problem of high frequency interface components are confirmed.

  • PDF

Effects of the Excitation Level on the Dynamic Characteristics of Electrical Cabinets of Nuclear Power Plants (진동수준이 원자력발전소 전기 캐비닛의 동특성에 미치는 영향)

  • Cho, Sung-Gook;Kim, Doo-Kie;Go, Sung-Hyuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.23-30
    • /
    • 2010
  • Seismic qualification (SQ) is required prior to the installation of safety related electrical cabinets in nuclear power plants (NPPs). Modal identification of the electrical equipment is one of the most significant steps to perform SQ, and is an essential process to construct a realistic analytical model. In this study, shaking table tests were conducted to identify a variation of the dynamic characteristics of a seismic monitoring system cabinet installed in NPPs according to the excitation level. Modal identification of the cabinet has been performed by a frequency domain decomposition method. The results of this study show that the dynamic properties of the cabinet are nonlinearly varied according to the excitation level and the specimen behaves significantly in a nonlinear manner under safe shutdown earthquake motion in Korea. The main sources of the nonlinear behavior of the specimen have been judged by friction forces and geometrical nonlinearity rather than material nonlinearity. The nonlinear variation of the dynamic characteristics of the electrical cabinet might be accepted as an important fact that should be considered during the SQ of safety related equipment.

An Experimental Study on Seismic Damage Indicator Considering Cumulative Absolute Velocity Concept (누적절대속도 개념을 고려한 지진손상표시기의 실험적 연구)

  • 이종림;권기주;이상훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.3
    • /
    • pp.65-71
    • /
    • 2001
  • The nuclear power plant(NPP) should be shut down for inspection and tests prior to a return to power if the earthquake exceeds the operating basis earthquake(OBE). The OBE at the plant is considered to have been exceeded if the computed cumulative absolute velocity(CAV) from the earthquake record is greater than 0.16g-sec. However, the CAV criterion should be determined considering the seismic and structural characteristics of the plant. An experimental study using shaking table is conducted in this study to evaluate intensity of CAV criterion. Appropriate level of CAV is evaluated based on the test results using the developed seismic damage indicator(SDI) model. The model consists of stacked acrylic cylinders and is developed to behave consistently for each directional seismic load. The result of the experimental study in dicates that the CAV criterion of 0.16g-sec is conservative enough to be applied to Korean NPPs since the CAV value of the seismic input motion of the Korean standard NPPs ranges from 0.3 to 0.5 g-sec. The developed SDI is expected to be useful not only in easily determining OBE exceedance but also in evaluating earthquake damage quantitatively to provide guidelines for better post-shutdown inspection and test.

  • PDF

Safety Assessment for the self-disposal plan of clearance radioactive waste after nuclear power plant decommissioning (원전해체후 규제해제 콘크리트 방사성 폐기물의 자체처분을 위한 안전성 평가)

  • Choi, YoungHwan;Ko, JaeHun;Lee, DongGyu;Kim, HaeWoong;Park, KwangSoo;Sohn, HeeDong
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.63-74
    • /
    • 2020
  • The Kori-Unit 1 nuclear power plant, which is scheduled for decommissioning after permanent shutdown, is expected to generate a large amount of various types of radioactive waste during decommissioning process. For concrete radioactive waste, which is expected to occupy the most amount, it is important to analyze the current waste disposal status and legal limitations and to prepare an appropriate and efficient disposal method. Concrete radioactive waste is waste of various levels, of which the clearance level is bioshield concrete. In this paper, clearance radioactive waste safety evaluation was performed using the RESRAD code, which is a safety evaluation code, based on the activation evaluation results for the wastes with the clearance level. The clearance scenario of the target radioactive waste was selected and the individual's exposure dose was calculated at the time of clearance to determine whether the clearance criteria limit prescribed by the Nuclear Safety Act was satisfied. As a result of the evaluation, the results showed significantly lower results and satisfied the criteria value. Based on the results of this clearance safety assessment, the appropriate disposal method for bioshield concrete, which are the clearance wastes of subject of deregulation, was suggested.

Development of an Acceptance Criteria Implementation Flow Chart for verifying the Disposal Suitability of Radioactive Waste from Decommissioning of Nuclear Power Plants (원자력발전소 해체 방사성폐기물 처분 적합성 검증을 위한 인수기준 이행 흐름도 개발)

  • Kim, Chang Lak;Lee, Sun Kee;Kim, Heon;Sung, Suk Hyun;Park, Hae Soo;Kong, Chang Sig
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.1
    • /
    • pp.65-75
    • /
    • 2021
  • When the decommissioning of South Korea nuclear power plants is promoted in earnest with the permanent shutdown of Kori Unit 1 in 2017, a large amount of various types of radioactive waste will be generated. For minimal generation and safe management of decommissioning waste, the waste should be made by appropriate classification of the dismantling waste characteristics in accordance with physical, chemical and radiological characteristics to meet the acceptance criteria of disposal facilities. Replacing the preliminary inspection at the site for the compliance of the waste acceptance criteria (WAC) of medium and low-level radioactive waste with the generator's own radioactive waste certification program (WCP), from the perspective of disposal, the optimization of waste management at the national level contributes to the efficient availability of disposal, such as the processing of non-conforming radioactive wastes at the site. To this end, it is important to evaluate radioactivity in each system and area such as nuclear reactors before decommissioning is carried out in earnest, and the prior removal of harmful wastes is important. From waste collection to waste disposal, decommissioning waste should be managed at each stage in consideration of the acceptance criteria of disposal facilities to minimize the generation of non-conforming waste.

Review for Applying Spent Fuel Pool Island (SFPI) during Decommissioning in Korea (원전해체시 독립된 사용후핵연료저장조 국내 적용 검토)

  • Baik, Jun-ki;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.2
    • /
    • pp.163-169
    • /
    • 2015
  • In many nuclear power plant sites in Korea, high density storage racks were installed in the spent fuel pool to expand the spent fuel storage capacity. Nevertheless, the capability of the Hanbit nuclear site will be saturated by 2024. Also, 10 NPPs will reach their design life expiration date by 2029. In the case of the US, SFPI (Spent Fuel Pool Island) operated temporarily as a spent fuel storage option before spent nuclear fuels were transported to an interim storage facility or a final disposal facility. As a spent fuel storage option after shutdown during decommissioning, the SFPI concept can be expected to have the following effects: reduced occupational exposure, lower cost of operation, strengthened safety, and so on. This paper presents a case study associated with the regulations, operating experiences, and systems of SFPI in the US. In conclusion, the following steps are recommended for applying SFPI during decommissioning in Korea: confirmation of design change scope of SFPI and expected final cost, the submission of a decommissioning plan which is reflected in SFPI improvement plans, safety assessment using PSR, application of an operating license change for design change, regulatory body review and approval, design change, inspection by the regulatory body, education and commissioning for SFPI, SFPI operation and periodic inspection, and dismantling of SFPI.

Field Loss Analysis and Cooling Analysis of HTS Synchronous Motor (고온초전도 동기모터의 계자손실 해석 및 냉각 해석)

  • Kim, Ki-Chan;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

Acoustic Emission Monitoring of Incipient Failure in Journal Bearing Part II : Intervention of Foreign Particles in Lubrication (음향방출을 이용한 저어널 베어링의 조기파손감지(II) - 윤활유 이물질 혼입의 영향 및 감시 -)

  • Yoon, Dong-Jin;Kwon, Oh-Yang;Jung, Min-Hwa;Kim, Kyung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.122-131
    • /
    • 1994
  • Journal bearings in the rotating machineries are vulnerable to the contamination or the insufficient supply of lubricating oil, which is likely to be the cause of unexpected shutdown or malfunction of these systems. Various destructive and nondestructive testing methods had been used for the reduction of maintenance cost and the operational safety problems due to the accidents related to bearing damages. In this experimental approach, acoustic emission monitoring is employed to the detection of incipient failure caused by intervention of foreign particles most probable in the journal bearing systems. Experimental schedules for the intervention of foreign particles was composed to be more quantitative and systematic than last study in consideration of minimum oil film thickness and particle size. The experiment was conducted under such designed conditions as inserting alumina particles to the lubrication layer in the simulated journal bearing system. Several parameters such as AE rms level, waveform, AE energy distribution and other AE event parameters are used for analysis and characterization of damage source. The results showed that the history of damage was well correlated with the changes of AE rms level and the type of damage source signal can be verified using other informations such as waveform, distributions of AE parameters etc.

  • PDF