• Title/Summary/Keyword: power plant B

Search Result 384, Processing Time 0.033 seconds

Development of Performance Analysis Methodology for Nuclear Power Plant Turbine Cycle Using Validation Model of Performance Measurements (원전 터빈사이클 성능 데이터의 검증 모델에 의한 성능분석 기법의 개발)

  • Kim, Seong-Geun;Choe, Gwang-Hui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1625-1634
    • /
    • 2000
  • Verification of measurements is required for precise evaluation of turbine cycle performance in nuclear power plant. We assumed that initial acceptance data and design data of the plant could provide correlation information between performance data. The data can be used as sample sets for the correct estimation model of measurement value. The modeling was done practically by using regression model based on plant design data, plant acceptance data and verified plant performance data of domestic nuclear power plant. We can construct more robust performance analysis system for an operation nuclear power plant with this validation scheme.

Experimental Study on the Shrinkage Properties and Cracking Potential of High Strength Concrete Containing Industrial By-Products for Nuclear Power Plant Concrete

  • Kim, Baek-Joong;Yi, Chongku
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.224-233
    • /
    • 2017
  • In Korea, attempts have been made to develop high strength concrete for the safety and design life improvement of nuclear power plants. In this study, the cracking potentials of nuclear power plant-high strength concretes (NPP-HSCs) containing industrial by-products with W/B 0.34 and W/B 0.28, which are being reviewed for their application in the construction of containment structures, were evaluated through autogenous shrinkage, unrestrained drying shrinkage, and restrained drying shrinkage experiments. The cracking potentials of the NPP-HSCs with W/B 0.34 and W/B 0.28 were in the order of 0.34FA25 > 0.34FA25BFS25 > 0.34BFS50 > 0.34BFS65SF5 and 0.28FA25SF5 >> 0.28BFS65SF5 > 0.28BFS45SF5 > 0.28 FA20BFS25SF5, respectively. The cracking potentials of the seven mix proportions excluding 0.28FA25SF5 were lower than that of the existing nuclear power plant concrete; thus, the durability of a nuclear power plant against shrinkage cracking could be improved by applying the seven mix proportions with low cracking potentials.

Total management and support system for telecommunication power plant (통신용 전원 종합관리시스템)

  • Park, K.G.;Cho, I.K.;Min, B.R.;Park, B.J.;Ahn, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3169-3171
    • /
    • 1999
  • One of the important purposes o Telecommunications power plant operation is to supply safe power for maintaining the reliable communication services. Therefore, the power plant operation support system is generally used for efficient and maintenance of power plant without the increment of the operation and maintenance staffs. To operate and maintain a number of power plants efficiently, Korea Telecom developed centralized power plant monitoring and control system. In this paper, the system feature and main functions are described.

  • PDF

Study on a Development of the Prediction Equation of the Wind Power Plant Noise (풍력발전소 소음 영향 예측식 개발에 관한 연구)

  • Gu, Jinhoi;Lee, Jaewon;Lee, Woo Seok;Jung, Sungsoo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.1
    • /
    • pp.49-54
    • /
    • 2016
  • The wind power plants were installed in many places because of the low climate changing effects since 2000. Generally, the wind power plants located in the seaside and the mountainous area and the heights of the windmills are about 40 m~140 m above the ground level. So the noises emitted from the wind power plants propagate far away compared with other environment noise sources like trains and cars noise. Because of these reasons, the noise emitted from the wind power plant is easy to cause the additional social problems like as noise complaints. Under the situation, the ministry of environment has established the guideline to evaluate the environmental effects for the wind power plant. According to the guideline, the noise of the wind power plant has to meet 55 dB(A) at daytime and 45 dB(A) at night in the residential area, which is regulated in the noise and vibration management law. But, it is difficult to estimate the noise emitted from the wind power plant because of the absence of the prediction model of the wind power plant noise. Therefore, the noise prediction model for wind power plants using the regression analysis method is developed in this study. For the development of the model, the sound pressure levels of the wind power plants in Jeju island are measured and the correlations between the sound pressure levels are analyzed. Finally, the prediction equation of the wind power plant noise using by regression analysis method derived. The prediction equation for the wind power plant noise proposed in this study can be useful to evaluate the environmental effects in any wind power plant development district.

A Study on the Workplace Noise Environment of Office Areas in Power Plant (발전소 관리실의 작업환경 소음에 관한 연구)

  • 김병삼
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.4
    • /
    • pp.35-41
    • /
    • 1998
  • The workplace noise environment is composed of three basic elements : manufacturing (in a generic sense) facilities, office areas, and the community around the facility. Work must be done by all employees , and this involves communication within a variety of locations within the facility ; areas may be extremely noisy, moderately noisy, or quiet, such as an office. At the same time, the facility should not be annoying to the community. In this paper, the workplace environmental noise of office areas in power plant are studied. Turbine generator in power plant generates the noise of 90∼95 dB(A) in the frequency range of 1 kHz, which may cause occupational hearing loss. By abatement method which are made of isolation material and distance damping effect, about 29.5 dB(A) reduction has been obtained in office areas of the Power Plant . But, the workplace environmental noise of office areas in the power plant is not suited to office's purpose.

FMEA for Facility Reliability Analysis of A Hydro-power Plant (수력발전소 설비 신뢰성 분석을 위한 FMEA)

  • Kwon, Chang-Seob;Jeon, Tae-Bo
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.135-144
    • /
    • 2006
  • The significance of hydro-power plant is increasing in its public roles such as flood control and water supply as well as electric power production. Even if high level of reliability in facility operation is required, no specific reliability research has been made. This specifically stems from the lack of technology and research investments. The eventual goal of this study is to secure a methodology for reliability analysis of hydro-power plant so that an appropriate decision for operation and investment can be made. Specific effort was put to develop a reliability model for water supply system within hydro-power plant. For this study, we briefly examined the overview of the hydro-power plant including the electric power generation facility system. We then discussed the facility reliability analysis methodology for hydro-power plant. Based on rigorous examination of the water supply system and components roles, we drew major failure modes for each component and examined their effects.

  • PDF

A Study on the Evaluation of Turbine Efficiency through the Performance Test of New Power Plant (신규 화력발전소의 성능 시험을 통한 터빈 효율의 평가에 관한 연구)

  • Kweon, Y.S.;Chung, H.T.;Jung, Y.B.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • Super-critical type steam power plant, which operates with steam pressure above the super-critical point, has a good reputation recently and is adopted as a new standard of the Korean Electric Power Corporation. The reason for the good reputation lies in it's superior power efficiency. However, the field data of the new power plant for the verification of it's performance are still insufficient, and more empirical data are needed to acquire technologies on the effective operation of it. In this study, the authors analyzed the field test data on power efficiencies got in a super-critical type steam power plant, and evaluated the excellency of the new plant by comparing the efficiency data with the one got in a conventional sub-critical type steam power plant.

  • PDF

Phytochemistry and Pharmacology of Moringa oleifera Lam

  • Paikra, Birendra Kumar;Dhongade, Hemant kumar J.;Gidwani, Bina
    • Journal of Pharmacopuncture
    • /
    • v.20 no.3
    • /
    • pp.194-200
    • /
    • 2017
  • Moringa oleifera Lam. or munga is one of the most important plant widely cultivated in India. It belongs to family Moringaceae. This plant is widely used as nutritional herb and contains valuable pharmacological action like anti-asthmatic, anti-diabetic, hepatoprotective, anti-inflammatory, anti-fertility, anti-cancer, anti-microbial, anti-oxidant, cardiovascular, anti-ulcer, CNS activity, anti-allergic, wound healing, analgesic, and antipyretic activity, Moringa oleifera Lam. The plant is also known as Horse - radish tree, Drumstick tree. Every part of this plant contains a valuable medicinal feature. It contain rich source of the vitamin A, vitamin C and milk protein. Different types of active phytoconstituents like alkaloids, protein, quinine, saponins, flavonoids, tannin, steroids, glycosides, fixed oil and fats are present. This plant is also found in the tropical regions. Some other constituents are niazinin A, niazinin B and niazimicin A, niaziminin B. The present review discusses the phytochemical composition, medicinal uses & pharmacological activity of this plant.

Exergetic and Thermoeconomic Analysis of Steam Power Plant (스팀 동력 플랜트의 엑서지 및 열경제학적 해석)

  • Kim, Duck-Jin;Jung, Jung-Yeul;Kwak, Ho-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.1
    • /
    • pp.76-83
    • /
    • 2003
  • Exergetic and thermoeconomic analyses were performed fer a 137-MW steam power plant. In these analyses, mass and energy conservation laws were applied to each component of the system. Quantitative balance of the exergy and exergetic cost for each component, and for the whole system was carefully considered. The exergo-economic model, which represented the productive structure of the system was used to visualize the cost formation process and the productive interaction between components. The computer program developed in this study can determine production costs of power plants, such as gas-and steam-turbines plants and gas-turbine cogeneration plants. The program can also be used to study plant characteristics, namely, thermodynamic performance and sensitivity to changes in process and/or component design variables.

A Study on the Automatic Start-up of a Drum-type Boiler Using Fuzzy Logic (퍼지 논리를 이용한 드럼형 보일러의 자동기동에 관한 연구)

  • ;;;Zeungnam Bien
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.2
    • /
    • pp.87-96
    • /
    • 1993
  • Because of the complexity, nonlinearity and long-time delay of power plant, the star-up operation of a fossil power plant is very difficult to automate. So the start-up operation is always carried out by the skilled human operators, who utilize their knowledges and experiences for the predesigned start-up schedules and procedures. In this paper, a fuzzy logic controller is designed for the start-up operation of the power plant. And the operators experiences are modeled in terms of fuzzy sets and variables. To validate the controller, a drum-type boiler of the Seoul Power Plant is constructed via the signal flow diagram. Using the model, the suggested automatic start-up operation is verified, and the results are also presented.

  • PDF