• 제목/요약/키워드: power performance

검색결과 17,150건 처리시간 0.051초

신규 화력발전소의 성능 시험을 통한 터빈 효율의 평가에 관한 연구 (A Study on the Evaluation of Turbine Efficiency through the Performance Test of New Power Plant)

  • 권영수;정희택;정양범
    • 동력기계공학회지
    • /
    • 제5권1호
    • /
    • pp.11-20
    • /
    • 2001
  • Super-critical type steam power plant, which operates with steam pressure above the super-critical point, has a good reputation recently and is adopted as a new standard of the Korean Electric Power Corporation. The reason for the good reputation lies in it's superior power efficiency. However, the field data of the new power plant for the verification of it's performance are still insufficient, and more empirical data are needed to acquire technologies on the effective operation of it. In this study, the authors analyzed the field test data on power efficiencies got in a super-critical type steam power plant, and evaluated the excellency of the new plant by comparing the efficiency data with the one got in a conventional sub-critical type steam power plant.

  • PDF

Modeling of a Variable Speed Wind Turbine in Dynamic Analysis

  • Kim, Seul-Ki;Kim, Eung-Sang;Jeon, Jin-Hong
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권2호
    • /
    • pp.51-57
    • /
    • 2004
  • This paper describes the dynamic performance of a variable speed wind turbine system responding to a wide variety of wind variations. Modeling of the wind generation using power electronics interface is proposed for dynamic simulation analysis. Component models and equations are addressed and their incorporations into a transient analysis program, PSCAD/EMTDC are provided. A wind model of four components is described, which enables observing dynamic behaviors of the wind turbine resulting from wind variations. Controllable power inverter strategies are intended for capturing the maximum power under variable speed operation and maintaining reactive power generation at a pre-determined level for constant power factor control or voltage regulation control. The components and control schemes are modeled by user-defined functions. Simulation case studies provide variable speed wind generator dynamic performance for changes in wind speed

크로스핏 파워 트레이닝이 TPI OnBaseU Power Test와 골프 수행력에 미치는 영향 (Effect of CrossFit Power Training on TPI OnBaseU Power Test and Golf Performance)

  • Chang Wook Kim
    • 한국운동역학회지
    • /
    • 제33권4호
    • /
    • pp.185-195
    • /
    • 2023
  • Objective: The purpose of this study is to improve TPI OnBaseU Power Test and golf performance by conducting CrossFit power training. Method: Three male golf players from University B participated in this study. They had 3 to 4 years of golf experience and participated in 8 weeks of CrossFit power training. Results: OnBaseU Power Test: There was a lot of improvement in Sit up throw (27.9%) and Chest pass (10.58%), but there was not much improvement in Baseline Toss (R5.9, L9.8%) and Vertical Jump (4.1%). Golf shot data: There was a very statistically significant difference in Club speed, Ball speed, and Total Length, which are related to speed, and there was no difference in Club path and Smash factor, which are related to accuracy and posture. Conclusion: CrossFit power training was effective in improving TPI OnBaseU Power Test and golf performance (Club speed, Ball speed, Total Length).

3차원 소형축류홴의 공력특성에 대한 난류모델평가 (Evaluation of the Turbulence Models on the Aerodynamic Performance of Three-Dimensional Small-Size Axial Fan)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.13-20
    • /
    • 2014
  • The steady-state, incompressible and three-dimensional numerical analysis was carried out to evaluate turbulent models on the aerodynamic performance of a small-size axial fan(SSAF). The prediction performance on the static pressure of all turbulent models is going downhill at the high static pressure and low flowrate region, but has improved at the axial flow region. In consequence, all turbulent models predict the static pressure coefficient with an error performance less than about 4% after the region of the flowrate coefficient of about 0.14. Especially, the turbulent model of SST $k-{\omega}$ shows the best prediction performance equivalent to an error performance less than about 2% on the static pressure.

능동전력필터의 간단한 순시전력이론과 수정된 보상성능 평가법 (A Simple Instantaneous Power Theory and Modified Compensation Performance Evaluation of Active Power Filters)

  • 정영국;유광호;김영철;양승학;김우용;임영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2549-2552
    • /
    • 1999
  • The fictitious power theory in time domain is very easy to understand, but power analyzing time of active power is increased, because power is analyzed using signal techniques based on the correlation between voltage and current waveforms. Also, conventional methods in time/frequency domain to evaluate the compensation performance of active power filters are not provided easy solutions. So, the authors have previously proposed 3-D current coordinates which is composed into active component, fundamental reactive component and distorted component of nonlinear loads current. This method has excellent performance, but can not evaluate the characteristics of nonlinear load current whether inductive or capacitive. Therefore, To overcome problems mentioned previously, this paper deals with the simple instantaneous power theory and the modified 3-D current coordinates for evaluating the compensation performance of active power filters. To confirm the validity, active power filters simulator is developed using C-language. From the simulation, results are discussed their utility.

  • PDF

3MW 풍력발전시스템 출력성능평가에 관한 연구 (The Power Performance Testing for 3MW Wind turbine System)

  • 고석환;장문석;박종포;이윤섭
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.19-26
    • /
    • 2011
  • We are carried out power performance testing for 3MW wind turbine system at Je-ju wind turbine testing Site and analyzed measured data which was stored through monitoring system. In this paper, we described the power performance testing results and analyzed an uncertainty of measured data sets. The power curve with measured power data is closely coincide with designed power curve except for the low wind speed sections(4m/s~7m/s) and the annual energy production which is given Ray leigh distribution was included with 1.5~5.9% of uncertainty in the wind speed region as 4~11m/s. Although the deviation of curve between measured power and designed power is high, the difference of annual energy production is low in the low wind speed region.

Syngas및 수소를 연료로 사용하는 발전용 가스터빈 성능해석 (Performance Analysis of a Gas Turbine for Power Generation using Syngas as a Fuel)

  • 이종준;차규상;손정락;김동섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3241-3246
    • /
    • 2007
  • Integrated Gasification Combined Cycle (IGCC) power plant converts coal to syngas, which is mainly composed with hydrogen and carbon monoxide, by the gasification process and produces electric power by the gas and steam turbine combined cycle power plant. The purpose of this study is to investigate the influence of the syngas to the performance of a gas turbine in a combined cycle power plant. For this purpose, a commercial gas turbine is selected and its performance characteristics are analyzed with three different fuels, i.e., natural gas ($CH_4$), syngas and hydrogen. It is found that different heating values of those fuels and chemical compositions in their combustion gases are the causes in the different performance characteristics.

  • PDF

Solid Oxide Fuel Cells for Power Generation and Hydrogen Production

  • Minh, Nguyen Q.
    • 한국세라믹학회지
    • /
    • 제47권1호
    • /
    • pp.1-7
    • /
    • 2010
  • Solid oxide fuel cells (SOFCs) have been under development for a variety of power generation applications. Power system sizes considered range from small watt-size units (e.g., 50-W portable devices) to very large multi-megawatt systems (e.g., 500-MW base load power plants). Because of the reversibility of its operation, the SOFC has also been developed to operate under reverse or electrolysis mode for hydrogen production from steam (In this case, the cell is referred to as solid oxide electrolysis cell or SOEC.). Potential applications for the SOEC include on-site and large-scale hydrogen production. One critical requirement for practical uses of these systems is long-term performance stability under specified operating conditions. Intrinsic material properties and operating environments can have significant effects on cell performance stability, thus performance degradation rate. This paper discusses potential applications of the SOFC/SOEC, technological status and current research and development (R&D) direction, and certain aspects of long-term performance degradation in the operation of SOFCs/SOECs for power generation/hydrogen production.

태양광 발전의 MPPT 성능 개선을 위한 변형된 PO 방법 (Modified-PO Method to Improve the MPPT Performance of PV System)

  • 고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.40-46
    • /
    • 2015
  • This paper proposes the method which is improved a performance of PO MPPT control in PV system. The PO method is continually changed voltage toward direction that increases power, and if output power is decreased by changing voltage, a power of the conventional PO method is changed to a power before one step. These operations causes reduce of MPPT performance. Therefore, this paper proposes the MPPT method that can be improved the performance of the conventional PO method. When voltage is changed to direction of reducing power, the method proposed in this paper is changed to the voltage the opposite direction of twice step size. The MPPT performance of proposed method in this paper is compared with conventional PO method and proved the validity of this paper using these results.

Performance Analysis of NOMA with Symmetric Superposition Coding

  • Chung, Kyuhyuk
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.314-317
    • /
    • 2019
  • Recently, the symmetric superposition coding (SSC) [3] is proposed for a solution for the error propagation (EP) due to the non-perfect successive interference cancelation (SIC) in non-orthogonal multiple access (NOMA). We analyze the performance of NOMA with the SSC. It is shown that the performance of the SSC NOMA is the same as that of NOMA with the normal superposition coding (NSC) for the power allocation factor less than 20%, the SSC NOMA performance is better than the NSC NOMA performance up to the power allocation factor 80%, and the SSC NOMA performs worse than the NSC NOMA for the power allocation factor greater than 80%. As a result, the SSC should be used with consideration of the power allocation.