• Title/Summary/Keyword: power line signal

Search Result 641, Processing Time 0.026 seconds

Simulation for PLC using Matlab (Matlab을 이용한 전력선 통신 시뮬레이션)

  • Hong, Duc-Pyo;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1002-1003
    • /
    • 2006
  • Power line communication: PLC which easy to install at anywhere near outlet for electric machine. PLC uses transmission line for voltage of which is 60 Hz. One of the important thing is the processes of adding signal to power line and extracting the signal from power line, another is to choose the strong modulation method which sends signals to long distance without loosing in PLC channel. but PLC channel have very high and variable noise and attenuation and then it is very hard to transmit optimally between the transmitter and the receiver. AWGN, impulse noise and attenuation are created. To overcome the noise and attenuation. Multi-carrier Modulation methods like as OFDM and DMT which divide the channel into many sub-channel are powerful communication methods for PLC. In this paper, PLC channels are simulated for getting BER by Matlab simulink

  • PDF

Design and Implementation of the Basic Technology for Solitary Senior Citizen's Lonely Death Monitor ing System using PLC

  • Huh, Jun-Ho;Seo, Kyungryong
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.6
    • /
    • pp.742-752
    • /
    • 2015
  • The communications through the power lines are called as the PLC and this is a common name for the communication modes for the information delivery. This technology transmits the data through the power lines on which the information is stored with the form of high frequency signal. The characteristic of the frequency signal is that the signal can be separated from the power line through exclusive power line modem and transmitted to the terminal devices. In this paper, 'In-home Headcount' checking algorithm using Wi-Fi and taking above mentioned advantages is proposed, and the basic Technology for such Solitary Senior Citizen's Lonely Death monitoring system has been designed and implemented. The comparative analysis has been conducted in this paper with the test-operated and test bed-completed 'Hyosimi 119 Safety-Welfare System' which is still being tested since 2008. With the 'In-home Headcount Checking Algorithm', Wi-Fi connection/disconnection status and SSIDs of relevant Wi-Fis will be checked. We expect that our proposed method will become as the basic Technology which can prevent lonely deaths of elderly people living alone. Since the PLC technology can be normally implement all the functions used on internet anticipate that the technology could be applied to many areas to construct a new form of communication network.

Spread Spectrum Method based Power Line Communication for Plant Monitoring and Control System (전력선 통신을 이용한 plant 감시 제어 시스템)

  • 서민상;성석경;안병규
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.211-215
    • /
    • 1997
  • Localized communication networks for office automation, security monitoring, environmental management of buildings, computer communications, and other applications enjoy every increasing demand. This paper proposes a direct sequence spread spectrum communication system for use in power line data transmission. Advantages of power distribution circuits include reasonably universal coverage and easy access vis a standard wall plug. Disadvantages include limited communication bandwidth, relatively high noise levels, and varying levels of impedance, noise, and attenuation. Spread spectrum signalling provides immunity to narrow-band signal impairments and multiplexing capability. Our prototype power line communication module supports completely physical and data link layers based on the international standard ISO 10368 for reliable high-speed power line communication system. Moreover it provides useful functions to compose a plant monitoring and control system. All the circuits of the communication module are included in one compact circuit. Thus a functional communication system for the power line plant monitoring and control is implemented.

  • PDF

Development of the line coupler for reliable power line communication system (신뢰적인 전력선 통신을 위한 라인 커플러의 개발)

  • Choi, Won-Ho;Im, Byoung-No;Park, Chong-Yeun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2009-2010
    • /
    • 2006
  • This paper presents an adaptive line coupler to match input impedance of the Power line Communication(PLC) modem between access impedance of the power line. This line coupler provides maximum signal power transmiting capability, high reliability. The structure of this coupler is simple and designed to make a easy and low cost. The proposed line coupler is suitable for Amplitude Shift Keying(ASK) or Phase Shift Keying(PSK) modem. To figure out our models, the analysis of the transmitting features of power line channel is performed in the time domain at the carrier frequency. As a result of this study, we present the values of capacitors in the capacitor bank and adaptive line coupler circuit.

  • PDF

Realization of the Transmitter of Communication Modem for Control Systems using Power-Distribution Circuit (전력선 버스를 이용한 제어 시스템의 통신모뎀 송신기 구현에 관한 연구)

  • Chung, Chang-Kyung;Park, Young-Chull;Sohn, Dong-Sup
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.330-335
    • /
    • 1999
  • Recently, there a lot of activities on the researches that implement many kinds of control system using power lines. To implement that, it is desirable to use hybrid PSK model because it takes advantage of PSK and DPSK which has a low-bit-error rate. In this parer, we implement the transmitter of this model. Because the power line is not designed for the data communication, we separated the signal generator circuit and the signal loading circuit so that minimized noises from outside. Also, to make it easy on the experiments, most of process are performed by software. As a result, transmitting a high frequency signal on the power line made no effects on the electrical devices.

  • PDF

Signal Transmission Characteristic of PLC Coupler using Tank Circuit (Tank회로를 이용한 배전선신호 결합장치의 특성분석)

  • Kim, J.S;Kye, M.H.;Yoo, D.W.;Oh, S.C.;Kim, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.809-811
    • /
    • 1993
  • The load impedance of power lines generally varies with time, areas, and season. Also, the harmonic noises by the power electrical equipments are scattered through the power lines. The received signal level varies with the environment and is not able to detect the PLC(Power Line Carrier) signal. For this reason, it is requried for the signal transmitter to hold the received signal level uniform independently with the variation of the load impedence. In this paper, the power lines are modeled simply and a method keeping the received signal level uniform is suggested through the analysis of the signal transmission characteritics of the PLC coupler using tank circuit.

  • PDF

A Study on the Signal Anti-reduction Equipment in Power Line Communication (전력선 통신 시스템을 위한 신호 감쇠 저하 장치 연구)

  • 김주환
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.103-106
    • /
    • 2000
  • In this paper a communication system that is not using the communication line but power line is presented. It will be very useful for an information-oriented society with tele-metering and home automation. Conventional system has a difficulty in transmitting information due to decreasing communication voltage and increasing carrier, current. Proposed idea is a special type switching amplifier system which has a low inner resistance. It can provide reactive power and dose not have low impedance between the transceivers. This new system is proposed to overcome the loss of conductor load in a PLC system.

  • PDF

OFDM Modulation Transmission Characteristic of Acoustic Signal on Power Line Channel (전력선 채널에서 음향신호의 OFDM 변조 전송 특성)

  • Heo, Yoon-Seok
    • The Journal of Information Technology
    • /
    • v.6 no.4
    • /
    • pp.1-9
    • /
    • 2003
  • This paper is about power line communication(PLC) over the low power voltage grid. The main advantage with power line communication is the use of an existing infrastructure. The PLC channel can be modeled as having multi-path propagation with frequency-selective fading, typical power lines exhibit signal attenuation increasing with length and frequency. OFDM(Orthogonal Frequency Division Multiplexing) is a modulation technique where multiple low data rate carriers are combined by a transmitter to form a composite high data rate transmission. The performance in consideration of the multi-path(echoes) powerline scheme is analyzed and verified by computer simulation.

  • PDF

Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication (고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구)

  • 이재조;유정훈;홍충선;이대영
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.5
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

Implementation of Zero-Ripple Line Current Induction Cooker using Class-D Current-Source Resonant Inverter with Parallel-Load Network Parameters under Large-Signal Excitation

  • Ekkaravarodome, Chainarin;Thounthong, Phatiphat;Jirasereeamornkul, Kamon
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1251-1264
    • /
    • 2018
  • The systematic and effective design method of a Class-D current-source resonant inverter for use in an induction cooker with zero-ripple line current is presented. The design procedure is based on the principle of the Class-D current-source resonant inverter with a simplified load network model that is a parallel equivalent circuit. An induction load characterization is obtained from a large-signal excitation test-bench based on parallel load network, which is the key to an accurate design for the induction cooker system. Accordingly, the proposed scheme provides a systematic, precise, and feasible solution than the existing design method based on series-parallel load network under low-signal excitation. Moreover, a zero-ripple condition of utility-line input current is naturally preserved without any extra circuit or control. Meanwhile, a differential-mode input electromagnetic interference (EMI) filter can be eliminated, high power quality in utility-line can be obtained, and a standard-recovery diode of bridge-rectifier can be employed. The step-by-step design procedure explained with design example. The devices stress and power loss analysis of induction cooker with a parallel load network under large-signal excitation are described. A 2,500-W laboratory prototype was developed for $220-V_{rms}/50-Hz$ utility-line to verify the theoretical analysis. An efficiency of the prototype is 96% at full load.