• Title/Summary/Keyword: power line inspection

Search Result 87, Processing Time 0.026 seconds

Nonlinear Flexural Analysis of PSC Test Beams in CANDU Nuclear Power Plants

  • Bae, In-Hwan;Choi, In-Kil;Seo, Jeong-Moon
    • Nuclear Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.180-190
    • /
    • 2000
  • In this study, nonlinear analyses of prestressed concrete(PSC) test beams for inservice inspection of prestressed concrete containments for CANDU nuclear power plants are presented. In the analysis the material nonlinearities of concrete, rebar and prestressing steel are used. To reduce the numerical instability with respect to the used finite element mesh size, the tension stiffening effect has been considered. For concrete, the tensile stress-strain relationship derived from tests is modified and the stress-strain curve of rebar is assumed as a simple bilinear model. The stress-strain curve of prestressing steel is applied as a multilineal curve with the first straight line up to 0.8fpu. To prove the validity of the applied material models, the behavior and strength of the PSC test specimens tested to failure have been evaluated. A reasonable agreement between the experimental results and the predictions is obtained. Parametric studies on the tension stiffening effects, the impact of prestressing losses with time, and the compressive strength of concrete have been conducted.

  • PDF

Development of overhead distribution line diagnosis system program (가공 배전선로 진단시스템 프로그램 개발)

  • Dong Hyun Chung;Deok Jin Lee
    • Smart Media Journal
    • /
    • v.12 no.5
    • /
    • pp.81-87
    • /
    • 2023
  • In this paper, accidents in high-voltage overhead distribution lines, which provide stable power supply in the power system, cause inconvenience in life and disruption of production of companies. 22.9 [kV] high-voltage overhead power distribution lines aim to improve reliability and stability, such as damage caused by rain, snow, wind, etc., or electric shock prevention. Therefore, in order to prevent wire disconnection accidents due to deterioration of electrical conductivity or tensile strength due to corrosion of overhead distribution lines, it is necessary to prevent unexpected accidents in the future through regular inspection and repair. In order to diagnose deterioration due to corrosion of distribution lines, a diagnostic system (measuring instrument) is installed on the wires to monitor the condition of the wires. The manager on the ground receives the measured data through ZigBee wireless communication, controls the diagnosis system through the diagnosis system program, and grasps the condition of the overhead distribution line through the measured data and photographed photos, and predicts the life of the wire along with the visual inspection method. developed a program.

Design of Leakage Current Detecting Equipment of an Arrester Diagnostic Type in a Distribution Line (배전선로용 피뢰기 진단형 누설전류 검출장치 설계)

  • Yoon, Gi-Gab;Park, Jong-Beom;Yoon, Suk-Mu;Lee, Seung-Hak;Kim, Hong-Pil;Kim, Kwang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.501-503
    • /
    • 2000
  • Since an arrester has been generally used at the distribution line and abroad for the protection of electrical equipments against overvoltage (or abnormal surge) taking place in or from an electrical system, a fault, especially, in the distribution line is very likely to result in the destruction of insulation of other protection devices to cause an overall paralysis of a power system, a chaos. Considering the importance of arresters, its earlier replacement than its proposed life cycle causes an economical loss, and a negligence not to replace or repair it in time gives rise to a crucial accidence. The purpose of this paper is to invent an electric leakage current detector and to solve such problems by the continuous and regular inspection of an arrester.

  • PDF

Degradation Diagnosis of Overhead Power Lines Using Eddy Current Technology (와전류 기법을 이용한 가공전력선 열화 진단)

  • Kim, Chng-Hyeok;Kim, Tag-Yong;Oh, Yong-Cheul;Choi, Woon-Sik;Jo, Choon-Nam
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.5
    • /
    • pp.322-327
    • /
    • 2014
  • Internal corrosion of the distribution line can be detected in order to develop techniques of non-destructive inspection methods that operate only on the metal track eddy current diagnosis is possible by applying the technique investigated. Sensor for the production of a finite element method modeled by using an eddy current sensor, a distribution line by using an accelerated aging samples of sodium hydroxide was prepared. Sheathed cables for internal corrosion studies detected using an eddy current sensor is considered to be possible.

Flaw Sizing by ASME and CSA Code (ASME 및 CSA 코드에 의한 초음파 결함 크기 측정)

  • Park, Moon-Ho;Kang, Suk-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.4
    • /
    • pp.313-320
    • /
    • 1998
  • To record and evaluate the flaws which were found during pre-service/in-service inspection performance of nuclear power plants in Korea, the center line beam method described in ASME code and 6 dB drop method stated in CSA code were used. The measured through wall dimensions and lengths by these methods were compared and analyzed in this report. With the measured data analysis, the ekact understanding and use of these methods improves the reliability of flaw sizing and assures the integrity of nuclear power plant components.

  • PDF

A RULE-BASED APPROACH for AUTOMATIC CONTINGENCY SELECTION in POWER SYSTEMS (자동 상정사고 선택에 관한 룰-베이스적 접근)

  • Park, Young-Moon;Shin, Joong-Rin;Jo, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.118-121
    • /
    • 1987
  • This paper presents a rule-based approach for automatically selecting critical contingencies in electric power systems. The rules required to perform the task are derived from inspection about results of simulation and expertise of operators. And inherent information of system, for example, topology of system configuration, and flow direction in a line by compensation theorem. etc., which are independent of operating point of system, is stored in the database using the off-line calculation. The approach was investigated using the study of a sample test system. Since it is based on the knowledge engineering technique, efficiency of selection can be improved by updating and adding the rules.

  • PDF

Active Vibration Measuring Sensor for Nondestructive Test of Electric Power Transmission Line Insulators (송전선로 애자의 비파괴 검사를 위한 능동형 진동 측정센서)

  • Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.424-430
    • /
    • 2008
  • A new active vibration measurement system in electric power transmission line is presented, using in the nondestructive test. With a permanent magnet and a couple of coils, the system exerts impact force to a test object and in turn picks up the vibration of the object. The natural frequency with the amplitude obtained from the system are used as a basis for the detection of defects in the object. The system is controlled by an electronic device designed to facilitate the fully automated testing process with consistent repeatability and reliability which are essential to the nondestructive test. The system is expected to be applied to the wide area of defect detection including the classification of mechanical parts in production and inspection processes.

Laser Peening Application for PWR Power Plants (비등수형 원자로 발전소에의 레이저 피닝 적용기술)

  • Kim, Jong-Do;SANO, Yuji
    • Journal of Welding and Joining
    • /
    • v.34 no.5
    • /
    • pp.13-18
    • /
    • 2016
  • Toshiba has developed a laser peening system for PWRs(pressurized water reactors) as well after the one for BWRs(boiling water reactors), and applied it for BMI(bottom-mounted instrumentation) nozzles, core deluge line nozzles and primary water inlet nozzles of Ikata Unit 1 and 2 of Shikoku Electric Power Company since 2004, which are Japanese operating PWR power plants. Laser pulses were delivered through twin optical fibers and irradiated on two portions in parallel to reduce operation time. For BMI nozzles, we developed a tiny irradiation head for small tubes and we peened the inner surface around J-groove welds after laser ultrasonic testing (LUT) as the remote inspection, and we peened the outer surface and the weld for Ikata Unit 2 supplementary. For core deluge line nozzles and primary water inlet nozzles, we peened the inner surface of the dissimilar metal welding, which is of nickel base alloy, joining a safe end and a low alloy metal nozzle. In this paper, the development and the actual application of the laser peening system for PWR power plants will be described.

Experimental Studies on Ultrasonic Guided Waves for the On-Line Inspection of Structural Integrity of Nuclear Power Plants (원전 기기 건전성의 온라인 검사를 위한 유도 초음파의 실험적 연구)

  • Eom, Heung-Seop;Kim, Jae-Hee;Song, Sung-Jin;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.331-340
    • /
    • 2004
  • Deployment of an advanced on-line monitoring of the component integrity offers a prospect of improved performance, enhanced safety, and reduced overall cost for nuclear power plants. Ultrasonic guided waves have been known as one of the promising techniques that could be utilized for on-line monitoring. The present work is aimed at developing a new method for on-line monitoring of the pipes during the operation period of nuclear power plants. For this purpose, the steam generator (S/G) tube was selected as an object of tile experiment. Dispersion corves and the incident angles corresponding to the specific modes were calculated for the S/G tube. The modes of guided waves were identified by the time-frequency diagrams obtained by the short time Fourier transform. It was experimentally confirmed that there was no mode conversion when the ultrasonic guided waves passed over the curved region of the S/G tube. An optimum mode of guided wave for the S/G tube was suggested and verified by the experiment.

Development of On-Line Life Monitoring System for high-Temperature Header of Fossile Powder Plant Boiler (화력발전소 보일러 고온헤더의 실시간 수명 감시시스템 개발)

  • 윤필기;정동관;윤기봉
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.605-611
    • /
    • 1999
  • Conventional methods for assessing remaining life of critical high temperature components in fossil power plants rely on nondestructive inspection practices and accompanying life analysis based on fracture mechanics By using these conventional methods. It has been difficult to perform uninterrupted in-service inspection for life prediction. Thus, efforts have been made for developing on-line remaining life monitoring systems employing information on the shape of structures, operating variables and material properties. In thus study, a software for on-line life monitoring system which performs real-time life evaluation of a high temperature system headers was developed. The software is capable of evaluating creep and fatigue life usage from the real-time stress data calculated by using temperatures/stress transfer Green functions derived in advance for the specific headers. The major benefits of the developed software life in determining future operating schedule, inspection interval, and replacement plan by monitoring real-time life usage based on prior operating history.

  • PDF