• Title/Summary/Keyword: power curve

Search Result 1,251, Processing Time 0.026 seconds

Optimal Location of Meteorological Mast for Power Curve Verification of Wind Farm (풍력단지 출력 검증을 위한 기상탑의 최적위치 선정)

  • Oh, Ki-Yong;Lee, Jun-Shin;Park, Joon-Young;Lee, Jae-Kyung;Kim, Ji-Young
    • New & Renewable Energy
    • /
    • v.5 no.2
    • /
    • pp.31-38
    • /
    • 2009
  • The performance test of a wind turbine in a wind farm is generally carried out by the owner to verify the power curve of the wind turbine given by the turbine manufacturer. The international electro-technical commission provides the IEC 61400-12-1 standard on "Power performance measurements of electricity producing wind turbines". By using this code, one can easily find the suitable met-mast (meteorological mast) location for the wind data whether a wind farm is potential or already built. In this paper, the valid sectors for wind turbines installed in the HanKyoung wind farm, south-west in Jeju island are analyzed on the basis of the code by considering the wind farm layout. Among these sectors, the optimal met-mast location is presented for the power curve verification of the wind farm.

  • PDF

Wind Turbine Power Performance Testing using Nacelle Transfer Function (나셀 변환 함수를 이용한 풍력터빈 출력성능평가)

  • Kim, Hyeon-Wu;Ko, Kyung-Nam;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.51-58
    • /
    • 2013
  • A study on power performance testing of a wind turbine which has no met-mast at a distance of 2~4 rotor diameter was carried out using the Nacelle Transfer Function, NTF, according to IEC 61400-12-2. The wind data for this study was measured at HanKyoung wind farm of Jeju Island. The NTF was modeled using the correlation between wind speeds from the met-mast and from the wind turbine nacelle within 2~4 rotor diameter from the met-mast. The NTF was verified by the comparison of estimated Annual Energy Productions, AEPs, and binned power curves. The Nacelle Power Curve, NPC, was derived from the nacelle wind speed data corrected by NTF. The NPC of wind turbine under test and the power curve offered by the turbine manufacturer were compared to check whether the wind turbine is properly generating electricity. Overall the NPC was in good agreement with the manufacturer's power curve. The result showed power performance testing for a wind turbine which has no met-mast at a distance of 2~4 rotor diameter was successfully carried out in compliance with IEC 61400-12-2.

A study on Three Dimensional Configuration Scan by Photographing Parameters (스퍼기어의 3차원 모델링과 검증에 관한 연구)

  • 김세민;김민주;이승수;김순경;전언찬
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.369-374
    • /
    • 2001
  • Gear is general mechanical elements that used for power transmission between two shafts that interval is comparatively short. and it delivers big power as accurate ratio of speed. The profile of Spur gear which is the most basic factor is divided into Trochoidal fillet curve and Involute curve. Involute curve is used a lot of a shaped curve of machine parts such as a gear, a scroll compressor and a collar of centrifugal pump. However, it is poor to study the modeling of Trochoidal fillet curve and the three dimensions model shaped mathematical curve. This paper describes a mathematical model of profile shifted involute gear. and this model is based on Camus's theory. We draw three dimensions gear have accurate mathematical function using ADS, VisualLISP. and To check accuracy and perfection, we make a program of checking Interference. and use for this study.

  • PDF

A Study on the Three-dimensional Gear Modeling for CAD/CAM (CAD/CAM을 위한 3차원 기어 모델링에 관한 연구)

  • 주만식;김민주;이승수;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.1008-1012
    • /
    • 1997
  • This study is on a mathematical model of profile shifted involute gear, and this model is based on Camus's theory. Gear is general mechanical elements that used for power transmission between two shafts that interval is comparatively short. and it delivers bit power as accurate ratio of speed. The profile of Spur gear which is the most basic factor is divided into Trochoidal fillet curve and Involute curve. Involute curve is used a lot of a shape curve of machine parts such as a gear, a scroll compressor and a collar of centrifugal pump. However, It is poor to study the modeling of Trochoidal fillet curve and the three dimensions model shaped mathematical curve. So we draw three dimensions gear have accurate mathematical function using ADS(Automatic Drawing system), VisualLISP. To check accuracy and perfection, we make a program of checking Interference. and use for this study.

  • PDF

A Study on Cost Evaluation for Capacitive Reactive Power (무효전력 비용 산정에 관한 연구)

  • 정춘식;박정도;문영현
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.182-186
    • /
    • 2004
  • In this paper, the cost for capacitive reactive flower is evaluated considering the deregulation environment. For the cost assessment of reactive power, the duration curve of reactive power demand is introduced and investigated. Also, a guideline is suggested to estimate the Q-cost by using the inverse of the Q-demand duration curve. In order to obtain optimal real reactive power allocation, a new algorithm is proposed by using the piecewise linearization of the inverse of the Q-demand duration curve and the Linear Programming technique. The proposed method is tested with sample systems using MATLAB. The test results show that the algorithm yields reasonable reactive power allocation and Provides fair cost evaluation for reactive power.

A Novel Digital Over Current Relay with Variable Time-Current Characteristics for Protective Coordination

  • Park, M. S.;P. S. Cho;Lee, S. J.;S. H. Hyun;Kim, K. H.
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.3
    • /
    • pp.83-88
    • /
    • 2002
  • An over current relay(OCR), one of the most frequently used protective devices, has time-current characteristics (TCC) to control its trip time according to the current level. It is because an appropriate operating time interval is necessary for coordination with other protective devices. A set of TCC curves of an OCR is, in general, given by the supplier from which a curve is selected by the operator. Therefore, in many cases, it is impossible to consider the operation condition of the given power system exactly. A novel concept of an OCR is suggested in this paper. The proposed OCR has an internal correction module so that it may produce the most adequate TCC curve according to the given protective information for coordination with other devices. With the generated TCC curve, a variety of operation and coordination conditions can be taken into consideration in an effective manner. The suggested OCR is applied to a simple test power system to show very promising results from a coordination point of view.

Development of the ELDC Construction of Composite Power System (복합전력계통에서의 유효부하지속곡선 작성법의 개발)

  • Choi, Jae-Seok;Moon, Seung-Pil;Jo, Jong-Man;Kang, Jin-Jung
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.171-173
    • /
    • 1997
  • This study proposes a method for evaluating composite power system effective load duration curve(CMELDC) al load points. The concept of ELDC in power system planning is very useful and important in HLI as well as HLII. Effective load duration curve of composite power system can be obtained from convolution integral processing or both probability function of unarrival power and load duration curve at load points. The characteristics and effectiveness of this methodology arc illustrated by case studyings of simple system.

  • PDF

The Study about Performance Test of Wind turbine (풍력발전기 출력성능 평가에 대한 연구)

  • Ko, Suk-Whan;Jang, Moon-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1348-1349
    • /
    • 2011
  • In this paper, The case of power performance test for 3MW wind-turbine system is introduced. For the verification of power curve and the certification of wind-turbine, power performance test is very important. This paper described the power testing results of a 3MW wind turbine and analysed an uncertainty about the testing. The measured power curves are very closely coincide with the calculated. Total uncertainty of measured data for Power Curve is 120~200kW in the rated power.

  • PDF

The Effect of Viscosity of Natural Rubber on Incorporation Rate of Carbon Black in The Mixing (배합중 카본블랙 혼입속도에 천연고무 점도가 미치는 영향)

  • Kang, Yong-Gu;Han, Shin;Lee, Kye-Jung;Ryu, Dong-Wan;Park, Chan-Young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.1
    • /
    • pp.97-103
    • /
    • 1999
  • The power curve during rubber mixing presents useful information for the understanding of rubber mixing process, because the power curve is determined the mixing state of rubber at the point. The time to the second peak on the power curve is known as carbon black incorporation time, BIT. This study gets the quantity relationship of BIT and viscosity of natural rubber, so by determining the mixing time of the compound on the ground of viscosity of the raw rubber. The mixing with natural rubber and carbon black is examined for various grade natural rubbers, encompassing a wide range of Mooney viscosity. Alter smoothing the mixing power curve using a polynomial, the carbon black incorporation time, BIT, was determined time to second power peak on the curve, The BIT's versus specific values on Mooney viscometer test curve show a linear relation, Especially, the peak of initial maximum torque on Mooney viscometer curve, PMT, is most relevant property relating to the BIT. PMT is useful index for determined optimum mixing time, To apply this results at the mixing, we effectively control the natural rubber mixing but can also know the grading of natural rubber upon processability.

  • PDF

A Study on the Generator Capability Curve (발전기(發電機)의 가능출력곡선(可能出力曲線)에 관한 연구(硏究))

  • Park, Seong-Jin;Nam, Si-Bok
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.35-42
    • /
    • 1999
  • As our power system has changed the past undeveloped model causing the lacked supply of power to the civilized model that the remained one makes the voltage and the frequency rise at the middle of the night, the leading power factor operation of generators, that is, the under-exited operation is essentially to be needed, so, at a viewpoint of the stability of the power system, it is a very important factor. In this investigation. the equation of curves for each area on the capability curve has been studied at the above-mentioned viewpoint. Also, each capability curve for the operating power stations (Nuclear P/S, Thermal P/S, Hydrolic & pumping-up P/S Gas turbine P/S) has, been presented, and studied whether the leading power factor operational area is able to be expanded or not.

  • PDF