• Title/Summary/Keyword: power curve

Search Result 1,268, Processing Time 0.041 seconds

Bioequivalence of Two Clarithromycin Tablets (클래리스로마애신 정제의 생물학적 동등성 평가)

  • 김종국;이사원;최하곤;고종호;이미경;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.2
    • /
    • pp.219-224
    • /
    • 1998
  • The bioequivalence of two clarithromvcin products was evaluated with 16 normal male volunteers (age 23-28 yr, body weight 57.5-75.517g) following single oral dose. Test product was ReYon Clarithromycin tablets (ReYon Pharm. Corp., Korea) and reference product was Klarici $d_{R}$ tablets (Abbott Korea). Both products contain 250 mg of clarithromucin. One tablet of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of clarithromycin was accomplished using a modified agar well diffusion bioassay. As a result of the assay validation, the quantification of clarithromycin in human serum by this technique was possible down to 0.03$\mu$g/ml using 100$\mu$l of serum. The coefficient of variation (C.V.) was less than 10%. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products P>0.05); the area under the curve to last sampling time (24 hr) (AU $Co_{24hr}$ (8.10$\pm$ 1.26 vs 8.22$\pm$ 1.627g . hr/ml), AUC from time zero to infinite (AU $Co_{\infty}$) (8.61 $\pm$ 1.28 vs 8.84$\pm$ 1.71 $\mu$g . hr/ml), maximum plasma concentration ( $C_{msx}$) (0.87$\pm$0.22 vs 0.88$\pm$0.19 $\mu$g/ml) and time to maximum plasma concentration ( $T_{max}$) (2.69 $\pm$0.48 vs 2.56$\pm$ 0.51 hr). The differences of mean AU $Co_{24h}$, $C_{msx}$ and $T_{msx}$ between the two products (1.44, 1.39, and 4.65%, respectively) were less than 20%. The power (1-$\beta$) and treatment difference ($\Delta$) for AU $Co_{24hr}$, and $C_{max}$ were more than 0.8 and less than 0.2, respectivly. Although the power for $T_{max}$ was under 0.8, $T_{max}$. of the two products was not significantly different each other (p>0.05). These results suggest that the bioavailability of ReYon Clarithromycin tablets is not significantly different from that of Klarici $d_{R}$ tablets. Therefore, two products are bioequivalent based on the current results. results.sults.sults.s.s.s.s.s.s.s.

  • PDF

Modified Thermal-divergence Model for a High-power Laser Diode (고출력 레이저 다이오드 광원의 열저항 개선을 위한 하부층 두께 의존성 수정 모델)

  • Yong, Hyeon Joong;Baek, Young Jae;Yu, Dong Il;O, Beom Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.5
    • /
    • pp.193-196
    • /
    • 2019
  • The design and control of thermal flow is important for the operation of high-power laser diodes (LDs). It is necessary to analyze and improve the thermal bottleneck near the active layer of an LD. As the error in prediction of the thermal resistance of an LD is large, typically due to the hyperbolic increase and saturation to linear increase of the thermal resistance as a function of thickness, it is helpful to use a simple, modified divergence model for the improvement and optimization of thermal resistance. The characteristics of LDs are described quite well, in that the values for simulated thermal resistance curves and the thermal cross section followed are almost the same as the values from the model function. Also, the thermal-cross-section curve obtained by differentiating the thermal resistance is good for identifying thermal bottlenecks intuitively, and is also fitted quite well by the model proposed for both a typical LD structure and an improved LD with thin capping and high thermal conductivity.

Electrical Characteristics of PV Modules with Odd Strings by Arrangement on Bypass Diode (홀수스트링 PV모듈의 바이패스 다이오드 배치에 의한 전기적 특성)

  • Shin, Woo-Gyun;Go, Seok-Hwan;Ju, Young-Chul;Song, Hyung-Jun;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.4
    • /
    • pp.1-11
    • /
    • 2017
  • Most PV modules are fabricated by 6 cell-strings with solar cells connected in series. Moreover, bypass diodes are generally installed every 2 cell-strings to prevent PV modules from a damage induced by current mismatch or partial shading. But, in the case of special purpose PV module, like as BIPV (Building Integrated Photovoltaic), the number of cell-strings per module varies according to its size. Differ from a module employing even cell-strings, the configuration of bypass diode should be optimized in the PV module with odd strings because of oppositely facing electrodes. Hence, in this study, electrical characteristics of special purposed PV module with odd string was empirically and theoretically studied depending on arrangement of bypass diode. Here, we assumed that PV module has 3 strings and the number of bypass diodes in the system varies from 2 to 6. In case of 2 bypass diodes, shading on a center string increases short circuit current of the module, because of a parallel circuit induced by 2 bypass diodes connected to center string. Also, the loss is larger, as the shading area in the center string is enlarged. Thus, maximum power of the PV module with 2 bypass diode decreases by up to 59 (%) when shading area varies from 50 to 90 (%). On the other hand, In case of 3 and 6 bypass diodes, the maximum power reduction was within about 3 (W), even the shading area changes from 50 to 90 (%). As a result, It is an alternative to arrange the bypass diode by each string or one bypass diode in the PV module in order to completely bypass current in case of shading, when PV module with odd string are fabricated.

Design of Thermo-optic Switch with Low Power Consumption by Electrode Optimization (전극 구조의 최적화를 통한 저전력 열광학 스위치 설계)

  • Choi, Chul-Hyun;Kong, Chang-Kyeng;Lee, Min-Woo;Sung, Jun-Ho;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.266-271
    • /
    • 2009
  • We designed a thermo-optic switch based on a directional coupler with not only a high extinction ratio but also significantly low power consumption. The switch operates by using the thermo-optic effect of the polymer which the refractive index changes by heating the electrode. If the electrode is not powered (OFF), the input light will be coupled completely to the other waveguide. When the electrode is powered at a certain level (ON), input light launched into the input waveguide will remain in that waveguide due to the lower index adjusted in the other waveguide. The switch based on the directional coupler was designed using the generalized extinction ratio curve and the lateral shift of the input waveguide. The coupling length is 1,610 ${\mu}m$ and the extinction ratios are -28 and -30 dB for ON and OFF states, respectively. The electrode structures were optimized by thermal analysis. The transported heat into the waveguide is increased, as the electrode width (w) is increased and the center distance between the electrode and the waveguide (d) is decreased. Also, because the heat generated in the electrode affects the other waveguide, the temperature difference between two waveguides is varied as the given w and d. There are specific conditions which have the maximum of the temperature difference. That of the temperature difference is increased as the width and the temperature of the electrode are increased. Especially, when the switch is designed using the condition with the maximum of the temperature difference for switching, the temperature of the electrode can be decreased. We expect this condition will be the novel method for the reduction of the power consumption in a thermo-optic switch.

A Study on the Handles of Clay Cups by Studio Potters (도자기 컵 손잡이에 관한 연구 - 도예공방 생산 수제 컵 손잡이 중심으로 -)

  • Lee, Chi-Youn
    • Archives of design research
    • /
    • v.19 no.1 s.63
    • /
    • pp.293-302
    • /
    • 2006
  • clay cups with handles made in studios in Korea and the United States were selected and analyzed. The shape of cup were fixed to ensure proper comparison between handle size of the cup and position. The variable factors were the thickness of the handle, the number of fingers required to hold the cup, the relationship between the handle's shape and the position of its attachment to the cup, the effect of the handle's setter, the change in shape of the handle's thickness, and the relationship between the cup's weight center and handle. Preference test were designed and tested to the users, and the results were analyzed. The results showed that to make a comfortable handle, it is important to incorporate the shape of the resting hand in the design of the handle. Specifically, the design should be such that the cup can be held comfortably. This is possible if the weight of the cup is spread evenly when several fingers are inside the handle's curve and if such factors as the hand size, the curve of the fingers, and the position that best controls the cup's weight center are carefully considered. At this time, if there is a setter for the thumb, a cup of the same weight can be lifted more lightly. In the design of such a cup, the oval line is drawn by extending the cup's handle toward the direction of the cup's body. If the cup's weight center is located on the oval line, the cup's handle may be said to be effective. In such a case, the nearer the handle is to the cup's body weight center, the less power is needed to lift the cup efficiently. Our test results can be applied as a powerful tools in design and manufacturing cups with handle in terms of artistry and functionality.

  • PDF

The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate (표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향)

  • Oh, Joo Young;Kim, Jung Yul;Oh, Ki Baek;Oh, Shin Hyun;Kim, Jae Sam;Lee, Chang Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • Objectives: It is certain that Radioactive iodine thyroid uptake(RAIU) rate should be measured with the standard counts considering the thyroid gland depth in enlarged thyroid patients for the variation from geometric factors. The purpose of this paper is to consider the effects of geometric factors according to detector to source distance and the effective thyroid depth on RAIU rate with experiment test. Materials and Methods: I-131 370 kBq ($10{\mu}Ci$) point source was measured by Captus-3000 thyroid uptake system (Capintec, NJ, USA) with a change Detector-Source Distance from 20 cm to 30 cm at an interval of 1 cm. And we changed the Neck phantom surface-Source Depth in the phantom with 1 cm, 2 cm, 5 cm using the neck phantom in order to reproduce the effective thyroid depth. Results: Every experimental group follows power curve as inverse square curve ($$R2{\geq_-}0.915$$). The average count rates in the case not using a phantom and the every case applied the effective thyroid depth using a phantom was not identical each other. There was significant fluctuations upon the effective thyroid depths applied the effective thyroid depth above 1 cm in $364.4 keV{\pm}10%$ energy ROI (p<0.01). There was not significant difference between the count rates of 1 cm and 2 cm in $364.4keV{\pm}20%$ and $637.1keV{\pm}6.2%$ (p=0.354, p=0.397). In assumed RAIU rate from regression equation, $364.4keV{\pm}20%$ was lower difference than $364.4keV{\pm}10%$ as 6.42% and 5.09% per 1 cm. Every change of count rate upon depth appears decreased line on Linear Regression, but the case of $284.3keV{\pm}10%$ increased only. And also, The graphs of coefficient of variation upon depth increased as straight line on every experimental group. Conclusion: The result appears that application of $364.4keV{\pm}20%$ energy ROI is more suitable for reducing error from the effective thyroid depth. And also, we can estimate the error of 20 cm should be highly reduced than 30 cm for Inverse Square Law. Therefore, If there is not information of the thyroid depth, it is considered that the error from thyroid depth can reduce through set up energy ROIs for $364.4keV{\pm}20%$, and increase Detector-Source Distances.

  • PDF

Plasma-Assisted Molecular Beam Epitaxy of InXGa1-XN Films on C-plane Sapphire Substrates (플라즈마분자선에피탁시법을 이용한 C-면 사파이어 기판 위질화인듐갈륨박막의 에피탁시 성장)

  • Shin, Eun-Jung;Lim, Dong-Seok;Lim, Se-Hwan;Han, Seok-Kyu;Lee, Hyo-Sung;Hong, Soon-Ku;Joeng, Myoung-Ho;Lee, Jeong-Yong;Yao, Takafumi
    • Korean Journal of Materials Research
    • /
    • v.22 no.4
    • /
    • pp.185-189
    • /
    • 2012
  • We report plasma-assisted molecular beam epitaxy of $In_XGa_{1-X}N$ films on c-plane sapphire substrates. Prior to the growth of $In_XGa_{1-X}N$ films, GaN film was grown on the nitride c-plane sapphire substrate by two-dimensional (2D) growth mode. For the growth of GaN, Ga flux of $3.7{\times}10^{-8}$ torr as a beam equivalent pressure (BEP) and a plasma power of 150 W with a nitrogen flow rate of 0.76 sccm were fixed. The growth of 2D GaN growth was confirmed by $in-situ$ reflection high-energy electron diffraction (RHEED) by observing a streaky RHEED pattern with a strong specular spot. InN films showed lower growth rates even with the same growth conditions (same growth temperature, same plasma condition, and same BEP value of III element) than those of GaN films. It was observed that the growth rate of GaN is 1.7 times higher than that of InN, which is probably caused by the higher vapor pressure of In. For the growth of $In_xGa_{1-x}N$ films with different In compositions, total III-element flux (Ga plus In BEPs) was set to $3.7{\times}10^{-8}$ torr, which was the BEP value for the 2D growth of GaN. The In compositions of the $In_xGa_{1-x}N$ films were determined to be 28, 41, 45, and 53% based on the peak position of (0002) reflection in x-ray ${\theta}-2{\theta}$ measurements. The growth of $In_xGa_{1-x}N$ films did not show a streaky RHEED pattern but showed spotty patterns with weak streaky lines. This means that the net sticking coefficients of In and Ga, considered based on the growth rates of GaN and InN, are not the only factor governing the growth mode; another factor such as migration velocity should be considered. The sample with an In composition of 41% showed the lowest full width at half maximum value of 0.20 degree from the x-ray (0002) omega rocking curve measurements and the lowest root mean square roughness value of 0.71 nm.

Narrative Strategies for Learning Enhanced Interface Design "Symbol Mall"

  • Uttaranakorn, Jirayu;McGregor, Donna-Lynne;Petty, Sheila
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.417-420
    • /
    • 2002
  • Recent works in the area of multimedia studies focus on a wide range of issues from the impact of multimedia on culture to its impact on economics and anything in between. The interconnectedness of the issues raised by this new practice is complicated by the fact that media are rapidly converging: in a very real way, multimedia is becoming a media prism that reflects the way in which media continually influence each other across disciplines and cultural borders. Thus, the impact of multimedia reflects a complicated crossroads where media, human experience, culture and technology converge. An effective design is generally based on shaping aesthetics for function and utility, with an emphasis on ease of use. However, in designing for cyberspace, it is possible to create narratives that challenge the interactor by encoding in the design an instructional aspect that teaches new approaches and forms. Such a design offers an equally aesthetic experience for the interactor as they explore the meaning of the work. This design approach has been used constructively in many applications. The crucial concern is to determine how little or how much information must be presented for the interactor to achieve a suitable level of cognition. This is always a balancing act: too much difficulty will result in interactor frustration and the abandonment of the activity and too little will result in boredom leading to the same negative result In addition, it can be anticipated that the interactor will bring her or his own level of experiential cognition and/or accretion, to the experience providing reflective cognition and/or restructure the learning curve. If the design of the application is outside their present experience, interactors will begin with established knowledge in order to explore the new work. Thus, it may be argued that the interactor explores, learns and cognates simultaneously based on primary experiential cognition. Learning is one of the most important keys to establishing a comfort level in a new media work. Once interactors have learned a new convention, they apply this cognitive knowledge to other new media experiences they may have. Pierre Levy would describe this process as a "new nomadism" that creates "an invisible space of understanding, knowledge, and intellectual power, within which new qualities of being and new ways of fashioning a society will flourish and mutate" (Levy xxv 1997). Thus, navigation itself of offers the interactors the opportunity to both apply and loam new cognitive skills. This suggests that new media narrative strategies are still in the process of developing unique conventions and, as a result, have not reached a level of coherent grammar. This paper intends to explore the cognitive aspects of new media design and in particular, will explore issues related to the design of new media interfaces. The paper will focus on the creation of narrative strategies that engage interactors through loaming curves thus enhancing interactivity.vity.

  • PDF

Some Statistical Considerations for the Estimation of Urinary Mercury Excretion in Normal Individuals (정상인의 요중 수은배설량 추정의 통계학적 연구)

  • Park, Hee-Sook;Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.13 no.1
    • /
    • pp.27-34
    • /
    • 1980
  • Purpose of this study is to find out proper means of estimating the urinary mercury excretion in the normal individuals. Whole void volume was collected every 2 hours beginning from 6 o'clock in the morning until 6 o'clock next morning. Mercury excretion in each urine specimen was measured by NIOSH recommended dithizone colorimetric method (Method No.: P & CAM 145). Urinary concentration of mercury was adjusted by two means: specific gravity of 1.024 and a gram of creatinine excretion per liter of urine comparing the data with the unadjusted ones. Mercury excretion in 24-hour urine specimen was calculated by adding the amounts measured with the hourly collected specimens of each individual. Statistical analysis of the urinary mercury excretion revealed the following results: 1. Frequency distribution curve of mercury excreted in urine of hourly specimens was best fitted to power function expressed in the form of $y=ax^b$. Adjustment of the urinary mercury concentration by creatinine excretion was shown to be superior($y=1674x^{-1.52},\;r^2=0.95$) over nonadjustment($y=2702x^{-1.57},\;r^2=0.92$) and adjustment by specific gravity of 1.024($y=4535x^{-1.66},\;r^2=0.93$). 2. Both log-transformed mercury excretion in hourly voided specimens and mercury excretion itself in 24 hour specimens showed the normal distributions. 3. The frequency distribution of mercury adjusting the urinary concentration of mercury by creatinine excretion was best fitted to a theoretical normal distribution with the sample means and standard deviation than those unadjusted or adjusted with specific gravity of 1.024. 4. Average urinary mercury excretions in 24-hour urine specimen in an individual were as follows: a) Unadjusted mercury excretion mean and standard deviation : $$18.6{\pm}13.68{\mu}gHg/l$$. median : $$16.0\;{\mu}gHg/l$$. range : $$0.0-55.10\;{\mu}gHg/l$$. b) Adjusted with specific gravity mean : $$20.7{\pm}11.76\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ median : $$20.7\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ range : $$0.0-52.9\;{\mu}gHg/l{\times}\frac{0.024}{S.G-1.000}$$ c) Adjusted with creatinine excretion mean and standard deviation : $$10.5{\pm}6.98\;{\mu}gHg/g$$ creatinine/l median : $$9.4\;{\mu}gHg/g$$ creatinine/l range : $$0.0-26.7\;{\mu}gHg/g$$ creatinine/l 5. No statistically significant differences were found between means calculated from 24-hour urine specimens and those from hourly specimens transformed into logarithmic values. (P<0.05).

  • PDF

An Application of Remote Sensing Method for Close-to-nature Stream Evaluation : Focusing on Vegetation Index of Multi-Spectral Satellite Image (자연형 하천평가를 위한 원격탐사법 응용 : 다중파장 위성영상의 식생지수 중심)

  • Yoon, Yeong-Bae;Cho, Hong-Je;Kim, Geun-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.462-466
    • /
    • 2006
  • Close-to-nature stream evaluation is one of the processing to make the streams over in order to keep them natural. It is integral to evaluate and make an accurate analysis of them on the purpose of maintaining streams healthy. For many instances, there are, stream organization evaluation for restoration by German government, evaluation for ecosystem protection in natural preserves by New Zealand government, and stream-view evaluation for restoration by Britain government so on. In case of the country there are analysis and evaluation of stream physical organization by Cho, Yong-hyun, Close-to-nature stream evaluation for restoration by Kim, Dong-chan, evaluation of stream properties in korea by Park, Bong-jin. Close-to-nature evaluation by Lim, Chan-uk, that is advanced version of Park, Bong-jin's, shows form of stream including waterway curve, sand bar, diversity of flow, river bed material, diversity of minor bed, minor bed bank protection works, bank protection material. It also does environment of stream including side of minor bed vegetation, width of surface of the water/width of the river etc.. By the way, this evaluation does not have free access to apply those details above in the field, it often happens that you get various outcome from the one spot. so you must need more realistic testing method to obtain more accurate data. Remote sensing method is highly recommended because this is very useful for collecting realistic data of vegetation index. what is more, it can not only scan even the minimum area within its resolving power but also do obtain data anytime. Vegetation index indicates Ratio vegetation index, Normalized difference vegetation index, Soil adjusted vegetation index, Atmospherically resistant vegetation index etc.. The research is focusing on Cheokgwa stream which is the branch of Taehwa river and shows 19 sectioned Close-to-nature stream performed according to the method by Lim, chan-uk. Besides let you know vegetation index came from image data of satellite landsat 7 with the variation of buffering area, of the day 9. may. 2003. Of all, the outcome 0.758 at 200m buffer-zone of NDVI was the best we have got so far.

  • PDF