• Title/Summary/Keyword: power controllability

Search Result 117, Processing Time 0.028 seconds

A Study on Estimation Method of Outage Cost caused by Vulnerabilities of SCADA System (SCADA 시스템의 보안취약성을 고려한 정전비용 산정기법에 관한 연구)

  • Kim, Balho-H.;Kang, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.90-99
    • /
    • 2011
  • As power industry evolves into Smart Grid scheme, previously closed power systems are being integrated into public communication networks. It increases the controllability and efficiency of the system, but also accompanies many cyber threats having existed in the Internet to the SCADA system. Therefore it is required to apply security countermeasures to the Smart Grid, which brings about investment costs. There have been few approaches to assess risks from cyber attack especially in electric power industry. So this paper proposes a methodology to assess quantitative impacts of various types of cyber attacks to a power system, and also shows the feasibility of the method through a case study.

the power flow control and voltage compensation by 20kVA prototype UPFC (20kVA급 Prototype UPFC의 전력조류제어와 모선전압보상)

  • Jeon, Jin-Hong;Kim, Ji-Won;Chun, Yeung-Han;Kim, Hak-Man;Kook, Kyung-Soo;Oh, Tae-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.349-352
    • /
    • 2001
  • FACTS technology is developed into the sophisticated system technology which combines conventional power system technology with power electronics, micro-process control, and information technology. Its objectives are achieving enhancement of the power system flexibility and maximum utilization of the power transfer capability through improvements of the system reliability, controllability, and efficiency [1]. As a series and shunt compensator, UPFC consists of two inverters with common dc link capacitor bank. It controls the magnitude of shunt bus voltage and real and reactive power flow of transmission line[2]. In this paper, we present the design, implementation and test results of developed 20kVA level prototype UPFC. It is applied to power system simulator and controls the real and reactive power flow and shunt bus voltage magnitude.

  • PDF

A Shared Channel Design for the Power and Signal Transfers of Electric-field Coupled Power Transfer Systems

  • Su, Yu-Gang;Zhou, Wei;Hu, Aiguo Patrick;Tang, Chun-Sen;Hua, Rong
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.805-814
    • /
    • 2016
  • Electric-field coupled power transfer (ECPT) systems have been proposed as an alternative wireless power transfer (WPT) technology in recent years. With the use of capacitive plates as a coupling structure, ECPT systems have many advantages such as design flexibility, reduced volume of the coupling structure and metal penetration ability. In addition, wireless communications are effective solutions to improve the safety and controllability of ECPT systems. This paper proposes a power and signal shared channel for electric-field coupled power transfer systems. The shared channel includes two similar electrical circuits with a band pass filter and a signal detection resistor in each. This is designed based on the traditional current-fed push-pull topology. An analysis of the mutual interference between the power and signal transmission, the channel power and signal attenuations, and the dynamic characteristic of the signal channel are conducted to determine the values for the electrical components of the proposed shared channel. Experimental results show that the designed channel can transfer over 100W of output power and data with a data rate from 300bps to 120 kbps.

Application of Fuzzy PI Control Algorithm as Stator Power Controller of a Double-Fed Induction Machine in Wind Power Generation Systems

  • Chung, Gyo-Bum;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.109-116
    • /
    • 2009
  • This paper addresses the output control of a utility-connected double-fed induction machine (DFIM) for wind power generation systems (WPGS). DFIM has a back-to-back converter to control outputs of DFIM driven by the wind turbine for WPGS. To supply commercially the power of WPGS to the grid without any problems related to power quality, the real and reactive powers (PQ) at the stator side of DFIM are strictly controlled at the required level, which in this paper is realized with the Fuzzy PI controller based on the field orientation control. For the Sinusoidal Pulse Width Modulation (SPWM) converter connected to the rotor side of DFIG to maintain the controllability of PQ at the state side of DFIM, the DC voltage of the DC link capacitor is also controlled at a certain level with the conventional Proportion-Integral (PI) controller of the real power. In addition, the power quality at the grid connected to the rotor side of DFIM through the back-to-back converter is maintained in a certain level with a PI controller of the reactive power. The controllers for the PQ at the stator side of DFIM, the DC link voltage of the back-to-back inverter and the reactive power at the grid connected to the rotor side of DFIM are designed and simulated in the PSIM program, of which the result verifies the performance of the proposed controllers.

Control of Power Quality Using a High Voltage STATCOM for the Integration of Large Scale Wind Power Plant (고전압 무효전력 보상기를 사용한 대규모 풍력발전 설비의 전력 품질 보상)

  • Kim, Jihong;Song, Seungho;Jeong, Seunggi
    • New & Renewable Energy
    • /
    • v.8 no.4
    • /
    • pp.13-20
    • /
    • 2012
  • This paper describes a transformerless static synchronous campensator (STATCOM) system based on cascade H-bridge multilevel inverter with star configuration. It is designed not only for the dynamic and continuous compensation of the reactive power but also for the improvement of power quality of existing wind power plant. Especially, when the induction generator of wind turbine is directly connected to the grid, reactive power are occurred by exiting current. so a reactive power compensation system based on the cascade H-bridge multilevel STATCOM is proposed because the output power quality and controllability of reactive power are required by grid code in many different countries. Using various The proposed reactive power control strategy using a STATCOM is compared with the conventional scheme using fixed-size of capacitor bank through various simulation results.

State Observer Design Considering Modelling Errors and Parameter Variations (모델링 오차와 파라미터변동을 고려한 상태 관측기 설계)

  • Kim, Chan-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2078-2081
    • /
    • 1997
  • IP speed controller is used as a main controller and it makes the system low overshoot and easy controllability. Load torque is estimated by Kalman filter algorithm and parameter controller is used against a rotor inertia negative variations. Parameter Controller (PC) is equipped with a torque observer implemented by software of a digital signal Processor. PC is a parameter controller which selects a moment of inertia J in responding to a load torque to control the system response.

  • PDF

Development of thyristor motor and controller (사이리스터 모타 및 제어반의 국산화개발)

  • 김은곤;한세희;김호겸
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.387-392
    • /
    • 1986
  • DC motor is excellent in controllability and efficiency, but vulnerable in maintenance with respect to AC motor owing to the development of power devices and microelectronics, excellent AC motor drives which have characteristics as similar as DC motor's have been developed. Thyristor motor equipment that has an important role with Inverter in the field of AC motor drives was developed in the late 1960. There was no research about thyristor motor in Korea, then thyristor motor equipment was all imported. By this we started to develop in 1983, was tested in 1984, 1985. Now we express ourselves about thyristor motor equipment development procedure and characteristics.

  • PDF

A Study on the Four Quadrant Operation of SRM Drive (SRM의 4상한 구동을 위한 제어방식)

  • Kang Yu-Jung;Park Sung-Jun;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.45-48
    • /
    • 2002
  • Switched Reluctance Generator attracts much attention because of high efficiency, simple controllability with traction drive. But the theories that have been adopted as SRG control methods are complicated up to the present. This paper proposes reference current limitation strategy for stable generation and switching angle control in motoring mode. The proposed method is verified by simulation and experiments.

  • PDF

A novel hybrid LLC converter topology of on-board battery chargers for electric vehicles (전기자동차 온보드 충전기를 위한 새로운 하이브리드 LLC 공진 컨버터)

  • Ta, Le Anh Dao;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.197-198
    • /
    • 2018
  • This paper proposes a novel hybrid converter topology suitable for electric vehicle on-board battery chargers, which is a combination of the full-bridge (FB) and half-bridge (HB) LLC circuits. A full load controllability under wide output voltage range can be achieved with a small resonant inductance, which increases the efficiency and lowers the size and cost. Simulation results are shown to evaluate the dynamic performance of the proposed converter.

  • PDF