• Title/Summary/Keyword: power change

Search Result 5,095, Processing Time 0.039 seconds

Study on the Institutional Change of Early Childhood Education Quality Assurance in China: From the Perspective of Historical Institutionalism (중국 유아교육의 질 보장제도 변천에 관한 연구: 역사적 제도주의 관점에서의 분석)

  • Wang, Jing;Lee, Seung-Mie
    • Human Ecology Research
    • /
    • v.58 no.1
    • /
    • pp.87-103
    • /
    • 2020
  • This study discusses the institutional change of Chinese early childhood education quality assurance institution (ECEQAI) from the three dimensions of the perspective of historical institutionalism of that refer to the external environment, dynamic mechanism containing with nation-market-society, and the invisible ideology of the institutional change. Chinese ECEQAI was divided into five historical periods, which were 17 years after the founding of China (1949-1966), the Great Cultural Revolution (GCR) period (1966-1976), the early stage of Reform and Opening-up (RO) (1976-1995), the social change period (1995-2010) and the new period (2010-now). This study also concludes five separate change models for Chinese ECEQAI that correspond to the five periods. The first was a compulsory and gradual institutional change model influenced by the Soviet model and dominated by national power. The second was compulsory and radical change model controlled by the counter-revolutionary group. The third was a compulsory and gradual institutional change model dominated by national power. The fourth was induced and gradual institutional change model driven by market power and forced by society power. The fifth was a compulsory and gradual institutional change model led by national power and forced by society power. Finally, the future change direction of China's ECEQAI was further pointed out, that was the government-leading and tend to balanced three-pole power model of "Nation-Market-Society", as well as the "three-pole power relationship" of indepth communication and positive interaction.

Numerical Simulation of Environmental Change in South West Offshore Wind Farm Using MIKE

  • Kim, Minsuek;Kim, Jiyoung;Jeon, In-sung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.145-152
    • /
    • 2021
  • Environmental change due to construction of large offshore wind farm has been a debate for a long time in Korea. There are various data acquired on hydrodynamics around this area before and during construction of offshore wind farm but no data during operation could be made due to delayed schedule. In this study, environmental change such as bathymetry change and scouring was forecasted using MIKE, numerical hydrodynamics model, and its results were validated using the observation data before and during construction.

A New Control Method for an Adaptive Noise Canceller Using Stochastic difference between Voice and Noise Signals Power Change

  • Nishi, H.;Kakinoki, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2362-2367
    • /
    • 2005
  • This paper reports a technique for discriminating double talk and echo path change using the stochastic characteristics of power change for an adaptive noise canceller. The causes of rapid error increasing are double talk and echo path change. When the echo path is changed, the system corrects the impulse response in order to reduce the error. However, in the case of double talk, the system has to suspend the updating impulse response in order to maintain the quality of the voice signal. In the conventional system, it was difficult to discriminate between the two situations. In this research, the stochastic characteristics of the voice power change in the double talk period were experimentally verified to be different from the power change during echo path changing. Based on the results, a new double talk detection method is proposed.

  • PDF

Active and Reactive Power Compensator for Wind Power System with Squirrel-Cage Induction Generator (농형유도 풍력발전시스템을 위한 유.무효전력보상장치)

  • Yang, Seung-Chul;Ju, Young-Ah;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.48-50
    • /
    • 2008
  • A wind power system with squirrel-cage induction generator has irregular change of output power according to the sudden change of wind speed. This paper describes the development of a active and reactive power compensator, which is composed of a 3-phase inverter and a bidirectional DC/DC converter with super-capacitor. The operational characteristic was analyzed through simulations with PSCAD/EMTDC and experimental works with a scaled model. The developed system can continuously compensate the active power change with energy storage and the reactive power change with 3-phase inverter.

  • PDF

Low Power Flip-Flop Circuit with a Minimization of Internal Node Transition (인터널 노드 변환을 최소화시킨 저전력 플립플롭 회로)

  • Hyung-gyu Choi;Su-yeon Yun;Soo-youn Kim;Min-kyu Song
    • Transactions on Semiconductor Engineering
    • /
    • v.1 no.1
    • /
    • pp.14-22
    • /
    • 2023
  • This paper presents a low-power flip-flop(FF) circuit that minimizes the transition of internal nodes by using a dual change-sensing method. The proposed dual change-sensing FF(DCSFF) shows the lowest dynamic power consumption among conventional FFs, when there is no input data transition. From the measured results with 65nm CMOS process, the power consumption has been reduced by 98% and 32%, when the data activity is 0% and 100%, respectively, compared to conventional transmission gate FF(TGFF). Further, compared to change-sensing FF(CSFF), the power consumption of proposed DCSFF is smaller by 30%.

Autonomous Adaptive Digital Over Current Relay (계통변화를 고려한 자율 적응형 과전류 계전기)

  • J.S., Jun-Seok;Lee, S.J.;Choi, M.S.;Kang, S.H.;Kim, S.T.;Lim, S.I.;Oh, S.M.;Kim, J.K.;Park, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.6-8
    • /
    • 2002
  • In this paper present Autonomous Adaptive Digital Over Current Relay which acts autonomous setting using voltage and current measured by relay in the change of power systems. Automation of relay setting is required for distribution automation although manual relay setting is used at present. This paper presents Autonomous Relay Setting which knows change of the power system and acquires setting element using the Recursive Least Squares. Relay setting is very difficult work. But proposed relay is expected to decrease burden of relay setting using acquired information of power system change and autonomous setting. Also fast protective ability is expected according to change of power system.

  • PDF

Analysis of Operating Characteristics in Tidal Power Generation According to Tide Level

  • Hong, Jeong-Jo;Oh, Young-sun
    • International Journal of Contents
    • /
    • v.18 no.1
    • /
    • pp.76-84
    • /
    • 2022
  • Tidal power generation plays a critical role in reducing greenhouse gas emissions. It uses a tidal force generated by gravitational force between the moon, the earth, and the sun. The change of seawater height generates the tide-generating force, and the magnitude of the change is the tide level. The tide level change has the same period as the tide-generating force twice a day, every 29.5 days, every year, and every 18.6 years. Sihwa Lake Tidal Power Station is Korea's first tidal power plant that began commercial power generation in August 2011 and has been accumulating a large volume of data on electricity production, power generation sales, sluice displacement, and tide levels. The purpose of this paper was to analyze the impact of the inefficiency factors affecting production and the tidal level change on tidal power generation and their characteristics using Sihwa Lake Tidal Power's operational performance data. Throughout this paper we show that tidal power generating operation is accurately predicting the trends of magnitude of tidal force to be periodical for each day. determining the drop to initiate the water turbine generator factoring the constraints on the operation of Sihwa Lake, and reflecting the water discharge through the floodgate and water turbine during the standby mode in the power generation plan to be in the optimal condition until the initiation of the next power generation can maximize power generation.

The Pahlev Reliability Index: A measurement for the resilience of power generation technologies versus climate change

  • Norouzi, Nima
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1658-1663
    • /
    • 2021
  • Research on climate change and global warming on the power generation systems are rapidly increasing because of the Importance of the sustainable energy supply, thus the electricity supply since its growing share, in the end, uses energy supply. However, some researchers conducted this field, but many research gaps are not mentioned and filled in this field's literature since the lack of general statements and the quantitative models and formulation of the issue. In this research, an exergy-based model is implemented to model a set of six power generation technologies (combined cycle, gas turbine, nuclear plant, solar PV, and wind turbine) and use this model to simulate each technology's responses to climate change impacts. Finally, using these responses to define and calculate a formulation for the relationship between the system's energy performance in different environmental situations and a dimensionless index to quantize each power technology's reliability against the climate change impacts called the Pahlev reliability index (P-index) of the power technology. The results have shown that solar and nuclear technologies are the most, and wind turbines are the least reliable power generation technologies.

DC-Link Voltage Unbalance Compensation of Reactive Power Compensator using Multi-level Inverter (멀티레벨 인버터를 이용한 무효전력 보상장치에서의 DC-Link 전압 불평형 보상)

  • Kim, Hyo-Jin;Jung, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.422-428
    • /
    • 2013
  • Recently, we use a static synchronous compensator(STATCOM) with cascaded H-bride topologies, because it is easy to increase capacity and to reduce total harmonic distortion(THD). When we use equipment for reactive power compensation, dc-link voltage unbalances occur from several reasons although loads are balanced. In the past, switching pattern change of single phase inverter and reference voltage magnitude change of inverter equipped with power sensor have been used for dc-link voltage balance. But previous methods are more complicated and expensive because of additional component costs. Therefore, this paper explains reasons of dc-link voltage unbalance and proposes solution. This solution is complex method that is composed of reference voltage magnitude change of inverter without additional hardware and shifted phase angle of inverter reference voltages change. It proves possibility through 1000[KVA] system simulation.

Boiler Performance Characteristics Change by UC Contents Increase for Coal Fired Power Plant (석탄연소 화력발전소에서 미연탄소분 농도 증가가 보일러 성능에 미치는 영향에 관한 연구)

  • Kim, Taehyung;Park, Byungchul
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.99-102
    • /
    • 2015
  • To operate coal fired power plant efficiently is considered unburned carbon as important factor. But, unburned carbon contents change does not have an impact on Boiler performance simultaneously. we evaluated that unburned carbon contents change had an little influence on unburned carbon loss change for performance side at a real power plant.

  • PDF