• Title/Summary/Keyword: power cable tunnel

Search Result 61, Processing Time 0.043 seconds

Conservativeness Evaluation of Response Acceleration Method used in Seismic Response Analysis of Power Cable Tunnel (전력구의 지진응답해석에 사용되는 응답진도법의 보수성 평가)

  • Lim, Jae-Sung;Kim, Gi-Bae;Chun, Nak-Hyun;Kim, Jae-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.309-317
    • /
    • 2021
  • In this paper, we present the evaluation results for the conservatism of the response acceleration method (RAM), for seismic response analysis of box-type power cable tunnels. We studied 50 examples, considering the cross sections of 25 power cable tunnels, and two soil conditions for each power cable tunnel. A refined dynamic analysis method considering the soil-structure interaction was further employed to evaluate the conservatism of the RAM. The comparison revelated that the seismic responses computed using the RAM were consistent with those obtained using the refined method, since the averages of response ratio (defined as the ratio of the response by RAM to that of the refined method) approached 1.0, and the standard deviations of the response ratio were less than 5%. Finally, we found that applying a load factor of 1.1 to the response of the RAM allowed for a conservative design for seismic loads.

Surveillance System For Underground Power Transmission Lines (초고압 지중선로 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.618-620
    • /
    • 1993
  • This system using optical fiber provides various information about underground tunnel and power transmission lines-atmospheric temperature, humidity, oil pressure, flammable gas, cable behavior, and so on. To transmit various data and to keep reliability, optical MUXs are adopted. User can easily operate monitoring software by using GUI.

  • PDF

Sheath Circulating Current Analysis of a Crossbonded Power Cable Systems

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.320-328
    • /
    • 2007
  • The sheath in underground power cables serves as a layer to prevent moisture ingress into the insulation layer and provide a path for earth return current. Nowadays, owing to the maturity of manufacturing technologies, there are normally no problems for the quality of the sheath itself. However, after the cable is laid in the cable tunnel and is operating as part of the transmission network, due to network construction and some unexpected factors, some problems may be caused to the sheath. One of them is the high sheath circulating current. In a power cable system, the uniform configuration of the cables between sections is sometimes difficult to achieve because of the geometrical limitation. This will cause the increase of sheath circulating current, which results in the increase of sheath loss and the decrease of permissible current. This paper will study the various characteristics and effects of sheath circulating current, and then will prove why the sheath current rises on the underground power cable system. A newly designed device known as the Power Cable Current Analyser, as well as ATP simulation and calculation equation are used for this analysis.

The study on the effect of fracture zone and its orientation on the behavior of shield TBM cable tunnel (단층파쇄대 규모 및 조우 조건에 따른 전력구 쉴드 TBM 터널의 거동 특성 분석)

  • Cho, Won-Sub;Song, Ki-Il;Kim, Kyoung-Yul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.4
    • /
    • pp.403-415
    • /
    • 2014
  • Recently, the temperature rise in the summer due to climate change, power usage is increasing rapidly. As a result, power generation facilities have been newly completed and the need for ultra-high-voltage transmission line for power transmission of electricity to the urban area has increased. The mechanized tunnelling method using a shield TBM have an advantage that it can minimize vibrations transmitted to the ground and ground subsidence as compared with the conventional tunnelling method. Despite the popularity of shield TBM for cable tunnel construction, study on the mechanical behavior of cable tunnel driven by shield TBM is insufficient. Thus, in this study, the effect of fractured zone ahead of tunnel face on the mechanical behavior of the shield TBM cable tunnel is investigated. In addition, it is intended to compare the behavior characteristics of the fractured zone with continuous model and applying the interface elements. Tunnelling with shield TBM is simulated using 3D FEM. According to the change of the direction and magnitude of the fractured zone, Sectional forces such as axial force, shear force and bending moment are monitored and vertical displacement at the ground surface is measured. Based on the stability analysis with the results obtained from the numerical analysis, it is possible to predict fractured zone ahead of the shield TBM and ensure the stability of the tunnel structure.

Development of 2W-Level Wireless Powered Energy Harvesting Receiver using 60Hz power line in Electricity Cable Tunnel (전력구 내 지중선을 이용한 2W급 상용주파수 무선전력 수신장치 개발)

  • Jang, Gi-Chan;Choi, Bo-Hwan;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.296-301
    • /
    • 2016
  • Using high magnetic flux from a 60 Hz high-current cable, a 2 W wireless-powered energy harvesting receiver for sensor operation, internet of things (IoT) devices, and LED lights inside electrical cable tunnels is proposed. The proposed receiver comprises a copper coil with a high number of turns, a ring-shaped ferromagnetic core, a capacitor for compensating for the impedance of the coil in series, and a rectifier with various types of loads, such as sensors, IoT devices, and LEDs. To achieve safe and easy installation around the power cable, the proposed ring-shaped receiver is designed to easily open or close using a clothespin-shaped handle, which is made of highly-insulated plastic. Laminated silicon steel plates are assembled and used as the core because of their mechanical robustness and high saturation flux density characteristic, in which the thickness of each isolated plate is 0.3 mm. The series-connected resonant capacitor, which is appropriate for low-voltage applications, is used together with the proposed receiver coil. The concept of the figure of merit, which is the product weight and cost of both the silicon steel plate and the copper wire, is used for an optimized design; therefore, the weight of the fabricated receiver and the price of raw material is 750 gf and USD $2 each, respectively. The 2.2 W powering capability of the fabricated receiver was experimentally verified with a power cable current of $100A_{rms}$ at 60Hz.

The Dynamic Rating System(I) - Real Time Conductor Temperature Monitoring System (지중송전선로 실시간 송전용량 산정 시스템 개발(I) - 실시간 도체온도 산정 시스템)

  • Nam, S.H.;Lee, C.H.;Lee, S.K.;Baek, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1455-1457
    • /
    • 2002
  • The real-time dynamic rating system(DRS) can provide the maximum ampacity within required periods, so it can help the transmission-line operation more safely and efficiently. Because the conductor temperature is the main limit of increasing rating current, conductor temperature monitoring(CTM) technology is the basic to DRS. In this paper, real-time CTM was developed for 345kV XLPE cable in tunnel and we have also compared the CTM result of this study with the result according to IEC 287 and JCS 168 thermal parameters.

  • PDF

Surveillance System For Extra High Voltage Cable (초고압 CABLE 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Jeon, S.I.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF

Effect of compact HTS superconduction power cable and investigation of its economical efficiency (콤팩트형 고온 초전도 전력 케이블의 도입 효과와 경제성 검토)

  • 최상봉;성기철;조전욱;정성환;김대경
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.108-111
    • /
    • 2001
  • This paper presents the possible application of a HTS superconducting power cable for transmitting electric power in metropolitan areas, reflecting its important distinction such as compactness for installation in underground ducts and considerably economical efficiency comparable to present underground cables. In this paper, we investigated characteristic and market scale compact HTS transmission cable which is possible to install in underground ducts. And reviewed its economical efficiency comparing to present existed CV cable from point of view such as cost for cable construction and duct or tunnel installation.

  • PDF

A Case Study on the AC Corrosion Effects of Gas Pipeline by High Voltage Induction in Submarine Tunnel (해저터널내 고전압 유도에 의한 가스배관의 교류전식 영향 사례 연구)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.346-348
    • /
    • 2001
  • This paper analyze the interference problems, especially AC corrosion when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about AC corrosion, limitation of safety voltage, modeling of power cables, gas pipeline and grounding systems, analysis of induction voltage according to various circumstance, soil resistivity, length of tunnel. and so on.

  • PDF

Present Development Trends of 345kV XLPE Cables (345kV XLPE 케이블의 개발 현황)

  • Kim, Y.;Park, K.R.;Lee, S.H.;Heo, K.D.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1881-1883
    • /
    • 2002
  • Recently, 345kV XLPE Cable and Accessories have been developed and will be applied for Youngseo$\sim$Youngdeungpo project in Korea. So, let this project and the process of development introduce on this paper. The cable type and length of this project is 345kv XLPE 1C*$2000mm^2$ 66km and all cable will be pulled on cable tunnel. The diameter of cable insulation was designed as 27mm, we could reduce it by appling for hi-tech and super-clean system. Joints were developed by a pre-fabricated type which considered high safety and economic issues. We had also done Pre-Qualification test for verifying the reliance of cable and accessories before construction. As we developed this 345kV XLPE cable system including its accessories at the same time, we can have higher technologies and contribute safe power in transmission lines. In adtionally, we can have a stable status for suppling EHV cable systems to a variety foreign customers by ourselves.

  • PDF