• 제목/요약/키워드: power and energy consumption

검색결과 2,014건 처리시간 0.027초

LED 조명의 분광 분포에 따른 건물에너지 소비 (Energy consumption by Spectral Power Distribution Of LED lighting)

  • 정호연;김효인;김곤;윤근영
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.101-106
    • /
    • 2012
  • Lighting energy accounts for approximately 20% of the electrical energy used worldwide. Thus, High efficiency Light emitting diode(LED)lighting is getting more popular as the next generation lighting replaced to traditional lighting fixtures. Also, LED lighting not only has a long lifetime but also can realize a variety visual environments through the wavelengh control. The lighting energy varies depending on the Spectral Power Distribution(SPD) even though the Illuminance level is same. Therefore, This study indicates that the difference of indoor energy consumption under the same illuminance level when Spectral Power Distribution(SPD) is different. As a result, Lighting energy consumption under red-color emphasizing SPD is about 10% lower than under blue-color emphasizing SPDs.

The Relationship Between Income Inequality and Energy Consumption: A Pareto Optimal Approach

  • NAR, Mehmet
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권4호
    • /
    • pp.613-624
    • /
    • 2021
  • This paper analyzes the relationship between income distribution and energy consumption from a Pareto optimal approach. For this purpose, the causality relationship between electricity consumption per capita (kWh) with respect to country groups and energy consumption per capita (kg of oil equivalent) along with gross domestic product per capita was analyzed. In addition to this purpose, a Pareto analysis was conducted to determine the countries with the highest per capita national income, how much of the world total energy they consume, and whether the law of power in the energy and electricity markets exists. Finally, the impact of official development assistance provided to low-income countries by high-income countries on the low-income countries' electricity and energy consumption was analyzed. In other words, it was questioned whether pareto redistribution policies serve the purpose or not. The Engle-Granger causality approach was used in the analysis of the causality relationship between variables. Our analysis indicated that, first, the energy data of the country groups may be inadequate in revealing income inequalities. Second, the existence of Pareto law of power and global income inequality can be explained based on energy data. Finally, Pareto optimal redistribution policies to eliminate income inequality remain inadequate in practice.

한국 RE100 기업의 자가소비 태양광 발전 경제적 비율 분석 (Self-Consumption Solar PV Economic Rate Analysis for RE100 Companies in Korea)

  • 이종의;김경남
    • Current Photovoltaic Research
    • /
    • 제11권4호
    • /
    • pp.134-143
    • /
    • 2023
  • Efforts are being made to respond to global warming. Interest in and demand for the private sector-led RE100 campaign is also increasing. Self-built solar power generation, one of the implementation tools for RE100, is not expanding. However, it can be an economical means of implementation in the long run. In this study, we intend to analyze the impact on the optimal ratio of self-solar power generation using HOMER simulation. OPR defines the optimal solar power generation ratio and looks into what changes there are in the optimal solar power ratio when self-power consumption increases and external power purchase price changes. As a result, the optimal rate of self-solar power generation has a low impact even if self-power consumption increases. As the external power unit price increases, the optimal ratio increases, and at a power unit price of 100 KRW/kWh, OPR is 24%; at 200 KRW/kWh OPR is 31%; and at 300 KRW/kWh OPR is 34%. This shows that the electricity price replaced during the life cycle has a high impact on the economic feasibility of solar power generation. However, when the external power unit price reached a certain level, the increase in OPR decreased. This shows that it is difficult for domestic companies to achieve RE100 based on the economic feasibility of solar energy alone. Therefore, efforts are needed to supply renewable energy in the public sector.

원전 무선 센서 네트워크에 적합한 클러스터 헤드 체인 라우팅 프로토콜 (Cluster Head Chain Routing Protocol suitable for Wireless Sensor Networks in Nuclear Power Plants)

  • 정성민
    • 디지털산업정보학회논문지
    • /
    • 제16권2호
    • /
    • pp.61-68
    • /
    • 2020
  • Nuclear power plants have a lower cost of power generation, and they are more eco-friendly than other power generation plants. Also, we need to prepare nuclear plant accidents because of their severe damage. In the event of a safety accident, such as a radiation leak, by applying a wireless sensor network to a nuclear power plant, many sensor nodes can be used to monitor radiation and transmit information to an external base station to appropriately respond to the accident. However, applying a wireless sensor network to nuclear power plants requires routing protocols that consider the sensor network size and bypass obstacles such as plant buildings. In general, the hierarchical-based routing protocols are efficient in energy consumption. In this study, we look into the problems that may occur if hierarchical-based routing protocols are applied to nuclear power plants and propose improved routing protocols to solve these problems. Simulation results show that the proposed routing protocol is more effective in energy consumption than the existing LEACH protocol.

Power Consumption Analysis of Prominent Time Synchronization Protocols for Wireless Sensor Networks

  • Bae, Shi-Kyu
    • Journal of Information Processing Systems
    • /
    • 제10권2호
    • /
    • pp.300-313
    • /
    • 2014
  • Various Time Synchronization protocols for a Wireless Sensor Network (WSN) have been developed since time synchronization is important in many time-critical WSN applications. Aside from synchronization accuracy, energy constraint should also be considered seriously for time synchronization protocols in WSNs, which typically have limited power environments. This paper performs analysis of prominent WSN time synchronization protocols in terms of power consumption and test by simulation. In the analysis and simulation tests, each protocol shows different performance in terms of power consumption. This result is helpful in choosing or developing an appropriate time synchronization protocol that meets the requirements of synchronization accuracy and power consumption (or network lifetime) for a specific WSN application.

학교 건축물 전력소비의 기온감응도에 관한 연구 (A Study on Sensitivity to Temperature of Electricity Consumption in School Buildings)

  • 김태우;이강국;김호순;홍원화
    • 교육시설 논문지
    • /
    • 제18권5호
    • /
    • pp.13-21
    • /
    • 2011
  • In case of school buildings, energy consumption has been noticeably on the increase, along with the changes in outdoor temperature triggered by the improvement in national economic development and educational environments. Research on the characteristics of energy consumption in school buildings influenced by the changes in outdoor temperature is considered very significant in social aspects in that it will be fundamental to the suggestion of the alternatives, such as saving energy consumption in construction buildings and control of emitting carbon dioxide. In this regard, this study examined sensitivity to temperature of power consumption in school buildings, based on the changes of outdoor temperature for the past five years in the target buildings of elementary, middle and high schools and the amount of energy consumption. From the results, it has been believed that this study was very significant in terms of figuring out a quantitative, optimum level of energy consumption, maintenance of pleasant environments and functions, and the necessity of effective energy use and management in school buildings.

  • PDF

Energy and Service Level Agreement Aware Resource Allocation Heuristics for Cloud Data Centers

  • Sutha, K.;Nawaz, G.M.Kadhar
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권11호
    • /
    • pp.5357-5381
    • /
    • 2018
  • Cloud computing offers a wide range of on-demand resources over the internet. Utility-based resource allocation in cloud data centers significantly increases the number of cloud users. Heavy usage of cloud data center encounters many problems such as sacrificing system performance, increasing operational cost and high-energy consumption. Therefore, the result of the system damages the environment extremely due to heavy carbon (CO2) emission. However, dynamic allocation of energy-efficient resources in cloud data centers overcomes these problems. In this paper, we have proposed Energy and Service Level Agreement (SLA) Aware Resource Allocation Heuristic Algorithms. These algorithms are essential for reducing power consumption and SLA violation without diminishing the performance and Quality-of-Service (QoS) in cloud data centers. Our proposed model is organized as follows: a) SLA violation detection model is used to prevent Virtual Machines (VMs) from overloaded and underloaded host usage; b) for reducing power consumption of VMs, we have introduced Enhanced minPower and maxUtilization (EMPMU) VM migration policy; and c) efficient utilization of cloud resources and VM placement are achieved using SLA-aware Modified Best Fit Decreasing (MBFD) algorithm. We have validated our test results using CloudSim toolkit 3.0.3. Finally, experimental results have shown better resource utilization, reduced energy consumption and SLA violation in heterogeneous dynamic cloud environment.

업무용 건물의 용도 및 운전 기간별 에너지 소비 특성 연구 (A Study on the Energy Consumption Characteristics for Use and Operation Period in Office Buildings)

  • 박병훈;김시헌
    • 설비공학논문집
    • /
    • 제29권11호
    • /
    • pp.605-611
    • /
    • 2017
  • The purpose of this study is to calculate the energy consumption rate based on data regarding energy use in office buildings, and to confirm the general characteristics of energy consumption. The energy consumption rate of the building is calculated by dividing the energy consumption by the floor area. The energy consumption rate of small-sized office buildings was calculated as $101.48{\sim}201.55kWh/m^2{\cdot}year$ and in the case of medium-sized buildings, the range was $92.77{\sim}177.89kWh/m^2{\cdot}year$. In the case of small buildings, it was found that the energy consumption was $73.24kWh/m^2{\cdot}year$ in electronic device, $34.31kWh/m^2{\cdot}year$ in hot water supply, and $18.37kWh/m^2{\cdot}year$ in heating. In the case of medium-sized buildings, electronic devices was $73.08kWh/m^2{\cdot}year$, lighting was $18.35kWh/m^2{\cdot}year$ and heating, $15.37kWh/m^2{\cdot}year$. In all of the study buildings, the peak heating energy use was observed from 8:00 a.m. to 10:00 a.m during the winter, and the peak power management was required. Energy use at and around the midnight hour is confirmed to be 40~60% of weekly working hours, so it is necessary to manage power use at night time as well as during the day. In order to improve the accuracy of future studies, it is necessary to make efforts to secure the data with standardized energy measuring units for the various type of buildings.

공기압축기 소비에너지 평가에 관한 연구 (A Study on the Evaluation of Energy Consumption of the Air Compressor)

  • 장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권2호
    • /
    • pp.38-44
    • /
    • 2020
  • Various efforts have been initiated to reduce the energy consumption of the compressor as it is one of the approaches to saving a large portion of the fixed cost of the production site. Various results of reducing the energy consumption of the compressor have been reported, but to reduce the energy consumption of the compressors fundamentally, regular management of the compressor should ensure optimum operation. This requires periodic on-site visits by experts, but is often overlooked as a cost issue, resulting in the use of the compressor in low-efficiency conditions. Thus, it is necessary to develop a low-cost evaluation technology for compressor condition monitoring and efficiency analysis to ensure that the compressor is always driven at the optimum efficiency without imposing undue burden on the compressor user. In this study, a sensor was installed at the inlet, outlet, and power supply of the compressor, and a method for evaluating the energy consumption of the compressor using the minimum sensor was derived. The experimental results are presented to show the validity of the proposed method. It was confirmed that the energy consumption of the compressor can be easily as well as efficiently evaluated by using the method developed in this study.

임베디드 소프트웨어의 소모전력 분석을 위한 에너지 컴포넌트 라이브러리 (Energy Component Library for Power Consumption Analysis of Embedded Software)

  • 홍장의;김두환
    • 정보처리학회논문지D
    • /
    • 제16D권6호
    • /
    • pp.871-880
    • /
    • 2009
  • 임베디드 소프트웨어의 복잡성 및 대형화로 인하여 기능적 요구사항뿐만 아니라 소모전력 관리와 같은 비기능적 요구사항이 중요시되고 있다. 본 연구에서는 소스 코드 기반의 소모 전력을 분석하는 기존의 접근 방법과 달리 UML 2.0 기반의 모델을 중심으로 하는 임베디드 소프트웨어의 소모전력 분석 기법을 제시한다. 특히 소모 전력 분석을 위해 요구되는 에너지 컴포넌트에 대한 라이브러리 구축에 대하여 제시한다. 제시하는 라이브러리는 모델 기반의 소모전력 분석을 가능하도록 지원할 뿐만 아니라, 임베디드 응용의 변경에 따른 라이브러리 적용이 쉽게 이루어질 수 있다는 장점을 제공한다.