• 제목/요약/키워드: power and energy consumption

검색결과 2,014건 처리시간 0.036초

DC 1500V용 전철변전소의 회생전력량 분석 (Regenerative energy analysis in DC 1500V electric traction substations)

  • 배창한;장동욱;김용기;김성태;김병현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.836-845
    • /
    • 2007
  • In DC 1500V electric traction substations, diode rectifiers are commonly used to supply stable DC power with electric train sets. However, it operates in the first quadrant of the voltage-current plane and thus needs regenerative inverters which transfer the surplus regenerative power caused by regenerative braking of electric train sets into the grid. In order to select the proper capacity and installation position of regenerative inverter, it needs to investigate the consumed and regenerative energy of the electric traction substations in advance. This paper presents an analysis of regenerative energy in two substations operating in Seoul line 2 and Kwangju line 1. DC line voltage and feeder currents are measured for a day to calculate consumed and regenerative power for four feeders. We calculated an amount of regenerative energy consumed in other feeders and estimated the cost reduction in energy consumption due to the reuse of regenerative energy.

  • PDF

스마트 그리드에 그린 IT 활용 연구

  • 정현수;김병식;왕미경;김종훈;한명지
    • 한국데이타베이스학회:학술대회논문집
    • /
    • 한국데이타베이스학회 2010년도 춘계국제학술대회
    • /
    • pp.33-41
    • /
    • 2010
  • Recently the number of IT equipment have increased. It consumes large amounts of energy and is emissions of greenhouse gases. Co2 emissions with the PC and the monitor has the highest percentage to 39% more than other IT equipment. In addition, Plan for your PC's power management and technology development is being pursued in developed countries. To reduce energy costs of organizations with large numbers of the PC and to cut down on Co2 emissions, the energy load control technology of ACPI standards-based PC IS suggested. AMI-based PC power-management system was constructed, Approximately 20% of operating a result of the test power consumption was reduced. Looking at the case of the United States, PC monitors from the University of Wisconsin-Oshkosh was Sleep mode. As a result, the monitor on a, $ 20 for a year reduced energy costs. In GE(General Electronic), Approximately 75,000 PC's power setting time was Monitor Off :15 minutes/ Hard Drives Off 30 minutes/ System Standby 30 minutes/ Hibernation mode 2 hours. 1 year, electric bill was $ 2.5 million savings and 3 years electric bill was $ 6.5 million savings. Measuring energy usage data, using the measured data, electric energy management technology is not. Platform development to measure energy usage for Individual energy-consuming equipment is urgently required.

  • PDF

생태마을의 효과 및 보급에 관한 연구 -백암마을 사례를 중심으로- (A study on economical incentives and systems for promoting the eco-friendly village)

  • 임상훈
    • KIEAE Journal
    • /
    • 제7권1호
    • /
    • pp.41-48
    • /
    • 2007
  • This research has been carried out to give economical incentives and to promote for the eco-friendly village. A standard model plan for the Korean eco-village has been prepared by systematically applying the results of the research to Boksoo village, which served as an exemplary model. Plans for promoting the Korean eco-village are finally derived after a series of theoretical assessment of conceptual propositions in harnessing natural elements well suited with man-made structures. The eco-friendly village that this study is to develop harnesses natural energy resources and establishes pleasant living environment for human. It minimizes the unjust load against nature and restrains the excessive consumption of irreplaceable indigenous energy and other natural resources on earth. Paraphrasing, the utilization of natural energy resources in the eco-friendly village features various schemes of the related technologies in energy conservation and exploitation of renewable energies including solar thermal, photovoltaic, daylighting, wind power and etc. The eco-friendly village would definitely make our world more healthier than before by suppressing the emission of green house gases from fossil fuels and ever increasing energy consumption.

서보모터를 이용한 유압 하이브리드식 사출성형기의 공정시간 및 절전효과에 관한 연구 (A Study on Cycle Time and Power Saving Effect of a Hydraulic Hybrid Injection Molding Machine using a Servo Motor)

  • 윤홍식;김성동
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권3호
    • /
    • pp.15-25
    • /
    • 2020
  • The cycle time and power saving effect of a hydraulic hybrid injection molding machine using a servo motor are considered in this paper. In order to verify control characteristics, such as pressure and speed, experiments were performed with the hydraulic hybrid injection molding machine, clamping force of 110 ton. The power consumption and production cycle time of a conventional hydraulic injection molding machine were measured to compare its performances with the hydraulic hybrid injection molding machine. An injection molding machine with a clamping force of 1300 ton was used as the conventional machine, the hybrid machine was implemented by replacing its induction motors with servo motors. In the remodeled hybrid machine, experiments were performed to investigate how the displacement of the mold clamping pump affects the power consumption and production cycle time. The results showed that the production cycle time of the hybrid injection molding is similar to a conventional hydraulic injection molding machine but with a significant energy saving of about 40%.

AFA(All-Flash Array) 탑재 서버의 에너지 효율성에 대한 연구 (A Study on Energy Efficiency in Servers Adopting AFA(All-Flash Array))

  • 김영만;한재일
    • 한국IT서비스학회지
    • /
    • 제18권1호
    • /
    • pp.79-90
    • /
    • 2019
  • Maximizing energy efficiency minimizes the energy consumption of computation, storage and communications required for IT services, resulting in economic and environmental benefits. Recent advancement of flash and next generation non-volatile memory technology and price decrease of those memories have led to the rise of so-called AFA (All-Flash Array) storage devices made of flash or next generation non-volatile memory. Currently, the AFA devices are rapidly replacing traditional storages in the high-performance servers due to their fast input/output characteristics. However, it is not well known how effective the energy efficiency of the AFA devices in the real world. This paper shows input/output performance and power consumption of the AFA devices measured on the Linux XFS file system via experiments and discusses energy efficiency of the AFA devices in the real world.

전기자동차 에너지효율 평가를 위한 수치해석 연구 (Numerical Analysis Research for Evaluating the Energy Efficiency of Electric Vehicles)

  • 최민기
    • 한국분무공학회지
    • /
    • 제29권1호
    • /
    • pp.1-6
    • /
    • 2024
  • This paper is a numerical analysis study for evaluating the energy efficiency of electric vehicles. Currently, the methods for testing and evaluating the energy consumption efficiency of electric vehicles have limitations such as resources and time. Therefore, there is a need for research on developing models to predict the energy consumption efficiency of electric vehicles. In this study, a numerical analysis research is conducted to predict the energy efficiency of electric vehicles using a vehicle dynamics numerical analysis model. To validate the accuracy of the simulation model, it is compared the results of dynamometer tests with the simulation results and used the Unified Diagnostic Services (UDS) protocol to acquire internal data from the electric vehicle. It is ensured the reliability of the simulation model by comparing data such as motor speed, battery voltage, current, state of charge (SOC), regenerative braking power generation, and total driving distance of the test vehicle with dynamometer test data and simulation model results.

Energy Bad Smells 기반 소모전력 절감을 위한 코드 리팩토링 기법 (Code Refactoring Techniques Based on Energy Bad Smells for Reducing Energy Consumption)

  • 이제욱;김두환;홍장의
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제5권5호
    • /
    • pp.209-220
    • /
    • 2016
  • 최근 스마트폰, 태블릿과 같은 기기의 사용량이 증가하면서, 이에 탑재되는 소프트웨어는 더욱 복잡해지고 규모가 커지고 있다. 배터리의 전력으로 구동되는 모바일 기기들은 전력 공급의 한계로 인해 운용시간을 증가시키는 것이 중요한 이슈이다. 최근에는 소프트웨어 동작이 하드웨어 구동을 통해 전력 소모를 일으킨다는 점에서, 효율적인 동작 패턴을 갖는 소프트웨어 개발에 대한 연구들이 진행되고 있다. 그러나 모바일 기기에 탑재되는 소프트웨어는 그 개발 주기가 짧은 경우가 많아 최적화와 전력 소모량을 반영하기 어려운 경우가 많다. 따라서 본 연구에서는 소모전력 절감을 위한 코드 리팩토링 기법을 제안하여, 소프트웨어 개발 및 유지보수에서 보다 용이하게 저전력 요구사항을 충족시키고자 한다. 이를 위해 전력 소모량을 감소시킬 수 있는 코드 패턴에 대하여 Energy Bad Smell을 식별하고, 이를 제거하기 위한 새로운 코드 리팩토링 기법을 제안하며, 실험을 통해 그 효용성을 검증하였다.

선박디젤기관에서 바이오디젤연료의 연소특성에 대한 실험적 연구 (An Experimental Study on Combustion Characteristics of Biodiesel Fuel in Marine Diesel Engine)

  • 조상곤
    • 동력기계공학회지
    • /
    • 제19권3호
    • /
    • pp.29-35
    • /
    • 2015
  • Environmental pollution is produced by consumption of fossil fuel, therefore alternative fuels is interested for development of new energy resources and reduction of exhaust emissions for air pollution prevention. Biofuels are produced from new vegetable oil and animal fat, may be used as fuel without change of engine structure in diesel engine. In this paper, the test results on specific fuel consumption, combustion characteristics of neat diesel oil and biodiesel blends(10 vol.% biodiesel and 20 vol.% biodiesel) were presented using four stroke, direct injection diesel engine, especially this biodiesel was produced from biodiesel fuel at our laboratory by ourselves. This study showed that specific fuel consumption is increased slightly, on the other hand cylinder pressure, rate of pressure rise, rate of heat release and soot were decreased slightly in the case of biodiesel blends than neat diesel oil.

아파트의 전력부하밀도 및 전력소비 실태 분석 연구 (A Study on the Analysis of Power Load Density and Electric Power Consumption in Apartment Housing)

  • 이기홍;성세진
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.118-124
    • /
    • 2001
  • 아파트에서의 전력수요예측과 에너지 절약을 유도하기 위하여 본 연구에서는 1,080아파트 단지의 전력소비실태를 설문조사하여 전력부하밀도, 전력소비량, 설비의 현황 등을 분석·제시하였다. 분석 결과 연면적 대비 전력 부하밀도는 최대 7.70[VA/m2], 평균 6.0[VA/m2] 등으로 분석되었으며, 평균 부하율은 64[%]인 것으로 나타났다. 그리고 전국 아파트에서 년간 소비되는 전력량은 국내 총 소비전력량의 7[%]에 해당되는 14,008[GWh/년]으로 분석되었다.

  • PDF

0.1 MW급 연소후 습식아민 CO2 포집 Test Bed 공정개선효과 검증 (Process Improvement and Evaluation of 0.1 MW-scale Test Bed using Amine Solvent for Post-combustion CO2 Capture)

  • 박종민;조성필;임태영;이영일
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.103-108
    • /
    • 2016
  • Carbon Capture and Storage technologies are recognized as key solution to meet greenhouse gas emission standards to avoid climate change. Although MEA (monoethanolamine) is an effective amine solvent in $CO_2$ capture process, the application is limited by high energy consumption, i.e., reduction of 10% of efficiency of coal-fired power plants. Therefore the development of new solvent and improvement of $CO_2$ capture process are positively necessary. In this study, improvement of $CO_2$ capture process was investigated and applied to Test Bed for reducing energy consumption. Previously reported technologies were examined and prospective methods were determined by simulation. Among the prospective methods, four applicable methods were selected for applying to 0.1 MW Test Bed, such as change of packing material in absorption column, installing the Intercooling System to absorption column, installing Rich Amine Heater and remodeling of Amines Heat Exchanger. After the improvement construction of 0.1 MW Test Bed, the effects of each suggested method were evaluated by experimental results.