• 제목/요약/키워드: potential radiation dose

검색결과 202건 처리시간 0.029초

Evaluation of the heart and lung dosimetric parameters in deep inspiration breath hold using 3D Slicer

  • Eskandari, Azam;Nasseri, Shahrokh;Gholamhosseinian, Hamid;Hosseini, Sare;Farzaneh, Mohammad Javad Keikhai;Keramati, Alireza;Naji, Maryam;Rostami, Atefeh;Momennezhad, Mehdi
    • Radiation Oncology Journal
    • /
    • 제38권1호
    • /
    • pp.68-76
    • /
    • 2020
  • Purpose: The present study was conducted to compare dosimetric parameters for the heart and left lung between free breathing (FB) and deep inspiration breath hold (DIBH) and determine the most important potential factors associated with increasing the lung dose for left-sided breast radiotherapy using image analysis with 3D Slicer software. Materials and Methods: Computed tomography-simulation scans in FB and DIBH were obtained from 17 patients with left-sided breast cancer. After contouring, three-dimensional conformal plans were generated for them. The prescribed dose was 50 Gy to the clinical target volume. In addition to the dosimetric parameters, the irradiated volumes and both displacement magnitudes and vectors for the heart and left lung were assessed using 3D Slicer software. Results: The average of the heart mean dose (Dmean) decreased from 5.97 to 3.83 Gy and V25 from 7.60% to 3.29% using DIBH (p < 0.001). Furthermore, the average of Dmean for the left lung was changed from 8.67 to 8.95 Gy (p = 0.389) and V20 from 14.84% to 15.44% (p = 0.387). Both of the absolute and relative irradiated heart volumes decreased from 42.12 to 15.82 mL and 8.16% to 3.17%, respectively (p < 0.001); however, these parameters for the left lung increased from 124.32 to 223.27 mL (p < 0.001) and 13.33% to 13.99% (p = 0.350). In addition, the average of heart and left lung displacement magnitudes were calculated at 7.32 and 20.91 mm, respectively. Conclusion: The DIBH is an effective technique in the reduction of the heart dose for tangentially treated left sided-breast cancer patients, without a detrimental effect on the left lung.

전자선 조사를 이용한 히알루론산의 특성 조절 (Modulation of Hyaluronic Acid Properties by Electron Beam Irradiation)

  • 신영민;김우진;김용수;조선영;박종석;권희정;임윤묵;노영창
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.159-164
    • /
    • 2011
  • A variety of natural polymers have been used as tissue engineering scaffolds, drug delivery system, and cosmetic materials due to their higher biocompatibility and water uptake. As a major component of extracellular matrix, hyaluronic acid consisting of D-glucuronic acid and N-acetylglucosamine has been popularly used as a hydrogel material. Even though it has good properties to be used in the tissue engineering and cosmetic industry, its higher viscosity has limited a potential use in a variety of applications; only low content should be applied in preparing above products. In the present study, we investigated the effect of electron beam irradiation on the properties of hyaluronic acid. Hyaluronic acid paste containing low contents of water changed to solution after electron beam irradiation ranging from 1 to 10 kGy, which didn't exhibit any alteration of surface properties and morphological change after freeze-drying. However, its viscosity was significantly decreased as absorbed dose increased, which was approximately one by hundred in comparison with the viscosity of original hyaluronic acid solution with same concentration. In addition, it can still interact with positive charged chitosan generating polyelectrolyte complex. Therefore, only viscosity was decreased after electron beam irradiation, whereas other properties of hyaluronic acid maintained. Consequently, these hyaluronic acids with lower viscosities can be used in a variety of applications in tissue engineering, drug delivery, and cosmetic industry.

Mevatron KD 8067 선형가속기의 23 MV 광자선의 특성 (Characteristics of 23 MV Photon Beam from a Mevatron KD 8067 Dual Energy Linear Accelerator)

  • 김옥배;최태진;김영훈
    • Radiation Oncology Journal
    • /
    • 제8권1호
    • /
    • pp.115-124
    • /
    • 1990
  • 고 에너지 23MV광자선의 특성 중 임상적용에 중요한 심부선량 백분율, 조직-최대선량비 (TMR), 산란-최대선량비 (SMR), 표면선량 및 출력선량 보정계수등의 변수가 이온전리 (IC-10)함 및 평행 평판전리 (PS-033)함에 의해 측정 조사되었다. 명목상의 23 MV X-선에 대한 가속에너지는 $18.5\pm0.5$ MV로 측정되었다. Mevatron KD 8067의 23 MV X-선의 중심선속의 반가층이 기하학적인 좁은 선속으로 측정되었으며 반가층의 두께는 $24.5\;g/cm^2$이었다. 조직-최대선량비는 심부선량백분율표에서 구해졌으며, 실측치와 비교한 결과 각 조사면의 크기와 깊이에서 약간의 차이를 보였으나 평균 $0.7\pm0.5$의 오차를 나타내고 있어 계산에 의한 TMR 값과 잘 일치함을 보였다. 조사면 $0\times0\;cm^2$의 TMR 값은 zero 조사면의 유효감약계수에 의한 값과, 각 조사면의 조직-최대 선량비로 부터 비선형최소자승법에 의해 구해진 유효선흡수계수 및 반가층 측정에 의한 유효선흡수 계수에 의한 값들로 비교되었으며, $\mu=0.0283{\pm}0,0002cm^{-1}$을 보였고, 세 방법 모두 오차범위내에서 잘 일치됨을 보였다. 한편, 불규칙 조사면의 선량계산에 이용될 SMR은 조사면의 반경 50cm까지 계산되어 대형 조사 면에서도 선량율 산출이 이루어지도록 하였다. Mevatron KD 8067의 23 MV X-선의 조직 표면선량은 SSD 100 cm, 1$10\times10\;cm^2$의 조사면에서 최대조직선량율의 $9.6\%,\;25\times25\;cm^2$에서는 $25.4\%$를 보였다.

  • PDF

Chemoprevention of chemical-induced skin cancer by Panax ginseng root extract

  • Sharma, Jyoti;Goyal, Pradeep K.
    • Journal of Ginseng Research
    • /
    • 제39권3호
    • /
    • pp.265-273
    • /
    • 2015
  • Background: Cancer has emerged as a major health problem globally as a consequence to the increased longevity of the population, changing the environment and life style. Chemoprevention is a new and promising strategy for reducing cancer burden. Recently, some natural products have been identified for their chemopreventive activity to reduce the cancer incidence. Ginseng is known for its potential to treat various ailments in human beings. The present study was designed to explore the anticancer and antioxidative potential of Panax ginseng against chemical-induced skin carcinogenesis in mammals. Methods: Skin tumors were induced in Swiss albino mice by a single topical application of 7,12-dimethylbenz(a)anthracene ($100{\mu}g/100{\mu}L$ acetone) and, 2 wks later, promoted by repeated applications of croton oil (thrice in a wk in 1% acetone) till the end of the experiment (i.e., 16 wk). Hydroalcoholic ginseng root extract at a dose of 25 mg/kg body weight/d was orally administered at the periinitiation, postinitiation, and peri-post-initiation stages. Results: Ginseng root extract treatment caused a significant reduction in tumor incidence, cumulative number of tumors, tumor yield, and tumor burden, as compared to the 7,12-dimethylbenz(a)anthracene-croton oil-treated control group. Further, biochemical assays revealed a significant enhancement in the levels of reduced glutathione, superoxide dismutase, catalase, vitamin C, and total proteins but a significant reduction in lipid peroxidation levels in both the liver and skin with ginseng root extract treatment, as compared to carcinogen-treated control group. Conclusion: These results suggest that P. ginseng has the potential to become a pivotal chemopreventive agent that can reduce cancer in mammals.

전자선과 불가사리 분말을 이용한 하수슬러지 탈수능 향상 (Enhancement of Sludge Dewaterability using a Starfish and the Radiation Technology)

  • 유대현;이재광;이면주
    • 한국환경과학회지
    • /
    • 제13권7호
    • /
    • pp.681-687
    • /
    • 2004
  • This study was focused on the manufacturing method of a dewatering aid, which would reduce the water content of the sludge cake by enhancing the dewaterability of sewage sludge. The pretreatment technology for sludge by using radiation and among diverse discarded resources were starfish selected as the material to manufacture the dewatering aid. Starfish went through the process of washing, drying, and pulverizing. The starfish powder made in this process was applied to the digested sludge generated at the sewage treatment plant of D City, and its effects were investigated. The starfish powder that was 300 ${\mu}m$ in particle size was added to the irradiated digested sludge. After the application of the condensation process, the sludge with the starfish powder added was dewatered using the belt press and centrifuge, which were the traditional pressure dewatering devices. As the result, it reduced the water content of the sludge 20% higher than the dewatered cake with no dewatering aid added and irradiation. When the powder was added, it contributed to less use of the coagulant added. The more irradiation dose, the lower water content did the dewatered cake have and the more coagulant was needed for condensation, which seems to be a disadvantage that can be compensated for by the starfish dewatering aid. A small-scaled treatment of the study to a radiation technology and dewatering aid using a discarded resource confirmed the potential of dewaterability. Based on the results saying that the dewatering aid and radiation technology can improve dewatering effects using the traditional dewatering devices, this pretreatment technology will be expected to be applied to sewage treatment plants.

Assessment of inter- and intra-fractional volume of bladder and body contour by mega-voltage computed tomography in helical tomotherapy for pelvic malignancy

  • Kim, Sunghyun;You, Sei Hwan;Eum, Young Ju
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.235-240
    • /
    • 2018
  • Purpose: We describe the daily bladder volume change observed by mega-voltage computed tomography (MVCT) during pelvic radiotherapy with potential predictors of increased bladder volume variations. Materials and Methods: For 41 patients who received pelvic area irradiation, the volumes of bladder and pelvic body contour were measured twice a day with pre- and post-irradiation MVCT from the 1st to the 10th fraction. The median prescription dose was 20 Gy (range, 18 to 30 Gy) up to a 10th fraction. The upper and lower margin of MVCT scanning was consistent during the daily treatments. The median age was 69 years (range, 33 to 86 years) and 10 patients (24.4%) were treated postoperatively. Results: Overall bladder volume on planning computed tomography was 139.7 ± 92.8 mL. Generally, post-irradiation bladder volume (POSTBV) was larger than pre-irradiation bladder volume (PREBV) (p < 0.001). The mean PREBV and POSTBV was reduced after 10 fraction treatments by 21.3% (p = 0.028) and 25.4% (p = 0.007), respectively. The MVCT-scanned body contour volumes had a tendency to decrease as the treatment sessions progressed (p = 0.043 at the 8th fraction and p = 0.044 at the 10th fraction). There was a statistically significant correlation between bladder filling time and PREBV (p = 0.001). Conclusion: Daily MVCT-based bladder volume assessment was feasible both intra- and inter-fractionally.

조기 성문암 환자에서의 방사선치료 (Radiotherapy for Early Glottic Carinoma)

  • 김원택;남지호;권병현;왕수건;김동원
    • Radiation Oncology Journal
    • /
    • 제20권4호
    • /
    • pp.295-302
    • /
    • 2002
  • 목적 : 조기 성문암(T1-2N0M0) 환자들에 대한 일차적인 치료로서의 방사선치료의 역할과 치료결과에 영향을 미치는 예후인자들에 대한 분석을 통해 향후 치료방침을 세우는데 자료로 삼고자 연구를 시행하였다. 대상 및 방법 : 1987년 8월부터 1996년 12월까지 부산대학교병원 치료방사선과에서 조기 성문암으로 근치적 방사선 치료를 시행받은 환자 80명을 대상으로 후향적 분석을 시행하였다. T1 병기가 66명$(82.5\%)$, T2 병기가 14명$(17.5\%)$이였으며, 방사선치료는 6 MV X-선을 좌우 대칭조사야로 1일 1회 180 cGy 내지 2n cGy씩 주 5회 총 $ 6,000\~7,560\;cGy$ (중앙값 6,840 cGy)를 조사하였다. 치료기간은 40일에서 87일이었고 중앙값은 51일이었다. 모든 환자에서 최소 3년 이상 추적 조사하였다. 예후인자들에 대한 연구를 위해 T-병기, 종양의 위치, 총방사선량, 분할선량, 조사야의 크기 및 전체 방사선치료기간 등에 대한 단변량 및 다변량분석을 실시하였다. 결과 : 5년 생존율은 전체가 $89.2\%$였고 병기별로는 T1이 $90.2\%$, T2가 $82.5\%$였다. 국소제어율은 전체에서 $81.3\%$였고, T1 병기가 $83.3\%$, T2 병기가 $71.4\%$였으나 구제수술 후의 궁극적 국소제어율은 전체가 $91.3\%,\;T1\;94.5\%,\;T2\;79.4\%$$89.2\%$의 증가를 보였다. 음성보존율은 $89.2\%$로 T1과 T2에서 각각 $94.7\%$$81.3\%$로 유의한 차이를 보였다. 전체 환자 80명 중 15명에서 치료 후 재발을 보였고 이 중 국소재발(11/15, $73.3\%$)의 빈도가 가장 높았다. 예후 인자로 T-병기와 전체 치료기간이 단변량분석에서 통계적으로 의미를 주었으나 다변량분석에서는 전체 치료기간만이 유의한 인자였다. 결론 : 조기 성문암 환자의 치료에 근치적 방사선치료 및 구제수술의 조합은 높은 국소제어율과 함께 성문의 기능보존이라는 측면에서 효과적인 치료방법이라고 할 수 있으며, 치료결과에 영향을 줄 수 있는 예후인자들에 대해서는 추가적인 연구가 더 필요하겠으나 치료계획 단계에서부터 고려해야할 요소들로 생각된다.

원전 인허가승인을 위한 사고결말평가에서 지표침적에 의한 피폭의 민감도 분석 (Importance Analysis of Radiological Exposure by Ground Deposition in Potential Accident Consequences for the Licensing Approval of a Nuclear Power Plant)

  • 황원태;정해선;정효준;김은한;한문희
    • Journal of Radiation Protection and Research
    • /
    • 제39권2호
    • /
    • pp.89-95
    • /
    • 2014
  • 원전의 인허가 승인을 위한 사고결말평가에서 경수로는 미국의 규제지침에서 제시한 바와 같이 방사성물질의 지표침적의 고려를 허용하지 않고 있는데 반해 중수로의 규제지침에서는 이의 고려를 허용하고 있다. 이러한 배경에 따라 본 연구에서는 방사성물질의 지표침적에 의한 피폭영향의 민감도를 정량적으로 고찰, 분석하였다. 가상사고 시나리오를 구성하여 Cs-137과 I-131의 환경방출에 따른 총 피폭선량을 평가한 결과, 방사성물질의 지표침적과 이로 인한 공기중 농도의 감손을 고려치 않는 경우에 보다 보수적 결과를 나타냈다. 이는 지표침적에 의한 피폭선량이 총 피폭선량에 미치는 기여는 상대적으로 적은데 비해 지표침적으로 인한 공기중 농도의 감손이 총 피폭선량에 미치는 기여는 상대적으로 크기 때문이다. 대기안정도, 방출기간, 평가거리 등에 따라 차이는 있지만 두 핵종 모두 총 피폭선량에 대해 흡입에 의한 피폭이 90% 이상을 차지했으며, 지표침적에 의한 피폭은 기껏해야 10% 미만을 나타냈다. 지표침적의 고려에 따른 총 피폭선량의 감소는 $^{137}Cs$ 보다는$^{131}I$의 경우에 보다 컸으며, 대기가 안정하고 방출기간이 길수록, 그리고 방출점으로부터 평가지점이 멀수록 감소경향은 보다 뚜렷하게 나타났다.

Radiosensitivity and the Occurrence of Radiation-related Cataract and Epilation

  • Tomita, Makoto;Otake, Masanori;Moon, Sung-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • 제17권3호
    • /
    • pp.889-904
    • /
    • 2006
  • Our purpose is to ascertain, if possible, whether atomic bomb survivors with cataracts and epilation were more radiosensitive than those survivors with cataracts but without epilation. A major ophthalmologic survey was conducted in Hiroshima and Nagasaki in 1963-64. At that time, 2125 individuals were examined. Among these individuals, estimated eye organ doses, based on the DS86 dosimetry system, and information on the occurrence of epilation within the first 60 days following the bombings are available on 1742. In the analysis of these data we have assumed that each individual represents a sample of one from a binomial distribution, and that the occurrence of cataracts and epilation are independent biological phenomena. We got following results. The threshold for cataract induction and its 95% confidence limits have been estimated from data on the occurrence of cataract and epilation. Among the 1742 study subjects, 40 had both cataracts and severe epilation. The estimated threshold based on these cases is 0.98 sievert(Sv), with 95% lower and upper confidence bounds of 0.72, and 1.32 Sv, respectively, and is highly statistically significant. Among the 27 cases of cataracts where severe epilation was not reported, the estimated threshold is 1.74 Sv with 95% lower and upper confidence bounds of 1.21 Sv, and "not estimable". The difference between these two estimates is not statistically significant although the effect of dose is highly significant in both instances. The potential importance of biases in the DS86 dose estimates is discussed. The difference between the threshold estimated from cataract cases with epilation and that from cases without epilation is not statistically significant at the 5% or 10% level, and thus affords no support for the notion of increased radiosensitivity.

  • PDF

Development of a Computer Code for Low-and Intermediate-Level Radioactive Waste Disposal Safety Assessment

  • Park, J.W.;Kim, C.L.;Lee, E.Y.;Lee, Y.M.;Kang, C.H.;Zhou, W.;Kozak, M.W.
    • Journal of Radiation Protection and Research
    • /
    • 제29권1호
    • /
    • pp.41-48
    • /
    • 2004
  • A safety assessment code, called SAGE (Safety Assessment Groundwater Evaluation), has been developed to describe post-closure radionuclide releases and potential radiological doses for low- and intermediate-level radioactive waste (LILW) disposal in an engineered vault facility in Korea. The conceptual model implemented in the code is focused on the release of radionuclide from a gradually degrading engineered barrier system to an underlying unsaturated zone, thence to a saturated groundwater zone. The radionuclide transport equations are solved by spatially discretizing the disposal system into a series of compartments. Mass transfer between compartments is by diffusion/dispersion and advection. In all compartments, radionuclides ate decayed either as a single-member chain or as multi-member chains. The biosphere is represented as a set of steady-state, radionuclide-specific pathway dose conversion factors that are multiplied by the appropriate release rate from the far field for each pathway. The code has the capability to treat input parameters either deterministically or probabilistically. Parameter input is achieved through a user-friendly Graphical User Interface. An application is presented, which is compared against safety assessment results from the other computer codes, to benchmark the reliability of system-level conceptual modeling of the code.