• Title/Summary/Keyword: posttensioning

Search Result 5, Processing Time 0.015 seconds

Behaviour of Truss Bridges by Using the Post-tensioning (후긴장을 이용한 트러스의 성능 향상 평가)

  • Jeung, Bae-Keun;Han, Kyung-Bong;Eom, Jun-Sik;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.247-261
    • /
    • 2003
  • The technique of posttensioning has been used successfully to improve the performance of existing concrete structures. However, very few applications of this technique can be found in steel structures. Posttensioning by means of high strength cable or bar can be used to effectively increase the working load capacity of Truss Bridges. The benefits of posttensioning trusses can be achieved in strengthening of existing structures as well as in the design of new structures. In this paper, the elastic behavior of posttensioned trusses with straight and draped tendon profiles is examined. For the analysis of posttensioned trusses in the elastic range of behavior, two methods are presented, namely, the flexibility method and the mixed-method, i.e., a combination of the stiffness and flexibility methods. Using the presented methods, the effects of design variables such as the tendon profile, truss type, prestress force, and tendon eccentricity on the working load and deflection of trusses are studied. The results show that the allowable load of truss increases proportionally with increase in prestress force and eccentricity. Posttesioning enlarges the elastic range, increases redundancy, and reduces deflection and member stresses. Thus, the remaining life of a truss bridge can be increased relatively inexpensively.

Structural Performance on the Self-centering Connections with Different Conditions of PT Strands (긴장재 적용조건에 따른 셀프센터링 접합부의 구조성능에 관한 연구)

  • Jung, Mi Jin;Yoon, Sung Kee
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.1
    • /
    • pp.73-80
    • /
    • 2017
  • In this study, cyclic loading analysis was conducted in order to understand the behavior of self-centering connections based on the number of PT(posttensioning) strands and initial posttensioning force. The initial posttensioning force needs to be above the yield moment of an angle for obtaining noticeable self-centering effect and it is proper that decompression moment ratio needs to be below 0.35 to minimize the residual displacement of major elements. As the number of PT strands increased, self-centering capacity also improved since initial posttensiong force in each PT strand has been decreased. It is also appropriate that initial posttensiong force needs to be less than or equal to 75% of yield strength of PT strands.

Seismic Behavior of Precast Frames with Hybrid Beam-Column Connections

  • Moon, Jeong-Ho;Lee, Yong-Ju
    • KCI Concrete Journal
    • /
    • v.11 no.3
    • /
    • pp.191-199
    • /
    • 1999
  • A Precast frame system with hybrid beam-column connections was proposed in this study. An analytical study evaluated the system under seismic loadings. Four buildings with different heights were modeled in which each building had three types of joint details (A. B, C). Thus, twelve buildings were examined with variables such as building height and joint detail. Four earthquake records were applied to the buildings as input ground motions. All the records were normalized to the intensity of 0.25g to assess behavior under the same intensity of seismic excitation. All the joint types showed almost identical results except for the Mexico earthquake which was scaled up from 0. 1g to 0.25g. Buildings with the type C joint exhibited the largest deflection for the Mexico earthquake. It was concluded that type B joint could be used in a high seismic zone and the type C joint could possibly be used in the regions of low to medium seismic activity.

  • PDF

Development of Analysis Technique for Structural Behavior of Containment with Bonded-Type Tendons (CANDU Type) (원전 부착식 텐던 격납건물의 구조거동 분석기법 개발 I-CANDU형)

  • Lee, Sang-Keun;Park, Sang-Soon;Lee, Sang-Min;Cho, Myong-Seok;Song, Young-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.643-646
    • /
    • 2004
  • The posttensioning system of nuclear containment have to be verified its structural integrity by the periodic inspection because the structural behavior of the containment is changed by the variation of the physical property of concrete and tendon as time passes. In this study a program 'SAPONC-CANDU' which is able to monitor and analysis the micro structural behavior of the domestic CANDU type containment at all times was developed. The readings of vibrating-wire strain gauges embedded into the concrete of containment were used as input data for operating the program. This program provides the long-term prediction values and bands of the concrete strain due to the time dependent factors of the concrete and tendon of the domestic CANDU type containment.

  • PDF

Analytical investigation on lateral load responses of self-centering walls with distributed vertical dampers

  • Huang, Xiaogang;Zhou, Zhen;Zhu, Dongping
    • Structural Engineering and Mechanics
    • /
    • v.72 no.3
    • /
    • pp.355-366
    • /
    • 2019
  • Self-centering wall (SCW) is a resilient and sustainable structural system which incorporates unbonded posttensioning (PT) tendons to provide self-centering (SC) capacity along with supplementary dissipators to dissipate seismic energy. Hysteretic energy dissipators are usually placed at two sides of SCWs to facilitate ease of postearthquake examination and convenient replacement. To achieve a good prediction for the skeleton curve of the wall, this paper firstly developed an analytical investigation on lateral load responses of self-centering walls with distributed vertical dampers (VD-SCWs) using the concept of elastic theory. A simplified method for the calculation of limit state points is developed and validated by experimental results and can be used in the design of the system. Based on the analytical results, parametric analysis is conducted to investigate the influence of damper and tendon parameters on the performance of VD-SCWs. The results show that the proposed approach has a better prediction accuracy with less computational effects than the Perez method. As compared with previous experimental results, the proposed method achieves up to 60.1% additional accuracy at the effective linear limit (DLL) of SCWs. The base shear at point DLL is increased by 62.5% when the damper force is increased from 0kN to 80kN. The wall stiffness after point ELL is reduced by 69.5% when the tendon stiffness is reduced by 75.0%. The roof deformation at point LLP is reduced by 74.1% when the initial tendon stress is increased from $0.45f_{pu}$ to $0.65f_{pu}$.