• Title/Summary/Keyword: post-tensioning anchorage

Search Result 21, Processing Time 0.025 seconds

Load Transfer Characteristics of Post-Tensioning Anchorage (포스트텐션용 정착구의 하중전달 특성에 관한 연구)

  • 김민수;김진근;유영섭;이상순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.657-662
    • /
    • 2000
  • This paper presents the results from experimental study that investigated to explore the load transfer characteristics of post-tensioning anchorage zones. The experimental program investigated the primary variables which affect the ultimate load, lateral strains and crack width: concrete compressive strength, details of reinforcement and shape of anchorage. Through this research, it was found that the governing factor of the ultimate load was not compressive cylinder strength but tensile splitting strength. Ultimate load was increased and lateral strain was decreased as the ratio of spiral increased because the lateral expansion of th concrete inside the spiral was restrained by the spiral. Furthermore, the shape of anchorage which can diminish the wedge effect of anchorage and disperse the anchorage force in various depths was more effective.

  • PDF

Strengthening Evaluation of Post-Tensioning Due to Anchorage System (정착방법에 따른 외부 프리스트레이트 도입공법의 보강성능 평가)

  • 박승범;홍석주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.279-284
    • /
    • 2000
  • The bridge is nation's principal structure and its influence for national economy is enormous. But it is essential for maintenance of deteriorated bridge because of the increased service life and the decreased performance. For the bridge reinforced by continuos slabs and post-tensioning, we evaluate th stress properties of girders and internal support. Results are almost coincidence between measured data in the field and analysed data by computer. We compared the effects by successive order of post- tensioning and order considered distribution of each girder's camber and stress. Bridge's camber and stress showed respectively symmetry and asymmetry shape by post tensioning order. For the effect of post-tensioning force partition, we divided the post-tensioning force into 3 types (100%, 20%, 30%), and the results show t도 difference of final stress and camber.

  • PDF

Development and Analysis of Unbonded Post-tensioned Anchorage for Single Tendon (비부착식 단일 강연선용 포스트텐션 정착구 개발 및 응력해석)

  • Lee, Young Hak;Cho, Yong Woo;Kim, Min Sook
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • In this paper, an unbonded post-tensioning anchorage for a single-stranded wire that allows more efficient stress distribution in the post-tensioned anchorage zone was developed by using a finite element analysis using a commercial program. The stress analysis was carried out using a 3D model in the anchorage zone of the concrete member using the developed anchorage. The result of analysis ensured that the developed anchorage reduced the maximum bursting stress in anchorage zone compared to the case of existing anchorage and the location where maximum bursting stress also occurred closer to the anchorage. Bursting force was calculated using AASHTO, modified $M{\ddot{o}}rsch$ and Stone. As a result, it was concluded that an effective reinforcement design of the anchorage zone can be designed by modified $M{\ddot{o}}rsch$.

Post-tensioning System with Externally Unbonded CFRP Strips for Strengthening RC Members (RC 부재의 휨 보강을 위한 외부 비부착형 탄소섬유판 포스트텐션 시스템)

  • You, Young-Chan;Choi, Ki-Sun;Kim, Keung-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.147-154
    • /
    • 2008
  • Experimental study has been performed in order to investigate the behavior of RC beams strengthened with externally unbonded post-tensioned CFRP (Carbon Fiber Reinforced Polymer) strips using embedded or stud-type plate anchorages. Total 10 small-scaled specimens were manufactured with the different post-tensioning level and types of mechanical anchorage as a main test parameter. A control specimen and specimens with simply bonded CFRP strips were included to compare the structural performances of each system. From the test results, it was observed that the specimens strengthened with simply bonded CFRP strips showed debonding failure below 50% of CFRP tensile strength due to premature debonding. On the other hand, all the specimens strengthened with post- tensioned unbonded CFRP strips reached the rupture strength of the CFRP strip. Also, it was observed that the specimens with stud-type anchorage have equivalent strengthening performance compared with embedded-type anchorage.

A Study on the Reinforcement of Steel Composite Beam Using the External Post-Tensioning Method (외부 후 긴장 공법을 이용한 강합성보의 보강에 관한 연구)

  • Park, Yong-Gul;Park, Young-Hoon;Lee, Seung-Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.549-558
    • /
    • 2000
  • In strengthening structure, the external post-tensioning method which secure clearness in the structure analysis process is adopted to bridges as well as architecture structure. In this study, to investigate the behavior of composite beam in the process of post-tensioning, the amount of prestress force loss, the amount of prestressed compression stress at the lower flange and the behavior of lower flange connected with anchorage are analyzed by comparing the results of finite element analysis with the measured results of installed strain gauges. After finishing the post-tensioning, the strengthening effect of external post-tensioning method is analyzed by static loading test. It is also investigated that the strengthening effect of shear section in the harped external post-tensioning specimens.

  • PDF

Load Transfer Test of Spirally Reinforced Anchorage Zone for Banded Tendon Group (나선형 원형철근으로 보강된 집중배치 텐던 정착구역에 대한 하중전달시험)

  • Cho, Ah Sir;Kang, Thomas H.K.
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.1
    • /
    • pp.59-67
    • /
    • 2017
  • In this study, load transfer tests based on KCI-PS101 were conducted to verify the performance of spiral anchorage zone reinforcement for banded post-tensioning (PT) monostrands. With results, the compressive strength of spiral reinforcement was increased by about 20% than that of specimens with two horizontal steel bars and 8% than that of U-shaped bars. Advanced spiral reinforcement for corner increases compressive strength and can resist the spalling forces or fall-out effect at the corner by shear. The ratio of maximum load to amount of steel of the spiral reinforcement is about twice than that of U-shaped reinforcement. With increase of compressive strength capacity and improvement of constructability, the spiral reinforcement is considered to have advantages of promoting the performance of PT anchorage zone compared to conventional methods.

Influence of steel fiber and reinforcing details on the ultimate bearing strength of the post-tensioning anchorage zone

  • Kim, Jin-Kook;Yang, Jun-Mo;Kwon, Yangsu
    • Structural Engineering and Mechanics
    • /
    • v.59 no.5
    • /
    • pp.867-883
    • /
    • 2016
  • In this paper, the effects of steel-fiber and rebar reinforcements on the ultimate bearing strength of the local anchorage zone were investigated based on experiments and comparisons between test results and design-equation predictions (AASHTO 2012, NCHRP 1994). Eighteen specimens were fabricated using the same anchorage device, which is one of the conventional anchorage devices, and two transverse ribs were used to secure an additional bearing area for a compact anchorage-zone design. Eight of the specimens were reinforced with only steel fiber and are of two concrete strengths, while six were reinforced with only rebars for two concrete strengths. The other four specimens were reinforced with both rebars and steel fiber for one concrete strength. The test and the comparisons between the design-equation predictions and the test results showed that the ultimate bearing strength and the section efficiency are highly affected by the reinforcement details and the concrete strength; moreover, the NCHRP equation can be conservatively applied to various local anchorage zones for the prediction of the ultimate bearing strength, whereby conditions such as the consideration of the rib area and the calibration factor are changed.

Experimental Analysis of Anchorage Zone Design for Unbonded Post-Tensioned Concrete Beam With 2400MPa Single Tendons (2400MPa 단일 강연선이 적용된 포스트텐션 정착 구역 설계에 대한 실험적 연구)

  • Moon, Sang Pil;Ro, Kyong Min;Kim, Min Sook;Lee, Young Hak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.1
    • /
    • pp.41-48
    • /
    • 2020
  • In this study, the design of anchorage zone for unbonded post-tensioned concrete beam with single tendons of ultimate strength 2400MPa was evaluated to verify that the KDS 14 20 60(2016) and KHBDC 2010 codes are applicable. The experimental results showed that the bursting force equation of current design codes underestimated bursting stress measured by test, because the KDS 14 20 60(2016) and KHBDC 2010 propose the location of the maximum bursting force 0.5h which is the half of the height of member regardless of stress contribution. Although the allowable bearing force calculated by current design codes was not satisfied the prestressing force, the cracks and failure in anchorage zone was not observed due to the strengthening effect of anchorage zone reinforcement.

Bursting Force Equation for Design in Unbonded Post-Tensioned Anchorage Zone (비부착 포스트텐션 정착구역 설계를 위한 파열력 산정 방법)

  • Ro, Kyong Min;Lee, Young Hak
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.21-26
    • /
    • 2018
  • For evaluating equations of bursting force in different codes, comparative study of the formulas was conducted. Because the equations does not consider variables such as shape of anchorages and duct, a relation between the bursting forces and the variables has to be analyzed. In this paper, the bursting forces equation was proposed by finite element analysis. As evaluation through comparison of the proposed equation with the previous ones and an experiment, it was figured out that bursting force computed by the proposed equation could be used for design of reinforcement in the anchorage zone.

The Load Transfer Performance of Post-tension Anchorage with 2,400 MPa Strands (2,400 MPa 강연선용 포스트텐션 정착구의 하중전달성능)

  • Kim, Sun-Woo;Lho, Byeong-Cheol;Lim, Jung-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.63-71
    • /
    • 2018
  • Strands with ultimate strength of 2,400 MPa was developed and applied in the KCI Code and the KS standard. A high-strength prestressed strand to be applied to a structure, a suitable anchorage system should be used together. Recently, a post tension anchorage for 2,400 MPa strands was developed. but there is not much research on performance evaluation. Therefore, in this study, structural analysis of local zone with 9 strands, 15 strands, and 19 strands anchorage were investigated respectively, which are most widely used for post tensioning anchorages with 2,400 MPa strands, according to PTI anchorage zone design method, and Load transfer performance from ETAG013 and/or KCI-PS101 was evaluated. Furthermore, the adequacy of the test was also analyzed by nonlinear numerical analysis. As results, the anchorages with 2,400 MPa strands satisfied the structural performance of the local area and satisfied the load transfer performance condition.