• 제목/요약/키워드: post-peak strength

검색결과 137건 처리시간 0.024초

Efficient repair of damaged FRP-reinforced geopolymeric columns using carbon fiber reinforced polymers

  • Mohamed Hechmi El Ouni;Ali Raza;Khawar Ali
    • Structural Engineering and Mechanics
    • /
    • 제87권6호
    • /
    • pp.585-599
    • /
    • 2023
  • Geopolymer concrete (GC) can be competently utilized as a practical replacement for cement to prevent a high carbon footprint and to give a direction toward sustainable concrete construction. Moreover, previous studies mostly focused on the axial response of glass fiber reinforced polymer (glass-FRP) concrete compressive elements without determining the effectiveness of repairing them after their partial damage. The goal of this study is to assess the structural effectiveness of partially damaged GC columns that have been restored using carbon fiber reinforced polymer (carbon-FRP). Bars made of glass-FRP and helix made of glass-FRP are used to reinforce these columns. For comparative study, six of the twelve circular specimens-each measuring 300 mm×1200 mm-are reinforced with steel bars, while the other four are axially strengthened using glass-FRP bars (referred to as GSG columns). The broken columns are repaired and strengthened using carbon-FRP sheets after the specimens have been subjected to concentric and eccentric compression until a 30% loss in axial strength is attained in the post-peak phase. The study investigates the effects of various variables on important response metrics like axial strength, axial deflection, load-deflection response, stiffness index, strength index, ductility index, and damage response. These variables include concentric and eccentric compression, helix pitch, steel bars, carbon-FRP wrapping, and glass-FRP bars. Both before and after the quick repair process, these metrics are evaluated. The results of the investigation show that the axial strengths of the reconstructed SSG and GSG columns are, respectively, 15.3% and 20.9% higher than those of their original counterparts. In addition, compared to their SSG counterparts, the repaired GSG samples exhibit an improvement in average ductility indices of 2.92% and a drop in average stiffness indices of 3.2%.

원자로압력용기용 SA508 Gr.4N Ni-Mo-Cr계 저합금강 용접열영향부의 용접후열처리에 따른 미세조직과 기계적 특성 평가 (Evaluation of Microstructure and Mechanical Properties on Post-Weld Heat Treatment in the Heat Affected Zone of SA508 Gr.4N Ni-Mo-Cr Low Alloy Steel for Reactor Pressure Vessel)

  • 이윤선;김민철;이봉상;이창희
    • 대한금속재료학회지
    • /
    • 제47권3호
    • /
    • pp.139-146
    • /
    • 2009
  • The heat-affected zone (HAZ) of SA508 Gr.4N Ni-Mo-Cr low alloy steel, which has higher Ni and Cr contents than SA508 Gr.3 Mn-Mo-Ni low alloy steel, was investigated on the microstructure and mechanical properties. The HAZ was categorized into seven characteristic zones (CGCG, FGCG, ICCG, SCCG, FGFG, ICIC and SCSC-HAZ) according to the peak temperature from the thermal cycle experienced during multi-pass welding. Post Weld Heat Treatment (PWHT) was conducted in the temperature range of $550{\sim}610^{\circ}C$ for 30 hours to evaluate the effect of PWHT conditions on the microstructure and mechanical properties. Before PWHT, CGHAZ and FGFGHAZ showed high yield strength (YS) ranging from 1000 to 1250 MPa, while YS of SCSCHAZ decreased from 607 MPa (observed for base metal) to 501 MPa. The Charpy impact energies of sub-HAZs fell below 100J at $-29^{\circ}C$, except in the SCSCHAZ. By applying PWHT to sub-HAZ specimens, YS decreased as the PWHT temperature increased. In the case of CGHAZs and FGFGHAZ heat-treated at $610^{\circ}C$, YS dropped drastically to the range of 654~686 MPa. From the Charpy impact test, the upper-shelf energy (USE) increased to approximately 250J and Index temperature ($T_{68J}$) decreased below $-50^{\circ}C$. Specifically, in FGFG, ICIC and SCSC-HAZ, $T_{68J}$ was below -110, which was lower than the case of base metal.

고강도 앵글을 적용한 선조립 합성기둥의 압축 실험 (Compression Test for Prefabricated Composite Columns Using High-Strength Steel Angles)

  • 황현종;엄태성;박홍근;이창남;김형섭
    • 한국강구조학회 논문집
    • /
    • 제24권4호
    • /
    • pp.361-369
    • /
    • 2012
  • 본 연구에서는 고강도 앵글을 사용한 선조립 합성기둥(PSRC 합성기둥)을 연구하였다. 2/3 축소모델의 PSRC 실험체 및 단면 중앙부에 H형강을 매입한 일반 SRC 실험체를 제작하여 중심압축실험을 수행하였다. 강재비와 횡철근 간격을 실험 변수로 고려하였다. 실험결과 단면 코너부 앵글에 의한 콘크리트 구속효과로 인하여 PSRC 합성기둥 실험체는 일반 SRC 합성기둥과 비교하여 하중 재하능력 및 변형능력이 우수한 것으로 나타났다. 또한 KBC 2009 설계기준에 의한 공칭압축강도보다 높은 하중저항능력을 나타냈다. 기존의 횡보강 콘크리트 재료모델을 적용하여 단면해석을 수행한 결과, 초기강성, 최대강도, 최대강도 이후의 강도 및 강성 저하 등에서 실험 및 해석결과가 비교적 잘 일치하는 것으로 나타났다.

거친 절리면의 전단거동 해석을 위한 탄소성 구성법칙 (An Elasto-Plastic Constitutive Law for Modeling the Shear Behavior of Rough Rock Joints)

  • 이연규;이정인
    • 터널과지하공간
    • /
    • 제8권3호
    • /
    • pp.234-248
    • /
    • 1998
  • 거친 절리면의 수직팽창 특성이 전단거동에 미치는 영향을 고려할 수 있는 새로운 전단거동 구성법책을 탄소성이론에 근거하여 제시하였다. 공식화 과정에서는 항복함수 및 소성포텐셜 함수로 Barton의 경험적 강도식들이 이용되었다. 전단강도의 경화 및 연화현상을 반영시키기 이해 mobilized JRC 개념이 적용되었다. 최대전단강도 이전과 이후의 JRC 변화는 절리면 전단방향 소성일의 함수로 표현할 수 있다고 가정하였다. 제안된 구성모델을 개별체 절리 유한요소에 적용하여 실행시켰다. 경계조건을 달리한 수치 직접전단시험을 통하여 제안된 모델을 검증하였다. 해석결과는 여러 문헌에 보고된 실험결과들과 잘 일치하였다. 또한 제안된 모델은 거친 절리면의 전단시험에서 특징적으로 나타나는 현상들을 잘 모사할 수 있음을 보였다.

  • PDF

Simulation study on effects of loading rate on uniaxial compression failure of composite rock-coal layer

  • Chen, Shao J.;Yin, Da W.;Jiang, N.;Wang, F.;Guo, Wei J.
    • Geomechanics and Engineering
    • /
    • 제17권4호
    • /
    • pp.333-342
    • /
    • 2019
  • Geological dynamic hazards during coal mining can be caused by the failure of a composite system consisting of roof rock and coal layers, subject to different loading rates due to different advancing velocities in the working face. In this paper, the uniaxial compression test simulations on the composite rock-coal layers were performed using $PFC^{2D}$ software and especially the effects of loading rate on the stress-strain behavior, strength characteristics and crack nucleation, propagation and coalescence in a composite layer were analyzed. In addition, considering the composite layer, the mechanisms for the advanced bore decompression in coal to prevent the geological dynamic hazards at a rapid advancing velocity of working face were explored. The uniaxial compressive strength and peak strain are found to increase with the increase of loading rate. After post-peak point, the stress-strain curve shows a steep stepped drop at a low loading rate, while the stress-strain curve exhibits a slowly progressive decrease at a high loading rate. The cracking mainly occurs within coal, and no apparent cracking is observed for rock. While at a high loading rate, the rock near the bedding plane is damaged by rapid crack propagation in coal. The cracking pattern is not a single shear zone, but exhibits as two simultaneously propagating shear zones in a "X" shape. Following this, the coal breaks into many pieces and the fragment size and number increase with loading rate. Whereas a low loading rate promotes the development of tensile crack, the failure pattern shows a V-shaped hybrid shear and tensile failure. The shear failure becomes dominant with an increasing loading rate. Meanwhile, with the increase of loading rate, the width of the main shear failure zone increases. Moreover, the advanced bore decompression changes the physical property and energy accumulation conditions of the composite layer, which increases the strain energy dissipation, and the occurrence possibility of geological dynamic hazards is reduced at a rapid advancing velocity of working face.

사면안정 해석과 댐 거동분석을 통한 Carsington Dam 파괴의 고찰 (Assessment of Carsington Dam Failure by Slope Stability and Dam Behavior Analyses)

  • 송정락;김성인
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1991년도 추계학술발표회 논문집 지반공학에서의 컴퓨터 활용 COMPUTER UTILIZATION IN GEOTECHNICAL ENGINEERING
    • /
    • pp.87-102
    • /
    • 1991
  • 영국 잉글랜드 지방의 Carsington Dam의 파괴원인은 설계시 발견되지 못한 댐 상류 사면 하부의 황색점토층의 존재와 이미 존재하던 전단변형에 기인한 것으로 보고되었다. 설계시 황색 점토층과 이미 존재하던 전단변형을 고려하지 않고 전통적인 원호파괴 양상으로 검토된 사면의 안전율은 1.4 이상으로 나타났다. 그러나 댐 파괴후 황색 점토층과 이미 존재하던 전단변형을 고려한 사면의 안전율은 약 1.0으로 보고되었다. 또한 파괴후 사면에 대한 유한 요소 해석결과로 부터 파괴 토괴의 절편에 작용하는 수평력은 수평에 대해서 약 10。아래로 작용하고 있음이 보고되었다. 본 고에서는 Bishop의 간편법과 Janbu 방법 및 Morgenstern-Price 방법을 이용하여 원호형 사면파괴양상과 특정 파괴면을 따라서 일어나는 쐐기형 파괴양상에 대하여 사면안정을 검토하였으며, 이미 존재하던 전단변형과 이에 따른 토괴의 연속적인 거동은 이미 주어진 지반 특성을 이용한 강도정수와 간극수압비에 의하여 고려하였다. 그 결과 확생 점토층을 무시하고 원호형 파괴 양상에 대하여 Bishop의 간편법에 의한 설계 시점에서의 안전율은 1.387로 나타났으며(STABL), 파괴 후의 지반자료를 이용하고, 황색점토층을 고려한 안전율을 Janbu 방법의 경우 1.012(STABL), 그리고 Morgenstern-Price 방법의 경우 0.969을 보여주었다(MALE). 또한 Cam-Clay Model을 이용한 유한 요소 해석용 프로그램을 이용하여 댐 제체의 거동을 검토하였다. 이때 댐 제체의 성토 작업 및 압밀진행에 따른 간극수압변화와, 파괴시 혹은 파괴에 임박한 상태에서의 제체의 거동은 적절하게 가정된 지반의 응력-변형률 관계와 간극수압특성에 의하여 고려되었다. 그 결과 응력 및 변위가 심하게 발생하는 지역은 황색 점토층이었으며 이로부터 황색 점토층에서 부터 파괴면이 생성되어 다른 지역으로 전파되었음을 유추할 수 있었다.form trap with 2.88[eV] deep of injected space charge from the chathode in the crystaline regions. The origin of ${\alpha}$$_2$ peak was regarded as the detrapping process of ions trapped with 0.9[eV] deep originated from impurity-ion remained in the specimen during production process of the material, in the crystalline regions. The origin of ${\beta}$ peak was concluded to be due to the depolarization process of "C=0"dipole with the activation energy of 0.75[eV] in the amorphous regions. The origin of ${\gamma}$ peak was responsible to the process combined with the depolarization of "CH$_3$", chain segment, with the activation energy of carriers from the shallow trap with 0.4[eV], in he amorphous regions.의 증발산율은 우기의 기상자료를 이용하여 구한 결과 0.05 - 0.10 mm/hr 의 범위로서 이로 인한 강우손실량은 큰 의미가 없음을 알았다.재발이 나타난 3례의 환자를 제외한 9례 (75%)에서는 현재까지 재발소견을 보이지 않고 있다. 이러한 결과는 다른 보고자들과 유사한 결과를 보이고 있지만 아직까지 증례가 많지 않기 때문에 생존율을 얻기에는 미흡

  • PDF

관통구를 갖는 판구조물의 강도평가 방법에 관한 연구 (A Study on the Strength Evaluation Method of Plate Structures with Penetration-holes)

  • 김을년;장준태
    • 대한조선학회논문집
    • /
    • 제54권6호
    • /
    • pp.476-484
    • /
    • 2017
  • The purpose of this paper is to verify the structural integrity of a region with numerous penetration-holes in offshore structures such as semi-submersible rig and FPSO. In order to effectively check the yielding and buckling strength of plate members with penetration-holes, a screening analysis program was developed with the FE analysis tool to generate fine meshed model using the theoretical and analysis methods. When a hole is appeared in the plate structure members, the flow of stress is altered such that concentrations of stress form near the hole. Stress concentrations are of concern during both preliminary and detail design and need to be addressed from the perspectives of strength. To configure the geometrical shape, very fine meshed FE analysis is needed as the most accurate method. However, this method is practically impossible to apply for the strength verifications for all perforated plates. In this paper, screening analysis method was introduced to reduce analysis tasks prior to detailed FE analysis. This method is applied to not only the peak stress calculation combined stress concentration factor with nominal stress but also nominal equivalent stress calculation considering cutout effects. The areas investigated by very fine meshed analysis were to be chosen through screening analysis without any reinforcements for penetration-holes. If screening analysis results did not satisfy the acceptance criteria, direct FE analysis method as the 2nd step approach were applied with one of the coarse meshed model considering hole or with the very fine meshed model considering the hole shape and size. In order to effectively perform the local fine meshed analysis, automatic model generating program was developed based on the MSC/PATRAN which is pre-post FE analysis program. Buckling strength was also evaluated by Common Structure Rule (CSR) adopted by IACS as the stress obtained from very fine meshed FE analysis. Due to development of the screening analysis program and automatic FE modeling program, it was able to reduce the design periods and structural analysis costs.

Effects of radiant exposure and wavelength spectrum of light-curing units on chemical and physical properties of resin cements

  • Lima, Adriano Fonseca;Formaggio, Stephanie Ellen Ferreira;Zambelli, Ligia Franca Aires;Palialol, Alan Rodrigo Muniz;Marchi, Giselle Maria;Saraceni, Cintia Helena Coury;de Oliveira, Marcelo Tavares
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.271-277
    • /
    • 2016
  • Objectives: In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs) on the degree of conversion (DC) and the mechanical properties of resin cements. Materials and Methods: Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG), according to the different radiant exposures (5, 10, and $20J/cm^2$) and two LCUs (single-peak and polywave). The specimens were made (7 mm in length ${\times}$ 2 mm in width ${\times}$ 1 mm in height) using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E) by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA) and post hoc Tukey's test were performed. Results: No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols. Conclusions: On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.

Investigation of the Characteristics of New, Uniform, Extremely Small Iron-Based Nanoparticles as T1 Contrast Agents for MRI

  • Young Ho So;Whal Lee;Eun-Ah Park;Pan Ki Kim
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1708-1718
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate the magnetic resonance (MR) characteristics and applicability of new, uniform, extremely small iron-based nanoparticles (ESIONs) with 3-4-nm iron cores using contrast-enhanced magnetic resonance angiography (MRA). Materials and Methods: Seven types of ESIONs were used in phantom and animal experiments with 1.5T, 3T, and 4.7T scanners. The MR characteristics of the ESIONs were evaluated via phantom experiments. With the ESIONs selected by the phantom experiments, animal experiments were performed on eight rabbits. In the animal experiments, the in vivo kinetics and enhancement effect of the ESIONs were evaluated using half-diluted and non-diluted ESIONs. The between-group differences were assessed using a linear mixed model. A commercially available gadolinium-based contrast agent (GBCA) was used as a control. Results: All ESIONs showed a good T1 shortening effect and were applicable for MRA at 1.5T and 3T. The relaxivity ratio of the ESIONs increased with increasing magnetic field strength. In the animal experiments, the ESIONs showed peak signal intensity on the first-pass images and persistent vascular enhancement until 90 minutes. On the 1-week follow-up images, the ESIONs were nearly washed out from the vascular structures and organs. The peak signal intensity on the first-pass images showed no significant difference between the non-diluted ESIONs with 3-mm iron cores and GBCA (p = 1.000). On the 10-minutes post-contrast images, the non-diluted ESIONs showed a significantly higher signal intensity than did the GBCA (p < 0.001). Conclusion: In the phantom experiments, the ESIONs with 3-4-nm iron oxide cores showed a good T1 shortening effect at 1.5T and 3T. In the animal experiments, the ESIONs with 3-nm iron cores showed comparable enhancement on the first-pass images and superior enhancement effect on the delayed images compared to the commercially available GBCA at 3T.

Impact of time and frequency domain ground motion modification on the response of a SDOF system

  • Carlson, Clinton P.;Zekkos, Dimitrios;McCormick, Jason P.
    • Earthquakes and Structures
    • /
    • 제7권6호
    • /
    • pp.1283-1301
    • /
    • 2014
  • Ground motion modification is extensively used in seismic design of civil infrastructure, especially where few or no recorded ground motions representative of the design scenario are available. A site in Los Angeles, California is used as a study site and 28 ground motions consistent with the design earthquake scenario are selected. The suite of 28 ground motions is scaled and modified in the time domain (TD) and frequency domain (FD) before being used as input to a bilinear SDOF system. The median structural responses to the suites of scaled, TD-modified, and FD-modified motions, along with ratios of he modified-to-scaled responses, are investigated for SDOF systems with different periods, strength ratios, and post-yield stiffness ratios. Overall, little difference (less than 20%) is observed in the peak structural accelerations, velocities, and displacements; displacement ductility; and absolute accelerations caused by the TD-modified and FD-modified motions when compared to the responses caused by the scaled motions. The energy absorbed by the system when the modified motions are used as input is more than 20% greater than when scaled motions are used as input. The observed trends in the structural response are predominantly the result of changes in the ground motion characteristics caused by modification.