• Title/Summary/Keyword: post-operation

Search Result 1,164, Processing Time 0.114 seconds

Recent advances in the characterization and the treatment methods of effluent organic matter

  • Ray, Schindra Kumar;Truong, Hai Bang;Arshad, Zeshan;Shin, Hyun Sang;Hur, Jin
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.257-274
    • /
    • 2020
  • There are many previous review articles are available to summarize either the characterization methods of effluent organic matter (EfOM) or the individual control treatment options. However, there has been no attempt made to compare in parallel the physicochemical treatment options that target the removal of EfOM from biological treatments. This review deals with the recent progress on the characterization of EfOM and the novel technologies developed for EfOM treatment. Based on the publications after 2010, the advantages and the limitations of several popularly used analytical tools are discussed for EfOM characterization, which include UV-visible and fluorescence spectroscopy, Fourier transform infrared spectroscopy (FTIR), size exclusion chromatography (SEC), and Fourier transform-ion cyclotron resonance-mass spectrometry (FT-ICR-MS). It is a recent trend to combine an SEC system with various types of detectors, because it can successfully track the chemical/functional composition of EfOM, which varies across a continuum of different molecular sizes. FT-ICR-MS is the most powerful tool to detect EfOM at molecular levels. However, it is noted that this method has rarely been utilized to understand the changes of EfOM in pre-treatment or post-treatment systems. Although membrane filtration is still the preferred method to treat EfOM before its discharge due to its high separation selectivity, the minimum requirements for additional chemicals, the ease of scaling up, and the continuous operation, recent advances in ion exchange and advanced oxidation processes are greatly noteworthy. Recent progress in the non-membrane technologies, which are based on novel materials, are expected to enhance the removal efficiency of EfOM and even make it feasible to selectively remove undesirable fractions/compounds from bulk EfOM.

Reconstruction of Combined Oral Mucosa-Mandibular Defects Using the Vascularized Myoosseous Iliac Crest Free Flap

  • Jung, Hwi-Dong;Nam, Woong;Cha, In-Ho;Kim, Hyung Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.4137-4140
    • /
    • 2012
  • The authors present five cases of combined oral mucosa-mandible defects reconstructed with the vascularized internal oblique-iliac crest myoosseous free flap. This technique has many advantages compared to other conventional methods such as the radial flap, scapula flap, and fibula flap. Vascularized iliac crest flaps provide sufficient high-quality bone suitable for reconstructing segmental madibular defects. Although fibular flaps allow longer donor bone tissue to be harvested, the iliac crest can provide an esthetic shape for mandibular body reconstruction and also provides sufficient bone height for dental implants. Conventional vascularized iliac crest myoosseous flaps have excessive soft tissue bulk for reconstruction of intraoral soft tissue defects. The modification discussed in the present article can reduce soft tissue volume, resulting in better functional reconstruction of the oral mucosa. Another advantage is that complete replacement of the oral mucosa is observed in as early as one month post-operation. The final mucosal texture is much better than that obtained with other skin paddle flaps, which is especially beneficial for the placement of dental implant prostheses. Donor site morbidity looks to be similar to, if not less than that observed for other modalities in terms of function and esthetics. For combined oral mucosa-mandible defects, the vascularized internal oblique-iliac crest myoosseous free flap shows good results with respect to hard and soft tissue reconstruction.

Percutaneous Radiofrequency Ablation Guided by Contrast-enhanced Ultrasound in Treatment of Metastatic Hepatocellular Carcinoma after Liver Transplantation

  • Dai, Xin;Zhao, Hong-Qiang;Liu, Run-Hao;Xu, Chang-Tao;Zheng, Fang;Yu, Li-Bao;Li, Wei-Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3709-3712
    • /
    • 2012
  • This study evaluated the advantages and applications of contrast-enhanced ultrasound (CEUS)-supported percutaneous radiofrequency ablation (RFA) in the treatment of metastatic hepatocellular carcinoma after liver transplantation, based on clinical details. CEUS-supported percutaneous RFA was adopted to treat 12 patients with hepatic metastatic carcinomas after liver transplantation. The diameters of the metastatic carcinomas varied from 1 cm to 5 cm, and the foci were discovered after 3 months to 12 months. Each focus was diagnosed and localised by CEUS for RFA once or twice. Curative effects were evaluated by CEUS or contrast-enhanced CT after the treatment. The re-examination results at 2 weeks post-treatment showed that the foci of 11 patients were ablated completely, whereas one patient with the largest focus required retreatment by RFA because of a partial residue. No local recurrence was found one month later in the re-examination. CEUS-supported percutaneous RFA in the treatment of hepatic metastatic carcinoma after liver transplantation has the advantages of accurate localisation, good efficacy, easy operation, and minimal invasion without any complications. Therefore, it can be recommended as the preferred therapy for hepatic metastatic carcinoma after liver transplantation.

Thermal Stability and High Exchange Coupling Field of Bottom Type IrMn-Pinned Spin Valve (Bottom형 IrMn 스핀밸브 박막의 열적안정성과 높은 교환결합력)

  • Hwang, J.Y.;Kim, M.Y.;Rhee, J.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.2
    • /
    • pp.64-67
    • /
    • 2002
  • IrMn pinned spin valve (SV) films with stacks of Ta/NiFe/IrMn/CoFe/Cu/CoFe/NiFe/Ta were prepared by dc sputtering onto thermally oxidized Si (111) substrates at room temperature under a magnetic field of about 100 Oe. The annealing cycle number and temperature dependence of exchange coupling field (H$_{ex}$), magnetoresistance (MR) ratio, and coercivity (H$_{c}$) were investigated. By optimizing the process of deposition and post thermal annealing condition, we obtained the IrMn based SV films with MR ratio of 3.6%, H$_{ex}$ of 1180 Oe for the pinned layer. The H$_{ex}$ is stabilized after the second annealing cycle and it is thought that this SV reveals high thermal stability. The H$_{ex}$ maintained its strength of 600 Oe in operation up to 24$0^{\circ}C$ and decreased monotonically to zero at 27$0^{\circ}C$.

The Effect of Learning Community Program Participation on College Students' Communication Skills and Cooperative Learning Competency (학습공동체 프로그램 참여가 대학생의 의사소통능력 및 협동학습역량에 미치는 영향)

  • Cho, Bo-Ram
    • Journal of Digital Convergence
    • /
    • v.18 no.5
    • /
    • pp.43-54
    • /
    • 2020
  • The purpose of this study was to investigate the effects of participation in the learning community program on the communication skills and cooperative learning capabilities of college students. To this end, in the second semester of 2018, pre and post surveys were conducted on 296 students at A University and analyzed using SPSS. The main research results are as follows. First, there was a significant difference in the participation of the learning community program in the cooperative learning capacity of college students. Second, in the analysis by sub-factors, there were significant differences before and after the program in the factors of cooperative learning competency learning participation and learning satisfaction. Third, the differences between grades showed significant differences between the 2nd and 3rd grades before and after the program. Fourth, based on the results of this study, suggestions were made for learning community program activities and follow-up studies. The results of this study analyzed the effects of learning community activities conducted at universities on the communication skills and cooperative learning capabilities of college students, and presented practical measures for the systematic operation and support of learning community activities.

Study on Integrated Storage Systems for Automobile Production (자동차 생산을 위한 통합창고 연구)

  • Ok, Chang-Hun;Kim, Duk-Su;Gong, Jung-Su;Seo, Yoon-Ho
    • Journal of the Korea Society for Simulation
    • /
    • v.21 no.2
    • /
    • pp.91-101
    • /
    • 2012
  • Automobile manufacturing consists of body-line, painting-line, and assembly-line. These production lines are disposed in series and go through a flow process, so according to the status of pre & post processing, a suspension happens in a line by a starvation(impossibility of production by insufficient supply) or blocking(impossibility of production by exceed capacity). Therefore, to prevent a loss of production coming from a starvation or blocking, a storage such as WBS or PBS is independently owned and operated. The paper suggests the simulation model of integrated storage which can operate it by integrating each storage performing a role as a buffer of line. Specifically, the paper found the answers about reasonable number of Stacker Crane and AGV(Automatic Guided Vehicle) and suggested a methodology of operation which is available to operate them. Also, it compared an efficiency between a model of current storage and integrated storage through simulation. As a result, it turned out that the model suggested in the paper was more efficient on suspension of painting-line stop than a current storage.

Suppression of Dielectric Loss at High Temperature in (Bi1/2Na1/2)TiO3 Ceramic by Controlling A-site Cation Deficiency and Heat Treatment

  • Lee, Ju-Hyeon;Lee, Geon-Ju;Pham, Thuy-Linh;Lee, Jong-Sook;Jo, Wook
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.7-13
    • /
    • 2020
  • Dielectric capacitors are integral components in electronic devices that protect the electric circuit by providing modulated steady voltage. Explosive growth of the electric automobile market has resulted in an increasing demand for dielectric capacitors that can operate at temperatures as high as 400 ℃. To surpass the operation temperature limit of currently available commercial capacitors that operate in temperatures up to 125 ℃, Bi1/2Na1/2TiO3 (BNT), which has a large temperature-insensitive dielectric response with a maximum dielectric permittivity temperature of 300 ℃, was selected. By introducing an intentional A-site cation deficiency and post-heat treatment, we successfully manage to control the dielectric properties of BNT to use it for high-temperature applications. The key feature of this new BNT is remarkable reduction in dielectric loss (0.36 to 0.018) at high temperature (300 ℃). Structural, dielectric, and electrical properties of this newly developed BNT were systematically investigated to understand the underlying mechanism.

Bankart Suture Repair for Anterior Instability of the Shoulder- Results of Arthroscopic versus Open Repair - (견관절 전방 재발성 탈구의 치료-관절경 및 관혈적 Bankart병변 수복술의 비교 -)

  • Choi, Chang-Hyuk;Kwun, Koing-Woo;Kim, Shin-Kun;Lee, Sang-Wook;Shin, Dong-Kyu;Kim, Kyung-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.5 no.1
    • /
    • pp.47-54
    • /
    • 2002
  • Purpose : We evaluated clinical result of arthroscopic and open Bankart repair in anterior shoulder instability to identify factors iuluencing operative result and prognosis. Materials & Methods . We reviewed 24 patients of anterior shoulder instability treated with arthroscopic Bankart repair in 16 cases and open Bankart repair in 8 cases. Average age was 26 years old and involved in dominant arm in 15 cases. Patients were suffered instability for 3.1 years before operation and mean follow-up was 2 year 9 months ( 1 you 9 months -4year 10 months). Results : Post operative pain was subsided in 2 weeks in arthroscopic surgery and 3 weeks in open surgery. The final range of motion after arthroscopic repair were flekion in 168" , external rotation in 54" , and internal rotation in 79, and after open repair 168" ,49" , and 78 respectively. In arthroscopic surgery,2 cases (13%) were redislocated, and 4 cases(25%) showed mild instability. In open case,1 case (11%) showed mild instability. According to function- al result by Rowe grading scale, satisfactory results were 12case (76%) in arthroscopic repair and 7 cases (88%) in open cases. Conclusions Both arthroscopic or open Bankart could get good results in the treatment of anterior instability of shoulder. In arthroscopic repair, perioperative morbidity was lower than open repair, but it needs careful rehabilitation program to prevent redislocation and to return to sports activity.

Usefullness with 3D CT Angiography in Microsurgical Reconstruction (미세수술을 이용한 하지의 재건시 삼차원 컴퓨터 혈관조영술의 유용성)

  • Sung, Yong Duck;Kim, Hyo Heon
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.175-180
    • /
    • 2006
  • Preoperative angiography is frequently used in the planning of microsurgical reconstruction for identification of vascular abnormality that influence the planning of operation. But, recently 3D CT angiography is considered as new technique that can provide detailed information about vascular anatomy as well as soft and bony tissue without the risks of invasive angiography. 3D CT angiograms were performed in 19 patients before microsurgical reconstruction for the lower extremity and hand between May of 2003 and Oct of 2004. Sixteen of the studies were of the donor site and all of 19 studies were of the recipient site. No complications were found from the 3D CT angiograms. In one case of the bone exposed open wound, the injury of anterior tibial artery was identified and the zone of injury was adequately demonstrated. With the improvement in quality of CT imaging, 3D CT angiograms may provide a favorable alternative to invasive angiography. It is capable of providing high-resolution, three dimensional vascular imaging without the need for arterial puncture and prolonged post-procedure observation. The relation among blood vessels, bones, and soft tissue is well demonstrated in 3D CT angiogram. Also The acquisition time and examination cost were considerably lower in comparison with invasive angiography. In conclusion, this study demonstrates that 3D CT angiography may provide accurate, safe, and cost-effective preoperative imaging. The 3D CT angiography with relatively low morbidity, low cost, ease of image acquisition can have an broader role in microsurgical reconstructive surgery.

Recent Trend of the Reduction Mammaplasty and comparing with Vertical Reduction Method and Inverted T-scar Method (유방축소술의 최근 경향 및 수직반흔법과 역T자반흔법의 비교)

  • Kwon, Ki-Hyun;Lim, Young-Bin;Jo, Myung-Soo;Shin, Hae-Kyung;Seul, Jung-Hyun
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.300-308
    • /
    • 2011
  • Purpose: The goal of reduction mammaplasty is breast with natural cone shape, minimizing scars, well-placed and sensate nipple-areolar area and maintaining breast physiology. In order to satisfy that goal, variable reduction mammaplasty methods are performed, however, two methods such as vertical reduction method and inverted T-scar method are currently most used. We compared indications and advantages of the two methods and set up useful guidlines. Methods: For 15 years from 1995 to 2010, we experienced 84 patients (162 breasts). We performed vertical reduction method as Lejour's superior pedicle technique (45 patients) and inverted T-scar method as Goldwyn's inferior dermal flap technique (39 patients). We evaluated the result of the operation comparing patient's age, amount of resected tissue, complications and post-operative scars of the two methods. Results: The mean age was 36 years and the vertical reduction group was 3 years younger than inverted T-scar group. The mean breast tissue resection amount per one breast, inverted T-scar group (712 gm) was lagger than vertical reduction group (395 gm). Conclusion: There is no ideal method for reduction mammaplasty until now. However, we suggest that guide line, the vertical reduction method is effective for minimal and moderate macromastia in young and middle aged women and inverted T-scar method is appropriate for severe macromastia with ptosis in elderly women. Recently, all procedures tried shorter and smaller scar on the vertical line as small I, J or L shape scar, and inframammary fold as short inverted T-scar.