• Title/Summary/Keyword: post-curing

Search Result 139, Processing Time 0.031 seconds

Structural Behavior of Retrofitted RC beams with Fire Damages (화재 피해를 입은 일반강도 RC 보의 보수성능)

  • 안주희;신영수;이차돈;홍성걸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1013-1016
    • /
    • 2003
  • This paper is to evaluate practically the techniques and materials of repair for RC elements with fire damages as well as to investigate the structural behavior of RC beams according to pre- or post-repair after fire-damages. For this purpose, normal concrete flexural specimens were exposed to high temperatures by the ISO 834 specification. After natural cooling and post-fire-curing in a natural environment for 2 months, the specimens were repaired with polymer cement mortar for 1 month curing.

  • PDF

Adhesion properties and Breakdown behaviors of LSR Interface (LSR 계면의 접착특성 및 절연파괴거동)

  • Yoon, Seung-Hoon;Nam, Jin-Ho;Lee, Gun-Ju;Choi, Soo-Geol;Shin, Doo-Sung;Ji, Eung-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.232-235
    • /
    • 2002
  • Recently developed liquid silicone rubber (LSR) can be cured by platinum catalyzed additional hydrosilylation mechanism and has the advantage of no byproduct compared to traditional millable peroxide curing silicone rubber. We investigated the characteristics of dielectric breakdown of silicone rubber and adhesion properties between semi-conductive LSR and insulating LSR for high voltage application of pre-molded joint (PMJ). In order to understand the dielectric breakdown characteristics, we used the sheet samples and the paired type rogowski insert electrode system. The breakdown strength and adhesion strength of LSR (E-3) were superior to those of several silicone rubbers. Adhesion strength could be improved by curing at high temperature without post-curing process or enhanced by post-curing process. When LSR (E-3) was cured at $(150^{\circ}C{\times}10min$ semi-conductive )${\times}$ ($175^{\circ}C{\times}10min$ insulation), it showed the high breakdown strength with low standard deviation, and good adhesion strength. In this results, we could apply this process to the fabrication of PMJ without post-curing.

  • PDF

EFFECT OF CURING METHODS OF RESIN CEMENTS ON BOND STRENGTH AND ADHESIVE INTERFACE OF POST (레진시멘트의 중합방법이 포스트의 결합강도와 접착계면에 미치는 영향)

  • Kim, Mun-Hang;Kim, Hae-Jung;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.103-112
    • /
    • 2009
  • The purpose of this study was to compare the effect of curing methods of adhesive resins and resin cements in the root canal. Crown portions of 32 single-rooted mandibular premolars were removed. Routine endodontic treatment was done, and 9 mm deep post spaces were prepared within root canals. No.3 FRC Postec posts (Ivoclar-Vivadent AG, Liechtensteih) were cemented in the post spaces by self-(SC) or light-curing (LC) using two dual-cured adhesives (Adper Scotchbond multi-purpose plus and Exite DSC )and resin cements (RelyX ARC and Variolink II). They were assigned to 4 groups (n=8): R-SC, R-LC, V-SC, V-LC group. After stored in distilled water for 24 hours, each root was transversally sectioned with 1.5 mm thick and made three slices. The specimens were subjected to push-out test in a universal testing machine (EZ Test, Shimadzu Co., Japan) with a crosshead speed of 1 mm/min. The data were analyzed with repeated ANOVA and one-way ANOVA. Also the interface of post-resin cement and resin cement-canal wall of each group was observed under FE-SEM. When fiber posts were cemented into the root canal using total-etch adhesives, the bond strength and adaptation between post and root canal dentin was affected by curing method. Self-cure of adhesives and resin cements showed higher bond strength and closer adaptation than light-cure of them.

Cure Characteristics of Metal Particle Filled DGEBA/MDA/SN/ zeolite Composite System for EMI Shielding

  • Cho, Young-Shin;Lee, Hong-Ki;Shim, Mi-Ja;Kim, Sang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.548-551
    • /
    • 1999
  • The cure characteristics of metal particle filled DGEBA/MDA/SN/ zeolite epoxy resin composite system for EMI shielding were investigated by dynamic DSC run method and FT-lR spectroscopy. As the heating rate increased, the peak temperature on dynamic DSC curve increased because of the rapid cure reaction. From the straight line of the Kissinger plot, the curing reaction activation energy and pre-exponential factor could be obtained. As the post-curing time at 15$0^{\circ}C$ increased, the glass increased the glass transition temperature or the thermal stability increased. When the post curing time is too long, the system filled with metallic Al particle can be thermally oxidized by the catalytic reaction of metal filler and the thermal stability of the composite for the EMI shielding application may be decreased.

  • PDF

New curing method using gaseous oxidant on sweet potato (Ipomoea batatas)

  • Jin, Hyunjung;Kim, Wook
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.39-39
    • /
    • 2017
  • In Asia, sweet potato (Ipomoea batatas) is a very important crop for starch production. Approximately 74.3% of the total sweet potato production quantity is produced in Asia (FAO, 2014) and China is the largest producer of sweet potato. Post-harvest management is particularly important because it is difficult to maintain the quality as well as quantity of sweet potatoes. Despite the importance of post-harvest management, researches on sweet potato have been focused on production-related study such as breeding of new variety, improved techniques of cultivation, so there is limited research on storage after harvest. Curing is a normal practice after sweet potato harvest to promote wound healing and extend postharvest storage life. In Korea, harvested sweet potatoes are usually cured for 4 to 7 days at $30-33^{\circ}C$ and 80-95% relative humidity within one week. Since the optimum storage temperature of sweet potato is regarded as $15-20^{\circ}C$, additional facilities and costs are required to raise the temperature for curing. However, the majority of small farmers do not have the capacity to provide additional facilities and costs. This study was initiated to suggest a new curing method to accelerate the wound healing by applying chemical oxidation to the wound surface of sweet potato. Oxidative stress is known to play an important role in the synthesis of secondary metabolites including lignin. In addition, chemical oxidation can be applied to prevent spoilage caused by microorganisms. Powerful gaseous oxidant with excellent penetration ability and superior sterilization effect was selected for this study. Lignification, weight loss, and spoilage rate of artificially wounded sweet potatoes were investigated after oxidant fumigation. There were clear differences in morphological analysis such as lignification pattern, lignin deposition color, and continuity of lignified cell layers between oxidant-fumigated sweet potatoes and control. These results show that gaseous oxidant can be used to supplement or replace the curing practice, to improve shelf-life as well as curing cost reduction.

  • PDF

Comparative analysis of the flexural strength of provisional restorative resins using a digital light processing printer according to the post-curing method (디지털 광원 처리 프린터로 제작된 임시수복용 레진의 후경화 기계에 따른 굴곡강도 연구)

  • Park, Young-Dae;Kang, Wol
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.341-347
    • /
    • 2020
  • Purpose: This study aimed to evaluate the effect of post-curing method on the flexural strength of provisional restorative resins produced by a digital light processing printer. Methods: A total of 20 specimens were produced, with a length of 64 mm, width of 10 mm, and thickness of 3.3 mm using a digital light processing printer. Two types of provisional restorative resins made with different post-curing methods were investigated and divided into conventional and vacuum groups. For the flexural strength test, each group was prepared by each method according to ISO 10477, and the flexural strength was measured with a universal testing machine. For statistical analysis, data were analyzed by independent t-test and Mann-Whitney U test. Results: The flexural strengths of the conventional and vacuum groups were 151.89 MPa and 131.94 MPa, respectively, showing a statistically significant difference (p<0.05). Conclusion: Within the limitation of this study, provisional restorative resins produced with vacuum demonstrated lower flexural strength than those produced with conventional postcuring method.

Preferential face coating of knitted PET fabrics via UV curing for water- and oil-repellent finish (자외선 경화에 의한 PET 니트직물의 편면 발수발유 가공)

  • Jeong, Yong-Kyun;Jeong, Yongjin;Jang, Jinho
    • Textile Coloration and Finishing
    • /
    • v.17 no.6 s.85
    • /
    • pp.27-35
    • /
    • 2005
  • Conventional pad- dry-cure(thermo-fixation) process usually produces functional performance on both sides of a fabric. UV curing technique was applied to impart water- and oil-repellent finish effective only on the face of a PET knitted fabric. The preferential one-side coating, by virtue of the limited penetration of UV light, was achieved by W curing after padding of a fluorocarbon agent without special coating or printing equipments. The difference in the functional property of face and back sides was examined by measuring water and oil repellency at each side of the treated fabric. The influence of pre/post-irradiation dose and agent concentration on the performance of the finished fabrics were investigated. While increase in both resin concentration and post-irradiation did not have significant effect on the finish, UV pre-irradiation of PET fabrics caused remarkable influence presumably due to appropriate surface modification of PET fabrics required for facile wetting of the resin. The dimensional stability and color change of the UV cured fabrics measured by FAST and reflectance spectrophotometry showed significantly decreased color difference and increased percent extension compared with the samples pre-irradiated without agent application.

Development of Multi Piezo Ink-Jet Printing System Using Arbitrarily Waveform Generator (임의 전압파형발생기를 이용한 다중 피에조 잉크젯 3D 프린팅 장비 개발)

  • Kim, Jung Su;Kim, Dong Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.9
    • /
    • pp.781-786
    • /
    • 2015
  • Recently, studies of 3D printing methods have been working in various applications. For example, the powder base method laminates the prints by using a binding or laser sintering method. However, the draw back of this method is that the post process is time consuming and does not allow for parts to be rapidly manufactured. The binding method requires the post process while the time required for the post process is longer than the manufacturing time. This paper proposes a UV curing binding method with an integrated piezo printing head system. The optimization of an arbitrary waveform generation for the control of a UV curable resin droplet was researched, in addition to developed optimized UV curing processes in multi nozzle ink jet heads.

How does duration of curing affect the radiopacity of dental materials?

  • Bejeh Mir, Arash Poorsattar;Bejeh Mir, Morvarid Poorsattar
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.89-93
    • /
    • 2012
  • Purpose : Clinicians commonly encounter cases in which it is difficult to determine whether adjacent radiopacities are normal or pathologic. The ideal radiopacity of composite resin is equal to or higher than that of the same thickness of aluminum. We aimed to investigate the possible effects of different curing times on the post-24-hour radiopacity of composite resins on digital radiographs. Materials and Methods : One mm thick samples of Filtek P60 and Clearfil resin composites were prepared and cured with three regimens of continuous 400 mW/$cm^2$ irradiance for 10, 20 and 30 seconds. Along with a 12-step aluminum step wedge, digital radiographs were captured and the radiopacities were transformed to the equivalent aluminum thicknesses. Data were compared by a general linear model and repeated-measures of ANOVA. Results : Overall, the calculated equivalent aluminum thicknesses of composite resins were increased significantly by doubling and tripling the curing times (F(2,8)=8.94, p=0.002). Notably, Bonferroni post-hoc tests confirmed that the radiopacity of the cured Filtek P60 was significantly higher at 30 seconds compared with 10 seconds (p=0.04). Although the higher radiopacity was observed by increasing the time, other comparisons showed no statistical significance (p>0.05). Conclusion : These results supported the hypothesis that the radiopacity of resin composites might be related to the duration of light curing. In addition to the current standards for radiopacity of digital images, defining a standard protocol for curing of dental materials should be considered, and it is suggested that they should be added to the current requirements for dental material.

AN ACCELERATED TEST FOR COLOR STABILITY AND OPACITY CHANGE OF LIGHT CURING COMPOSITE RESINS (광중합 복합레진의 색안정성 및 투명도 변화에 관한 가속시험)

  • Hwang, Inn-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.215-226
    • /
    • 1993
  • Color stability of tooth colored restorative resins is an important factor, particularly in anterior teeth restoration. The purpose of this study was to evaluate the color stability and opacity change of several light curing composite resins. Specimens of eight composite resins(Prisma AP. H., Brilliant Enamel, Charisma, Durafil, Helio Progress, Herculite XR, P-50 and Silux Plus) were divided into two groups : In Group 1, the specimens were polymerized by visible light curing unit for 60 seconds on both sides and in Group 2, the post-cured specimens were heat tempered by light/heat curing unit for 45 units(about 18 min.). All specimens were stored in distilled water at $60^{\circ}C$ for 30 days. The color characteristics($L^*,a^*,b^*$) and opacity of the specimens before and after immersion were measured by spectrocolorimetry and the total color difference(${\Delta}E^*$) and opacity change (${\Delta}Y%$) were computed. The results obtained were as follows : 1. SP and APH in both groups, DF, HP and HXR in Group 1 showed ${\Delta}E^*$-value above 2.0. 2. DF, HP, SP and HXR in Group 1 showed higher ${\Delta}E^*$-value than in Group 2, but the others had no significant difference. 3. The opacity of CH and HXR in Group 1, and of CH and BE in Group 2 decreased after immersion, while that of the others increased. 4. Opacity change of BE, P50 and HXR was significantly different between Group 1 and 2. These results suggest that color change in the post-cure heat tempered specimens by light/heat curing unit was smaller than that of the specimens polymerized by visible light curing unit. No clinically detectable opacity changes were noted for any materials in either goup.

  • PDF