• Title/Summary/Keyword: positron

Search Result 696, Processing Time 0.036 seconds

Detection of Cancer with PET and PET/CT in Asymptomatic Volunteers (무증상 성인에서 PET과 PET/CT를 이용한 암 진단)

  • Chung, Ji-In;Cho, Han-Byoul;Shim, Jae-Yong;Choi, Joon-Young;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Yoon-Ho
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.526-534
    • /
    • 2009
  • Purpose: We retrospectively investigated the diagnostic performance of $^{18}F$-fluorodeoxyglucose positron emission tomography (PET) and PET/CT for cancer detection in asymptomatic health-check examinees. Materials and Methods: This study consisted of 5091 PET or PET/CT conducted as part of annual health examination at one hospital from March 1998 to February 2008. To find the incidence of cancers, medical records of the subjects were thoroughly reviewed for a follow-up period of one year. The patterns of formal readings of PET and PET/CT were analyzed to assess the sensitivity and specificity for cancer detection. The histopathology and stage of the cancers were evaluated in relation to the results of PET. Results: Eighty-six cancers (1.7%) were diagnosed within one year after PET or PET/CT. When PET and PET/CT results were combined, the sensitivity was 48.8% and specificity was 81.1% for cancer detection. PET only had a sensitivity of 46.2% and a specificity of 81.4%, and PET/CT only had a sensitivity of 75.0% and a specificity of 78.5% respectively. There were no significant differences in cancer site, stage and histopathology between PET positive and PET negative cancers. In 19.3% of formal readings of PET and PET/CT, further evaluation to exclude malignancy or significant disease was recommended. Head and neck area and upper gastrointestinal tract were commonly recommended sites for further evaluation. Conclusions: PET and PET/CT showed moderate performance for detecting cancers in asymptomatic adults in this study. More experience and further investigation are needed to overcome limitations of PET and PET/CT for cancer screening.

Different $^{18}$F-FDG Uptake According to Tumor location and Morphology of Cholangiocarcinoma and Its Clinical Implication (담관암의 위치와 형태에 따른 $^{18}$F-FDG 섭취량의 차이와 임상적 의의)

  • Lee, Won-Seok;Lee, Yoon-Jae;Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.317-322
    • /
    • 2009
  • Purpose: $^{18}$F-flurodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of $^{18}$F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. Materials and Methods: From April 2005 to May 2008, eighty two patients (M:F = 55:27, age 66.2$\pm$9.6 yrs) with CC underwent $^{18}$F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV$_{max}$) was obtained from the primary tumor. The difference of SUV$_{max}$ according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Results: Overall sensitivity of PET scan was 81.7% in CC. SUV$_{max}$ on PET scan in intrahepatic CC was significantly higher compared to extrahepatic CC. In extrahepatic CC, polypoid type showed significantly higher SUV$_{max}$ compared to scirrhous type. Conclusion: $^{18}$F-FDG PET may have a significant impact on clinical decision-making and on the management of intrahepatic cholangiocarcinoma. And it is related to the shape of the tumor and the sensitivity of detection is higher in the mass-forming type than in the scirrhous type.

Synthesis of Cyclen-Based Copper Complexes as a Potential Estrogen Receptor Ligand (에스트로젠 수용체 리간드로서 사이클렌을 기본 구조로 한 구리 착물의 합성)

  • Park, Jeong-Chan;Pandya, Darpan N.;Jeon, Hak-Rim;Lee, Sang-Woo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Yoo, Jeong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.326-334
    • /
    • 2007
  • Purpose: The estrogen receptor (ER), which is over-expressed in ER-positive breast tumors, has been imaged by positron emission tomography (PET) using $[^{18}F]$ labeled estrogen ligands, especially $[^{18}F]FES$. However, $[^{18}F]$ has relatively short-lived half-life ($t_{1/2}$ =1.8 h) and the labeling yield of radio-fluorination is usually low compared with $^{64}Cu\;(t_{1/2}=12.7\;h)$. 1,4,7,10-tetraazacyclododecane (cyclen) is used to form stable metal complexes with copper, indium, gallium, and gadolinium. With these in mind, we prepared cyclen-based Cu complexes which mimic estradiol in aspect of two hydroxyl groups. Materials and Methods: 1.7-Protected cyclen, 1.7-bis (benzyloxycarbonyl)-cyclen was synthesized according to the reported procedure. After introducing two 4-benzyloxybenzyl groups at 4,10-positions, the benzyloxycarbonyl and benzyl groups were removed at the same time by hydrogenation on Pd/C to give 1,7-bis(4-hydroxybenzyl)-1,4,7,10-tetraazacyclododecane (1). Results: The prepared ligand 1 was fully characterized by $^1H,\;^{13}C$ NMR, and mass spectrometer. The synthesized ligand was reacted with copper chloride and copper perchlorate to give copper complexes $[Cu(1)]^{2+}2(CIO_4^-)\;and\;[Cu(1)Cl]^+Cl^-$ which were confirmed by high-resolution mass (FAB). Conclusion: We successfully synthesized a cyclen derivative of which two phenol groups are located on trans position of N-atoms. And, two Cu(ll) complexes of +2 and +1 overall charge, were prepared as a potential PET tracers for ER imaging.

Evaluation of Neoadjuvant Chemotherapy Effect in Osteosarcoma (골육종에서 술전 항암화학요법의 효과 판정)

  • Joo, Min Wook;Kang, Yong-Koo;Yoo, Ie Ryung;Choi, Woo Hee;Chung, Yang-Guk;Kim, Dong-Hyun;Kang, Jin-Woo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.20 no.2
    • /
    • pp.66-73
    • /
    • 2014
  • Purpose: Various diagnostic imaging modalities have been used to evaluate the effect of neoadjuvant chemotherapy for osteosarcoma early and noninvasively. We evaluated the effectiveness of imaging studies of plain radiographs and positron-emission tomography/computed tomography (PET/CT) in predicting neoadjuvant chemotherapy effect for osteosarcoma and tried to establish a general principle in interpretation of PET/CT parameters. Materials and Methods: Eighteen patients who underwent two cycles of neoadjuvant chemotherapy and surgical excision for osteosarcoma were enrolled. There were 13 males and 5 females, with a median age of 19 (11-63) years. Fifteen patients of 18 had the American Joint Committe on Cancer (AJCC) stage IIB. They had plain radiographs and PET/CT before and after neoadjuvant chemotherapy. The resected tumor specimens were pathologically examined to determine histological response grade using a conventional mapping method. Statistical analysis was performed to evaluate the correlation between histopathological necrosis rate, and radiographic finding category, post-chemotherapy maximum standardized uptake value (SUVmax), average standardized uptake value and metabolic tumor volume (MTV) as well as reduction rates of them. Results: Eight patients were good responders to neoadjuvant chemotherapy based on histological evaluation. Median SUVmax reduction rate was 73 (23-77) % in good responders and 42 (-32-76) % in poor responders. Median MTV reduction rate was 93.5 (62-99) % in good responders and 46 (-81-100) % in poor responders. While radiographic finding category was not different according to histological response (p=1.0), SUVmax reduction rate was significantly different (p=0.041). Difference in MTV reduction rates approached statistical significance as well (p=0.071). Conclusion: While radiographic finding category was not reliable to assess neoadjuvant chemotherapy effect for osteosarcoma, reduction rate of SUVmax was a useful indicator in this study. As parameters of PET/CT can be influenced by various factors of settings, different centers have to make an effort to establish their own standard of judgement with reference of previous studies.

Differentiation of Medial or Lateral Temporal Lobe Epilepsy by F-18-Fluorodeoxyglucose Positron Emission Tomography: Comparative Study with Magnetic Resonance Imaging in 113 Surgically and Pathologically Proven Patients (F-18-Fluorodeoxyglucose 양전자단층촬영을 이용한 내외측 측두엽간질의 감별: 수술과 병리 소견으로 확진한 113예에서 자기공명영상과 비교 분석)

  • Lee, Dong-Soo;Lee, Sang-Kun;Chang, Ki-Hyun;Chung, Chun-Kee;Choi, Ki-Young;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.111-119
    • /
    • 1999
  • Purpose: As mesial temporal lobe epilepsy (TLE) shows hypometabolism of medial and lateral temporal lobe, we investigated whether symmetric uptake of F-18-FDG in medial temporal lobes can differentiate mesial from lateral TLE. Materials and Methods: In 113 patients (83 mesial TLE, 30 lateral TLE) who underwent anterior temporal lobectomy and/or corticectomy with good surgical outcome, we performed F-18-FDG PET and compared F-18-FDG uptake of medial and lateral temporal lobes. All the patients with mesial TLE had hippocampal sclerosis except one congenital abnormal hippocampus. Patients with lateral TLE revealed cerebromalacia, microdysgenesis, arteriovenous malformation, old contusion, and cortical dysplasia. Results: Sensitivity of F-18-FDG PET and MR for mesial TLE was 84% (70/83) and 73% (61/83), respectively. Sensitivity of F-18-FDG PET and MR for lateral TLE was 90% (27/30) and 66% (20/30), respectively. Twelve patients were normal on F-18-FDG PET. 101 patients had hypometabotism of lateral temporal lobe. Among 88 patients who showed hypometabolism of medial temporal lobe as well as lateral temporal lobe, 70 were mesial TLE patients and 18 were lateral TLE on pathologic examination. Positive predictive value of medial temporal hypometabolism for mesial TLE was 80%. Among 13 patients who showed hypometabolism of only lateral temporal lobe, 4 were mesial TLE and 9 were lateral TLE. Positive predictive value of hypometabolism of lateral temporal lobe for the diagnosis of lateral TLE was 69% (9/13). Normal MR findings stood against medial TLE, whose negative predictive value was 66%. Conclusion: Lateral temporal lobe epilepsy should be suspected when there is decreased F-18-FDG uptake in lateral temporal lobe with normal uptake in medial temporal lobe.

  • PDF

Assessment of Attenuation Correction Techniques with a $^{137}Cs$ Point Source ($^{137}Cs$ 점선원을 이용한 감쇠 보정기법들의 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyoung;Park, Yun-Young;Park, Hae-Joung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.57-68
    • /
    • 2005
  • Purpose: The objective of this study was to assess attenuation correction algorithms with the $^{137}Cs$ point source for the brain positron omission tomography (PET) imaging process. Materials & Methods: Four different types of phantoms were used in this study for testing various types of the attenuation correction techniques. Transmission data of a $^{137}Cs$ point source were acquired after infusing the emission source into phantoms and then the emission data were subsequently acquired in 3D acquisition mode. Scatter corrections were performed with a background tail-fitting algorithm. Emission data were then reconstructed using iterative reconstruction method with a measured (MAC), elliptical (ELAC), segmented (SAC) and remapping (RAC) attenuation correction, respectively. Reconstructed images were then both qualitatively and quantitatively assessed. In addition, reconstructed images of a normal subject were assessed by nuclear medicine physicians. Subtracted images were also compared. Results: ELEC, SAC, and RAC provided a uniform phantom image with less noise for a cylindrical phantom. In contrast, a decrease in intensity at the central portion of the attenuation map was noticed at the result of the MAC. Reconstructed images of Jaszack and Hoffan phantoms presented better quality with RAC and SAC. The attenuation of a skull on images of the normal subject was clearly noticed and the attenuation correction without considering the attenuation of the skull resulted in artificial defects on images of the brain. Conclusion: the complicated and improved attenuation correction methods were needed to obtain the better accuracy of the quantitative brain PET images.

The Usefulness of 18F-FDG PET to Differentiate Subtypes of Dementia: The Systematic Review and Meta-Analysis

  • Seunghee Na;Dong Woo Kang;Geon Ha Kim;Ko Woon Kim;Yeshin Kim;Hee-Jin Kim;Kee Hyung Park;Young Ho Park;Gihwan Byeon;Jeewon Suh;Joon Hyun Shin;YongSoo Shim;YoungSoon Yang;Yoo Hyun Um;Seong-il Oh;Sheng-Min Wang;Bora Yoon;Hai-Jeon Yoon;Sun Min Lee;Juyoun Lee;Jin San Lee;Hak Young Rhee;Jae-Sung Lim;Young Hee Jung;Juhee Chin;Yun Jeong Hong;Hyemin Jang;Hongyoon Choi;Miyoung Choi;Jae-Won Jang;Korean Dementia Association
    • Dementia and Neurocognitive Disorders
    • /
    • v.23 no.1
    • /
    • pp.54-66
    • /
    • 2024
  • Background and Purpose: Dementia subtypes, including Alzheimer's dementia (AD), dementia with Lewy bodies (DLB), and frontotemporal dementia (FTD), pose diagnostic challenges. This review examines the effectiveness of 18F-Fluorodeoxyglucose Positron Emission Tomography (18F-FDG PET) in differentiating these subtypes for precise treatment and management. Methods: A systematic review following Preferred Reporting Items for Systematic reviews and Meta-Analyses guidelines was conducted using databases like PubMed and Embase to identify studies on the diagnostic utility of 18F-FDG PET in dementia. The search included studies up to November 16, 2022, focusing on peer-reviewed journals and applying the goldstandard clinical diagnosis for dementia subtypes. Results: From 12,815 articles, 14 were selected for final analysis. For AD versus FTD, the sensitivity was 0.96 (95% confidence interval [CI], 0.88-0.98) and specificity was 0.84 (95% CI, 0.70-0.92). In the case of AD versus DLB, 18F-FDG PET showed a sensitivity of 0.93 (95% CI 0.88-0.98) and specificity of 0.92 (95% CI, 0.70-0.92). Lastly, when differentiating AD from non-AD dementias, the sensitivity was 0.86 (95% CI, 0.80-0.91) and the specificity was 0.88 (95% CI, 0.80-0.91). The studies mostly used case-control designs with visual and quantitative assessments. Conclusions: 18F-FDG PET exhibits high sensitivity and specificity in differentiating dementia subtypes, particularly AD, FTD, and DLB. This method, while not a standalone diagnostic tool, significantly enhances diagnostic accuracy in uncertain cases, complementing clinical assessments and structural imaging.

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

The Role of Camera-Based Coincidence Positron Emission Tomography in Nodal Staging of Non-Small Cell Lung Cancer (비소세포폐암의 림프절 병기 결정에서 Coincidence PET의 역할)

  • Lee, Sun-Min;Choi, Young-Hwa;Oh, Yoon-Jung;Cheong, Seong-Cheoll;Park, Kwang-Joo;Hwang, Sung-Chul;Lee, Yi-Hyeong;Park, Chan-H;Hahn, Myung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.642-649
    • /
    • 1999
  • Background: It is very important to determine an accurate staging of the non-small cell lung cancer(NSCLC) for an assessment of operability and it's prognosis. However, it is difficult to evaluate tumor involvement of mediastinal lymph nodes accurately utilizing noninvasive imaging modalities. PET is one of the sensitive and specific imaging modality. Unfortunately PET is limited use because of prohibitive cost involved with it's operation. Recently hybrid SPECT/PET(single photon emission computed tomography/positron emission tomography) camera based PET imaging was introduced with relatively low cost. We evaluated the usefulness of coincidence detection(CoDe) PET in the detection of metastasis to the mediastinal lymph nodes in patients with NSCLC. Methods: Twenty one patients with NSCLC were evaluated by CT or MRI and they were considered operable. CoDe PET was performed in all 21 patients prior to surgery. Tomographic slices of axial, coronal and sagittal planes were visually analysed. At surgery, mediastinal lymph nodes were removed and histological diagnosis was performed. CoDe PET findings were correlated with histological findings. Results: Twenty of 21 primary tumor masses were detected by the CoDe PET. Thirteen of 21 patients was correctly diagnosed mediastinal lymph node metastasis by the CoDe PET. Pathological N0 was 14 cases and the specificity of N0 of CoDe PET was 64.3%. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of N1 node was 83.3%, 73.3%, 55.6%, 91.7%, and 76.2% respectively. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of N2 node was 60.0%, 87.5%, 60.0%,87.5%, and 90.0% respectively. There were 3 false negative cases but the size of the 3 nodes were less than 1cm. The size of true positive nodes were 1.1cm, 1.0cm, 0.5cm respectively. There were 1 false positive among the 12 lymph nodes which were larger than 1cm. False positive cases consisted of 1 tuberculosis case, 1 pneumoconiosis case and 1 anthracosis case. Conclusion: CoDe PET has relatively high negative predictive value in the enlarged lymph node in staging of mediastinal nodes in patients with NSCLC. Therefore CoDe PET is useful in ruling out metastasis of enlarged N3 nodes. However, further study is needed including more number of patients in the future.

  • PDF