• Title/Summary/Keyword: position measurement

Search Result 2,282, Processing Time 0.042 seconds

Study on Robot Calibration Using Multi-measurement Coordinate System (다중 측정 좌표계를 이용한 로봇 캘리브레이션 방법 연구)

  • Lim, Saeng-Ki;Kim, Jung-Tae;Borm, Jin-Hwan;Choi, Jae-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.164-173
    • /
    • 1999
  • Robot calibration needs accurate measurements of robot end-effector position at a number of different robot configurations. One of the efficient ways of the measurement is "Touching on Jig" method suggested in [7], which utilizes a touch sensor and a fixture consisting of various sizes of blocks. By moving the end-effector to touch the surface of a block whose position relative to the other is known, the end-effector position relative to the fixture coordinate system can be obtained at the instant of touching. However, the global size of fixture is too small to cover the various configurations of the robot. Because of the manufacturing difficulties, the fixture cannot be manufactured large enough for well distributed position measurement. It results in the improvement of robot accuracy only in the limited space near to the fixture rather than over the whole space of the robot working volume. The paper proposes a method to resolve the above problem by measuring the end-effector positions with respect to several different coordinate system using the same measurement devices. It is found that the proposed method leads the improvements of robot position accuracy over the large space of working volume. The experimental studies are performed to show the validity of the method and their results are discussed.

  • PDF

Enhancement of Tracking Performance of Laser Tracking System for Measuring Position Accuracy of Robots

  • Hwang, Sung-Ho;Choi, Gyeong-Rak;Lee, Ho-Gil;Shon, Woong-Hee;Kim, Jin-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.61.5-61
    • /
    • 2001
  • The laser tracking system(LTS) presents the most promising technique for dynamic position measurement of industrial robots. This system combine the advantage of high accuracy with a contactless measurement technique. It is the measurement system of position in three dimensions using distance data obtained by laser interferometer and real time angle by tracking mirror assembly. After measuring the tracking error of the beam projected on the center of retroreflector in robot end effector, this system tracks the end effector continuously by adjusting tracking mirror angle to minimize this error ...

  • PDF

Design and Implementation of an Absolute Position Sensor Based on Laser Speckle with Reduced Database

  • Tak, Yoon-Oh;Bandoy, Joseph Vermont B.;Eom, Joo Beom;Kwon, Hyuk-Sang
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.362-369
    • /
    • 2021
  • Absolute position sensors are widely used in machine tools and precision measuring instruments because measurement errors are not accumulated, and position measurements can be performed without initialization. The laser speckle-based absolute position sensor, in particular, has advantages in terms of simple system configuration and high measurement accuracy. Unlike traditional absolute position sensors, it does not require an expensive physical length scale; instead, it uses a laser speckle image database to measure a moving surface position. However, there is a problem that a huge database is required to store information in all positions on the surface. Conversely, reducing the size of the database also decreases the accuracy of position measurements. Therefore, in this paper, we propose a new method to measure the surface position with high precision while reducing the size of the database. We use image stitching and approximation methods to reduce database size and speed up measurements. The absolute position error of the proposed method was about 0.27 ± 0.18 ㎛, and the average measurement time was 25 ms.

ZOOMING FUNCTIONAL METHOD FOR POSITION MEASUREMENT IN ENCLOSING SIGNAL FIELD BASED N CONCEPT OF PROGRESSIVE LEARNING MEASUREMENT SYSTEM

  • Ohyama, Shinji;Cao, Li;Kobayashi, Akira
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1318-1321
    • /
    • 1997
  • A method for two-dimensional position measurement using an enclosing field has been studied and reported. The feature of this mehtod is zooming functional measurement by operating both the initial phase shift and the brightness ratio of the lighting function. An experimental system was developed and the experimental results on zooming effects are shown in this paper. This system is also an example of a "progressive learning measurement system".tem".uot;.

  • PDF

A Study on Observability of Model Parameters for Robot Calibration (로봇 캘리브레이션을 위한 모델 파라미터의 관측성 연구)

  • 범진환;양수상;임생기
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.4
    • /
    • pp.64-71
    • /
    • 1997
  • Objective of calibration is to find out the accurate kinematic relationships between robot joint angles and the position of the end-effector by estimating accurate model parameters defining the kinematic function. Estimating the model parameters requires measurement of the end-effector position at a number of different robot configurations. This paper studies the implication of measurement configurations in robot calibration. For selecting appropriate measurement configurations in robot calibration, an index is defined to measure the observability of the model parameters with respect to a set of robot configurations. It is found that, as the observability index of the selected measurement configurations increase the attribution of the position errors to the parameter errors becomes dominant while the effects of the measurement and unmodeled errors are less significant; consequently better estimation of parameter errors is expected. To demonstrate the implication of the observability measure in robot calibration, computer simulations are performed and their results are discussed.

  • PDF

Signal Analysis According to the Position of the ECG Sensor Electrode in Healthcare Backpack (헬스케어 가방의 ECG 센서 전극 위치에 따른 신호 분석)

  • Lee, Hyeon-Seok;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.402-408
    • /
    • 2014
  • Heart rate is one of the most important signal to monitor the health condition of the patient or exerciser. Various wearable devices have been developed for the continuous monitoring of ECG signal from human body during exercise. Among these, ECG chest belt has been widely used. However wearing chest belt with ECG sensor is uncomfortable in normal life due to the electrode contact between metal electrodes of ECG sensor and skin of the human body. So we develop the royal healthcare backpack that can measure ECG signal without skin contact by using capacitor-type ECG sensor. The position of the measurement point is critical to collect a clear ECG signal in the capacitive ECG measurement from backpack. Various tests were conducted to find the optimal ECG measurement position which has less noise and could get strong and clear ECG signal during exercise, walking, hiking, mountain climbing and cycling.

Precision Displacement Measurement of Three-DOF Micro Motions Using Position Sensitive Detector and Spherical Reflector (PSD와 구면반사를 이용한 3자유도 미소 변위의 정밀측정)

  • 이재욱;조남규
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.7
    • /
    • pp.99-104
    • /
    • 2003
  • A precision displacement measurement system of 3-DOF micro motions is proposed in this paper. The measurement system is composed of two diode lasers, two quadratic PSDs, two beam splitters and a sphere whose surface is highly reflective. In this measurement system, the sphere reflector is mounted on the platform of positioning devices whose 3-DOF translational motions are to be measured, and the sensitive areas of two PSDs are oriented toward the center point of the sphere reflector. Each laser beam emitted from two diode laser sources is reflected at the surface of sphere and arrives at two PSDs. Each PSD serves as a 2-dimensional sensor, providing the information on the 3-dimensional position of the sphere. In this paper, we model the relationship between the outputs of two PSDs and 3-DOF translational motions of the sphere mounted on the object. Based on a deduced measurement model, we perform measurement simulation and evaluate the performance of the proposed measurement system: linearity, sensitivity, and measurement error. The simulation results show that the proposed measurement system can be valid means of precision displacement measurement of 3-dimensional micro motions.

Comparison of the capsular width measured on ultrasonogrape and MR image of the temporomandibular joint (측두하악관절의 초음파영상과 자기공명영상에서 하악과두 외측면과 관절낭간 거리 측정치 비교)

  • Lee Tae-Wan;Yoo Dong-Soo;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.41-48
    • /
    • 2006
  • Purpose : To evaluate the reliability and clinical usefulness of ultrasonography in the temporomandibular joint (TMJ). Materials and Methods : Parasagittal and paracoronal 1.5 T MR images and 7.5 MHz ultrasonographs of 40 TMJs in 20 asymptomatic volunteers were obtained. Disc position using MR imaging was evaluated and the distance between the lateral surface of mandibular condyle and the articular capsule using MR image and ultrasonograph of 27 TMJs with normal disc position was measured and compared. Intraobserver and interobserver measurements reliability was evaluated by using interclass correlation coefficients (ICC) and measurement error. Also, the distance measured on ultrasonographs was compared, according to mouth position and disc postion. Results : The normal disc position was found in 27 of 40 asymptomatic joints. At the intraobserver reliability of measurement, ICC at the closed and open mouth position were 0.89 and 0.91. The measurement error was 0.4% and 0.5%. At the interobserver reliability, ICC at the closed and open mouth position were 0.92 and 0.81. The measurement error was 0.4% and 0.7%. At the TMJ with normal disc position, the distances between the lateral surface of mandibular condyle and the articular capsule measured on MR images and ultrasonographs were $2.0{\pm}0.7mm,\;1.8{\pm}0.5mm$, respectively (p<0.05). On the ultrasonographs, the distances at open mouth position were $1.2{\pm}0.5mm$ (p<0.05). At the TMJ with medially displaced disc, the distances at the closed and open mouth position were $1.3{\pm}0.3\;mm\;and\;0.9{\pm}0.2\;mm$ (p<0.05). Conclusion : The results suggest ultrasonography of TMJ is a reliable imaging technique for assessment of normal disc position.

  • PDF

A Laser Vision System for the High-Speed Measurement of Hole Positions (홀위치 측정을 위한 레이져비젼 시스템 개발)

  • Ro, Young-Shick;Suh, Young-Soo;Choi, Won-Tai
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.333-335
    • /
    • 2006
  • In this page, we developed the inspection system for automobile parts using the laser vision sensor. Laser vision sensor has gotten 2 dimensions information and third dimension information of laser vision camera using the vision camera. Used JIG and ROBOT for inspection position transfer. Also, computer integration system developed that control system component pal1s and manage data measurement information. Compare sensor measurement result with CAD Data and verified measurement result effectiveness taking advantage of CAD to get information of measurement object.

  • PDF