• Title/Summary/Keyword: position matching

Search Result 471, Processing Time 0.024 seconds

Deep Learning based Vehicle AR Manual for Improving User Experience (사용자 경험 향상을 위한 딥러닝 기반 차량용 AR 매뉴얼)

  • Lee, Jeong-Min;Kim, Jun-Hak;Seok, Jung-Won;Park, Jinho
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.3
    • /
    • pp.125-134
    • /
    • 2022
  • This paper implements an AR manual for a vehicle that can be used even in the vehicle interior space where it is difficult to apply the augmentation method of AR content, which is mainly used, and applies a deep learning model to improve the augmentation matching between real space and virtual objects. Through deep learning, the logo of the steering wheel is recognized regardless of the position, angle, and inclination, and 3D interior space coordinates are generated based on this, and the virtual button is precisely augmented on the actual vehicle parts. Based on the same learning model, the function to recognize the main warning light symbols of the vehicle is also implemented to increase the functionality and usability as an AR manual for vehicles.

Markerless camera pose estimation framework utilizing construction material with standardized specification

  • Harim Kim;Heejae Ahn;Sebeen Yoon;Taehoon Kim;Thomas H.-K. Kang;Young K. Ju;Minju Kim;Hunhee Cho
    • Computers and Concrete
    • /
    • v.33 no.5
    • /
    • pp.535-544
    • /
    • 2024
  • In the rapidly advancing landscape of computer vision (CV) technology, there is a burgeoning interest in its integration with the construction industry. Camera calibration is the process of deriving intrinsic and extrinsic parameters that affect when the coordinates of the 3D real world are projected onto the 2D plane, where the intrinsic parameters are internal factors of the camera, and extrinsic parameters are external factors such as the position and rotation of the camera. Camera pose estimation or extrinsic calibration, which estimates extrinsic parameters, is essential information for CV application at construction since it can be used for indoor navigation of construction robots and field monitoring by restoring depth information. Traditionally, camera pose estimation methods for cameras relied on target objects such as markers or patterns. However, these methods, which are marker- or pattern-based, are often time-consuming due to the requirement of installing a target object for estimation. As a solution to this challenge, this study introduces a novel framework that facilitates camera pose estimation using standardized materials found commonly in construction sites, such as concrete forms. The proposed framework obtains 3D real-world coordinates by referring to construction materials with certain specifications, extracts the 2D coordinates of the corresponding image plane through keypoint detection, and derives the camera's coordinate through the perspective-n-point (PnP) method which derives the extrinsic parameters by matching 3D and 2D coordinate pairs. This framework presents a substantial advancement as it streamlines the extrinsic calibration process, thereby potentially enhancing the efficiency of CV technology application and data collection at construction sites. This approach holds promise for expediting and optimizing various construction-related tasks by automating and simplifying the calibration procedure.

Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device (방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발)

  • Dong-Sik Jin;Kyeong-Ryeong Kim;Jae-Geun Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

Comparison of Image Uniformity Due to Position Shifting in COR on Myocardial SPECT (Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교)

  • Lim, Hyun-Jin;Kim, Joong-Hyun;Kim, Jae-Il;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.70-75
    • /
    • 2012
  • Purpose: It is important to acquire accurate data because the SPECT scan affected by various physical factors. The aim of this study was to compare the uniformity when both centers were matched or mismatched differed from position of heart in COR. Materials and methods: The images were acquired with cylindrical uniform phantom (6.7 cm diameter, 9 cm length) and heart insert phantom using Cardio MD SPECT system (Philips, USA). The phantoms were positioned on COR as well as four different points which were 10 cm above, below, left and right side from the COR. The counts from the both edge of cylindrical uniform phantom and those from the both wall of heart insert phantom were compared by using vertical and horizontal line profile. In addition, the qualitative evaluation was performed with heart insert phantom images and volunteer test. Results: In heart insert phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 1.1, 4.1, 4.9, 2.2 and 0.9% using T-A curve for horizontal view. In case of vertical view of COR 3.9, 21.9, 3.5, 23.9, 14.0% were shown. In cylindrical phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 4.3, 0.3, 3.3, 2.6 and 0.7% using T-A curve for horizontal view. In case of vertical view of COR 2.7, 3.0, 1.0, 0.3, 3.4% were shown. For qualitative evaluation, the images at COR were the most uniform for both of heart insert phantom and volunteer test, whereas other four positions showed somewhat distorted images. Conclusion: It showed the most uniform images when COR is matched with the heart. Therefore, we can expect that distortion which increased or decreased of myocardial perfusion will be prevented by matching the heart and COR when positioning. Furthermore, the accuracy of diagnosis will be improved as well.

  • PDF

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

A Study to Classify the Type of Retirement Process among the Mature-aged in Korea - Focusing on Diversity and Inequality - (우리나라 중고령자의 은퇴과정 유형화 연구 - 다양성과 불평등 중심으로 -)

  • Park, Kyung-Ha
    • Korean Journal of Social Welfare Studies
    • /
    • v.42 no.3
    • /
    • pp.291-327
    • /
    • 2011
  • The purpose of this study is to classify the type of retirement process among the mature-aged in Korea. The study used the panel data from Korean Labor Panel (year2~6) for the classification of retirement process through Optimal Matching and Cluster Analysis. Classification is made in 5 categories as 'peripheral-economically active', 'private-transfer dependent', 're-entering limited', 'securely exiting', 'exit-and-reentering'. First, "peripheral-economically active" is a group which frequently experienced job status change and work insecurity. Second, "private-transfer dependent" is a group in which private transfer is likely to be supplements income in the incidence of unemployment. Third, "re-entering limited" is a group in which the proportion of no financial support combined with the absence of any economic activity is the largest. Fourth, the type "Securely exit" is th group whose members switches over to non-economically active status with pension receipt. The last type is "exit-and-reenter" that the member are highly possible to reenter in the labor market and stay in long time regardless of with or without pension plan. To examine the inequality among the types of retirement process, the duration of each status is analyzed. First, in the situation of being non-economically active, the duration of status is maintain public pension receiving and duration stabile in "securely exit" group. For "private-transfer dependent" type, members are mostly dependent on private financial support and that duration of it is longest. Through the analysis of retirement process without under other financial supports, it is "securely-exiting" type for which the duration of full-time employment is longest. It appears that the duration of part-time employment is longest in "peripheral-economically active" type. And for the case of non-waged employment it is "exit-and-reenter" type. Finally, the redistribution policy based on life course perspective is necessary to prevent that the opportunity in the structure before retirement stage and the unfavorable position in labor market make worse disadvantage in retirement process and after that.

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

A study on Perfume case (향(香) 집에 관한연구)

  • 이선재
    • Journal of the Korean Society of Costume
    • /
    • v.33
    • /
    • pp.117-142
    • /
    • 1997
  • This study is on perfume case that is one of a great number of ornaments which was designed by out ancestors. We had developed the tradition and the history of perfume case bag fan-weight etc. These have the same function as the present perfume. case. There were basket-shaped perfume cases which were the smellest one among the personal girdle ornaments in the silla era. The various patterned perfume case were made of gold metal coral platinum or green jadeite etc. In the single-crop trinkets a embroidered perfume bag with the gold and silver thread whose forms perfectly match their functions appeared during the Yi Dynasty. There was also a perfume bag which was one of the daily necessities. A precious "jul perfume" was carried by noble women. A fan-weight perfume bag was attached to the fan to emphasize the intrinsic beauty of utility and function. It is necessary to know the function of prefume case. As perfume case is weared on the clothes it was given more decorative effects as well as the function of medicinal amulet with a sweet smell. Therefore it is very important for us to study perfume case that has various function as an ornament. So The purpose of this study is to investigate the practical and decorative side of perfume case with the general examines of perfume finding how to practice use through our life. The results were as follows; 1. The first use of perfume is perfume through smoke which is for ceremony of religion It removes human body odor by degrees and spreads a sweet odor. Also the materials for making perfume of early age is aromatic plants which will be used flour-made flowers stems. As the materials for making perfume use is increasing today we can invent alcohol perfume today 2. Our country the custom of perfume-used is wide. Among them men's perfume-used was very special phenomenon. For example men were wearing perfume bag in the Silla era. Because perfume represented wealth and noble in those days. They shew off social position personality through perfume-used. 3. One of early religion ceremony article there was the perfume. And perfume case was means for containing perfume. Gradually the perfume case was used widly as increasing needs of perfume in human life. 4. In the middle period of 'Koryo' Dynasty perfume cases had a close relationship with clothes but after Mongolian has been attacked 'Koryo' there were changes in wearing clothes therefore the position of perfume cases were transfered to coat string that was the origin of decoration style that they began. That is to say the perfume case has been influenced the position of perfume case shapes with changing of fashion. 5. The perfume case has been made manifest various function as an ornament. In the practical side First medical-perfume in perfume case has been played an important role in first-aid medicine in critical condition. Second it was amulet for self protection. That is the shape pattern color materials perfume of the perfume case was represented the amuletive nature. Third it was used as substitute article of perfume. Modern women use liquid-perfume as our ancestors used perfume case bag or jul perfume As started above. Also In the decorative side the perfume case has a beautiful formative arts by itself as well as a close relationship with clothes. That well as a close relationship with clothes. That is when the perfume case is worn on the clothes costume is showed aesthetices. That is the materials shapes color pattern of the perfume case we can see the visual beauty also the materials colors embroidered pattern knots tassel that are used the perfume case are increased the decorative beauty of costume. Sixth the symbol in pattern of the pattern case is shown ancetor's wealth and rank health longevity immortality many-born-boy in those days. Today the perfume case is not used with changing of costume by degrees, Accordingly I hope that the result of this study is an influened in devlopment of the perfume case design with matching the modern fashion.

  • PDF

Relationship between Brand Personality and the Personality of Consumers, and its Application to Corporate Branding Strategy

  • Kim, Young-Ei;Lee, Jung-Wan;Lee, Yong-Ki
    • Journal of Global Scholars of Marketing Science
    • /
    • v.18 no.3
    • /
    • pp.27-57
    • /
    • 2008
  • Many consumers enjoy the challenge of purchasing a brand that matches well with their own values and personalities (for example, Ko et al., 2008; Ko et al., 2006). Therefore, the personalities of consumers can impact on the final selection of a brand and its brand personality in two ways: first, the consumers may incline to purchase a brand or a product that reflects their own personalities; second, consumers tend to choose a company that has similar brand personalities to those brands that are being promoted. Therefore, the objectives of this study are following: 1. Is there any empirical relationship between a consumer's personality and the personality of a brand that he or she chooses? 2. Can a corporate brand be differentiated by the brand personality? In short, consumers are more likely to hold favorable attitudes towards those brands that match their own personality and will most probably purchase those brands matching well with their personality. For example, Matzler et al. (2006) found that extraversion and openness were positively related to hedonic product value; and that the personality traits directly (openness) and indirectly (extraversion, via hedonic value) influenced brand effects, which in turn droved attitudinal and purchase loyalty. Based on the above discussion, the following hypotheses are proposed: Hypothesis 1: the personality of a consumer is related to the brand personality of a product/corporate that he/she purchases. Kuksov (2007) and Wernerfelt (1990) argued that brands as a symbolic language allowed consumers to communicate their types to each other and postulated that consumers had a certain value of communicating their types to each other. Therefore, how brand meanings are established, and how a firm communicate with consumers about the meanings of the brand are interesting topics for research (for example, Escalas and Bettman, 2005; McCracken, 1989; Moon, 2007). Hence, the following hypothesis is proposed: Hypothesis 2: A corporate brand identity is differentiated by the brand personality. And there are significant differences among companies. A questionnaire was developed for collecting empirical measures of the Big-Five personality traits and brand personality variables. A survey was conducted to the online access panel members through the Internet during December 2007 in Korea. In total, 500 respondents completed the questionnaire, and considered as useable. Personality constructs were measured using the Five-factor Inventory (NEO-FFI) scale and a total of 30 items were actually utilized. Brand personality was measured using the five-dimension scale developed by Aaker (1997). A total of 17 items were actually utilized. The seven-point Likert-type scale was the format of responses, for example, from 1 indicating strongly disagreed to 7 for strongly agreed. The Analysis of Moment Structures (AMOS) was used for an empirical testing of the model, and the Maximum Likelihood Estimation (MLE) was applied to estimate numerical values for the components in the model. To diagnose the presence of distribution problems in the data and to gauge their effects on the parameter estimates, bootstapping method was used. The results of the hypothesis-1 test empirically show that there exit certain causality relationship between a consumer's personality and the brand personality of the consumer's choice. Thus, the consumer's personality has an impact on consumer's final selection of a brand that has a brand personality matches well with their own personalities. In other words, the consumers are inclined to purchase a brand that reflects their own personalities and tend to choose a company that has similar brand personalities to those of the brand being promoted. The results of this study further suggest that certain dimensions of the brand personality cause consumers to have preference to certain (corporate) brands. For example, the conscientiousness, neuroticism, and extraversion of the consumer personality have positively related to a selection of "ruggedness" characteristics of the brand personality. Consumers who possess that personality dimension seek for matching with certain brand personality dimensions. Results of the hypothesis-2 test show that the average "ruggedness" attributes of the brand personality differ significantly among Korean automobile manufacturers. However, the result of ANOVA also indicates that there are no significant differences in the mean values among manufacturers for the "sophistication," "excitement," "competence" and "sincerity" attributes of the corporate brand personality. The tight link between what a firm is and its corporate brand means that there is far less room for marketing communications than there is with products and brands. Consequently, successful corporate brand strategies must position the organization within the boundaries of what is acceptable, while at the same time differentiating the organization from its competitors.

  • PDF

A Study of the Adjustment and Treatment Depending on the Change of Prostate Location Using DIPS in Proton Beam Therapy for Prostate Gland in which a Fiducial Gold Marker was Inserted (Fiducial Gold Marker가 삽입된 전립선암 양성자 치료 시 Digital Image Positioning System (DIPS)을 이용한 전립선의 위치변화에 따른 보정에 관한 연구)

  • Park, June-Ki;Kim, Sun-Young;Kim, Tae-Yoon;Choi, Kye-Sook;Yeom, Doo-Suk;Kang, Dong-Yoon;Choi, Seung-O;Park, Ji-Youn
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.25-29
    • /
    • 2008
  • Purpose: To monitor the changes of location of prostate gland using DIPS and to examine the adjustment and proton beam therapy depending on the movement of prostate gland in proton beam therapy for prostate gland in which a fiducial gold marker was inserted. Materials and Methods: This study was conducted in ten patients with prostate cancer who received proton beam therapy since April of 2008. To monitor the change of prostate location, three fiducial gold markers were inserted prior to the treatment. To minimize the movement of prostate gland, patients were recommended to urinate prior to the treatment, to intake a certain amount of water and to concomitantly undergo rectal balloon. In these patients, the set-up position was identical to that for a CT-simulation. The PA (posterior-anterior) and lateral images were obtained using both DIPS (digital image positioning system) and a plain radiography, and they were compared between the two imaging modalities. Thus, the changes of the location of fiducial gold marker were assessed based on three coordinates (x, y, z) and then adjusted. This was followed by proton beam therapy. Results: Images which were taken using a plain radiography were compared with those which were taken using DIPS. In ten patients, according to a reference bony marker, the mean changes of the location of fiducial gold marker based on an iso-center were X-axis: $\pm$0.116 cm, Y-axis: $\pm$0.19 cm and Z-axis: $\pm$0.176 cm. These ten patients showed a difference in the changes of location of prostate gland and it ranged between RT: 0.04 cm and RT: 0.24 cm on the X-axis; between Inf: 0.03 cm and Sup: 0.42 cm on the Y-axis; and Post: 0.05 cm and Ant: 0.35 cm on the Z-axis. Conclusion: To minimize the movement of prostate gland, as the pre-treatment prior to the treatment. In all the patients, however, three fiducial gold markers showed a daily variation which were inserted in the prostate gland. Based on the above data, Thus, the requirement of gold marker matching system depending on the daily variation in the proton beam therapy for which more accurate establishment of target was confirmed. It is assumed that an accurate effect of proton beam therapy would be enhanced by adjusting the target-center depending on the location change of prostate gland using DIPS which was used in the current study.

  • PDF