• Title/Summary/Keyword: position calibration

Search Result 448, Processing Time 0.025 seconds

Viewing Angle-Improved 3D Integral Imaging Display with Eye Tracking Sensor

  • Hong, Seokmin;Shin, Donghak;Lee, Joon-Jae;Lee, Byung-Gook
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.4
    • /
    • pp.208-214
    • /
    • 2014
  • In this paper, in order to solve the problems of a narrow viewing angle and the flip effect in a three-dimensional (3D) integral imaging display, we propose an improved system by using an eye tracking method based on the Kinect sensor. In the proposed method, we introduce two types of calibration processes. First process is to perform the calibration between two cameras within Kinect sensor to collect specific 3D information. Second process is to use a space calibration for the coordinate conversion between the Kinect sensor and the coordinate system of the display panel. Our calibration processes can provide the improved performance of estimation for 3D position of the observer's eyes and generate elemental images in real-time speed based on the estimated position. To show the usefulness of the proposed method, we implement an integral imaging display system using the eye tracking process based on our calibration processes and carry out the preliminary experiments by measuring the viewing angle and flipping effect for the reconstructed 3D images. The experimental results reveal that the proposed method extended the viewing angles and removed the flipping images compared with the conventional system.

Estimation of Camera Calibration Parameters using Line Corresponding Method (선 대응 기법을 이용한 카메라 교정파라미터 추정)

  • 최성구;고현민;노도환
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.10
    • /
    • pp.569-574
    • /
    • 2003
  • Computer vision system is broadly adapted like as autonomous vehicle system, product line inspection, etc., because it has merits which can deal with environment flexibly. However, for applying it for that industry, it has to clear the problem that recognize position parameter of itself. So that computer vision system stands in need of camera calibration to solve that. Camera calibration consists of the intrinsic parameter which describe electrical and optical characteristics and the extrinsic parameter which express the pose and the position of camera. And these parameters have to be reorganized as the environment changes. In traditional methods, however, camera calibration was achieved at off-line condition so that estimation of parameters is in need again. In this paper, we propose a method to the calibration of camera using line correspondence in image sequence varied environment. This method complements the corresponding errors of the point corresponding method statistically by the extraction of line. The line corresponding method is strong by varying environment. Experimental results show that the error of parameter estimated is within 1% and those is effective.

Kinematic Calibration Method for Redundantly Actuated Parallel Mechanisms (여유구동 병렬기구의 기구학적 보정)

  • 정재일;김종원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.355-360
    • /
    • 2002
  • To calibrate a non-redundantly actuated parallel mechanism, one can find actual kinematic parameters by means of geometrical constraint of the mechanism's kinematic structure and measurement values. However, the calibration algorithm for a non-redundant case does not apply fur a redundantly actuated parallel mechanism, because the angle error of the actuating joint varies with position and the geometrical constraint fails to be consistent. Such change of joint angle error comes from constraint torque variation with each kinematic pose (meaning position and orientation). To calibrate a redundant parallel mechanism, one therefore has to consider constraint torque equilibrium and the relationship of constraint torque to torsional deflection, in addition to geometric constraint. In this paper, we develop the calibration algorithm fir a redundantly actuated parallel mechanism using these three relationships, and formulate cost functions for an optimization algorithm. As a case study, we executed the calibration of a 2-DOF parallel mechanism using the developed algorithm. Coordinate values of tool plate were measured using a laser ball bar and the actual kinematic parameters were identified with a new cost function of the optimization algorithm. Experimental results showed that the accuracy of the tool plate improved by 82% after kinematic calibration in a redundant actuation case.

  • PDF

Infrared LED Tracking and Aim Position Calibration for an Arcade Gun (아케이드 건(Gun)을 위한 적외선 LED 추적과 조준 위치 보정)

  • Baek, Seong-Ho;Kim, Jong-Soo;Kim, Tae-Yong
    • Journal of Korea Game Society
    • /
    • v.5 no.1
    • /
    • pp.3-10
    • /
    • 2005
  • In this paper, we propose an infrared LED tacking system called IRED Gun, which is designed for the game gun interface. The conventional systems are practically restricted by physical environment and are not robust to the measurement variations. We suggest the IRED Gun system to solve theses problems. Unlike conventional systems, our tracking system uses three infrared LED lights attached on monitor. Since the coordinate calibration is designed to regulate the detected target coordinates, more accurate aim position is calculated, which enables a game player to interact with a game more reliably. The experimental results verify the feasibility and validity of the calibration method and the infrared LED tacking system.

  • PDF

Calibration of the depth measurement system with a laser pointer, a camera and a plain mirror

  • Kim, Hyong-Suk;Lin, Chun-Shin;Gim, Seong-Chan;Chae, Hee-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1994-1998
    • /
    • 2005
  • Characteristic analysis of the depth measurement system with a laser, a camera and a rotating mirror has been done and the parameter calibration technique for it has been proposed. In the proposed depth measurement system, the laser beam is reflected to the object by the rotating mirror and again the position of the laser beam is observed through the same mirror by the camera. The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD. There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance. The calibration techniques to minimize the effect of such major parameters are proposed.

  • PDF

Position Estimation Using Magnetic Field Map (자기장 지도를 이용한 위치 추정)

  • Kim, Han-Sol;Moon, Woo-Sung;Seo, Woo-Jin;Baek, Kwang-Ryul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.4
    • /
    • pp.290-298
    • /
    • 2013
  • Geomagnetic is refracted by building's wall and pillar. Therefore refracted geomagnetic is able to be used as feature point. In a specific space, a mobile device that is equipped with magnetic sensor array measures 3-axis magnetic field for each point. Magnetic field map is acquired by collecting the every sample point in the magnetic field. The measured magnetic field must be calibrated, because each magnetic sensor has a distortion. For this reason, sensor distortion model and sensor calibration method are proposed in this paper. Magnetic field that is measured by mobile device matches magnetic field map. Result of the matching is used for position estimation. This paper implements hardware system for position estimation method using magnetic field map.

Depth calibration method of SWASH vessel using its position and ultrasonic sensor (SWASH형 시험선의 자세 및 초음파센서를 이용한 심도 보정 방법)

  • Hwang, Heesung;Cha, Jeongmin;You, Youngjoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1140-1141
    • /
    • 2017
  • Depth of SWASH(Small Waterplane Area Single Hull) vessel which is an input value of its control system is measured by ultrasonic sensor. Distance to the its center of gravity can be simply calculated through ultrasonic sensor attached to the front of the vessel from the known values. However, it is to be calibrated with respect to its position for the accurate depth because it has geometric relation between the measurement value of ultrasonic sensor and the depth. In this research, depth calibration method of SWASH vessel using its position and ultrasonic sensor is introduced.

  • PDF

Calibration Technology for Precise Alignment of Large Flat Panel Displays (대형 평판 디스플레이의 정밀 정렬을 위한 캘리브레이션 기술)

  • Hong, Jun-Ho;Shin, Dongwon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.3
    • /
    • pp.100-109
    • /
    • 2022
  • In this study, calibration technology that increases the alignment accuracy in large flexible flat panels was studied. For precise of calibration, a systematization of the calibration algorithm was established, and a calibration correction technique was studied to revise calibration errors. A coordinate systems of camera and UVW stage was established to get the global position of the mark, and equations for translational and rotational calibration were systematically derived based on geometrical analysis. Correction process for the calibration data was carried, and alignment experiments were performed sequentially in cases of the presence or absence of calibration-correction. Alignment results of both calibration correction and non-calibration correction showed accuracy performance less than 1㎛. On the other hand, the standard deviation in calibration-correction is smaller than non-calibration correction. Therefore, calibration correction showed improvement of the alignment repeatability.

Slit-light Laser Range Finding Using Perspective Warping Calibration (원근 와핑 보정을 이용한 선광원 레이저 거리 검출)

  • Ahn, Hyun-Sik
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.3
    • /
    • pp.232-237
    • /
    • 2010
  • In this paper, a slit light laser range finding method using perspective warping calibration is proposed. This approach has an advantage to acquire relatively high accuracy, although the optical system is nonlinear. In the calibration, we detect the calibration points which are marked on the calibration panel and acquire the center position of the slit light laser in the image, which are used for computing the real positions of the slit light by using perspective warping. A calibration file is obtained by integrating the calibration data with the transition of the panel. The range data is acquired by interpolating the center position of the slit light laser to the calibration coordinates. Experimental results show that the proposed method provides the accuracy of 0.08mm error in depth range of 130mm with the low cost optical system.

Design of Experimental Test Tracks for Odometry Calibration of Wheeled Mobile Robots (차륜형 이동로봇의 오도메트리 보정을 위한 실험적 주행시험경로 설계)

  • Jung, Changbae;Moon, Changbae;Jung, Daun;Chung, Woojin
    • The Journal of Korea Robotics Society
    • /
    • v.9 no.3
    • /
    • pp.160-169
    • /
    • 2014
  • Odometry using wheel encoder is a common relative positioning technique for wheeled mobile robots. The major drawback of odometry is that the kinematic modeling errors are accumulated when the travel distance increases. Therefore, accurate calibration of odometry is required. In several related works, various schemes for odometry calibration are proposed. However, design guidelines of test tracks for odometry calibration were not considered. More accurate odometry calibration results can be achieved by using appropriate test track because the position and orientation errors after the test are affected by the test track. In this paper, we propose the design guidelines of test tracks for odometry calibration schemes using experimental heading errors. Numerical simulations and experiments clearly demonstrate that the proposed design guidelines result in more accurate calibration results.