• Title/Summary/Keyword: position accuracy

Search Result 2,338, Processing Time 0.03 seconds

Analysis of the Operation Status and Function based on the Overseas Accident Investigation Agency (국외 재난원인조사기구의 운영 현황 및 기능분석)

  • Lee, Kyung-Su;Yang, Seung-Ho;Kim, Yeon-Ju;Park, Jihye;Kim, Tai-Hoon;Kim, Hyunju
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.442-453
    • /
    • 2021
  • Purpose: The objective of this study is to suggest desirable direction of Korean accident investigation organization by analyzing the operation status and way of overseas developed countries' investigation agency. Method: To accomplish the objective of this study, we were examined four main characteristics of accident investigation agencies of the U.S., Japan, and Sweden, focusing on (1); the background of the establishment, (2);organizational structure, (3);major tasks and functions, (4); accident investigation procedures. Result: First, the purpose of its establishment and task is to prevent recurrence of disasters and accidents, at the same time, administrating and researching duties such as legal system, policy, recommending improvement and conducting scientific disaster-cause analysis to contribute safety for the government. Second, it is operated as an independent organization under the president, not belonging to the ministry, in order to enable fair investigation in an impartial position. Third, it has the authority to be recognized for its expertise in the results of investigation. In other words, it is operated as a permanent organization with professional personnel, and secures authority through the accident research with indepth investigation and high-quality recommendations. Conclusion: The overseas investigation agencies rapidly manage and coordinate their operational practices in order to resolve national requirements and social conflicts with fairness, accuracy and expertise in accident investigations. In order to prevent the recurrence of similar events, Korea needs to efficiently reconstruct its investigative functions distributed by each government department. In addition, institutional improvement is needed to make general adjustments at the national level, organize and operate control tower for when the accident has happened.

Very short-term rainfall prediction based on radar image learning using deep neural network (심층신경망을 이용한 레이더 영상 학습 기반 초단시간 강우예측)

  • Yoon, Seongsim;Park, Heeseong;Shin, Hongjoon
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1159-1172
    • /
    • 2020
  • This study applied deep convolution neural network based on U-Net and SegNet using long period weather radar data to very short-term rainfall prediction. And the results were compared and evaluated with the translation model. For training and validation of deep neural network, Mt. Gwanak and Mt. Gwangdeoksan radar data were collected from 2010 to 2016 and converted to a gray-scale image file in an HDF5 format with a 1km spatial resolution. The deep neural network model was trained to predict precipitation after 10 minutes by using the four consecutive radar image data, and the recursive method of repeating forecasts was applied to carry out lead time 60 minutes with the pretrained deep neural network model. To evaluate the performance of deep neural network prediction model, 24 rain cases in 2017 were forecast for rainfall up to 60 minutes in advance. As a result of evaluating the predicted performance by calculating the mean absolute error (MAE) and critical success index (CSI) at the threshold of 0.1, 1, and 5 mm/hr, the deep neural network model showed better performance in the case of rainfall threshold of 0.1, 1 mm/hr in terms of MAE, and showed better performance than the translation model for lead time 50 minutes in terms of CSI. In particular, although the deep neural network prediction model performed generally better than the translation model for weak rainfall of 5 mm/hr or less, the deep neural network prediction model had limitations in predicting distinct precipitation characteristics of high intensity as a result of the evaluation of threshold of 5 mm/hr. The longer lead time, the spatial smoothness increase with lead time thereby reducing the accuracy of rainfall prediction The translation model turned out to be superior in predicting the exceedance of higher intensity thresholds (> 5 mm/hr) because it preserves distinct precipitation characteristics, but the rainfall position tends to shift incorrectly. This study are expected to be helpful for the improvement of radar rainfall prediction model using deep neural networks in the future. In addition, the massive weather radar data established in this study will be provided through open repositories for future use in subsequent studies.

Comparative and Feasibility Evaluation of Detection Ability of Relative Dosimeters using CsPbI2Br and CsPbIBr2 Materials in Brachytherapy QA (근접방사선치료 QA에서 CsPbI2Br과 CsPbIBr2를 이용한 상대 선량계들의 검출 능력 비교 및 적용가능성 평가)

  • Seung-Woo Yang;Sung-Kwang Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.433-440
    • /
    • 2023
  • High dose rate brachytherapy is a cancer treatment that intensively irradiates radiation to tumors by inserting isotopes with high dose rates into the body. For such a treatment, it is necessary to deliver an accurate dose to the tumor tissue through an accurate treatment plan while delivering only a minimum dose to the normal tissue. Therefore, it is very important to check the location accuracy of the source through accurate Quality Assurance (QA) in clinical practice. However, since the source position is determined using a ruler, automatic radiographer, video monitor, etc. in clinical practice, it yields inaccurate results. In this study, a semiconductor dosimeter using CsPbI2Br and CsPbIBr2 was fabricated. And, in order to analyze whether it is more suitable for the relative QA dosimeter for brachytherapy device among the two materials, the radiation detection ability of each was compared and evaluated. In order to evaluate the radiation detection ability in brachytherapy, the reproducibility and linearity of the two materials were evaluated in 192IR. In the reproducibility evaluation, CsPbI2Br presented a Relative Standard Deviatio(RSD) of 0.98% and CsPbIBr2 presented an RSD of 3.45%. In the linearity evaluation, the coefficient of determination (R2) of CsPbI2Br was presented as 0.9998, and the R2 of CsPbIBr2 was presented as 0.9994. As a result of the evaluation, it was found that CsPbI2Br was more stable in radiation detection while satisfying the evaluation criteria in the dosimeter manufactured in this experiment. Therefore, CsPbI2Br material is suitable for application as a relative dosimeter for radiation detection in brachytherapy devices.

Accuracy of bite registration according to the buccal bite scan range of intra-oral scanner (구강 스캐너의 협측 교합 스캔 부위에 따른 교합 인기의 정확도)

  • Tae-sung Kwon;Dae-hyun Kim;Min-su Kim;Dong-jun Song;Joo-Hun Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.125-134
    • /
    • 2024
  • Purpose: The aim of this study was to determine which scan range would provide the most accurate bite registration when performing a bite scan after scanning an upper and lower arch using an intraoral scanner. Materials and Methods: The occlusal contact points were recorded using articulating paper for 30 adults, and the results of various ranges of buccal bite scan were compared based on this. Buccal bite scan of 5 ranges (1st premolar to 2nd premolar, 1st premolar to 1st molar, 1st premolar to 2nd molar, 2nd premolar to 1st molar, and canines to another side canine of the maxillary teeth) was performed, and then the buccal bite scan file was used in a CAD program to confirm the occlusal area in the scan file through data editing and alignment, leaving the buccal area of the teeth. Afterwards, the degree of agreement between the occlusal contact points obtained from the articulating paper and the occlusal area obtained from the scan file was compared, and statistical analysis was performed using the homoscedastic T-test (α = 0.05). Results: The alignment success and alignment failure rates among each group were 77.23% and 40.85% in canine to another side canine, 68.23% and 28.89% in bilateral first premolar to second premolar, 63.76% and 29.97% in bilateral first premolar to first molar, 61.31% and 32.04% in bilateral first premolar to second molar, 67.55% and 27.46% in second premolar to first molar. The results of the anterior scan of both canines showed higher alignment success and failure rates compared to the scan results of all maxillary posterior teeth. In the alignment success rate, statistical significance was not found depending on the scan range of the posterior teeth, but in comparing the results of the posterior teeth and both canines, statistical significance was observed except for the scan results of the second premolar to the first molar. There was no statistical significance in the alignment failure rate depending on the scan range of the posterior teeth, and statistical significance was observed in the results of the posterior teeth and both canines. Conclusion: When taking a buccal bite scan, in the case of scanning the anterior teeth, more occlusal area appear than when scanning the posterior teeth, and in the case of scanning the posterior teeth, there is no significant difference in the bite registration depending on the scan range.

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

Studies on the Derivation of the Instantaneous Unit Hydrograph for Small Watersheds of Main River Systems in Korea (한국주요빙계의 소유역에 대한 순간단위권 유도에 관한 연구 (I))

  • 이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.1
    • /
    • pp.4296-4311
    • /
    • 1977
  • This study was conducted to derive an Instantaneous Unit Hydrograph for the accurate and reliable unitgraph which can be used to the estimation and control of flood for the development of agricultural water resources and rational design of hydraulic structures. Eight small watersheds were selected as studying basins from Han, Geum, Nakdong, Yeongsan and Inchon River systems which may be considered as a main river systems in Korea. The area of small watersheds are within the range of 85 to 470$\textrm{km}^2$. It is to derive an accurate Instantaneous Unit Hydrograph under the condition of having a short duration of heavy rain and uniform rainfall intensity with the basic and reliable data of rainfall records, pluviographs, records of river stages and of the main river systems mentioned above. Investigation was carried out for the relations between measurable unitgraph and watershed characteristics such as watershed area, A, river length L, and centroid distance of the watershed area, Lca. Especially, this study laid emphasis on the derivation and application of Instantaneous Unit Hydrograph (IUH) by applying Nash's conceptual model and by using an electronic computer. I U H by Nash's conceptual model and I U H by flood routing which can be applied to the ungaged small watersheds were derived and compared with each other to the observed unitgraph. 1 U H for each small watersheds can be solved by using an electronic computer. The results summarized for these studies are as follows; 1. Distribution of uniform rainfall intensity appears in the analysis for the temporal rainfall pattern of selected heavy rainfall event. 2. Mean value of recession constants, Kl, is 0.931 in all watersheds observed. 3. Time to peak discharge, Tp, occurs at the position of 0.02 Tb, base length of hlrdrograph with an indication of lower value than that in larger watersheds. 4. Peak discharge, Qp, in relation to the watershed area, A, and effective rainfall, R, is found to be {{{{ { Q}_{ p} = { 0.895} over { { A}^{0.145 } } }}}} AR having high significance of correlation coefficient, 0.927, between peak discharge, Qp, and effective rainfall, R. Design chart for the peak discharge (refer to Fig. 15) with watershed area and effective rainfall was established by the author. 5. The mean slopes of main streams within the range of 1.46 meters per kilometer to 13.6 meter per kilometer. These indicate higher slopes in the small watersheds than those in larger watersheds. Lengths of main streams are within the range of 9.4 kilometer to 41.75 kilometer, which can be regarded as a short distance. It is remarkable thing that the time of flood concentration was more rapid in the small watersheds than that in the other larger watersheds. 6. Length of main stream, L, in relation to the watershed area, A, is found to be L=2.044A0.48 having a high significance of correlation coefficient, 0.968. 7. Watershed lag, Lg, in hrs in relation to the watershed area, A, and length of main stream, L, was derived as Lg=3.228 A0.904 L-1.293 with a high significance. On the other hand, It was found that watershed lag, Lg, could also be expressed as {{{{Lg=0.247 { ( { LLca} over { SQRT { S} } )}^{ 0.604} }}}} in connection with the product of main stream length and the centroid length of the basin of the watershed area, LLca which could be expressed as a measure of the shape and the size of the watershed with the slopes except watershed area, A. But the latter showed a lower correlation than that of the former in the significance test. Therefore, it can be concluded that watershed lag, Lg, is more closely related with the such watersheds characteristics as watershed area and length of main stream in the small watersheds. Empirical formula for the peak discharge per unit area, qp, ㎥/sec/$\textrm{km}^2$, was derived as qp=10-0.389-0.0424Lg with a high significance, r=0.91. This indicates that the peak discharge per unit area of the unitgraph is in inverse proportion to the watershed lag time. 8. The base length of the unitgraph, Tb, in connection with the watershed lag, Lg, was extra.essed as {{{{ { T}_{ b} =1.14+0.564( { Lg} over {24 } )}}}} which has defined with a high significance. 9. For the derivation of IUH by applying linear conceptual model, the storage constant, K, with the length of main stream, L, and slopes, S, was adopted as {{{{K=0.1197( {L } over { SQRT {S } } )}}}} with a highly significant correlation coefficient, 0.90. Gamma function argument, N, derived with such watershed characteristics as watershed area, A, river length, L, centroid distance of the basin of the watershed area, Lca, and slopes, S, was found to be N=49.2 A1.481L-2.202 Lca-1.297 S-0.112 with a high significance having the F value, 4.83, through analysis of variance. 10. According to the linear conceptual model, Formular established in relation to the time distribution, Peak discharge and time to peak discharge for instantaneous Unit Hydrograph when unit effective rainfall of unitgraph and dimension of watershed area are applied as 10mm, and $\textrm{km}^2$ respectively are as follows; Time distribution of IUH {{{{u(0, t)= { 2.78A} over {K GAMMA (N) } { e}^{-t/k } { (t.K)}^{N-1 } }}}} (㎥/sec) Peak discharge of IUH {{{{ {u(0, t) }_{max } = { 2.78A} over {K GAMMA (N) } { e}^{-(N-1) } { (N-1)}^{N-1 } }}}} (㎥/sec) Time to peak discharge of IUH tp=(N-1)K (hrs) 11. Through mathematical analysis in the recession curve of Hydrograph, It was confirmed that empirical formula of Gamma function argument, N, had connection with recession constant, Kl, peak discharge, QP, and time to peak discharge, tp, as {{{{{ K'} over { { t}_{ p} } = { 1} over {N-1 } - { ln { t} over { { t}_{p } } } over {ln { Q} over { { Q}_{p } } } }}}} where {{{{K'= { 1} over { { lnK}_{1 } } }}}} 12. Linking the two, empirical formulars for storage constant, K, and Gamma function argument, N, into closer relations with each other, derivation of unit hydrograph for the ungaged small watersheds can be established by having formulars for the time distribution and peak discharge of IUH as follows. Time distribution of IUH u(0, t)=23.2 A L-1S1/2 F(N, K, t) (㎥/sec) where {{{{F(N, K, t)= { { e}^{-t/k } { (t/K)}^{N-1 } } over { GAMMA (N) } }}}} Peak discharge of IUH) u(0, t)max=23.2 A L-1S1/2 F(N) (㎥/sec) where {{{{F(N)= { { e}^{-(N-1) } { (N-1)}^{N-1 } } over { GAMMA (N) } }}}} 13. The base length of the Time-Area Diagram for the IUH was given by {{{{C=0.778 { ( { LLca} over { SQRT { S} } )}^{0.423 } }}}} with correlation coefficient, 0.85, which has an indication of the relations to the length of main stream, L, centroid distance of the basin of the watershed area, Lca, and slopes, S. 14. Relative errors in the peak discharge of the IUH by using linear conceptual model and IUH by routing showed to be 2.5 and 16.9 percent respectively to the peak of observed unitgraph. Therefore, it confirmed that the accuracy of IUH using linear conceptual model was approaching more closely to the observed unitgraph than that of the flood routing in the small watersheds.

  • PDF

Analysis of Football Fans' Uniform Consumption: Before and After Son Heung-Min's Transfer to Tottenham Hotspur FC (국내 프로축구 팬들의 유니폼 소비 분석: 손흥민의 토트넘 홋스퍼 FC 이적 전후 비교)

  • Choi, Yeong-Hyeon;Lee, Kyu-Hye
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.3
    • /
    • pp.91-108
    • /
    • 2020
  • Korea's famous soccer players are steadily performing well in international leagues, which led to higher interests of Korean fans in the international leagues. Reflecting the growing social phenomenon of rising interests on international leagues by Korean fans, the study examined the overall consumer perception in the consumption of uniform by domestic soccer fans and compared the changes in perception following the transfers of the players. Among others, the paper examined the consumer perception and purchase factors of soccer fans shown in social media, focusing on periods before and after the recruitment of Heung-Min Son to English Premier League's Tottenham Football Club. To this end, the EPL uniform is the collection keyword the paper utilized and collected consumer postings from domestic website and social media via Python 3.7, and analyzed them using Ucinet 6, NodeXL 1.0.1, and SPSS 25.0 programs. The results of this study can be summarized as follows. First, the uniform of the club that consistently topped the league, has been gaining attention as a popular uniform, and the players' performance, and the players' position have been identified as key factors in the purchase and search of professional football uniforms. In the case of the club, the actual ranking and whether the league won are shown to be important factors in the purchase and search of professional soccer uniforms. The club's emblem and the sponsor logo that will be attached to the uniform are also factors of interest to consumers. In addition, in the decision making process of purchase of a uniform by professional soccer fan, uniform's form, marking, authenticity, and sponsors are found to be more important than price, design, size, and logo. The official online store has emerged as a major purchasing channel, followed by gifts for friends or requests from acquaintances when someone travels to the United Kingdom. Second, a classification of key control categories through the convergence of iteration correlation analysis and Clauset-Newman-Moore clustering algorithm shows differences in the classification of individual groups, but groups that include the EPL's club and player keywords are identified as the key topics in relation to professional football uniforms. Third, between 2002 and 2006, the central theme for professional football uniforms was World Cup and English Premier League, but from 2012 to 2015, the focus has shifted to more interest of domestic and international players in the English Premier League. The subject has changed to the uniform itself from this time on. In this context, the paper can confirm that the major issues regarding the uniforms of professional soccer players have changed since Ji-Sung Park's transfer to Manchester United, and Sung-Yong Ki, Chung-Yong Lee, and Heung-Min Son's good performances in these leagues. The paper also identified that the uniforms of the clubs to which the players have transferred to are of interest. Fourth, both male and female consumers are showing increasing interest in Son's league, the English Premier League, which Tottenham FC belongs to. In particular, the increasing interest in Son has shown a tendency to increase interest in football uniforms for female consumers. This study presents a variety of researches on sports consumption and has value as a consumer study by identifying unique consumption patterns. It is meaningful in that the accuracy of the interpretation has been enhanced by using a cluster analysis via convergence of iteration correlation analysis and Clauset-Newman-Moore clustering algorithm to identify the main topics. Based on the results of this study, the clubs will be able to maximize its profits and maintain good relationships with fans by identifying key drivers of consumer awareness and purchasing for professional soccer fans and establishing an effective marketing strategy.

The Benefit of KT-2000 Knee Ligament Arthrometer in Diagnosis of Anterior Cruciate Ligament Injury (슬관절 전방 십자 인대 파열의 진단에 있어서 KT-2000 기기의 유용성)

  • Park, Jai-Hyung;Kim, Hyoung-Soo;Jung, Kwang-Gyu;Yoo, Jeong-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.82-88
    • /
    • 2004
  • Purpose: In this study, we intended to ascertain the benefit of KT-2000 Knee arthrometer(KT-2000) in the diagnosis of ACL(Anterior cruciate ligament) injury by comparing the anterior displacement of normal knee with that of ACL deficient knee. Materials and Methods: We designated two examiners to measure the anterior displacement of the knee joint of 30 healthy individuals, using KT-2000, at 30$^{\circ}$ flexion setting of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation and analyzed these results according to the variables and measured the preoperative anterior displacement of the ACL injured knee in the 30 patients who have gone through an arthroscopic ACL reconstruction later. Results: The results of examiner 1 are 6.5${\pm}$1.5 mm, 2.5${\pm}$0.9 mm, 4.8${\pm}$1.2 mm, 6.4${\pm}$1.3 mm in right knee and 5.6${\pm}$1.3 mm, 2.1${\pm}$0.8 mm, 4.5${\pm}$1.2 mm, 5.2${\pm}$1.3 mm in left knee, in order of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation. The results of examiner 2 are 6.9${\pm}$1.2mm, 2.9${\pm}$1.1mm, 5.6${\pm}$1.6mm, 6.9${\pm}$1.5mm in right, 5.5${\pm}$1.7 mm,1.9${\pm}$0.9 mm, 5.1${\pm}$1.9 mm, 5.7${\pm}$1.6 mm in left knee, The side to side difference of examiner 1 in the setting of muscle relaxation is 0.9${\pm}$1.0 mm. The anterior displaement of ACL injured knee is average 11${\pm}$2.93 mm and difference of average 6.5${\pm}$2.31 mm form that of normal. In comparison between the right and left knees of healthy individuals, the both results of two examiners showed the statistical difference in the setting of muscle full relaxation but, the results showed the side to side difference below 2 mm in 25case(83%), 21case(70%) respectively and above 3 mm in just 1 case. In the comparison between the normal and ACL injured knees, the results show the statistical difference of the side to side difference in the setting of muscle relaxation(p<0.05). Conclusion: The KT-2000 result is affected by relaxation of muscles around knee, flexion angle of knee joint, rotation of tibia, the strength of displacing force, time of the test and physical factors as height and weight. However, the Accuracy of diagnosis of ACL injury by KT-2000 will increase if the examiner is skillful and the tests are made on the exact position of knee joint.

  • PDF