• Title/Summary/Keyword: portable application

Search Result 368, Processing Time 0.029 seconds

Development of Portable Conversation-Type English Leaner (대화식 휴대용 영어학습기 개발)

  • Yoo, Jae-Tack;Yoon, Tae-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.147-149
    • /
    • 2004
  • Although most of the people have studied English for a long time, their English conversation capability is low. When we provide them portable conversational-type English learners by the application of computer and information process technology, such portable learners can be used to enhance their English conversation capability by their conventional conversation exercises. The core technology to develop such learner is the development of a voice recognition and synthesis module under an embedded environment. This paper deals with voice recognition and synthesis, prototype of the learner module using a DSP(Digital Signal Processing) chip for voice processing, voice playback function, flash memory file system, PC download function using USB ports, English conversation text function by the use of SMC(Smart Media Card) flash memory, LCD display function, MP3 music listening function, etc. Application areas of the prototype equipped with such various functions are vast, i.e. portable language learners, amusement devices, kids toy, control by voice, security by the use of voice, etc.

  • PDF

Development CMOS Sensor-Based Portable Video Scope and It's Image Processing Application (CMOS 센서를 이용한 휴대용 비디오스코프 및 영상처리 응용환경 개발)

  • 김상진;김기만;강진영;김영욱;백준기
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.517-520
    • /
    • 2003
  • Commercial video scope use CCD sensor and frame grabber for image capture and A/D interface but application limited by input resolution and high cost. In this paper we introduce portable video scope using CMOS sensor, USB pen and tuner card (low frame grabber) in place of commercial CCD sensor and frame grabber. Our video scope serves as an essential link between advancing commercial technology and research, providing cost effective solutions for educational, engineering and medical applications across an entire spectrum of needs. The software implementation is done using Direct Show in second version after initial trials using First version VFW (video for window), which gave very low frame rate. Our video scope operates on windows 98, ME, XP, 2000. The drawback of our video scope is crossover problem in output images caused due to interpolation, which has to be rectified for more efficient performance.

  • PDF

Operating characteristics of an air cooling PEMFC for portable application (이동 전원용 공랭식 고분자 연료전지의 제작 및 운전 특성 연구)

  • Sohn Young-Jun;Park Gu-Gon;Yang Tae-Hyun;Yoon Young-Gi;Lee Won-Yong;Yim Sung-Dae;Kim Chang-Soo
    • New & Renewable Energy
    • /
    • v.1 no.1 s.1
    • /
    • pp.72-78
    • /
    • 2005
  • Optimal design and proper operation are important to get aimed output power of a polymer electrolyte membrane fuel cell (PEMFC) stack. An air cooling fuel cell stack is widely used in sub kW PEMFC systems. The purpose of this study is to analyze operating conditions affecting the performance of the air cooling PEMFC which is designed for portable application. In portable applications, air cooling stack is difficult to maintain well balanced operating conditions. The importart parameters are the relative humidity, the temperature of the stack, the utilization of reactant gas and so on. in this study, a 500W air cooling PEMFC was fabricated and tested to evaluate the design performance and to determine optimal operating conditions. Moreover, basic modeling also is carried out. These results can be used 3s design criteria and optimal operating conditions for portable PEMFCs

  • PDF

Evaluating the Application of Portable Safety Equipment in Nuclear Power Plants using Multi-unit PSA (다수기 PSA 기반 원자력 발전소 이동형 안전 설비 활용성 평가)

  • Jae Young Yoon;Ho-Gon Lim;Jong Woo Park
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.110-120
    • /
    • 2023
  • Following the Fukushima accident, portable equipment employed as accident mitigating systems have been installed and operated to reduce core damage and large early release frequencies. In addition, the establishment of an accident management strategy has gained importance. This study investigated the current status of portable equipment including the international portable equipment FLEX (diverse and flexible coping strategies), and domestic portable equipment multi-barrier accident coping strategy (MACST). Research on optimal utilization of MACST remains insufficient. As a preliminary study for establishing an optimal strategy, sensitivity studies were conducted to facilitate the priority of use on portable equipment, number of portable equipment, and dependency of operator actions based on a multi-unit probabilistic safety assessment model. The results revealed the conditions that reduced the multi-unit and site conditional core damage probabilities, indicating the optimal strategy of MACST. The results of this study can be used as a reference for establishing an optimal strategy that utilizes domestic safety equipment in the future.

Development of a Portable Potentiostat with Wireless Communications for Measuring Dissolved Oxygen (용존산소 측정을 위한 무선통신 기반 휴대형 포텐쇼스탯 개발)

  • Lee, Hyun-Seok;Han, Ji-Hoon;Pak, Jungho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1641-1647
    • /
    • 2018
  • In this paper, we describe a portable potentiostat which is capable of cyclic voltammetry(CV) and amperometry for electrochemical dissolved oxygen sensor. In addition, this portable potentiostat can also transmit the measured data wirelessly to android devices such as smart phone, tablet, etc. through Bluetooth. The potentiostat system consists of three parts; a voltage generator circuit which is controlled by Arduino nano and 12-bit DAC(digital to analog converter) to generate necessary electric potential for operating the electrochemical sensor, an oxidation/reduction current measurement circuit, and a Bluetooth module to transmit data wirelessly to an android device. Once measurements are carried out with the android application, the measured data is transmitted to the android device via Bluetooth and displayed using the android app. in real time. In this paper, we report the measured reduction current with a fabricated dissolved oxygen sensor in both saturated-oxygen state and zero-oxygen states. The results of the developed portable potentiostat system are in good agreement with those of the commercial portable potentiostat (${\mu}stat200$, Dropsens inc.). The measured peak reduction currents using the developed potentiostat and the commercial ${\mu}stat200$ potentiostat were $-0.755{\mu}A$ and $-0.724{\mu}A$, respectively. The reduction currents measured at zero-oxygen state were $-0.005{\mu}A$ and $-0.004{\mu}A$. The discrepancy between those two systems seems very small, which implies successful development of a portable and wireless potentionstat.

A Portable ECG System Coupled with a Smartphone (스마트폰과 연동한 휴대용 심전도계)

  • Kim, Kiwan;An, Jonghyun;Park, Kwangmin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.1
    • /
    • pp.7-11
    • /
    • 2021
  • The electrocardiogram(ECG) and heart rates are essential for diagnosing heart disease. However, conventional portable ECG devices are possible to only measure heart rates or have limitations in how and where they are measured. In this paper, a portable ECG system in which ECG waveforms and heart rates are displayed on smartphone screens is developed. A smartphone is used as display equipment instead of a computer screen for continuous monitoring. The developed ECG system filters and amplifies detected analog ECG signals. Next, it converts the amplified analog ECG signals into digital signals, then transmits to the smartphone via Bluetooth communication. This ECG system can display and store biomedical signals on a smartphone through the application. As a result, the waveform and heart rates of the developed portable ECG system has been confirmed to be similar to those of existing medical devices.

Solid Chemical Material Site Analysis Research of Event Site (사건현장의 고체상 화학물질 현장분석 연구)

  • Kim, Sungbum;Noh, Hyeran;Lee, Jinseon;Kim, Jungmin;Cho, Munsik;Park, Choonhwa;Chun, Kwangsoo;Ahn, Seungyoung;Seok, Gwangseol
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.3
    • /
    • pp.304-309
    • /
    • 2012
  • National Institute of Environmental Research has Portable FT-IR(Fourier Transform Infrared Spectroscopy, A2 Technologies, U.S.A.) and Portable XRD(X-ray Diffraction, Olympus Innov-X co., U.S.A.) for the analysis of the solid sample rapidly on the spot where chemical terror accident took place and the portable equipments are operating now. However, we need a series of the analysis procedures for an efficient application of the equipments and getting the rapid analytical value about the investigation and sampling on the spot. And the accuracy of the portable equipments' analytical value is high but the application of them in an emergency is low because we are lack of the procedures about field-centered analysis and the usage. Therefore we would like to organize the result of this research about field analysis and the procedures of the solid portable equipments. And we also would like to apply it to the field of chemical terror accident.

Statistical Analysis of Major Accident Reports and Development of a Real-time Detection Model for Portable Ladder and Safety Helmet (이동식사다리 중대재해 통계 분석 및 이동식사다리와 안전모 실시간 탐지 기계학습 모델 개발)

  • Choi, Seung-Ju;Jung, Kihyo
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.1
    • /
    • pp.9-15
    • /
    • 2021
  • The leading source of occupational fatalities is a portable ladder in Korea because it is widely used in industry as work platform. In order to reduce victims, it is necessary to establish preventive measures for the accidents caused by portable ladder. Therefore, this study statistically analyzed injury death by portable ladder for recent 10 years to investigate the accident characteristics. Next, to monitor wearing of safety helmet in real-time while working on a portable ladder, this study developed an object detection model based on the You Only Look Once(YOLO) architecture, which can accurately detect objects within a reasonable time. The model was trained on 6,023 images with/without ladders and safety helmets. The performance of the proposed detection model was 0.795 for F1 score and 0.843 for mean average precision. In addition, the proposed model processed at least 25 frames per second which make the model suitable for real-time application.

A portable electronic nose (E-Nose) system using PDA device (개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발)

  • Yang, Yoon-Seok;Kim, Yong-Shin;Ha, Seung-Chul;Kim, Yong-Jun;Cho, Seong-Mok;Pyo, Hyeon-Bong;Choi, Chang-Auck
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.

Realization of A Portable Friction Coefficient Tester (휴대용 마찰계수 시험기 구현)

  • Seo, Sang Woon;Lyou, Joon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.4
    • /
    • pp.67-73
    • /
    • 2015
  • Recently in the evaluation of physical properties of a material, its surface friction characteristics is much required. This study treats the development of portable and affordable friction coefficient tester, which includes utensil design and application, measurement circuit design and layout, and microprocessor based firmware building. Also, real applicability of the present portable friction coefficient tester has been shown via performance comparisons with the existing standard tester.