• Title/Summary/Keyword: portable FES system

Search Result 8, Processing Time 0.02 seconds

A portable multichannel FES system for control of paralyzed extremities (마비된 말단근육의 제어를 위한 휴대용 다중 채널의 기능적 전기자극(FES) 장치)

  • 류영재;박봉기;김영민;임영철;김하경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.90-94
    • /
    • 1992
  • A portable multichannel functional electrical stimulation(FES) system for the fine control of the paralyzed extremities in spinal cord injury patients is described. This system is composed of a stimulation data creating system, a serial communication device, a 16-bit microprocessor, D/A converter of 32 channels and a display device. Stimulation patterns are created from analytical results of integrated EMGs during motion in normal subjects and are stored in the stimulation data creating system as data files. And then the stimulation patterns are sent to the memory in the portable multichannel FES system through serial communication interfacing device. Sophisticated fine control of paralyzed extrimities was realized by transmitting multichannel stimulation patterns to percutaneous intramuscular electrodes, which stimulate the motor function of paralyzed muscle simultaneously. Advantages of this system are as follws: 1) It is possible to modify stimulation patterns in accordance with the patient's situation. 2) This system is small and light.

  • PDF

Portable Gait-Event Detection System for FES Locomotion (FES 보행을 위한 휴대용 보행 이벤트 검출 시스템)

  • Kong, Se-Jin;Kim, Chul-Seung;Park, Kwan-Yong;Eom, Gwang-Moon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.5
    • /
    • pp.248-253
    • /
    • 2006
  • The purpose of this study is to develop a portable gait-event detection system which is necessary for the cycle-to-cycle FES(functional electrical stimulation) control of locomotion. To make the system portable, we made following modifications in the gait signal measurement system. That is, 1) to make the system wireless using Bluetooth communication, 2) to make the system small-sized and battery-powered by using low power consumption ${\mu}$ P(ATmega8535L). The gait-events were analyzed in off-line at the main computer using ANN(Artificial Neural Network). The Proposed system showed no mis-detection of the gait-events of normal subject and hemiplegia subjects. The performance of the system was better than the previous wired-system.

An Improved FES System for Control of Paralyzed Upper Extremity

  • Ryoo, Young-Jae;Kim, Young-Min;Park, Chul-Soo;Park, Bong-Kee;Lim, Young-Chul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.120-122
    • /
    • 1993
  • This paper describes an improved FES system to restore paralyzed extremities in spinal cord injury patients. For composing stimulus pattern which is suitable for each muscle, electrical stimulus pattern creating system is also developed by using IBM-PC. In the improved portable FES system using V40 microprocessor, muscle fatigue can be decreased by selecting the stimulus frequency which is proper to the response characteristics of each muscle. Driving softwares for the portable FES system and the stimulus pattern creating system are programmed with assembler and C language. A multichnnel portable FES system is designed to minimize the sire and weight using a D/A converter and 32 channel multiplexer.

  • PDF

A Study on the design of functional electrical stimulation system for hemiplegic patients (편마비환자를 위한 휴대용 자극시스템 설계에 관한 연구)

  • Kim, N.H.;Park, J.K.;Kwon, J.W.;Jang, Y.K.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.99-102
    • /
    • 1996
  • The ultimate object of FES is on the recovering function of body and shape demaged from desease or injury to original state. On this study, object is recovering of gait function of the disabled who, especially, have gait disturbance. Paralyzed muscle from the central nerve disable, if peripheral nerves which be in the lower part of the harmed are activated, muscle contraction is possible. The traumatic trouble, peripheral nerves aren't connected to a central nerve but origin of peripheral nerve cells which are in the lower part of the harmed are alive, react on stimulation. We design 4-channel stimulator, being based on standard stimuli pattern. stimulator is manufactured with compact size and light weight to portable.

  • PDF

Comparison of Balance and Fall Efficacy of Virtual Reality Program in Elderly Women with Fall Experience

  • Park, Seong-Doo;Kim, Jin-Young;Yu, Seong-Hun;Yang, Kyung-Hee;Song, Hyun-Seung
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.6
    • /
    • pp.430-435
    • /
    • 2014
  • Purpose: The objective of this study was a virtual reality-based balance training program effective for improvement in physical function, examined the balance ability and fall efficacy of elderly women with experienced falls, intending to examine the program's usefulness as an exercise program to prevent the recurrence of a fall. Methods: The participants were 30 elderly women aged 65 or older who met the conditions. The participants were randomly assigned to either a balance training group (BT) or a virtual reality-based balance training group (VT) and received the training three times per week, 30 minutes per day, for six weeks. To measure static balance, the Tetrax Portable Multiple System (Tetrax Ltd, Israel) were used. To measure dynamic balance, the Berg Balance Scale (BBS) and functional reach test (FRT) was used, and regarding fall efficacy, the Korean Fall Efficacy Scale (K-FES) was used. Results: Tetrax significantly improved after the intervention in both the BT group and the VT group (p<0.05). The comparison between the two groups was not significantly. BBS and FRT result significantly improved after the intervention in both the BT and VT groups (p<0.001), while K-FES was significantly ameliorated in the VT group only (p<.05). Comparing the groups, there were more significant changes in the BBS (p<0.05) and FRT (p<0.01) result of the VT group than the BT group. Conclusion: A virtual reality-based balance training program is considered to be usable as an exercise program to prevent recurrence of falls in elderly women.

Evaluation of Static Error Signal for Super Slim Optical Pick-up (초소형 광 픽업의 정적 오차 신호 검출)

  • Kang, S.M.;Cho, E.H.;Sohn, J.S.;Kim, W.C.;Park, N.C.;Park, Y.P.
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.2
    • /
    • pp.115-120
    • /
    • 2005
  • As a popularity of a portable digital device such as a cellular phone, a digital camera and a MP3 player is spreading, the demand of the mobile storage device increases rapidly. A bluray technology using 405nm laser diode and objective lens having high NA(Numerical Aperture), 0.85, satisfies a miniaturization and a high capacity which are the requirements of the portable device. To develop SFFOP(small form factor optical pickup), it is prerequisite to minimize the number of optical components and establish evaluation and assembly method of micro optical pickup system as well as mass production method of micro optical component. To minimize optical elements of optical pickup, there have been many researches to use P-HOE(Polarized Holographic Optical Element) due to its extremely small size and versatile function. However, P-HOE is handled and assembled very accurately in SFFOP. In this paper, static error signal detection method is developed for an alignment of P-HOE in SFFOP. Using developed static error signal detection method, P-HOE can be aligned very accurately with real time result of static error signals of pickup such as FES(focusing error signal) and TES(Tracking Error Signal). The developed static error signal detection method is verified by the evaluation of commercialized DVD Pickup. And finally. developed static error signal detection method is applied for the assembly of P-HOE in SFFOP system satisfies specification of BD(Blu-ray Disk).

  • PDF

Development of Closed-loop Control Type FES System for Restoration of Gait in Patients with Foot Drop (족하수 환자의 보행보조를 위한 피드백 제어형 전기자극기 개발)

  • 정호춘;임승관;이상세;진달복;박병림
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.183-190
    • /
    • 1999
  • The purpose of this study was to develop a portable and convenient closed-loop contrel type electrical stimulator for patients with foot drop. This system restores walking movement as well as prevents from atrophy or necrosis of lower limb muscles and increases blood circulation in hemiplegic patients caused by traffic accident, industrial disaster or stoke. This system detects the changes of the ankle joint angle during walking, and then controls the stimulus intensity automatically to maintain the programmed level of the ankle joint angle. Also, this automatic system controls the stimulus intensity which is affected by increased electrode impedance resulting from long time use. The system detects the joint angle by an optical sensor and includes modified PID control which adjusts the stimulus intensity if the joint angle deviates from the preset value. Stimulus parameters are 30~80 volt, 40 Hz, and 0.2 ms. The system was applied to five hemiplegic patients for 42 days. Duration of stimulation was 15 min/day for the first week and then the duration was gradually increased to 30, 60, 90 and 120 min/day. The muscle force was increased up to 29.7%, muscle fatigue was decreased compared with the level before stimulation and the pattern of locomotion was improved. These results suggest that the electrical stimulator with closed-loop control type is more convenient and effective in restoration of locomotion of patients with foot drop than open-loop system.

  • PDF

Development of Integrated Optical Pickup for Small Form Factor Optical Disc Drive (Small Form Factor 광 디스크 드라이브용 초소형 집적형 광픽업 개발)

  • Cho, Eun-Hyoung;Sohn, Jin-Seung;Lee, Myung-Bok;Suh, Sung-Dong;Kim, Hae-Sung;Kang, Sung-Mook;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.3
    • /
    • pp.163-168
    • /
    • 2006
  • Small form factor optical pickup (SFFOP) corresponding to BD specifications is strongly proposed for the next-generation portable storage device. In order to generate SFFOP, small sized optical pickup has been fabricated. We have developed a small sited optical pickup that is called the integrated optical pickup (IOP). The fabrication method of this system is mainly dependant on the use of the wafer based micro fabrication technology, which has been used in MEMS process such as photolithography, reactive ion etching, wafer bonding, and packaging process. This approach has the merits for mass production and high assembling accuracy. In this study, to generate the small sized optical pickup for high recording capacity, IOP corresponding to BD specifications has been designed and developed, including three main parts, 1) design, fabrication and evaluation of objective lens unit, 2) design and fabrication of IOP and 3) evaluation process of FES and TES.

  • PDF