• Title/Summary/Keyword: portable

Search Result 2,910, Processing Time 0.044 seconds

Implementation of a Portable ECG Recorder Using Wire and Wireless Communication Network (유.무선 통신망을 이용한 휴대용 심전도계 구현)

  • 김상득;배용욱;박준홍;구자헌;서희돈
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.85-88
    • /
    • 2001
  • In this paper, we designed a portable ECG Recorder which can transmit collected ECG data using wire and wireless communication network. The portable ECG recorder is characterized by the small-sized and the low-power consumption. The ECG data is transmitted to a hospital using internet or PSTN. We designed the protocol in order to transmit safely The portable ECG recording system will contribute largely to telemedicine for a cardiac patient.

  • PDF

Solid Chemical Material Site Analysis Research of Event Site (사건현장의 고체상 화학물질 현장분석 연구)

  • Kim, Sungbum;Noh, Hyeran;Lee, Jinseon;Kim, Jungmin;Cho, Munsik;Park, Choonhwa;Chun, Kwangsoo;Ahn, Seungyoung;Seok, Gwangseol
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.3
    • /
    • pp.304-309
    • /
    • 2012
  • National Institute of Environmental Research has Portable FT-IR(Fourier Transform Infrared Spectroscopy, A2 Technologies, U.S.A.) and Portable XRD(X-ray Diffraction, Olympus Innov-X co., U.S.A.) for the analysis of the solid sample rapidly on the spot where chemical terror accident took place and the portable equipments are operating now. However, we need a series of the analysis procedures for an efficient application of the equipments and getting the rapid analytical value about the investigation and sampling on the spot. And the accuracy of the portable equipments' analytical value is high but the application of them in an emergency is low because we are lack of the procedures about field-centered analysis and the usage. Therefore we would like to organize the result of this research about field analysis and the procedures of the solid portable equipments. And we also would like to apply it to the field of chemical terror accident.

Source Emission Rate on Air Pollutants from Portable Gas Range and Optimal Ventilation Rate in Indoor Environment (휴대용 가스렌지 연소에 의한 공기오염물질의 발생량 및 실내환경의 필요 환기량)

  • Yim, Sung-Kuk;Kim, Young-Hee;Yang, Won-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.2 s.95
    • /
    • pp.92-97
    • /
    • 2007
  • A series of source tests were conducted to characterize emissions of nitrogen oxide(NOx, NO, $NO_2$), carbon mon oxide(CO), carbon dioxide$(CO_2)$ and total VOCs from portable combustion devices in steady-state using well-mixed chamber. Since use of portable gas range is widespread in houses and restaurants in Korea, it is important to characterize the emission of air pollutants and suggest optimum ventilation rate. Ranges of emission rates of air pollutants from portable gas ranges were $NO \;0.551\sim0.939mg/hr,\;NO_2\;0.354\sim1.080mg/hr,\;NO_x\;1.207\sim1.631mg/hr,\;CO\;1.389\sim4.21mg/hr,\;CO_2\;2426.823\sim2973.495mg/hr$, and VOCs $0\sim0.119mg/h$. Mean of personal exposure and indoor environment level of $NO_2$ by combustion of portable gas range were 74.7 ppb and 65.4 ppb, respectively, suggesting persons using portable gas range in houses and restaurants might be highly exposed. Required ventilation rate to control the air pollutants emitted from portable gas range was maximumly $3.131m^3/hr$ on the basis of $NO_2$ indoor air quality standard.

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

Effects on Sight, Quickness, Balance, Pain of Normal Human Body with Using Portable Mobile Phone (스마트폰 사용이 정상인의 시력, 순발력, 균형능력, 통증에 미치는 영향)

  • Kang, Su-Jeong;Kim, Kyeong-Ha;Kim, Chi-Hyok
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.18 no.2
    • /
    • pp.95-102
    • /
    • 2012
  • Background: The purpose of this study was to find out influence of using portable mobile devices in human body. Method: The subjects were consisted of the normal persons (19 males and 20 females). These subjects were consisted of three groups according to test time. The A group (12 persons - 6 males, 6 females) tests 5 minutes, the B group (14 persons - 7 males, 7 females) tests 10 minutes, and the C group (13 persons - 6 males, 7 females) tests 15 minutes. Before test, sight, quickness and balance were measured, after test revision, quickness, balance were measured and checked pain scale. Results: The results were as follows. 1. Sight, quickness and balance were decreased and pains were increased after using portable mobile devices than before using these. 2. According to duration of using the portable mobile devices, sight, quickness and balance was not a statistically significant difference, the entire upper body pain was a statistically significant difference. When viewed as part of the pain, shoulder, lower back, and wrist pain were a statistically significant difference, but the neck and elbow were not a statistically significant difference. 3. The influence of vision according to distance of using Portable mobile devices was no statistically significant difference. In addition, less than 20cm distance using equipment group ("Ga") and the group ("Na") which exceeded 20cm in between the sight were not statistically significant difference, Influence of pain according to distance of using Portable mobile devices we-re no statistically significant differences. Conclusion: Using portable mobile devices affect human body on the elements of the biomechanics.

  • PDF

Correlation between the Portable X-ray and the Radiation Exposure dose in the Emergency Department: Cohort Study (응급실에서 이동식 단순 X-선 검사와 피폭선량과의 상관관계: 코호트 연구)

  • Kim, Yu Jung;Ahn, Hee Cheol;Sohn, You Dong;Ahn, Ji Yoon;Park, Seung Min;Lee, Won Woong;Lee, Young Hwan
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.11 no.2
    • /
    • pp.101-105
    • /
    • 2013
  • Purpose: This study was conducted in order to determine the relationship between the number of portable X-rays and the radiation exposure dose for emergency medical service providers working in the emergency department (ED). Methods: A prospective study was conducted from February 15, 2013 to May 15, 2013 in the ED in an urban hospital. Six residents, seven emergency medical technicians (EMT), and 24 nurses were enrolled. They wore a personal radiation dosimeter on their upper chest while working in the ED, and they stayed away from the portable X-ray unit at a distance of at least 1.8 m when the X-ray beam was generated. Results: The total number of portable x-rays was 2089. The average total radiation exposure dose of emergency medical service providers was $0.504{\pm}0.037$ mSv, and it was highest in the EMT group, 0.85(0.58-1.08) mSv. The average of the total number of portable X-rays was highest in the doctor group, 728.5(657.25-809). The relationship between the number of portable X-rays and the radiation exposure dose was not statistically significant(-0.186, p=0.269). Conclusion: Under the condition of staying away from the portable X-ray unit at a distance of least 1.8 m, the relationship between the number of portable X-rays and the radiation exposure dose was not statistically significant.

  • PDF

Analysis of Novel Magnetic-Spring Actuators for Portable Units (휴대장치용 새로운 자기 스프링 액추에이터의 해석)

  • 한인환
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1942-1949
    • /
    • 2004
  • SLA(Scanned Linear Array) is a portable display unit for implementing next-generation virtual realities, utilizes a design that light generated by a line of LEDs is reflected from the rapidly oscillating mirror to generate a raster display. Reaction forces generated by the motions of the mirror and counter-balance mass cancel each other at the device base, reducing vibration. Metal leaf springs have been extensively applied in such portable units. Magnetic springs have been developed and adopted that can replace the metal spring and can avoid many disadvantages of metal springs. We model and analyze the dynamics of the structure with magnetic springs and present the simulation and experimental analysis results, which can be utilized for identifying and eliminating possible problem sources in removing shaking forces and moments, and oscillating the mirror at the required amplitude and frequency. Finally, we present the improved novel magnetic actuator model which can be applied in portable display units.

A Verification Test on Safety Standards of Portable Propane Gas Stove for Safe Camping Culture (안전한 캠핑 문화의 정착을 위한 야외용 프로판 연소기 안전기준 실증 연구)

  • Ahn, Hyun-Soo;Choi, Suel-Ki;Lee, Chang-Eon;Kim, Young-Gu
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.293-294
    • /
    • 2014
  • In Korea, only butane gas could be used as fuel gas of the outdoor gas stove. However, butane is not vaporized well at low temperatures. For this reason, in the field, nozzle of the portable butane gas stove is converted illegally to use propane gas. Because vapor pressure of propane gas is higher than that of butane gas at same temperature, gas accidents such as gas leakage could be occurred. To prevent gas accidents and use portable propane gas stoves safely, international standards need to be analyzed and verification tests need to be performed with prototype stove. This study could suggest to revise standard for safety improvement with portable propane gas stoves.

  • PDF

Design of Portable E-Nose System using Neural Network Algorithm (신경회로망을 이용한 휴대용 E-Nose 시스템 개발)

  • Kim, Jeong-Do;Kim, Dong-Jin;Ham, Yu-Kyung;Hong, Cheol-Ho;Byun, Hyung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.39-42
    • /
    • 2004
  • We have designed a portable electronic nose(e-nose) system using an array of commercial gas sensors for recognition and analyzing the various odours. In this paper, we have implemented a portable e-nose system using an array gas sensors and personal digital assistants(PDA) for recognizing and analyzing volatile organic compounds(VOCs) in the field. Field screening for pollutants has been a target of instrumental development for number of year. A portable e-nose system can be substantial benefit to rapidly localize the spacial extent of a pollution or to find pollutants source. And, by using PDA, E-nose have a better function such as the easy user-interface and data transfer by internet from on- site to remote computer. We adapted the Levenberg-Marquardt algorithm based on the back-propagation and proposed the method that could be predicted concentration levels of VOCs gases after classification by separating neural network into two parts.

  • PDF

Development of Precise Measuring System for Hot Strip Mill's Rolls (열간압연용 롤 정밀 측정시스템 개발)

  • 이성진;이영진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.614-618
    • /
    • 2002
  • In hot strip mills, Portable Roll Scanner (the portable roll surface temperature and profile measuring device) can be used to calibrate on-line Process models for strip crown and flatness by measuring the thermal expansion and wear profile of the rolls. And the surface temperature measurement can be used to optimize the roll cooling system. Portable Roll Scanner consists of the measuring device, which has two contact inductive distance transducers for roll profile measurement and one infrared Pyrometer for surface temperature measurement, and computer-based controller that is equipped with the measuring device. By the wireless data communication, the data is transferred to the memory of notebook for further analysis. After roll extraction from mills, Portable Roll Scanner measure the roll profile and surface temperature simultaneously along the work roll face and display the results in the TFT color monitor of notebook. Portable Roll Scanner is useful at mill-side and roll grinding shop.

  • PDF