• Title/Summary/Keyword: porous concrete

Search Result 308, Processing Time 0.038 seconds

Mechanical Properties of Carbon Fiber Reinforced Porous Concrete for Planting

  • Park Seung-Bum;Kim Jeong-Hwan
    • KCI Concrete Journal
    • /
    • v.14 no.4
    • /
    • pp.161-169
    • /
    • 2002
  • The mechanical properties of fiber reinforced porous concrete for use as a planting material were investigated in this study. Changes in physical and mechanical properties, subsequent to the addition of carbon fiber and silica fume, were studied. The effects of recycled aggregate were also evaluated. The applicability as planting work concrete material was also assessed. The results showed that there were no remarkable changes in the void and strength characteristics following the increase in proportion of recycled aggregate. Also, the mixture with 10% silica fume was found to be the most effective for strength enforcement. The highest flexural strength was obtained when the carbon fiber was added with $3\%$. It was also noticed that PAN-derived carbon fiber was superior to Pitch-derived ones in view of strength. The evaluation of its usage for vegetation showed that the growth of plants was directly affected by the existence of covering soil, in case of having the similar size of aggregate and void.

  • PDF

Correlation Analysis between Unit Weight and Thermal Conductivity in Porous Concrete Containing Natural Fine and Bottom Ash Aggregates (바텀애시와 천연 잔골재를 혼입한 다공성 콘크리트의 단위질량과 열전도도의 상관분석)

  • Seung-Tae Jeong;In-Hwan Yang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.542-551
    • /
    • 2023
  • In this paper, the thermal properties of porous concrete containing natural fine aggregates in bottom ash aggregates were analyzed. In this study, natural fine aggregates were used for bottom ash aggregates to understand the material properties of each aggregate and then used as an aggregate for porous concrete. A porous concrete specimen was manufactured by fixing the water-binder ratio at 0.25 and designating the compaction at 0.5, 1.5, and 2.5 MPa. Unit weight, total void ratio and thermal conductivity test were measured and discussed. As the compaction increased and the mixing ratio of natural fine aggregates increased, the unit weight and thermal conductivity increased, and the total void ratio decreased. In addition, the correlations between unit weight, total void ratio and thermal conductivity of porous concrete with previous experimental data were presented and the correlation coefficient (R2) was also analyzed.

Influence of Paste Fluidity and Vibration Time for Fundamental Properties of Porous Concrete (시멘트체이스트의 유동성 및 진동다짐시간이 포러스콘크리트의 기초물성에 미치는 영향)

  • 이성일;유범재;장종호;김재환;백용관;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.311-316
    • /
    • 2001
  • This study analyzed the influence of paste fluidity and vibration time for fundamental properties of porous concrete. Results of this study were shown as follows; 1) Even if target void ratio is same, void ratio and compressive strength of porous concrete is different according to w/c, paste flow and vibration time. So, In case of target void ratio, we must consider the influence of w/c, paste flow, and vibration time. 2) Though w/c and vibration time are same, as paste flow increase, all void ratio, continuous void ratio, and compressive strength decrease and difference between upper and lower void ratio increase. 3) Though w/c and paste flow are same, as vibration time increase, all void ratio and continuous void ratio decrease and difference between upper and lower void ratio increase. Also, compressive strength increase by 10 seconds and decease after 10 seconds. 4) As types of superplasticizer is different, all void ratio, continuous void ratio, and compressive strength are different. So, we must give consideration to paste fluidity and vibration time in order that increase of strength of porous concrete and distribution of uniform void.

  • PDF

A Study on the Filed Application of Environmental Friendly Porous Concrete For Planting (환경친화 식생용 포러스콘크리트의 현장적용성에 관한 연구)

  • Kim Jeong Hwan;Lee Nam Ik;Lee Young Hee;Kwon Hyuk Jun;Lee Jun;Park Seung Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.769-772
    • /
    • 2005
  • The river environments of many streams in korea have been deteriorate through the rapid industrialization and urbanization since the 1960s. In Germany and Japan, on the other hand, much efforts on the research and project have been made for the restoration of the deteriorated streams to close-to-nature. in order to restore the deteriorated streams, therefore, it is necessary to investigate such advanced technologies and materials. In view of this requirement, various research paths are being taken focusing on coarse aggregates to make multi-functional porous concrete having continuous voids so as to improve water and air permeability, acoustic absorption, water purification, and applicability to vegetation. The Purpose of this study is to investigate the method for recovery of the environment in the streams area using porous concrete block. the porous concrete block applies for test in the cheonggae-cheon have been monitored planting during six month. after 6 months, plant grows flourishing and reconstructed in state such as nature rivers.

  • PDF

A Study on the pH Reduction of Cement Concrete with Various Mixing Conditions (시멘트 콘크리트의 배합조건에 따른 pH 저감에 관한 연구)

  • Jo, Young-Kug
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.4
    • /
    • pp.79-85
    • /
    • 2008
  • The purpose of this study is to evaluate the mix design of pH reducing cement concrete which can be used for environment-friendly concrete. Cement pastes and concretes are prepared with water-binder ratios and various admixtures such as blast-furnace slag, fly ash and recycled cement, and tested for compressive strength and pH. pH is measured through pore solution expressed from hydrated cement paste by special apparatus. From the test results, regardless of water-binder ratio, The pH of expressed pore solution from hydrated cement paste which is made of ordinary portland cement with blast-furnace slag, fly ash is decreased with increasing of admixtures content, and compressive strength is also slightly improved. The compressive strength of cement paste made of recycled cement which is burnt at $1000^{\circ}C$, for 2 hours is considerably increased compared with that of none-burnt recycled cement due to restoration of hydraulic property, but pH is a little higher. Porous concrete with ordinary portland cement has high pH in the range of 12.22 to 12.59, however, that is reduced to the range of 8.95 to 10.39 by carbonation at the surface of porous concrete. The pH reduction of porous concrete is possible by various admixture addition, however their degrees are very slight. Therefore, to reduce the pH considerably, carbonation method of porous concrete is better in pH reduction methods for plant survival condition of pH of 9.0 or less. In this study, it is apparent that pH for the environment-friendly porous concrete products used in the construction field can be suppressed by this carbonation method and various admixtures addition.

An Experimental Study on the Properties of Porous Concrete according to the Mix Factors and Compaction Load (배합조건 및 다짐하중에 따른 포러스 콘크리트의 특성에 관한 실험적 연구)

  • Lim, Seo-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.83-91
    • /
    • 2015
  • Porous concrete consists of cement, water and coarse aggregate and has been used for the purpose of decreasing the earth environmental load such as air and water permeability, sound absorption, etc. However, the physical and mechanical properties of porous concrete changes due to compaction load during construction. For such a reason, the purpose of this study is to investigate the physical and mechanical properties of porous concrete according to the kinds of binder, the ratio of water to binder and target void ratio. In particular, this study has been carried out to investigate the influence of compaction load on the void ratio, strength and coefficient of permeability. Aggregate used in this study are by-products generated during production of crushed gravel with a maximum size of 13mm. The results of this study showed that the target void ratio, the coefficient of permeability and compressive strength of porous concrete had a close relationship with the void ratio, and it will be possible that the void ratio is suggested by the mix design of porous concrete. The compressive strength of porous concrete was the highest at the content of the expansive admixture of 5% and compared to non-mixture, 10% mixture of silica fume improved compressive strength about 32%. And in the result of the study to change the compaction load, the compressive strength increased from the load of 15kN, the void ratio decreased from the load of 0.8kN, the coefficient of permeability decreased from the load 35kN, respectively.

An Evaluation of Resistances in Porous Asphalt Concrete Mixtures due to Repeated Cyclic Freeze-Thawing (배수성 아스팔트콘크리트 혼합물의 반복 동결융해 저항성 평가)

  • Jo, Shin Haeng;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1D
    • /
    • pp.33-39
    • /
    • 2012
  • More and more pavements are suffering from damage these days due to the below-zero winter temperatures and frequent snowfalls. From this research, the freeze-thawing mechanisms of pavements will be observed, and the freeze-thawing resistance of porous asphalt concrete mixture is to be evaluated according to various assessment methods. The investigation was conducted through applying rigid and flexible pavements to freeze-thawing resistance experiments, which include various experiments such as deformation rate measurements, Lottman tests, repeated cyclic freeze-thawing experiments, stripping resistance tests and so on. Test results revealed that the porous asphalt concrete had less deformations according to temperatures compared to dense-graded asphalt concrete due to the 20% void gap. In addition, according to the freeze-thawing repetition experiments which are effected by moisture, the porous asphalt concrete mixture showed superior resistance to repeated cyclic freeze-thawing compared to other asphalt concrete mixtures due to the drainage and the voids within the specimen.

Physical and Mechanical Properties of Non-Cement Porous Concrete with Alkali-Activator Contents (알칼리활성화제 치환율에 따른 무시멘트 다공성 콘크리트의 물리·역학적 특성)

  • Kim, Dong-Hyun;Kim, Chun-Soo;Park, Chan Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.2
    • /
    • pp.59-64
    • /
    • 2013
  • The present study is to evaluate physical and mechanical properties of porous concrete having non cement that mainly causes carbon emission. This study aims to explore eco-friendly concrete technology capable of reducing the amount of carbon emission due to the use of normal cement by substituting it with non cement porous concrete to which alkali-activator and blast-furnace slag powder are impregnated. As experimental variables, 5 %, 6 %, 7 %, 8 %, 9 % and 10 % of alkali-activator were substituted as binders and applied. Testing evaluated in this study were pH value, void ratio, compressive strength and residual compressive strength shown after being immersed in $H_2SO_4$ solution and $Na_2SO_4$ solution. The test results were compared with those tested with the use of porous concrete to which 400 $kg/m^3$ of unit cement amount was applied as binder. In consequence, it was concluded that; as for pH value, it was decreased than was the case in which cement was used, but increased with the more the use of alkali activator; as for void ratio and compressive strength, the mix proportion in which 9 % and 10 % of alkali activator were applied in terms of substitution ratio showed the result similar to the mixture in which 400 $kg/m^3$ of unit cement ratio was applied; and, as for residual compressive strength in the case of being immersed in $H_2SO_4$ solution and $Na_2SO_4$ solution, the compressive strength was increased, thus leading to improved chemical resistance.

Planting-Ability Valuation of Porous Concrete Using Industrial By-Products (산업부산물을 이용한 포러스콘크리트의 식생능력평가)

  • 박승범;이봉춘;김정환;윤덕열
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.623-629
    • /
    • 2002
  • Porous concrete enables water and air to pass through a firmly hardened material and allows required nutrients to reach roots of plants. The purpose of this study is to analyze void ratio, strength property and planting ability when using silica fume and fly ash, the change of aggregate gradation and ratio of paste to aggregate. The results of an experiment from the planting ability of the porous concrete to its influence on the compressive strength are reported in this paper. As a result of the experiment, the compressive strength is higher when the gradation of aggregate is smaller, and it also goes higher when the ratio of paste to aggregate gets larger. The planting ability of porous concrete is decided by the germination and the grass length of perennial ryegrass. The grass length of perennial ryegrass is longer when the gradation of aggregate is greater and the ratio of paste to aggregate gets smaller. Therefore the efficiency of planting goes through the perennial ryegrass is in compliance with the void ratio, aggregate gradation.