• 제목/요약/키워드: pool boiling

검색결과 224건 처리시간 0.026초

응축 풀 내의 비정상 층류 제트의 유동 특성에 관한 연구 (A Study of the Characteristics of Unsteady Laminar Jet Submerged into a Suppression Pool)

  • 최용문;김종보
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.499-507
    • /
    • 1988
  • The pressure suppression pool of BWR(Boiling Water Reactor) is subjected to hydrodynamic impact in the event of a LOCA(Loss of Coolant Accident). The pressure increase in the reactor dry cell would force the existing water of a vent pipe into the suppression pool. When the water is ejected through the pipe opening into the suppression pool, an abrupt downward force is transmitted to the suppression pool floor. Consequently, many structures installed within the pool must be able to withstand these forces. In order to determine the optimum safe locations of the pool structures, numerical analysis have been carried out to investigate the hydrodynamic behavior of the water jet. In the present analysis, a two-dimensional numerical model is utilized to solve transient flow equations.

  • PDF

수평 가까운 튜브 표면의 평균 풀비등 열전달계수의 측정 (Measurement of Average Pool Boiling Heat Transfer Coefficient on Near-Horizontal Tube)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제38권1호
    • /
    • pp.81-88
    • /
    • 2014
  • 수평에 가깝게 설치된 튜브 원주면에 대해 평균 열전달계수를 결정하기 위한 실험적 연구를 수행하였다. 실험을 위하여 대기압 상태하의 물속에 잠긴 50.8 mm의 스테인리스강 튜브를 사용하였다. 과냉 및 포화 풀비등 조건을 모두 고려하였으며, 튜브 경사각은 수평으로부터 $9^{\circ}$까지 $3^{\circ}$ 간격으로 변경하였다. 포화상태에서는 튜브의 최하부로부터의 방위각이 $90^{\circ}$인 위치에서 측정한 국소비등열전달계수가 평균값으로 취급될 수 있으며, 이러한 경향은 튜브 경사각과는 무관함을 확인하였다. 그러나 물이 과냉상태인 경우, 평균 열전달계수의 위치는 경사각과 열유속에 의존한다. 열전달을 변화시키는 주된 열전달 기구는 액체교란 강도 및 기포군집에 의한 큰 기포 덩어리의 형성과 밀접한 관계가 있는 것으로 설명된다.

흡수식 냉동기 재생기용 고성능 전열관의 풀비등 성능 (Pool Boiling Performance of Enhanced Tubes for the Generator of an Absorption Chiller)

  • 심용섭;김내현
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.1684-1691
    • /
    • 2015
  • 흡수식 냉동기의 고효율화와 소형화를 위해서는 고성능 전열관의 연구가 필수적이다. 하지만 재생기용 전열관에 대한 연구는 많이 미흡한 실정이다. 본 연구에서는 만액식 재생기용 전열관의 성능을 파악하기 위한 기초연구로, 형상이 다른 7종의 전열관에 대해 풀비등 실험을 수행하고 비등열전달계수를 도출하였다. 실험은 압력 7.38~101.3 kPa, 열유속 $20{\sim}40kW/m^2$의 범위에서 수행되었다. 실험결과 모든 전열관에서 압력이 증가하고 열유속이 증가할수록 비등열전달계수 값은 증가하였다. 대기압 조건에서는 notched fin 관과 low fin 관이 높은 비등열전달계수를 나타내었고(열전달계수가 가장 낮은 19.0 mm O.D. 평활관의 225% 와 202%), 압력이 낮아질수록 low fin 관이 다른 전열관에 비해 현저히 높은 비등열전달계수를 나타내었다 (12.34와 7.38 kPa에서 19.0 mm O.D. 평활관의 290%와 288%).

냉매 이성분 혼합물의 포화 풀핵비등 특성에 관한 연구 (Study on the characteristics During Saturated Pool Nucleate Boiling of Refrigennt Binary Mixtures)

  • 김정배;이한춘;김무환
    • 대한기계학회논문집B
    • /
    • 제29권5호
    • /
    • pp.643-652
    • /
    • 2005
  • Saturated nucleate pool boiling experiments for binary mixtures, which are consisted of refrigerant R11 and R113, were performed with constant wall temperature condition. Results for binary mixtures were also compared with pure fluids. A microscale heater array and Wheatstone bridge circuits were used to maintain the constant temperature of the heating surface and to obtain heat flow rate measurements with high temporal and spatial resolutions. Bubble growth images were captured using a high speed CCD camera synchronized with the heat flow rate measurements. The departure time for binary mixtures was longer than that for pure fluids, and binary mixtures had a higher onset of nucleate boiling (ONB) temperature than pure fluids. In the asymptotic growth region, the bubble growth rate was proportional to a value between $t^{\frac{1}{6}}$ and $t^{\frac{1}{4}}$. The bubble growth behavior was analyzed to permit comparisons with binary mixtures and pure fluids at the same scale using dimensionless parameters. There was no discernable difference in the bubble growth behavior between binary mixtures and pure fluids for a given ONB temperature. And the departure radius and time were well predicted within a ${\pm}30{\%}$ error. The minimum heat transfer coefficient of binary mixtures occurred near the maximum ${\mid}y-x{\mid}$ value, and the average required heat flux during bubble growth did not depend on the mass fraction of R11 as more volatile component in binary mixtures. Finally, the results showed that for binary mixtures, a higher ONB temperature had the greatest effect on reducing the heat transfer coefficient.

개질된 표면을 이용한 풀비등 임계열유속 증진에 관련한 실험적 연구 (Experimental Investigation of CHF Enhancement on the Modified Surface Under Pool Boiling)

  • 강순호;안호선;조항진;김무환;김형모;김준원
    • 대한기계학회논문집B
    • /
    • 제33권11호
    • /
    • pp.840-848
    • /
    • 2009
  • In the boiling heat transfer mechanism, CHF(critical heat flux) is the significantly important parameter of the system. So, many researchers have been struggling to enhance the CHF of the system in enormous methods. Recently, there were lots of researches about enormous CHF enhancement with the nanofluids. In that, the pool boiling CHF in nanofluids has the significantly increased value compared to that in pure water because of the deposition of the nanoparticle on the heater surface in the nanofluids. The aim of this study is the comparison of the effect of the nanoparticle deposited surface and the modified surface which has the similar morphology and made by MEMS fabrication. The nanoparticle deposited surface has the complex structures in nano-micro scale. Therefore, we fabricated the surfaces which has the similar wettability and coated with the micro size post and nano structure. The experiment is performed in 3 cases : the bare surface with 0.002% water-ZnO nanofluids, the nanoparticle deposited surface with pure water and the new fabricated surface with pure water. The contact angle, a representative parameter of the wettability, of the all 3 cases has the similar value about 0 and the SEM(scanning electron microscope) images of the surfaces show the complex nano-micro structure. From the pool boiling experiment of the each case, the nanoparticle deposited surface with pure water and the fabricated surface with pure water has the almost same CHF value. In other words, the CHF enhancement of the nanoparticle deposited surface is the surface effect. It also shows that the new fabricated surface follows the nanoparticle deposited surface well.

낮은 핀 표면과 Turbo-B 촉진 표면에서 임계 열유속까지의 풀 비등 열전달계수 (Pool Boiling Heat Transfer Coefficients Up to Critical Heat flux on Low-fin and Turbo-B Surfaces)

  • 이요한;정동수
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.179-187
    • /
    • 2011
  • In this work, nucleate pool boiling heat transfer coefficients(HTCs) of 5 refrigerants of differing vapor pressure are measured on horizontal low fin and Turbo-B square surfaces of 9.53 mm length. Tested refrigerants are R32, R22, R134a, R152a and R245fa and HTCs are taken from 10 $kW/m^2$ to critical heat fluxes for all refrigerant at $7^{\circ}C$. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and in the liquid pool. Test results show that Critical heat fluxes(CHFs) of all enhanced surfaces are greatly improved as compared to that of a plain surface in all tested refrigerants. CHFs of all refrigerants on the 26 fpi low fin surface are increased up to 240% as compared to that of the plain surface. HTCs on both low fin and Turbo-B surfaces increase with heat flux. After certain heat flux, however, they decrease. CHFs of the Turbo-B enhanced surface are lower than that of the 26 fpi low fin surface. This phenomenon is due to the difference in surface structure of the low fin and Turbo-B surface.

Thermoexcel-E 촉진 표면에서 임계 열유속까지의 풀 비등 열전달계수 (Pool Boiling Heat Transfer Coefficients Up to Critical Heat flux on Thermoexcel-E Enhanced Surface)

  • 이요한;강동규;장철한;정동수
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.685-692
    • /
    • 2012
  • In this work, nucleate pool boiling heat transfer coefficients(HTCs) of 5 refrigerants of different vapor pressure are measured on horizontal Thermoexcel-E square surface of 9.53 mm length. Tested refrigerants are R32, R22, R134a, R152a and R245fa. HTCs are taken from 10 $kW/m^2$ to critical heat fluxes for all refrigerant at $7^{\circ}C$. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and in the liquid pool. Test results show that critical heat fluxes(CHFs) of Thermoexcel-E enhanced surface are greatly improved as compared to that of a plain surface in all tested refrigerants. CHFs of all refrigerants on the Thermoexcel-E surface are increased up to 100% as compared to that of the plain surface. The improvement of Thermoexcel-E surface in CHF, however, is lower than that of the low fin surface. HTCs on Thermoexcel-E surface increase with heat flux. But after certain heat flux, HTCs began to decrease due to the difficulty in bubble removal caused by the inherent complex nature of this surface. Therefore, at heat fluxes close to the critical one, sudden decrease in HTCs needs to be considered in thermal design with Thermoexcel-E surface.

충돌수분류의 천이 및 막비등열전달에 관한 연구 (An Experimental Study on Transition and Film Boiling Heat Transfer of Impinging Water Jet)

  • 엄기찬;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제14권2호
    • /
    • pp.87-97
    • /
    • 1985
  • Experimental measurements of the heat flux to a upward impinging water jet on high heated test surface were obtained in the transition and film boiling regimes. Test variables were nozzle outlet velocity, subcooled water temperature and height of supplementary water. Boiling curve of this investigation is similar to a pool boiling curve, but it has one or two cap-shaped peaks in the transition regime. In the film boiling regime, the heat transfer rates are increased along with the increment of nozzle outlet velocity and subcooled temperature. There is optimum height of supplementary water for the augmentation of heat transfer Generalized correlations of boiling heat transfer are presented for maximum heat flux, minimum heat flux and $q_c$ at each supplementary height.

  • PDF