• Title/Summary/Keyword: polytetrafluoroethylene(PTFE)

Search Result 189, Processing Time 0.038 seconds

Dielectric Characteristics of Polytetrafluoroethylene-based Composites for Microwave Substrates with Formation Pressure (고주파 기판용 PTFE 복합체 형성 압력에 따른 유전 특성)

  • Choi, Hong Je;Chun, Myung Pyo;Cho, Yong Soo;Cho, Hak Rae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.6
    • /
    • pp.429-433
    • /
    • 2013
  • PTFE composites for use of microwave substrate were fabricated by impregnation and heat treatment fabrication with glass fabric. This study shows dielectric properties such as dielectric constant and loss can be controlled by thickness of PTFE composite with change of pressure condition in heating press process. The dielectric constant of the PTFE composites has decreasing tendency as given higher pressure condition. The dielectric loss has similar result too. Especially, the case of the dielectric loss was affected by the condition of pressure at heating press and had the best performance under 3 MPa. In order to see the reason why thickness conditions make different, their microstructures were also observed.

Measurement of Absorbed Dose for High Energy Electron using $CaSO_4:Tm$ - PTFE TLD (고에너지 전자선의 흡수선량 측정에 있어서 TLD의 유용성)

  • Park, Myeong-Hwan;Kim, Do-Sung
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.97-101
    • /
    • 2000
  • In this study, the highly sensitive $CaSO_4:Tm$-PTFE TLDs has been fabricated for the purpose of measurement of high energy electron. $CaSO_4:Tm$ phosphor powder was mixed with polytetrafluoroethylene(PTFE) powder and moulded in a disk type(diameter 8.5 mm. thickness $90\;mg/cm^2$) by cold pressing. The absorbed dose distribution and ranges for high energy electron were measured by using the $CaSO_4:Tm$-PTFE TLDs. The ranges determined were $R_{100}=14.5mm$, $R_{50}=24.1mm$ and $R_P=31.8mm$, respectively and the beam flatness, the variation of relative dose in 80% of the field size, was 4.5%. The fabricated $CaSO_4:Tm$-PTFE TLDs nay be utilized in radiation dosimetry for personal, absorbed dose and environmental monitoring.

  • PDF

Systemic-Pulmonary Shunts Using Microporous Expanded Polytetrafluoroethylene (Polytetrafluoroethylene 을 이용한 체-폐동맥 단락술)

  • Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.314-319
    • /
    • 1985
  • Nineteen patients with various types of cyanotic congenital heart disease underwent systemic-pulmonary artery shunts with a microporous polytetrafluoroethylene [PTFE] graft between September, 1983, and April, 1985. Age ranged from 3 months to 18 years, and seven of them were less than 12 months old. There were seventeen Great Ormond Street type of modified Blalock-Taussig shunts, and two central polytetrafluoroethylene shunt [ascending aorta-right pulmonary artery]. There was one postoperative death [1/19=5.3%] in a 10 Kg child born with pulmonary atresia and ventricular septal defect associated with patent ductus arteriosus. He had another anomaly of imperforated anus. Relief from cyanosis was achieved in other eighteen patients with variable degree. Eighteen survivors have been followed up from 1 month to 19 months. Clinical status, auscultation, oxygen partial pressure of arterial blood, and hemoglobin have been used to establish shunt patency in all survivors. By above criteria, all survivors have good patent shunt.

  • PDF

An Investigation of the Enhancement of Abrasive Ability of Diamond Film by Surface Modification (다이아몬드 박막의 표면 개질을 통한 연마성능 향상에 대한 실험적 고찰)

  • 나종주;이구현;남기석;이상로;백영준
    • Tribology and Lubricants
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • In order to identify the effect of lubricant films on abrasive abilities of diamond films, wear rates of Ruby balls slid over as grown diamond films and polytetrafluoroethylene films coated diamond films were compared by using pin-on-disk tribometer. Wear scars of Ruby balls were measured by SEM. Results showed that wear rates of Ruby balls slid over polytetrafluoroethylene coated diamond films were about 4 times lager than as grown diamond films. Coefficients of friction decreased with sliding distance at diamond disks but were almost unchanged at polytetrafluoroethylene coated ones. These results came from behaviors of wear debris, which adhered more strongly in the tracks of as grown diamond films than polytetrafluoroethylene coated ones.

Emulsion Electrospinning of Hydrophobic PTFE-PEO Composite Nanofibrous Membranes for Simple Oil/Water Separation

  • Son, Seo Ju;Hong, Seong Kyung;Lim, Geunbae
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.89-92
    • /
    • 2020
  • Polytetrafluoroethylene (PTFE) fibers are widely used in the textile industry, filter media, membrane distillation, electronic appliances, and construction. In this study, PTFE-polyethylene oxide (PEO) fibrous membranes were fabricated by emulsion electrospinning; subsequently, pure PTFE nanofibers were obtained via sintering. PTFE-PEO electrospinning solutions were prepared using different weight ratios to determine the optimized condition. As the ratio of the PEO increased, the fiber structure improved. Scanning electron microscopy and Fourier-transform infrared spectroscopy observations indicate that PEO is removed and PTFE fused gradually to form bonds among them during sintering. The obtained pristine PTFE membrane demonstrated hydrophobicity at 143.6° water contact angle and oleophilicity at 0° oil contact angle, which is known to be utilized for oil/water separation. A simple separation experiment was performed to remove oil droplets from water. The PTFE membrane exhibited good chemical stability and a high surface-area-to-volume nanofiber ratio. These excellent properties suggest that it is applicable to oil/water separation in harsh chemical environments.

Preparation of Ni-PTFE Electrode using Nickel Plating for Alkaline Fuel Cell (니켈도금기술을 이용만 알칼리형 연료전지용 Ni-PTFE전극의 개발)

  • Kim, Jae-Ho;Lee, Young-Seak
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.4
    • /
    • pp.291-299
    • /
    • 2009
  • Ni-plated polytetrafluoroethylene(Ni-PTFE) particles($25{\mu}m$, $500{\mu}m$) were prepared by using nickel electroless plating. The Ni content in Ni-PTFE particles increased with increasing the amount of reduction agent. At about 53 wt% Ni content, $25{\mu}m$ Ni-PTFE particles showed conductivity of 320S/m. The Ni-PTFE particles were formed into the Ni-PTFE plate using heat treatment at $350^{\circ}C$ under $10{\sim}1000kg/cm^2$. The Ni-PTFE plate displayed the high conductivity of 5100S/m due to the formation of 3-dimentional Ni network. The plate was used as an electrode in an alkaline fuel cell(AFC). In terms of the current density, the Ni-PTFE electrode having higher Ni content(53 wt%) showed improved performance.

Effect of Binders on Electrochemical and Mechanical Properties of Activated Carbon Electrode for Electric Double Layer Capacitor (EDLC용 활성탄소 전극의 전기화학적 기계적 특성에 미치는 바인더의 영향)

  • Jeon, Min-Je;Kim, Ick-Jun;Yang, Sun-Hye;Moon, Seong-In;Kim, Hyun-Soo;Oh, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1167-1171
    • /
    • 2006
  • This work describes the effect of binders, such as carboxymethylcellulose (CMC), CMC+ Polytetrafluoroethylene (PTFE) and PTFE, on the electrochemical and mechanical properties of activated carbon-electrode for electric double layer capacitor. The cell capacitors using the electrode bound with binary binder composed of CMC and PTFE, especially in composition CMC PTFE = 60 : 40 wt.%, has better rate capability and the lower internal resistance than those of the cell capacitor with CMC. On the other hand, the sheet type electrode kneaded with PTFE was bonded with conductive adhesive on Al foil. This cell capacitor using the electrode with PTFE exhibited the best mechanical properties and rate capability compared to the CMC and CMC+PTFE one. These behaviors could be explained by the well-developed network structure of PTFE fibrils doting the kneading process.

Paclitaxel Coating Inhibits Inflammation Surrounding Subcutaneously Implanted Expanded Polytetrafluoroethylene (ePTFE) Hemodialysis Grafts in Rabbit Model

  • Baek, In-Su;Lee, Yu-Ji;Park, Soo-Jin;Bai, Cheng Zhe;Park, Jong-Sang;Kim, Dae-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.281-285
    • /
    • 2010
  • Hemodialysis vascular access dysfunction (HVAD) due to the aggressive development of venous neointimal hyperplasia remains a major complication for patients with synthetic arteriovenous grafts. Paclitaxel-coated expanded polytetrafluoroethylene (ePTFE) grafts effectively prevent neointimal hyperplasia and stenosis. However, perigraft inflammation or edema can be another complication of ePTFE grafts, preventing early cannulation. Three different types of ePTFE grafts, including grafts without paclitaxel coating (control group, n = 12), grafts with paclitaxel coating at a dose density of $0.61ug/mm^2$ (low concentration group, n = 12), and grafts with paclitaxel coating at a dose density of $1.15ug/mm^2$ (high concentration group, n = 12) were placed in the backs of 12 rabbits, simultaneously. Six rabbits were euthanized after one week and the remaining six were euthanized two weeks after implantation. Perigraft inflammation, graft wall inflammation, stromal cell proliferation, blood vessel formation, tissue necrosis and edema were analyzed for the grafts in each animal. Inflammation surrounding the paclitaxel-coated grafts was significantly reduced compared to the control group. Stromal cell layers were detected at the interface between the graft and the surrounding tissue in the control group, infiltrated into the graft interstices, and differentiated into myofibroblasts for graft healing. Paclitaxel-coated grafts inhibited stromal cell proliferation and infiltration into the graft wall. Tissue necrosis and edema were not detected in either of the paclitaxel-coated graft groups.

Changes in the Luminal Surface of the PTFE Graft used in Systemic- pulmonary Shunt Operation (체폐단락술에 사용되었던 PTFE 인조혈관 내면의 변화)

  • Park, Yeong-Hwan;Jang, Byeong-Cheol;Sin, Dong-Hwan;Jo, Beom-Gu
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.836-843
    • /
    • 1996
  • Histologic, and scanning electron microscopic observa ions were made of 12 biopsy specimens from polytetrdiluoroethylene (PTFE) grafts that had been Implanted as systemic-pulmonAry shunt for improving oxygenation of cyanotic congenital heart disease and harvested near the end of pulmonary artery side at the time of redo shunt or tonal correction between 1985 and 1992. The types of shunt operation are modified Blalock-Taussig shunt in 10 cases, Waterston-Cooley shunt in 1 And Potts shunt in 1 case. The 5 mm PTFE graft was used In 10, 4mm in 1 and 6mm in 1 case. The mean duration of implantalion was 0 $\pm$ 14.1 months(rl.on 12 months to 55 months). The plAtelets were aggregated between gaps'of Coretex surface and intimal thickening was noted about 10 to 20 months after implantation. Endothelial cells were found in the 40-months patent PTFE graft by light and scanning electron microscopy. In the specimen of poor flow or zero flow graft, severe intimal hyperplasia and thrombi which was made of platelets were noted . Based on this experience, we think that the patency will be maintained well if the connective tissue could be Hxed firmly over the Inner layer of the Goretex and the endothelial cell layer sllould form over the con- nective tissue and platelet aggregation should be prevented.

  • PDF