• 제목/요약/키워드: polytetrafluoroethylene(PTFE)

검색결과 192건 처리시간 0.023초

3D 프린팅을 이용한 Pt/Carbon Nanotube composite 기반 전기화학식 황화수소 가스 센서 제작 (Fabrication of Pt/Carbon Nanotube Composite Based Electrochemical Hydrogen Sulfide Gas Sensor using 3D Printing)

  • 하윤태;권진범;최수지;정대웅
    • 센서학회지
    • /
    • 제32권5호
    • /
    • pp.290-294
    • /
    • 2023
  • Among various types of harmful gases, hydrogen sulfide is a strong toxic gas that is mainly generated during spillage and wastewater treatment at industrial sites. Hydrogen sulfide can irritate the conjunctiva even at low concentrations of less than 10 ppm, cause coughing, paralysis of smell and respiratory failure at a concentration of 100 ppm, and coma and permanent brain loss at concentrations above 1000 ppm. Therefore, rapid detection of hydrogen sulfide among harmful gases is extremely important for our safety, health, and comfortable living environment. Most hydrogen sulfide gas sensors that have been reported are electrical resistive metal oxide-based semiconductor gas sensors that are easy to manufacture and mass-produce and have the advantage of high sensitivity; however, they have low gas selectivity. In contrast, the electrochemical sensor measures the concentration of hydrogen sulfide using an electrochemical reaction between hydrogen sulfide, an electrode, and an electrolyte. Electrochemical sensors have various advantages, including sensitivity, selectivity, fast response time, and the ability to measure room temperature. However, most electrochemical hydrogen sulfide gas sensors depend on imports. Although domestic technologies and products exist, more research is required on their long-term stability and reliability. Therefore, this study includes the processes from electrode material synthesis to sensor fabrication and characteristic evaluation, and introduces the sensor structure design and material selection to improve the sensitivity and selectivity of the sensor. A sensor case was fabricated using a 3D printer, and an Ag reference electrode, and a Pt counter electrode were deposited and applied to a Polytetrafluoroethylene (PTFE) filter using PVD. The working electrode was also deposited on a PTFE filter using vacuum filtration, and an electrochemical hydrogen sulfide gas sensor capable of measuring concentrations as low as 0.6 ppm was developed.

점액종에 의한 우심실 유출로 협착 (Right Ventricular Myxoma Obstructing Right Ventricular Outflow Tract)

  • 송광재;윤태진
    • Journal of Chest Surgery
    • /
    • 제39권8호
    • /
    • pp.637-639
    • /
    • 2006
  • 심장 내 점액종은 심장에 발생하는 원발성 종양 중 가장 흔하지만, 우심실 유출로 협착을 유발하는 점액종은 비교적 드물다. 15세 여자 환자가 운동 시 호흡 곤란 및 간헐적인 의식 소실을 주소로 내원하였고, 심초음파상 우심실 유출로를 거의 폐쇄하는 $3.6{\times}3.0\;cm$ 크기의 종괴가 발견되어 응급수술이 시행되었다. 우심실 종괴가 폐동맥 직하 부위의 우심실 전벽으로부터 기시하고 있음을 확인하고, 종괴 기시 부위 주위의 우심실 전벽을 광범위하게 절제하면서 종괴를 제거하였고 우심실 전벽의 결손은 Gore-Tex 포편 봉합하였다. 병리학적 검사상 우심실에 발생한 점액종으로 진단되었으며, 환자는 특별한 문제없이 술 후 7일째 퇴원하였다.

Dielectric Properties of Ceramic/Polymer Composites at Microwave Frequencies

  • 김응수;전창준
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.19.1-19.1
    • /
    • 2011
  • Effects of particle size, crystal structures and multilayer structures of $ATiO_3$, $ATa_2O_6$, $ANb_2O_6$, $AWO_4$, and $AMoO_4$ (A=Ni, Mg, Zn, Co) ceramic fillers on the dielectric properties of polystyrene (PS), polypropylene (PP) and polytetrafluoroethylene (PTFE) polymer matrices were investigated at microwave frequencies. The microwave dielectric properties of $ATiO_3$ (ilmenite), $ATa_2O_6$ (tri-rutile), $ANb_2O_6$ (columbite), AWO4 (wolframite), and AMoO4 (wolframite) ceramics were largely dependent on the structural characteristics of oxygen octahedra. The dielectric constant (K) of the composites was increased with the ceramic content. However, the dielectric loss (tan ${\delta}$) of the composites was affected by the type of ceramics and the crystallinity of polymers. For the composites with same amount of ceramics, the K was decreased and the tan ${\delta}$ was increased with the particle size of ceramics. Also, the dielectric properties of the composites were dependent on the multilayer structures with different arrangements. Several theoretical models have been employed to predict the effective dielectric properties of the composites. The frequency dependence of dielectric properties and the temperature coefficient of resonant frequency (TCF) of the composites were also discussed.

  • PDF

소수성 Needle을 이용한 미세 유기 박막 Stripe 제작 (Fabrication of Fine Organic Thin-Film Stripes Using a Hydrophobic Needle)

  • 김종명;이진영;신동균;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제19권1호
    • /
    • pp.73-78
    • /
    • 2020
  • There appears lateral capillary force in a hydrophilic flat needle employed for the fabrication of fine organic thin-film stripes, bringing in an increase of the stripe width. It also causes the stripe thickness to increase with increasing coating speed, which is hardly observed in a normal coating process. Through computational fluid dynamics (CFD) simulations, we demonstrate that the lateral capillary flow can be substantially suppressed by increasing the contact angle of the needle end. Based on the simulation results, we have coated the outer surface of the flat needle with a hydrophobic material (polytetrafluoroethylene (PTFE) with the water contact angle of 104°). Using such a hydrophobic needle, we can suppress the lateral capillary flow of an aqueous poly(3,4-ethylenedioxythiophene): poly(4-styrenesulfonate) (PEDOT:PSS) to a great extent, rendering the stripe narrow (63 ㎛ at 30 mm/s). Consequently, the stripe thickness is decreased as the coating speed increases. To demonstrate its applicability to solution-processable organic light-emitting diodes (OLEDs), we have also fabricated OLED with the fine PEDOT: PSS stripe and observed the strong light-emitting stripe with the width of about 68 ㎛.

Electrical characteristics of insulating materials for HTS bushing immersed in $LN_2$

  • Choi, J.H.;Kim, W.J.;Shin, H.S.;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권4호
    • /
    • pp.10-13
    • /
    • 2011
  • For the operation of high temperature superconducting (HTS) power equipments, it is necessary to develop insulating materials and high voltage (HV) insulation technology at cryogenic temperature of bushing. In this paper, the surface flashover characteristics of various insulating materials in $LN_2$ are studied. These results are studied at both AC and impulse voltage under a non-uniform field. The negative impulse breakdown voltage of GFRP is slightly higher than the positive impulse breakdown voltage. The use of glass fiber reinforced plastic (GFRP) and polytetrafluoroethylene (PTFE, Teflon) as insulation body for HTS bushing should be much desirable. Especially, GFRP is excellent material not only surface flashover characteristics but also mechanical characteristics at cryogenic temperature. The surface flashover is most serious problem for the shed design in $LN_2$ and operation of superconducting equipment.

Performances of Plastic Pulley with High Mechanical Properties and Low Friction

  • Kim, Namil;Lee, Jung-Seok;Hwang, Byung-Kook;Bae, Seokhu;Yoon, Jeong-Hwan;Yun, Juho
    • Elastomers and Composites
    • /
    • 제54권2호
    • /
    • pp.135-141
    • /
    • 2019
  • Polyphenylene sulfide (PPS) was filled with glass fiber (GF), aramid fiber (AF), and solid lubricants to improve the mechanical properties and wear resistance. The addition of GF effectively enhanced the tensile strength, flexural modulus, and impact strength of PPS, while solid lubricants such as polytetrafluoroethylene (PTFE), molybdenum disulfide ($MoS_2$), and tungsten disulfide ($WS_2$) lowered the friction coefficients of the composites to below 0.3. The ball nut and motor pulley of the electric power steering (EPS) were manufactured using the PPS composites, and feasibility was ascertained thereafter by conducting the durability test. The composites filled with GF and AF showed high mechanical strength, but slip occurred at the interface between the pulley and belt while testing above $50^{\circ}C$. When small amounts of lubricants were added, the slip was no longer detected because of the suppression of friction heat. It is realized that the low friction as well as high mechanical properties is important to ensure the reliability of plastic pulleys.

Percutaneous Transhepatic Treatment of Benign Bile Duct Strictures Using Retrievable Covered Stents: Long-Term Outcomes in 148 Patients

  • Byung Soo Im;Dong Il Gwon;Hee Ho Chu;Jin Hyoung Kim;Gi-Young Ko;Hyun-Ki Yoon
    • Korean Journal of Radiology
    • /
    • 제23권9호
    • /
    • pp.889-900
    • /
    • 2022
  • Objective: To investigate the long-term outcomes of percutaneous treatment of benign biliary strictures using temporary placement of a retrievable expanded polytetrafluoroethylene (PTFE) covered stent. Materials and Methods: We retrospectively analyzed the outcomes of 148 patients (84 male and 64 female; age range, 11-92 years) who underwent percutaneous transhepatic placement and removal of a retrievable PTFE-covered stent for the treatment of benign biliary strictures between March 2007 and August 2019 through long-term follow-up. Ninety-two patients had treatment-naïve strictures and 56 had recurrent/refractory strictures. Results: Stent placement was technically successful in all 148 patients. The mean indwelling period of the stent was 2.4 months (median period, 2.3 months; range, 0.2-7.7 months). Stent migration, either early or late, occurred in 28 (18.9%) patients. Clinical success, defined as resolution of stricture after completing stent placement and removal, was achieved in 94.2% (131 of 139 patients). The overall complication rate was 15.5% (23 of 148 patients). During the mean follow-up of 60.2 months (median period, 52.7 months; range, 1.6-146.1 months), 37 patients had a recurrence of clinically significant strictures at 0.5-124.5 months after removal of biliary stent and catheter (median, 16.1 months). The primary patency rates at 1, 3, 5, 7, and 10 years after removal of biliary stent and catheter were 88.2%, 70.0%, 66.2%, 60.5%, and 54.5%, respectively. In the multivariable Cox proportional hazard regression analysis, sex, age, underlying disease, relation to surgery, stricture type, biliary stones, history of previous treatment, and stricture site were not significantly associated with the primary patency. Conclusion: Long-term outcomes suggest that percutaneous treatment of benign biliary strictures using temporary placement of retrievable PTFE-covered stents may be a clinically effective method.

하천수에서 LC-ESI-MS/MS에 의한 극미량 농약류 및 합성원료의 동시분석법 (Simultaneous Determination of Ultra-Trace Pesticides and Synthetic Materials in Surface Water by LC-ESI-MS/MS)

  • 홍선화;이준배;이수형;조영환;신호상
    • 대한화학회지
    • /
    • 제59권3호
    • /
    • pp.225-232
    • /
    • 2015
  • 하천수 중에 7가지의 농약류(2,4-dichlorophenoxyacetic acid, 메소밀, 알디캅, MCPA, molinate, 카바릴, 카보퓨란)와 2가지의 합성원료(quinoline, 비스페놀-A)를 액체크로마토그래피 전자분무 이온화 질량분석법(liquid chromatography-electrospray ionization-tandem mass spectrometry, LC-ESI-MS/MS)을 사용하여 분석하였다. 분석물질들은 고체상 추출법(solid-phase extraction, SPE)을 사용하여 추출하였다. 용리액은 질소가스로 농축하였다. 잔여물에 30% 메탄올 수용액 100 μL를 재 용해시켜 0.2 μm PTFE 실린지 필터로 거른 후 그 일부를 LC-ESI-MS/MS에 직접 주입하여 분석하였다. 확립된 조건에서 검정곡선은 0.997 이상의 상관계수를 갖는 직선성을 보였다. 정량한계는 0.002~0.011 μg/L 이었고, 정밀도는 16.4% 이하였다. 또한 정확도는 84~107%의 범위를 보였고, 회수율은 56.2~98.6% 값을 나타내었다. 본 연구에서 개발한 분석법을 실제 하천수 분석에 적용하였다.

피질골 골결손부에서 Oxidized Cellulose 피개의 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE EFFECTS OF OXIDIZED CELLULOSE COVERAGE ON THE CORTICAL BONY DEFECTS)

  • 김회종;임재석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제20권2호
    • /
    • pp.112-126
    • /
    • 1998
  • In dentistry, bony defects can be formed by cyst, tumor, inflammation, trauma and surgery in maxilla and mandible. If the overlying soft tissue invades and preoccupies the jaw bony defects, regenerated bony tissue same as adjacent bone can not replace whole space of the defects, thus preventing osteogenesis from occurring. Guided bone regeneration(GBR) is based on the prevention of overlying soft tissue from entering the bony defect during the initial healing periods. E-polytetrafluoroethylene(e-PTFE) is one of an effective and widely used barrier membrane for GBR, but it has the disadvantages such as surgical removal and high price. To overcome such disadvantages of e-PTFE, many investigators have proposed various absorbable barrier membranes. Inexpensive oxidized cellulose($Surgicel^{(R)}$) membrane was shown to have potential for use as an absorbable barrier membrane for regenerative procedure and it would not require surgical removal. The purpose of this study is to investigate the absorption periods of oxidized cellulose at the implant site and usefulness as a mechanical barrier, preventing the ingrowth of the overlying soft tissue into the bony defects. Two bony defects were made in each tibia of a dog using drill and one defect covered with oxidized cellulose and the other covered with periosteum directly as control. The experimental animals were sacrificed at 1st-7th, 10th, 14th, 21th, 28th day postoperatively, Inspection of the specimens was done to evaluate gross changes. Specimens were examined histopathologically by hematoxylin-eosin and Masson's trichrome staining under light microscope. The results were as follows : 1. There was no significant differences of inflammatory reaction between the experimental and the control group. 2. The resorption of oxidized cellulose was almost completed within 14th day. 3. Histologically, bone formation in the experimental group was somewhat more than that of the control group at 10th, 14th, 21th and 28th day postoperatively. The bone forming pattern of the experimental group was more regular than that of the control group. 4. There was no evidence of soft tissue invasion into the bony defect in the experimental group. In conclusion, oxidized cellulose membrane might be used as an alternative absorbable barrier membrane to prevent overlying soft tissue invasion into the bony defects.

  • PDF