• Title/Summary/Keyword: polymer concrete composite

Search Result 207, Processing Time 0.022 seconds

Computational optimized finite element modelling of mechanical interaction of concrete with fiber reinforced polymer

  • Arani, Khosro Shahpoori;Zandi, Yousef;Pham, Binh Thai;Mu'azu, M.A.;Katebi, Javad;Mohammadhassani, Mohammad;Khalafi, Seyedamirhesam;Mohamad, Edy Tonnizam;Wakil, Karzan;Khorami, Majid
    • Computers and Concrete
    • /
    • v.23 no.1
    • /
    • pp.61-68
    • /
    • 2019
  • This paper presents a computational rational model to predict the ultimate and optimized load capacity of reinforced concrete (RC) beams strengthened by a combination of longitudinal and transverse fiber reinforced polymer (FRP) composite plates/sheets (flexure and shear strengthening system). Several experimental and analytical studies on the confinement effect and failure mechanisms of fiber reinforced polymer (FRP) wrapped columns have been conducted over recent years. Although typical axial members are large-scale square/rectangular reinforced concrete (RC) columns in practice, the majority of such studies have concentrated on the behavior of small-scale circular concrete specimens. A high performance concrete, known as polymer concrete, made up of natural aggregates and an orthophthalic polyester binder, reinforced with non-metallic bars (glass reinforced polymer) has been studied. The material is described at micro and macro level, presenting the key physical and mechanical properties using different experimental techniques. Furthermore, a full description of non-metallic bars is presented to evaluate its structural expectancies, embedded in the polymer concrete matrix. In this paper, the mechanism of mechanical interaction of smooth and lugged FRP rods with concrete is presented. A general modeling and application of various elements are demonstrated. The contact parameters are defined and the procedures of calculation and evaluation of contact parameters are introduced. The method of calibration of the calculated parameters is presented. Finally, the numerical results are obtained for different bond parameters which show a good agreement with experimental results reported in literature.

The effect of CFRP-concrete bond mechanism on dynamic parameters of repaired concrete girders

  • Fayyadh, Moatasem M.;Razak, Hashim A.
    • Structural Engineering and Mechanics
    • /
    • v.82 no.3
    • /
    • pp.343-354
    • /
    • 2022
  • An understanding of the mechanism of concrete girders repaired with CFRP plates and its influence on the dynamic parameters is presented in this paper. Dynamic parameters are governed by the relationship with the physical properties of concrete girders and CFRP plates as well as the adhesive layer between them. A brief explanation of the mechanism of the composite action of concrete girders repaired with CFRP is also given in this paper. Experimental work was carried out to validate the theory of the composite action. The results show a decrease in the modal parameters of CFRP repaired girders that were turned over during the repair procedure, which contrasts with the proven static-based results that CFRP plates increase the stiffness of repaired girders. The composite action theory has explained the results based on the tension and compression forces' growth at the adhesive layer between the CFRP plates and girder surface during the repair procedure. Other girders were prepared and repaired without turning over in order to avoid tension and compression forces at the adhesive layer. The experimental results show an increase in the dynamic parameters of CFRP repaired girders that were not turned over during the repair procedure, which aligns with the static-based results. The study concludes that the dynamic parameters are excellent indicators for the assessment of CFRP repaired concrete girders. The study also suggests that researchers should not turn over damaged concrete girders to repair them with CFRP plates if they intend to study the dynamic parameters, in order to avoid the proposed composite action effect on modal parameters.

Development of Polymer-Concrete Composite(I) - Physical Properties of Polymer-Cement Concrete Composites - (폴리머-콘크리트 복합재료 개발(I) - 폴리머-시멘트 콘크리트의 물성 -)

  • Hwang, Eui-Hwan;Kil, Deog-Soo;Oh, In-Seok
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.979-984
    • /
    • 1997
  • Test specimens of polymer-cement concrete composites were prepared using styrene-butadiene rubber(SBR) latex, ethylenevinyl acetate(EVA) and polyacrylic ester(PAE) emulsions as polymer dispersions in cement modified system at constant slump($10{\pm}0.5cm$), then compressive and flexural strengths water absorption, pore size distribution, and microstructures were investigated. Compressive and flexural strengths of these composites were remarkably improved with an increase of polymer-cement ratio. These composites had a desirable pore size distribution against frost damage due to a small capillary pore volume. Continuous polymer film was able to form in higher than 15% of polymer cement ratio.

  • PDF

An Evaluation on the Flexural Strength of Concrete Beams Repaired by Polymer Resin (폴리머계로 보수한 철근콘크리트 보의 휨성능 평가)

  • Kim, Byung-Guk;Shin, Young-Soo;Hong, Gi-Suop;Hong, Yung-Kyun;Choi, Oan-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.1
    • /
    • pp.107-112
    • /
    • 1997
  • A series of reinforced concrete beams was tested to evaluate the flexural performance of the repaired RC beams. The key parameters for this study were the size and location of the patch, and the repair materials, including polymer, polymer-cementitious and cementitious materials. The repaired specimens failed by a typical flexural mode with minor interfacial bond failure. Beams repaired with polymer, polymer-cementitious and cementitious materials recover 100%, 91%, and 97% of the flexural strength respectively, while beams with cement mortar lose approximately 30% of the strength. Compared with the pressure injection techniques the specimens repaired with patching techniques show low flexural strength, with significant interfacial bond failure. Location and size of the repaired part do not affect the recovering performance. Interfacial behavior between repair and strengthening materials is the major influencing factor for the composite structures.

  • PDF

Experimental Study on Ultra-Violet Resistance of FRP composites used in Strengthening RC members (FRP 복합체의 자외선 저항성에 관한 실험적 연구)

  • Song, Tae-Hyeob;Choi, Ki-Sun;You, Young-Chan;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.333-336
    • /
    • 2006
  • In general, polymer materials undergo degradation when exposed to ultraviolet radiation, which can cause dissociation of chemical bonds. FRP composites which are used in strengthening existing structure are usually adhered on the concrete surface, its mechanical properties as well as appearance such as color, surface conditions are affected by sunlight and expecially ultraviolet light. In this study, variations of tensile strength after exposure for certain period of time through accelerated exposure by Xe arc methods specified in KS F 2274 are measured in order to examine strength degradation characteristics of FRP composite. As a result of ultraviolet light test for FRP composite after accelerated exposure for 0, 500, 1000, 1500 hour, discoloration of FRP composite occurs according to the passage of time. But, few strength degradations of FRP composite are observed due to exposure of ultraviolet ray with an small variation of tensile strength.

  • PDF

Bonding and debonding behavior of FRP sheets under fatigue loading

  • Iwashita, Kentaro;Wu, Zhishen;Ishikawa, Takashi;Hamaguchi, Yasumasa;Suzuki, Toshio
    • Advanced Composite Materials
    • /
    • v.16 no.1
    • /
    • pp.31-44
    • /
    • 2007
  • The purpose of this study is to improve the examining and understanding of the bonding behavior of Fiber Reinforced Polymer (FRP) sheets bonded to concrete blocks and steel plates under fatigue loading. First, a series of experimental investigations is summarized in the paper. The fatigue behavior of bonding surface between FRP sheets and concrete is finally characterized by the conducted P-S-N diagram representing the relationship among the probability of FRP debonding (P), the bond stress amplitudes (S), and the number of cycles (N) at debonding on a semi-logarithmic scale. The different debonding modes for various fracturing surface are also investigated and evaluated.

A Successful Beginning for Fiber Reinforced Polymer(FRP) Composite Materials in Bridge Applications (섬유보강폴리머(FRP) 복합재료의 교량 적용)

  • 김지상
    • Magazine of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.77-81
    • /
    • 2001
  • 부식 열화는 교량 기술자들에게 있어서 지속적인 도전을 요구하는 문제가 되어왔는데, 스텔스 항공기를 개발하게 한 새로운 재료 기술은 교량의 부식을 해결할 수 있게 하였다. 즉, 경량의 고강도 재료로 높은 피로 저항성을 갖고 있고, 부식에 강한 복합체는 교량의 재료로서 아주 바람직한 성질을 갖고 있다 섬유 보강 폴리머(FRP) 복합재료를 교량의 건설에 이용하려는 프로젝트는 1998년 현재 80 여 개가 넘게 진행되고 있는데, 이 중 미국 내에서 31개의 프로젝트가 수행되고 있다. 이 글은 미국 내에서 FRP복합체를 교량 공학 분야에 적용하려는 초기의 성공적인 시도들에 관한 내용으로 복합체의 장점, 특성, 교량 적용시 고려 사항, 그리고 향후 복합재료에 관한 기술을 토목 구조물에 적용하는데 필요한 소요 기술 등에 관하여 정리한 것이다. 이 새로운 재료는 신설 구조물의 건설과 기존 교량의 보수 및 보강에 모두 적용할 수 있으며, FRP복합체 기술을 토목 구조물과 기반 시설물 건설 분야에 적용하는 것은 지금까지 성공적인 결과를 보여 주고 있다 미국연방도로국(FHWA, Federal Highway Administration)은 이 기술을 미국 내 교통 기반 시설물인 신규 교량의 건설은 물론 기즌 교량의 보수 및 보강에 활용하는 방안에 대하여 관심을 갖고 있다.

Fire performance of concrete-filled steel tubular columns strengthened by CFRP

  • Tao, Zhong;Wang, Zhi-Bin;Han, Lin-Hai;Uy, Brian
    • Steel and Composite Structures
    • /
    • v.11 no.4
    • /
    • pp.307-324
    • /
    • 2011
  • With the increasing use of concrete-filled steel tubes (CFST) as structural members, there is a growing need to provide suitable measures for possible strengthening or repair of these kinds of structural elements. Fibre reinforced polymer (FRP) jacketing is a recent method and is particularly attractive in which it does not significantly increase the section size, and is relatively easy to install. Thus, it can be used to enhance strength and/or ductility of CFST members. Very little information is available on the performance of FRP-strengthened CFST members under fire conditions. This paper is an attempt to study the fire performance of CFST columns strengthened by FRP. The results of fire endurance tests on FRP-strengthened circular CFST columns are presented. Failure modes of the specimens after exposure to fire, temperatures in the cross section, axial deformation and fire resistance of the composite columns are analysed. It is demonstrated that the required fire endurance can be achieved if the strengthened composite columns are appropriately designed.

A Study on Technology for Leakage Prevention of Concrete Construction by Flexible Type Waterproofing with Adhesive and Swelling Properties (점착.팽창성 유연형 도막방수재를 이용한 콘크리트 구조물의 누수방지 기술에 관한 연구)

  • 최성민;김종복;장혁수;오상근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.768-773
    • /
    • 1999
  • This study of concrete movement confronting a scope inspects the problems about the waterproofing method and leakage/repairment at present and research the mechanism with the variety of applying examples introducing adhesion and inflation using the flexible type of waterproofing and repairement and the subsititution method developed with polymer resign composite. The polymer resign transmited into adhesion or inflation materials under wet environment absorbs adjoining moisture, wraps impurities of concrete surface, get the waterproofing layer and concrete surface adhere toughly, reorganize the impaired waterproofing layer and get over the detachment of it from concrete surface.

  • PDF

Study on mechanical behavioral characteristics of the curved FRP-concrete composite member for utilization as a tunnel lining structure (터널 라이닝 구조체로서 활용을 위한 곡면 FRP-콘크리트 복합부재의 역학적 거동특성 분석 연구)

  • Lee, Gyu-Phil;Shin, Hyu-Soung;Kim, Seung-Han
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.2
    • /
    • pp.149-158
    • /
    • 2011
  • Utilization of the fiber reinforced polymer (FRP) material has been increased as an alternative in a bid to supplement the problems with general construction materials such as long-term problems corrosion, etc. However, there are still many problems in using a linear-shaped FRP material for a tunnel lining structure which has arch-shape in general. In this study, the loading tests for the FRP-concrete composite member was carried out to evaluate their applicability as a tunnel reinforcement material, which are based on the results from preliminary numerical studies for identifying the behavioral characteristics of FRP-concrete composite member. Moreover, numerical analysis under the same condition as applied in the loading tests was again conducted for analysis of mechanical behavior of the composite member. As a result of the load test and numerical analysis, it appears that the FRP-concrete composite member is greatly subject to shear movement caused by bending tension acting on the interface between two constituent members.