• Title/Summary/Keyword: poly aluminium chloride (PAC)

Search Result 20, Processing Time 0.018 seconds

Preparation of PAC for Water Treatment Chemicals Using Waste Aluminum Dross (알루미늄 폐드로스로부터 수처리응집제용 염화알루미늄 제조)

  • Park, Hyung-Kyu;Choi, Young-Yoon;Eom, Hyoung-Choon;Bae, Dong-Su
    • Resources Recycling
    • /
    • v.15 no.5 s.73
    • /
    • pp.52-56
    • /
    • 2006
  • Waste aluminum dross was leached with hydrochloric acid to prepare PAC, poly aluminium chloride, used as water treatment chemicals. Metallic aluminum remained in the waste aluminum dross was dissolved into the hydrochloric acid solution. The solution could be used as PAC after adjusting the required alumina concentration and the basicity. Comparing to the conventional method far preparation of PAC using aluminum hydroxide, material cost could be saved in this method. Also, there is an additional merit in view of recycling of the waste aluminum dross by reducing the amount of waste dross to be landfilled.

Preparation of Alum and Poly Aluminum Chloride Using Waste Aluminum Dross (알루미늄 폐드로스를 재활용(再活用)한 Alum과 Poly Aluminum Chloride 제조(製造) 연구(硏究))

  • Park, Hyung-Kyu;Lee, Hoo-In;Choi, Young-Yoon
    • Resources Recycling
    • /
    • v.16 no.5
    • /
    • pp.3-7
    • /
    • 2007
  • Waste aluminum dross was processed to prepare alum with sulfuric acid, and poly aluminum chloride(PAC) with hydrochloric acid. Metallic aluminum remained in the waste dross was dissolved into the sulfuric acid solution, and the solution could be used as alum for water treatment chemicals after adjusting the required alumina concentration and pH of the solution. Also, it was dissolved into the hydrochloric acid solution and processed to make PAC solution. Compared with the conventional method for preparation of alum and PAC using aluminum hydroxide, material cost could be saved in this method. Also, there is an additional merit in view of recycling of the waste aluminum dross by reducing the amount of waste disposed to landfill.

Phosphorus Removal from Advanced Wastewater Treatment Process Using PAC (PAC를 이용한 하수의 고도처리공정에서의 인 제거)

  • Park, Wan-Cheol;Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.96-102
    • /
    • 2014
  • To meet the reinforced discharge standards, effect of coagulant PAC (Poly aluminium chloride, 10.4% as $Al_2O_3$) on phosphorous removal in advanced wastewater treatment process (a modified $A^2$/O). 15 mg/L of PAC determined by jar-test was added to influent of settling basin in a modified $A^2$/O consists of anaerobic, anoxic, and oxic chamber which contains Bio-clod and porous polyurethane media. Performance of PAC was tested by supernatant after settling. The removal efficiencies of BOD, COD, TP (total phosphorus) and SP (soluble phosphorus) on biological process with PAC were 96.1%, 88.8%, 97.0% and 98.6%, compared with those on biological process without PAC were 95.4%, 72.4%, 71.6% and 59.5% respectively. 18.4% of TP and 39.1% of SP removal efficiency was increased, although increase of BOD and COD removal rate was not significant. Only PAC addition to influent of settling basin in $A^2O$ process can help total phosphorus removal to 0.13 mg/L with following discharge standard.

Effect of Anionic Polymer on Particle Size Distribution in PAC Coagulation Process for Phosphorus Removal (PAC를 이용한 인제거 공정에서 음이온계 고분자 첨가가 입도 분포에 미치는 영향)

  • Kim, Sunghong;Lee, Dongwoo;Kim, Donghan;Kim, Dooil
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.170-175
    • /
    • 2013
  • Achieving very low phosphorus levels in treated wastewater will require the installation of additional treatment. Phosphorus removal experiments by chemical coagulation were carried out for the effluent of wastewater treatment plant in this study. TP (total phosphorus) or phosphate were highly related to the addition of PAC (poly aluminium chloride) which is one of the inorganic coagulants. But, organic polymer did not significantly affect the phosphorus removal efficiency. Polymer affected the flocculation of particle especially particle matter less than 10 micrometer so, the number of micro particles was decreased by polymer dose. Chlorination would not affect on chemical coagulation process and TP and turbidity could be effectively removed by the co-addition of PAC and polymer.

Optimal coagulant and its dosage for turbidity and total organic dissolved carbon removal (탁도와 총유기탄소 제거를 위한 최적응집제 및 투여량 선정 연구)

  • Park, Hanbai;Woo, Dal-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2321-2327
    • /
    • 2015
  • Three coagulants, alum sulfate(alum), poly aluminum chloride(PAC) and poly aluminum silicate chloride (PASC), were used to remove low to high turbidity and TOC in surface and ground blended water. Laboratory experiments and pilot plant experiments were carried out to evaluate the optimal coagulant and its dosage. To determine the optimized coagulant and its dosage, the turbidity, TOC and pH were measured. The experimental results showed the best removal performance using PASC. The optimal dosage of PASC between 3-20 NTU was found to be 15 mg/L in the jar test. In the pilot test, a 15 mg/L PASC dosage was applied and resulted in the efficient removal of turbidity and TOC between 3.6-27 NTU. The removal efficiency of PASC increased with increasing turbidity and TOC.

Optimum Coagulation of Water Treatment Plant using On-line Floc Monitoring System (정수장 응집제주입 최적화를 위한 플럭 모니터링)

  • Hwang, Hwando;Lim, Sangho;Sung, Kyujong;Han, Youngjin;Kim, Youngbeom;Kwak, Jongwoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.397-406
    • /
    • 2009
  • This study was conducted to monitor the floc sizes forming in the mixing zone in the water treatment plant. The dosing amount of poly aluminium chloride(PAC) was determined by particle dispersion analyzer(iPDA) in the lab and field scale test. During a field test period, PAC coagulant was used and the raw water was taken from Nakdong river. PAC wad diluted to activate the coagulant, leading to bring the more homogeneous dispersion in the shorter time. To monitor the floc sizes, the unit of floc size index(FSI) was used. With increasing of raw water turbidity, FSI value was increased. Also, the increased dosing amount of PAC brought the increased FSI and with overdosing of coagulant was in turn decreased. When the PAC was fed into the raw water after dilution in a field scale test, the width of FSI was narrower compared with the feeding of the mother liquor of PAC, implying that the formed flocs are denser and more uniform sizes. The width of FSI in average was varied on depending on the basicity of coagulant. Also, dF value, fractal dimension was evalued with the different coagulants, showing from 2.01 to 2.03. On-line floc monitor was effective for the optimal dosing in the drinking water plant.

Precipitaion of Acid Mine Drainage Using Coagulants and Flocculants (유기 및 무기응집제를 이용한 산성광산배수 침전 연구)

  • Oh, Taek-Geun;Hwang, Won-Jeong;Lee, Jong-Un;Cha, Jongmun
    • Resources Recycling
    • /
    • v.25 no.3
    • /
    • pp.3-10
    • /
    • 2016
  • The passive treatment was required a large area for the treatment of acid mine drainage (AMD), and pollutants were discharged with mine drainage by the increased flow rate in summer. This study was performed to improve the turbidity and to precipitate the pollutants quickly using coagulants and flocculants in AMD of abandoned mine sites that were difficult to build the passive treatment system. The coagulant PAC (Poly aluminium chloride) and flocculant PAM (Polyacrylamide) were selected to improve turbidity in W mine waters. We also tested the particle size analysis, ICP-OES and/or SEM-EDS for water and sludge samples.

Variation of Sedimentation & Dewaterability Characteristics of Sewage Sludge under Various Coagulants (응집제 종류에 따른 하수 슬러지의 침강 및 탈수 특성 변화)

  • Baik, Seon Jai;Jo, Jung Min;Song, Hyun Woo;Han, Ihn Sup
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.311-318
    • /
    • 2014
  • The purpose of this study is to investigate the effect of various types of coagulant on dewaterability and settleability of sewage sludge for the application of dewatering process. Cationic organic coagulants and inorganic coagulants of the aluminium base were used; PAC (Poly Aluminium chloride, $Al_2O_3$ 17%) and C-210P (0.2%). After Jar test, PAC 26 mg/L and 0.2% C-210P 55 mg/L was decided as the optimum concentration of the coagulant according to zeta potential measurement. pH, alkalinity and viscosity were measured in all experiments and the data on sedimentation characteristics is analyzed by SDI, SVI sedimentation rate and solid flux. The SRF(Specific Resistance of Filtration) experiment was conducted with the result of single and dual injection system as the dewaterability experiment. As a result, the organic coagulant making large floc has good characteristics of sedimentation and agglutination. Also, it is observed that the organic coagulants injection has a better dewaterability efficiency of coagulants under the condition of the lowest SRF value, followed by dual and inorganic coagulants injection.

Co-precipitation of Turbidity and Dissolved Organic Matters by Coagulation (응집(凝集)에 의한 탁도물질(濁度物質) 및 용존(溶存) 유기물질(有機物質)의 동시제거(同時除去)에 대한 연구(硏究))

  • Jeong, Sang-Gi;Jun, Hang-Bae;Kim, Hag-Seong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.3
    • /
    • pp.99-107
    • /
    • 1995
  • Various humic substances are widely distributed in natural water body, such as rivers and lakes and cause the yellowish or brownish color to water. The evidence that humic substances are precursors of THMs formation in chlorinated drinking water has been reported m the Jiteratures. For the reason of public health as well as aesthetics, needs for humic substances removal have been increased in the conventional water treatment processes. In this research, the characteristics of aluminium coagulation of humic acids and humic acids were investigated. The optimum pH and coagulants dosage to remove these materials simultaneously by coagulation were alto studied. The results are as followed; 1. UV-254 absorptiometry for measuring the concentration of aquatic humic acids showed good applicability and stable results. 2. The optimal pH range for humic acids removal by aluminium coagulation was 5 to 5.5, however, an increase in aluminium coagulant dosage could enhance the removal rate of humic acids in the wide pH range. 3. Coprecipitation of humic acids in the typical pH range of 6.5 to 8 in water treatment processes may require the sweep coagulation mechanism with the excess aluminium coagulant dosage. 4. Using PAC(poly aluminium chloride) or PASS(poly aluminium silica sulfate) as coagulants was able to expand the operating range for removing humic acids. 5. From the coagulation of humic substances(UV-254) and turbidity at pH range of 5.5 - 6.0 and alum dose of 86 ppm, the removal efficiency of turbidity from the reservoir water was above 90% and that of UV-254 was above 70%. 6. By using the reservoir water, the optimum condition of rapid mixing for simultaneous removal of turbidity and UV-254 absorbance was pH of 5.8 and LAS dose of 86 ppm, in this study.

  • PDF

A Study on the Applicability of Torrefied Wood Flour Natural Material Based Coagulant to Removal of Dissolved Organic Matter and Turbidity (용존성 유기물질 및 탁도 제거를 위한 반탄화목분 천연재료 혼합응집제의 적용성에 관한 연구)

  • PARK, Hae Keum;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.472-487
    • /
    • 2020
  • With the emergence of abnormal climate due to the rapid industrialization, the importance of water quality management and management costs are increasing every year. In Korea, for the management of total phosphorus and total nitrogen, the major materials causing the water quality pollution, coagulants are injected in sewage treatment plants to process organic compounds. However, if the coagulant is injected in an excessive amount to PAC (Poly Aluminium Chloride), a secondary pollution problem might occur. As such, a study on the applicability of natural material-based coagulant is being conducted in Korea. Thus, this study aimed to evaluate the applicability of a mixed coagulant developed by analyzing water quality pollutants T-P, T-N as well as their turbidity, in order to derive the optimum mixing ratio between PAC and torrefied wood flour for the primary settling pond effluent. Under the condition where the content of PAC (10%) and torrefied wood flour is 1%, T-P showed the maximum removal efficiency of 92%, and T-N showed approximately 22%. This indicates that removal of T-N which includes numerous positively charged organic compounds that are equivalent to mixed coagulant is not well accomplished. Turbidity showed the removal efficiency of approximately 91%. As such, 1% of torrefied wood flour was determined to be the optimum addition. As a result of analyzing the removal efficiency for organic compounds by reducing PAC concentration to 7%, T-P showed a high maximum removal efficiency of 91%, T-N showed 32%, and turbidity showed the maximum of 90%. In addition, a coagulation process is performed by using the mixed coagulant based on 1% content of torrefied wood flour produced in this study by performing a coagulation performance comparative experiment with PAC (10%). As a result, PAC concentration was reduced to 30-50%, a similar performance with other coagulants in market was secured, PAC injection amount was reduced that an economic effect can be achieved, and it is considered to perform a stable water treatment that reduces the secondary pollution problem.