• Title/Summary/Keyword: pollution amount

Search Result 852, Processing Time 0.031 seconds

Estimation of Pollution Load in Anyang Stream Basin Using GIS (GIS를 이용한 안양천 유역의 오염부하량 산정)

  • 최종욱;유병태;이민환;김건흥
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.3
    • /
    • pp.1-9
    • /
    • 1999
  • In the estimation of pollution load in water basin, a data information has generally used from surveyed data. A Geographic Information System(GIS) was adopted to evaluate the amount of pollution load in Anyang stream basin which is one of the major tributaries in the Han river flows through urban area. The digital maps of administrative boundary, stream network, sub-basin, soil type, and land-use for spatial data as well as attribute data were generated. And the database of sub-basins and pollution source was structured to estimate pollution load in Anyang stream basin by an Arc/Info GIS.As the results of this investigation, the pollution load of Mokgam-chun sub-basin was the highest amount. And that of Hagi-chun sub-basin and the fourth main stream sub-basin were also high amount in Anyang stream basin. In general, it was found that the pollution load generated from the upstream area in Kyunggi province was higher than that from downstream area in Seoul. Because the point and non-point source pollution load played very significant role in the deterioration of the water quality of the Anyang stream, an integrated approach to water quality management should be required for the sub-basins of high pollution load amount.

  • PDF

A Case Study of Decreasing Environment Pollution Caused by Energy Consumption of a Dormitory Building Which Only Using Electricity by Efficiently Simulating Applying Residential SOFC (Solid Oxide Fuel Cell)

  • Chang, Han;Lee, In-Hee
    • Architectural research
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • Recent years in Korea, some new developed buildings are only using electricity as power for heating, cooling, bathing and even cooking which means except electricity, there is no natural gas or other kinds of energy used in such kind of building. In vehicle industry area, scientists already invented electric vehicle as an environment friendly vehicle; after that, in architecture design and construction field, buildings only using electricity appeared; the curiosity of the environment impact of energy consumption by such kind of building lead me to do this research. In general, electricity is known as a clean energy resource reasoned by it is noncombustible energy resource; however, although there is no environmental pollution by using electricity, electricity generation procedure in power plant may cause huge amount of environment pollution; especially, electricity generation from combusting coal in power plant could emit enormous air pollutants to the air. In this research, the yearly amount of air pollution by energy using under traditional way in research target building that is using natural gas for heating, bathing and cooking and electricity for lighting, equipment and cooling is compared with yearly amount of air pollution by only using electricity as power in the building; result shows that building that only uses electricity emits much more air pollutants than uses electricity and natural gas together in the building. According to the amount of air pollutants comparison result between two different energy application types in the building, residential SOFC (Solid oxide fuel cell) is simulated to apply in this building for decreasing environment pollution of the building; furthermore, high load factor could lead high efficiency of SOFC, in the scenario of simulating applying SOFC in the building, SOFC is shared by two or three households in spring and autumn to increase efficiency of the SOFC. In sum, this research is trying to demonstrate electricity is a conditioned environment friendly energy resource; in the meanwhile, SOFC is simulated efficiently applying in the building only using electricity as power to decrease the large amount of air pollutants by energy using in the building. Energy consumption of the building is analyzed by calibrated commercial software Design Builder; the calibrated mathematical model of SOFC is referred from other researcher's study.

The Comparison of the Relationship between the Gunfire Shot and Its Resulting Heavy Metal Pollution Rate (소화기 사격장의 사격에 따른 중금속 오염도 비교(I))

  • Hong, Sung Tae;Hyun, Jae Hyuk
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.1-5
    • /
    • 2014
  • The following research was initiated in order to compare the relationship between the amount of gunfire shot and its resulting heavy metal pollution rate. The research was conducted at two firing ranges located inside a military unit stationed in the rear strategical area, where one full distance firing range is used by soldiers in active service, and the other is used by recruits and reserves. The heavy metal pollution rate was measured also on water sample collected from the target zone while raining. Based on values such as the real amount of gunshot fired, amount of heavy metal in the soil of the target zone, and the degree of heavy metal pollution for each firing range, the research showed that although pollution rate was higher when more gunshots were fired, there was no close correlation between the two. The water samples showed that this might result from the soils containing heavy metals eroded and transported by rain due to the target zone having no vegetation.

Characteristics on Stream Water Quality in the Northeastern Part of Puk'ansan National Park(III) - With a Special Reference to the Factor Influenced on Stream Water Quality Pollution - (북한산국립공원(北漢山國立公圓) 북동사면(北東斜面) 일대(一帶) 계류수질(溪流水質) 특성(特性)(III) - 계류수질(溪流水質) 오염(汚染)에 미치는 영향인자(影響因子)를 중심(中心)으로 -)

  • Park, Jae Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.3
    • /
    • pp.297-305
    • /
    • 2000
  • This research was conducted to analyze the factors influenced on stream water quality pollution in the northeastern part of Puk'ansan National Park from July, 1998 to November, 1999. The number of visitor and the percentage of the amount of $Cl^-$ resulted in the increase of electrical conductivity, which affected on pollution of the stream water quality. The relationships between those factors should be statistical significance at the 5% level in multiple regression. The multiple regression equations for the percentage of dissolved oxygen at the stream water quality showed that dissolved oxygen and water temperature had statistical significance at the 1% level. The multiple regression equations for the amount of $Cl^-$ at the stream water quality showed that electrical conductivity, the amount of cation($K^+$, $Na^+$), the amount of $SO_4{^{2-}}$, total amount of ion, the percentage of the amount of $Cl^-$, and the percentage of the amount of $SO_4{^{2-}}$ had statistical significance at the 5% and 1% level. Also, The multiple regression equations for the amount of $NO_3{^-}$ at the stream water quality showed that the amount of cation($Na^+$, $Ca^{2+}$), the amount of $SO_4{^{2-}}$, the percentage of the amount of $Cl^-$, and the percentage of the amount of $NO_3{^-}$ had statistical significance at the 5% and 1% level. The multiple regression equations for the amount of $SO_4{^{2-}}$ at the stream water quality showed that the amount of $NO_3{^-}$, total amount of ion had statistical significance at the 5% level.

  • PDF

A Generation and Accuracy Evaluation of Common Metadata Prediction Model Using Public Bicycle Data and Imputation Method

  • Kim, Jong-Chan;Jung, Se-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.287-296
    • /
    • 2022
  • Today, air pollution is becoming a severe issue worldwide and various policies are being implemented to solve environmental pollution. In major cities, public bicycles are installed and operated to reduce pollution and solve transportation problems, and operational information is collected in real time. However, research using public bicycle operation information data has not been processed. This study uses the daily weather data of Korea Meteorological Agency and real-time air pollution data of Korea Environment Corporation to predict the amount of daily rental bicycles. Cross- validation, principal component analysis and multiple regression analysis were used to determine the independent variables of the predictive model. Then, the study selected the elements that satisfy the significance level, constructed a model, predicted the amount of daily rental bicycles, and measured the accuracy.

A Study on Air Pollution in Indoor Gymnasiums (실내체육관에서의 공기오염에 관한 연구)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

GIS based Non-Point Source Pollution Assessment

  • Sadeghi-Niaraki, Abolghasem;Kim, Kye-Hyun;Lee, Chol-Young
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.437-440
    • /
    • 2008
  • In recent years, pollution load calculation has become a topic for research that resulted in the development of numerous GIS modeling methods. The existing pollution method for nonpoint source (NPS) can not be indentified and calculated the amount of the pollution precisely. This research shows that the association of typical pollutant concentrations with land uses in a watershed can provide a reasonably accurate characterization of nonpoint source pollution in the watershed using Expected Mean Concentrations (EMC). The GIS based pollution assessment method is performed for three pollutant constituents: BOD, TN, and TP. First, the runoff grid by means of the precipitation grid and runoff coefficient is estimated. Then, the NPS pollution loads are calculated by grid based method. Finally, the final outputs are evaluated by statistical technique. The results illustrate the merits of the approach. This model verified that GIS based method of estimating spatially distributed NPS pollution loads can lead to more accurate representation of the real world.

  • PDF

A Study on the Emission Estimate of Pollutants in Pusan (부산지역에서의 오염물 배출량 산정에 관한 연구)

  • 김유근;이화운;전병일;방종선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.361-367
    • /
    • 1996
  • In order to accurately predict air pollution concentration according to reduction of air pollutant emission, a numerical model is needed. And the total emission amount of air pollutants should be estimated to explain the air pollution phenomena. The characteristics of the emission amount from area, line, and point sources in Pusan were studied by using emission data during one year (1992). The result showed that the annual total emission amount of pollutant is about 299,744 tons in Pusan. The emission consists of 31.8% of $SO_2$, 48.4% of CO, 4.6% of HC, 11.0% of NOx and 4.1% of TSP, as well as 52.1% of line, 24.1% of area and 23.7% of point sources. The result also showed that emission amount becomes larger in winter than that of the others.

  • PDF

Treatment of Concrete Wastewater in Repair of Bridge Deck (교량 바닥판 보수공사에서 발생하는 콘크리트 폐수처리 방안)

  • Lee, Bong-Hak;Choi, Pan-Gil;Kim, Jung-Ki
    • Journal of Industrial Technology
    • /
    • v.28 no.A
    • /
    • pp.125-132
    • /
    • 2008
  • As of 2003, construction waste has been produced at the level of 130,614.8 tons/day, in which the amount of waste concrete was 92,639.1 tons/day and accounted for about 66.4% of the amount of construction waste. Waste concrete is mainly produced in construction work and civil engineering work. Especially, road surface crushing method using a large amount of water requires thorough management of concrete wastewater. The aim of this study was to analyze water pollution due to concrete wastewater generated in repair of bridge deck using road surface crushing equipment and to suggest reasonable countermeasures for solve the problem. In this study, it was surveyed current conditions of produced concrete wastewater in bridge deck repair, analyzed physical features of concrete wastewater, expected effects of water pollution on inflow rivers if it is not treated, established treatment plan of water pollution by categories, and calculated capacity of each treatment process and required amount of necessary chemicals. As a result of sampling wastewater generated in field sites and testing it at a lab scale, it was revealed that the original wastewater was produced in removing concrete from bridge deck slabs using surface crushing equipment whose pH was 12.53, CODMn was 12.910mg/L, SS was 547.0mg/L, and other heavy metals were included in extremely small quantities.

  • PDF

Synthetic Detergent and our Daily Lives as Consumers against Environmental Pollution. (환경오염과 합성세제에 대한 소비생활)

  • Lee, Eun-Kyung
    • Korean Journal of Human Ecology
    • /
    • v.4 no.1
    • /
    • pp.123-133
    • /
    • 1995
  • Lately our environments have been destroyed by such new things as synthetic detergent. How to use detergent at home can be a decisive factor for decreasing water pollution because living sewage by using detergent at home is the main cause of water pollution. We consumers, therefore, should understand the relation between the chemical ingredients of detergent and water pollution and should choose detergent always taking the kinds of detergent, its washing pewer into consideration. We should also contribute to the protection of out environment by keeping the standard of using amount attached to the products.

  • PDF