• Title/Summary/Keyword: polishing methods

Search Result 199, Processing Time 0.025 seconds

에어백 공구에 의한 비구면 유리 렌즈 금형의 전면 접촉 연마 (Full Contact Polishing Method of Aspherical Glass Lens Mold by Airbag Polishing Tool)

  • 이호철;김중억
    • 한국공작기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.82-88
    • /
    • 2008
  • Conventional aspherical lens polishing methods by the small tool polishing use aspherical profile and the trajectory of the polishing tool is also controlled. In this paper, new full contact polishing mechanism is suggested to polish aspherical glass lens mold by both airbag polishing tool and eccentric motion. Full contact concept by airbag polishing tool and no position control make the easy polishing setup and do not need aspherical design profile. An aspherical lens polishing machine was made for this study and a verification experiment was performed for surface roughness improvements.

자유곡면 연마를 위한 자동 연마 시스템 개발 (Development of Computer Control Polishing System for Free Form Surface)

  • 전문식;오창진;이응석;김옥현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.327-331
    • /
    • 2001
  • In the process of optical parts machining, polishing has been applied. Traditional polishing process is suitable for spherical optical parts. But it is very difficult to apply traditional process for aspheric optical parts. Nowadays, as growing needs for aspherical optic parts, many researches have been conducted. In this study, we developed computer controlled polishing system which consists of three major parts of active pressure control for correcting polishing process, mechanical on-machine measurement for rough polishing, and optical on-machine measurement for finish polishing, respectively. In this paper, a systematic stretegy for correcting polishing process, pressure control scheme for polishing tool, and on-machine measurement methods for automated and precise polishing are suggested. The information about developed machine is also included.

  • PDF

라미네이트 도재 수복물의 연마 방법에 따른 표면 거칠기의 비교 (COMPARISON OF SURFACE ROUGHNESS OF VARIOUS LAMINATE VENEER PORCELAIN ACCORDING TO POLISHING METHODS)

  • 권영숙;이근우
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.246-265
    • /
    • 1996
  • After adjusting glazed surface of laminate veneer porcelain by reduction in the clinical procedure, an additional polishing procedure is required to smoothen the roughened surface by reduction, as it is difficult to glaze it again in the furnace. In this study, four kinds of laminate veneer porcelain were ground with diamond points as done in the clinical procedure. The adjusted porcelain surface was polished with Durawhite stone, Ceramiste points, Exa cerapol, Porcelain polishing wheel, Diamond polishing paste. The degree of surface roughness was evaluated with SEM and profilometer at each step, The self glazed surface and the glazed surface with glazing powder were compared with the polished surface and surface roughness of four kinds of laminate veneer porcelain according to the polishing method and step were obserbed. The following results were obtained : 1. There was no difference in the average surface roughness Ra value and the surface roughness obserbed under SEM according to the polishing methods and steps used, among the four kinds of laminate veneer porcelain including Colorlogic, Exelco, Vintage, and Vitadur alpha product. 2. Due to porosities, the surface in the course of polishing by polishing instruments was rougher than the glazed surface, evaluated with a SEM. 3. Insta-Glaze diamond polishing paste has no statistical difference with self glazed group 1, although it has a lower value in average surface roughness Ra value. 4. Group 2 which was glazed with galzing powder was lowest in view of SEM, but it revealed higher surface roughness Ra value than group 1, the glazed surface and group 8, polished by diamond polishing paste, due to surface waveness. 5. Proper surface smoothness could not be in the surface roughness analysis of SEM and profilometer by Shofu laminate polishing kit composed of Diamond point, Durawhite stone and Ceramiste points. Based on the results of this study, the following conclusions can be drawn. We obtain low surface roughness than glazed surface by polishing instruments, but not perfect results clinically. In order to obtain a perfect clinical result or a surface smoothness comparable to glazed porcelain there is a need for further improvement of porcelain materials, condensa-tion techniques, polishing instruments and polishing methods. Furthermore card should be taken not to breakdown the glazed surface during the clinical and laboratory procedure.

  • PDF

Front-end investigations of the coated particles of nuclear fuel samples - ion polishing method

  • Krajewska, Zuzanna M.;Buchwald, Tomasz;Tokarski, Tomasz;Gudowski, Wacław
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.1935-1946
    • /
    • 2022
  • The investigations of the coated-particles of nuclear fuel samples are carried out in three stages: front-end, irradiation in the reactor core, and post-irradiation examination. The front-end stage is the initial analysis of the failures rates of produced samples before they are placed in the reactor core. The purpose of the verification is to prepare the particles for an experiment that will determine the degree of damage to the coated particles at each stage. Before starting experiments with the samples, they must be properly prepared. Polishing the samples in order to uncover the inner layers is an important, initial experimental step. The authors of this paper used a novel way to prepare samples for testing - by applying an ion polisher. Mechanical polishing used frequently for sample preparations generates additional mechanical damages in the studied fuel particle, thus directly affecting the experimental results. The polishing methods were compared for three different coated particles using diagnostic methods such as Raman spectroscopy, scanning electron microscopy, and confocal laser scanning microscopy. Based on the obtained results, it was concluded that the ion polishing method is better because the level of interference with the structures of the individual layers of the tested samples is much lower than with the mechanical method. The same technique is used for the fuel particles undergone ion implantation simulating radiation damage that can occur in the reactor core.

The effect of various polishing systems on surface roughness and phase transformation of monolithic zirconia

  • Caglar, Ipek;Ates, Sabit Melih;Duymus, Zeynep Yesil
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.132-137
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate and compare three polishing systems on the surface roughness and phase transformation of monolithic zirconia. MATERIALS AND METHODS. 100 disk shaped specimens (10 mm diameter, 3 mm thickness) were fabricated from monolithic zirconia blocks. 20 specimens were left as a control group and remaining specimens were grinded by diamond bur to simulate the occlusal adjustments. Grinded specimens were randomly divided into 4 groups: group G (no polishing), group M (Meisinger, zirconia polishing kit), group E (EVE Diacera, zirconia polishing kit), and group P (EVE Diapol, porcelain polishing kit). Surface roughness was measured with profilometer and surface topography was observed with SEM. XRD analysis was performed to investigate the phase transformation. Statistical analysis was performed with one-way ANOVA and Tukey's post hoc tests at a significance level of P=.05. RESULTS. All polishing groups showed a smoother surface than group G. Among 3 polishing systems, group M and group E exhibited a smoother surface than the group P. However, no significant differences were observed between group M and group E (P>.05). Grinding and polishing did not cause phase transformations in zirconia specimens. CONCLUSION. Zirconia polishing systems created a smoother surface on zirconia than the porcelain polishing system. Phase transformation did not occur during the polishing procedure.

EP와 MR Polishing 복합공정에 의한 304 스테인리스강의 경면가공 (Mirrorlike Machining of SUS304 by Combined process of EP and MR Polishing)

  • 김동우;홍광표;조명우;이은상
    • 한국생산제조학회지
    • /
    • 제19권2호
    • /
    • pp.267-274
    • /
    • 2010
  • Recently, the magnetorheological (MR) polishing process has been examined as a new ultra-precision polishing technology for mirror surface generation in many applications, such as aspheric lenses, biochips, micro parts, etc. This method uses MR fluids which contains micro abrasives as a polishing media, and can. It is possible to obtain nano level surface roughness under suitable process conditions, however, required polishing time is highly dependent on the applied pre-polishing methods due to its very small material removal rate. Thus, in this study, a combined polishing method is presented to reduce total polishing time for SUS304. First, the electropolishing (EP) method was applied to obtain fine surface roughness, and the MR polishing was followed. Surface roughness variations were investigated according to the process conditions. As the results of this study, it was possible to reduce total polishing time for SUS304 using the proposed combined polishing method.

불화물 도포 전 치면연마 시행여부에 따른 우식예방효과 (The preventive effect of fluoride materials on the dental caries by dental polishing prior to fluoride application)

  • 조민정;하명옥;오한나
    • 한국치위생학회지
    • /
    • 제12권1호
    • /
    • pp.113-122
    • /
    • 2012
  • Objectives : This study was carried out to investigate the caries resistant effect of fluoride by dental polishing prior to fluoride application in vitro. Methods : Artificial caries lesion was made on the surface of specimen enamel taken from cow's permanent cuspid on the part of labial surface after resin embedding and polishing. Artificial dental plaque was formed on the 72 dental specimen 25~45 VHN(Vickers Hardness Number) which were divided into three groups(fluoride varnish, APF gel, control) with dental polishing and without polishing respectively. Fluoride varnish and APF gel group with 20 second polishing or without polishing were immersed in the artificial saliva respectively. Control group with or without polishing were immersed in the artificial saliva. Results : 1. Significant difference was not found by fluoride varnish between polishing group and non polishing group (p>0.01). 1) polishing group. The changes of Vickers Hardness Number(VHN) were $14.49{\pm}13.73$. 2) non-polishing group. The changes of VHN were $11.67{\pm}5.39$. 2. Significant difference was not found by APF gel between polishing group and non polishing group (p>0.01). 1) polishing group. The changes of VHN were $8.48{\pm}8.37$. 2) non-polishing group. The changes of VHN were $5.32{\pm}2.59$. Conclusions : Showed no significant difference between polishing group and non-polishing group regardless of fluoride materials (fluoride varnish, APF gel).

자기연마법을 이용한 볼나사의 연마가공에 관한 연구 (A Study on Ball Screw Polishing Using Magnetic Assisted Polishing)

  • 이용철;이응숙;최헌종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.43-47
    • /
    • 1995
  • The ball screw is one of the important mechanical parts for the linear motion feeding systems. The usage of the ball screw has been growing in various industrial fields such as CNC machine tool, industrial robot and automated systems. Because of ever increasing demand for ball screws, increased accuracy and quality of the ball screw is needed,especially the surface roughness of the ball contact area in order to diminish noise and vibration. Therefore to improve the surface roughness of the area,we introduced magnetic assisted polishing which is one of the new potential polishing methods. In this study, diamond slurry and iron powder was used for magnetic assisted polishing of the ball bearing surface. This polishing process was experimentally confirmed to improve the surface roughness of the ball bearing.

  • PDF

MAGIC 숫돌에 의한 연마작업의 표준화 (Standardization of Polishing Work by MAGIC Polishing Tool)

  • 조종래;이상태;정윤교
    • 한국정밀공학회지
    • /
    • 제22권10호
    • /
    • pp.39-48
    • /
    • 2005
  • As the industrial development is accelerated, a new machining process and system are keenly required to achieve super precision surface finish. Especially to get ground surface finish fer complicated and narrow inner shape of molds, it is impossible with the existing methods so that a new method is being required to be developed. A new material, called Magic(MAGnetic Intelligent Compounds), is finally made and it is called Magic machining that uses this material. There is a way to make a material as follows, the mixture of magnetic particles, bonding material and particles of abrasive grain should be melt down by proper heat, and then this mixture put in a mold and cool down in magnetic field which has a uniform direction. This new polishing method is spotlighted as an excellent solution to the existing problems. However it hasn't reported any study about the influence of the machining conditions of polishing velocity, amplitude and polishing pressure to the surface roughness yet. This study would examine closely the influence of polishing conditions of the Magic polishing tool to the surface finish to decide the optimum polishing condition and to standardize the Magic polishing work.

치과 주조용 Co-Cr-Mo alloy에서 전해용액 온도와 전해시간에 따른 전해연마의 특성 (Effect of polishing solution temperature and times by electro-polishing in dental casting Co-Cr-Mo alloy)

  • 장재영;송재상;나정숙
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.145-153
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate to effect of the electro-polishing condition according to electrolyte temperature and current and polishing time on surface morphology and composition by scanning electron microscopy(SEM) and energy dispersive X-ray spectrometer(EDS) in dental casting Co-Cr-Mo alloys. Methods: 16 specimens were divided into 4 groups which have each 4 specimens. The size of specimens were 10mm wide and 5mm height. the electro-polishing of specimens are by polishing solution temperature and times in Co-Cr-Mo alloy by SEM and EDS analysis. Results: The results shows that most smooth surface is obtained when electro-polishing is performed at $49^{\circ}C$ for 30-40sec with electro gap of 10mm and 8 voltage. Conclusion: The morphologies of specimens after electro-polishing were scratch absent and significant between at $40^{\circ}C$ for 45sec and at $49^{\circ}C$ for 45sec.