• Title/Summary/Keyword: polarization model

Search Result 352, Processing Time 0.023 seconds

Modeling and State Observer Design of HEV Li-ion Battery (하이브리드 전기자동차용 리튬이온 배터리 모델링 및 상태 관측기 설계)

  • Kim, Ho-Gi;Heo, Sang-Jin;Kang, Gu-Bae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.360-368
    • /
    • 2008
  • A lumped parameter model of Li-ion battery in hybrid electric vehicle(HEV) is constructed and system parameters are identified by using recursive least square estimation for different C-rates, SOCs and temperatures. The system characteristics of pole and zero in the frequency domain are analyzed with the parameters obtained from different conditions. The parameterized model of a Li-ion battery indicates highly dependent of temperatures. To estimate SOC and polarization voltage, a Luenberger state observer is utilized. The P- or PI-gains of observer based on a suitable natural frequency and damping ratio is adopted for the state estimation. Satisfactory estimation accuracy of output voltage and SOC is especially obtained by a PI-gain. The feasibility of the proposed estimation method is verified through experiment under the conditions of different C-rates, SOCs and temperatures.

A computer simulation of ion exchange membrane electrodialysis for concentration of seawater

  • Tanaka, Yoshinobu
    • Membrane and Water Treatment
    • /
    • v.1 no.1
    • /
    • pp.13-37
    • /
    • 2010
  • The performance of an electrodialyzer for concentrating seawater is predicted by means of a computer simulation, which includes the following five steps; Step 1 mass transport; Step 2 current density distribution; Step 3 cell voltage; Step 4 NaCl concentration in a concentrated solution and energy consumption; Step 5 limiting current density. The program is developed on the basis of the following assumption; (1) Solution leakage and electric current leakage in an electrodialyzer are negligible. (2) Direct current electric resistance of a membrane includes the electric resistance of a boundary layer formed on the desalting surface of the membrane due to concentration polarization. (3) Frequency distribution of solution velocity ratio in desalting cells is equated by the normal distribution. (4) Current density i at x distant from the inlets of desalting cells is approximated by the quadratic equation. (5) Voltage difference between the electrodes at the entrance of desalting cells is equal to the value at the exits. (6) Limiting current density of an electrodialyzer is defined as average current density applied to an electrodialyzer when current density reaches the limit of an ion exchange membrane at the outlet of a desalting cell in which linear velocity and electrolyte concentration are the least. (7) Concentrated solutions are extracted from concentrating cells to the outside of the process. The validity of the computer simulation model is demonstrated by comparing the computed results with the performance of electrodialyzers operating in salt-manufacturing plants. The model makes it possible to discuss optimum specifications and operating conditions of a practical-scale electrodialyzer.

STRUCTURE OF THE PHOTOSPHERIC VECTOR MAGNETIC FIELDS (태양광구의 벡터 자기장 구조)

  • Jo, Gyeong-Seok;Kim, Gap-Seong
    • Publications of The Korean Astronomical Society
    • /
    • v.10 no.1
    • /
    • pp.91-108
    • /
    • 1995
  • We have intensively examined the structure of photospheric magnetic fields obtained from the calculation of the polarized radiation transfer for the model atmosphere. To determine more reliable magnetic field in the photospheric region composed of umbra, penumbra and quite area, we have calculated the polarized radiative transfer for a magnetically sensitive spectral line, FeI $6302.5{\AA}$, using our composite model representing three kinds of the atmospheric area distinguished by the pixel value of the Stokes I image over the region. Polarization data of the full Stokes parameters, used in this paper had been obtained from the vector magnetograph on Solar Flare Telescope of National Astronomical Observatory at Mitaka(MTK) in Japan. According to our investigation on the active region in the photosphere, it has been found that the large current density(${\geq}8{\times}10^2A/km^2$) and shear angle(${\geq}85^{\circ}$) should be distributed along the magnetic neutral line. To be compared with the results of MTK, our results in transverse magnetic field strength and direction are similar with those of MTK, however our longitudinal field strength at the center of the spot is somewhat(${\sim}1000$ Gauss) larger than MTK.

  • PDF

Developing on the Soil Moisture Index(SMI) for forecast by using AQUA AMSR-E

  • Park Seung-Hwan;Park Jong-Seo;Park Jeong-Hyun;Kim Kum-Lan;Kim Byung-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.415-418
    • /
    • 2004
  • The Studying is on developing precision of the moisture information on a soil. We used the data of AQUA AMSR-E which were obtained by Direct Receiving System in Korea Meteorological Administration(KMA). Although we know the Soil Moisture Information(SMI) helps the numerical weather model to produce the realistic results, we couldn't do it for the problem on a spatial resolution of the data is too low to apply. So we've tried to develop in a spatial resolution by using the AMSR-E data with a Digital Elevation Model(DEM) and Normal Difference Vegetation Index(NDVI) from AQUA MODIS and compared the difference between their information in statics. The result is more precise than the simple algorithm by a polarization ratio, and we could get the better result to use in forecast practically, if it's apply to get more detail in the vegetation temperature.

  • PDF

Review of Basics Reverse Osmosis Process Modeling: A New Combined Fouling Index Proposed (역삼투 공정을 위한 모델링 총설 및 새로운 복합적 막오염도의 제안)

  • Kim, Albert S.
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.291-312
    • /
    • 2017
  • Seawater desalination is currently considered to be one of the primary technologies to resolve the global water scarcity problem. A basic understanding of membrane filtration phenomena is significant not only for further technological development but also for integrated design, optimal control, and long-term maintenance. In this vein, the present work reviews the major transport and filtration models, specifically related to reverse osmosis phenomena, provides theoretical insights based on statistical mechanics, and discusses model-based physical meanings as related to their practical implications.

Characteristics of V-type Ultrasonic Motor with the Change Angle of Legs (Leg-angle 변화에 따른 V-type 초음파모터의 특성)

  • Jeong, Seong-Su;Park, Min-Ho;Kim, Jong-Wook;Park, Choong-Hyo;Chong, Hyon-Ho;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.320-320
    • /
    • 2010
  • In the case of existing ultrasonic motors, they have characteristics such as outstanding response speed, speed and high efficiency. However, it's very hard to use practically them as small motors due to complicated structure and expensive cost. This paper proposed v-type ultrasonic linear motor. Stator of the motor is composed of thin elastic body and four ceramics attached to upper and bottom areas of the body. The ceramics have each direction of polarization. When two harmonic voltages which had $90^{\circ}$ phase difference were applied to the ceramics, the symmetric and anti-symmetric displacements were generated at the tip to make the elliptical motion. To find out a model that generates maximum displacement at contact tip, FEM program was used with change of leg-angle. In addition, optimal model was chosen by considering magnitude and shape of displacement according to change of frequency.

  • PDF

Molecular-dynamic simulation on the equilibrium and dynamical properties of fluids in a nano-channel

  • Hoang, H.;Kang, S.;Suh, Y.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.208-214
    • /
    • 2008
  • The equilibrium molecular-dynamic simulations have been performed to estimate the properties of the three kinds of fluids (the Lennard-Jones fluid, water and aqueous sodium-chloride solution) confined between two plates that are separated by 1.086 nm; included in the equilibrium properties are the density distribution and the static structure, and the diffusivity in the dynamic property. Three kinds of fluids considered in this study are. The water molecules are modeled by using the SPC/E model and the ions by the charged Lennard-Jones particle model. To treat the water molecules, we combined the quaternion coordinates with Euler angles. We also proposed a plausible algorithm to assign the initial position and direction of molecules. The influence of polarization of water molecules as well as the presence of ions in the solution on the properties will be addressed in this study. In addition, we performed the non-equilibrium molecular-dynamic simulation to compute the flow velocity for the case with the gravitational force acting on molecules.

  • PDF

Molecular-dynamic simulation on the equilibrium and dynamical properties of fluids in a nano-channel

  • Hoang, H.;Kang, S.;Suh, Y.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.208-214
    • /
    • 2008
  • The equilibrium molecular-dynamic simulations have been performed to estimate the properties of the three kinds of fluids (the Lennard-Jones fluid, water and aqueous sodium-chloride solution) confined between two plates that are separated by 1.086 nm; included in the equilibrium properties are the density distribution and the static structure, and the diffusivity in the dynamic property. Three kinds of fluids considered in this study are. The water molecules are modeled by using the SPC/E model and the ions by the charged Lennard-Jones particle model. To treat the water molecules, we combined the quaternion coordinates with Euler angles. We also proposed a plausible algorithm to assign the initial position and direction of molecules. The influence of polarization of water molecules as well as the presence of ions in the solution on the properties will be addressed in this study. In addition, we performed the non-equilibrium molecular-dynamic simulation to compute the flow velocity for the case with the gravitational force acting on molecules.

  • PDF

Influence of the inlet oxygen humidity on PEMFC performance (산소 가습이 PEMFC 성능에 미치는 영향)

  • Lee, Seo-Hee;Moon, Cheor-Eon;Ko, Dong-Soo;Choi, Gyung-Min;Kim, Duck-Jool;Jung, Ji-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.35-38
    • /
    • 2007
  • The comparisons between measured performance of lab-scale PEMFC and calculation were conducted to understand the detail phenomena of PEMFC for the various inlet oxygen humidity of cathode side. Experiments were performed at $65^{\circ}C$ operation temperature and different inlet humidity conditions such as 40%, 60% and 80%. We used the MEA manufactured by oneself which include $Nafion^{(R)}$ 112 membrane, Nafion solution 20%, and carbon paper(E-TEK). As a result of this experiment, cell performance was getting higher by increasing inlet humidity condition at cathode side because ion conductivity of electrolyte membrane is increased. A 3D CFD simulation model of PEMFC was developed using commercially available CFD code that is one of the STAR-CD module, es-pemfc under same operating conditions. Model calculations results were compared with experimental ones on the polarization curves and calculation results are in good agreement with the experimental ones. Local water distribution and current density inside PEMFC are discussed in detail.

  • PDF

Application of Generalized Transmission Line Models to Mixed Ionic-Electronic Transport Phenomena

  • Ahn, Pyung-An;Shin, Eui-Chol;Kim, Gye-Rok;Lee, Jong-Sook
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.6
    • /
    • pp.549-558
    • /
    • 2011
  • Application of a generalized equivalent circuit including the electrode condition for the Hebb-Wagner polarization in the frequency domain proposed by Jamnik and Maier can provide a consistent set of material parameters, such as the geometric capacitance, partial conductivities, chemical capacitance or diffusivity, as well as electrode characteristics. Generalization of the shunt capacitors for the chemical capacitance by the constant phase elements (CPEs) was applied to a model mixed conducting system, $Ag_2S$, with electron-blocking AgI electrodes and ion-blocking Pt electrodes. While little difference resulted for the electron-blocking cell with almost ideal Warburg behavior, severely non-ideal behavior in the case of Pt electrodes not only necessitates a generalized transmission line model with shunt CPEs but also requires modelling of the leakage in the cell approximately proportional to the cell conductance, which then leads to partial conductivity values consistent with the electron-blocking case. Chemical capacitance was found to be closer to the true material property in the electron-blocking cell while excessively high chemical capacitance without expected silver activity dependence resulted in the electron-blocking cell. A chemical storage effect at internal boundaries is suggested to explain the anomalies in the respective blocking configurations.