• Title/Summary/Keyword: point-of-care testing (POCT)

Search Result 16, Processing Time 0.036 seconds

Facile and Effective Detection of Vitamin C on a Paper Based Kit (종이기반 소수성 채널에서의 효율적이고 간편한 비타민 C의 검출기술 개발)

  • Hwang, Jangsun;Seo, Youngmin;Choi, Jonghoon
    • KSBB Journal
    • /
    • v.31 no.1
    • /
    • pp.46-51
    • /
    • 2016
  • Recently paper based diagnostic kits have drawn great interest in the point-of-care testing market (POCT). The paper based detection systems provide inexpensive, rapid and safe analyses for disease markers and/or pathogens. Vitamin C (i.e., ascorbic acid) regulates body's immune system as an antioxidant agent. Humans, however, do not have enough amounts of enzymes involved in the synthesis of vitamin C that it is required to be obtained from their diets (e.g., beverages and/or supplements). Here, we have prepared a paper based kit to detect the concentration of Vitamin C presented in commercially available beverages. The evaluation provides the fast, simple and accurate results for detecting Vitamin C in the prepared paper based kit.

Disposable Strip-Type Biosensors for Amperometric Determination of Galactose

  • Gwon, Kihak;Lee, Seonhwa;Nam, Hakhyun;Shin, Jae Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.310-317
    • /
    • 2020
  • A development of disposable strip-type galactose sensor for point-of-care testing (POCT) was studied, which was constructed using screen-printed carbon electrodes. Galactose levels were determined by the redox reaction of galactose oxidase in the presence of potassium ferricyanide as an electron transfer mediator in a small sample volume (i.e., less than 1 µL). The optimal performance of biosensor was systematically designated by varying applied potential, operating pH, mediator concentration, and amount of enzyme on the electrode. The sensor system was identified as a highly active for the galactose measurement in terms of the sensitivity (slope = 4.76 ± 0.05 nA/µM) with high sensor-to-sensor reproducibility, the linearity (R2 = 0.9915 in galactose concentration range from 0 to 400 µM), and response time (t95% = <17 s). A lower applied potential (i.e., 0.25 V vs. Ag/AgCl) allowed to minimize interference from readily oxidizable metabolites such as ascorbic acid, acetaminophen, uric acid, and acetoacetic acid. The proposed galactose sensor represents a promising system with advantage for use in POCT.

Point-of-care Testing Device Interface in Hospital Information System Standard Connectivity - Using of case ASTM protocol of ABGA application POCT1-A2 - (현장형 임상검사장비와 병원정보시스템의 접속표준 - ASTM protocol을 사용하는 ABGA의 POCT1-A2적용사례 중심으로 -)

  • Kim, Seon-Chil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.33-37
    • /
    • 2008
  • To keep the online medical records available to anyone without constraint of time and space, introducing EMR (Electronic medical record), which is a clinical support management system. The purpose of this study is to develop interface standard of clinical test device. Integration and sharing of medical information is faced with enormous obstacles because medical organizations and associated companies are separately developing the interface. I hope that multi-function management system with workstation concept is operated to efficiently transmit clinical device result data based on this study. Transfer of precise medical result data available for decision making will improve quality of health care service.

  • PDF

Ultra Fast Real-Time PCR for Detection of Babesia gibsoni as Point of Care Test

  • Yang, Yong-Sung;Mun, Myung-Jun;Yun, Young-Min
    • Journal of Veterinary Clinics
    • /
    • v.37 no.1
    • /
    • pp.23-27
    • /
    • 2020
  • Between May and November 2018, babesiosis was examined in 162 bloods samples obtained to an animal hospital in Jeju island for anemia and medical examination. Sixty-two of 162 (38.3%) were positive by PCR. The ultra fast real-time PCR test with blood directly analyzed without DNA extraction showed the same results. Accurate diagnosis, treatment and prognosis of babesiosis should be combined with clinical symptoms, blood tests, the babesia antibody test, and the PCR antigen test. Ultra fast real-time PCR, with these tests, is expected to be a point-of-care testing (POCT) for easy, fast and accurate diagnosis of babesiosis in the veterinary clinic.

High-accuracy quantitative principle of a new compact digital PCR equipment: Lab On An Array

  • Lee, Haeun;Lee, Cherl-Joon;Kim, Dong Hee;Cho, Chun-Sung;Shin, Wonseok;Han, Kyudong
    • Genomics & Informatics
    • /
    • v.19 no.3
    • /
    • pp.34.1-34.6
    • /
    • 2021
  • Digital PCR (dPCR) is the third-generation PCR that enables real-time absolute quantification without reference materials. Recently, global diagnosis companies have developed new dPCR equipment. In line with the development, the Lab On An Array (LOAA) dPCR analyzer (Optolane) was launched last year. The LOAA dPCR is a semiconductor chip-based separation PCR type equipment. The LOAA dPCR includes Micro Electro Mechanical System that can be injected by partitioning the target gene into 56 to 20,000 wells. The amount of target gene per wells is digitized to 0 or 1 as the number of well gradually increases to 20,000 wells because its principle follows Poisson distribution, which allows the LOAA dPCR to perform precise absolute quantification. LOAA determined region of interest first prior to dPCR operation. To exclude invalid wells for the quantification, the LOAA dPCR has applied various filtering methods using brightness, slope, baseline, and noise filters. As the coronavirus disease 2019 has now spread around the world, needs for diagnostic equipment of point of care testing (POCT) are increasing. The LOAA dPCR is expected to be suitable for POCT diagnosis due to its compact size and high accuracy. Here, we describe the quantitative principle of the LOAA dPCR and suggest that it can be applied to various fields.

Survey of Point-of-Care Testing Devices for Pre-hospital EMS Equipment of Glucometer on Local Area (지역 EMS의 현장검사 혈당측정기 사용에 대한 실태조사)

  • Byeong-Hyun, Kim;Dai-Hai, Choi;Gyoung-Yim, Ha
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.4
    • /
    • pp.220-228
    • /
    • 2022
  • Objective: glucometer is one of POCT(point-of-care testing) devices used by EMS. Accurate measurement value is important for patient decision making. Quality control is necessary for this, but most EMS are still using glucometer without quality control it. Therefore, management status and quality control status of glucometers used by 119 paramedics waswere investigated. Methods: 6 and 8 of glucometers and blood glucose test strips were submitted from 4 safety centers in 2010 and 8 safety centers in 2012, respectively. Glucometers submitted by local safety centers were analyzed in 2010 and 2012. The control glucometer, which was well managed at A University Hospital, was assumed to be accurate for at blood glucose measurement. Glucose values of various quality control materials control solutions were measured and analyzed using linear regression and Pearson's correlation test. Error rates were obtained via error tolerance range required by the 2011 ISO(International Organization for Standardization) guideline. For statistics, Excel and MedCalC programs were used. Results: mong 14 safety centers in the region, 4 centers(28.5%) in 2010 and 8 centers(57.1%) in 2012 submitted 6 and 8 glucometers. In the first evaluation in 2010, 2 out of 6(33.3%) glucometers were untestable due to error, and 45 out of 6(66.683.3%) blood glucose test strips' validity were expired. In the second evaluation in 2012, 1 out of 8(13.5%) glucometers were untestable due to lack of battery, and 2 out of 8(25%) blood glucose test strips' validity were expired. All correlation coefficients were above 0.989 in 2010 and above 0.997 in 2012. Error rates were generally high when using expired blood glucose test strips. Conclusion: Among 119 paramedics' guideline, quantity and operation status of POCT devices are well managed, but quality control is not. Therefore, it is necessary to add management status and quality control status of POCT devices to the EMS' field work guideline.

Recent Advances in a Microfluidic Paper-based Analytical Devices and its Point of Care Testing Applications (종이기반 미세유체 분석소자를 활용한 현장검사 기술과 그 응용)

  • Yoo, Yong Kyoung;Kim, Cheonjung;Lee, Junwoo;Lee, Jeong Hoon
    • Ceramist
    • /
    • v.21 no.3
    • /
    • pp.293-301
    • /
    • 2018
  • Paper-based analytical devices (${\mu}PAD$) are highly advantageous for portable diagnostic systems owing to their low costs and ease of use. ${\mu}PADs$ are considered as the best candidates for realizing the World Health Organization (WHO) ASSURED criteria: affordable, sensitive, specific, user-friendly, rapid and robust, equipment-free, and deliverable to end users. However, they have several limitations such as low sensitivity and accuracy. This article reports a mini review for a micro-fluidic paper-based analytical devices (${\mu}PAD$), especially for addressing low sensitivity and accuracy issues.

Development and evaluation of the multi-strip reader for point of care testing (현장검사용 멀티스트립 리더기의 개발 및 평가)

  • Kim, Jin;Jeon, Wooram;Park, Seoung Woo;Lee, Chang Youl;Lee, Da-Hyeon;Choi, In-Taek;Kim, Ju Yeon;Suh, In Bum
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.52-58
    • /
    • 2014
  • Point of care testing (POCT) is could be easily and economically performed and was widely used. In particular, the test items using immune chromatographic method has been conveniently used. But when an error occurs, we should reaffirmed the test results, but we could not reaffirm because the test line is disappeared as the time pass, and the test results are different between laboratory workers. Therefore, we developed multi-strip reader which can store images for the test results and can interpretate the test results automatically. Then we evaluated newly developed multi-strip reader for urine pregnancy test, the test results of the multi-strip reader was 100% matched with the previously results. Our newly developed multi-strip reader was convenient and economic, and will be widely used in many laboratories.

BioMEMS-EARLY DISEASE DETECTION (BioMEMS 기반의 조기 질병 진단 기술에 관한 연구)

  • Singh, Kanika;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2781-2784
    • /
    • 2007
  • Early detection of a disease is important to tackle treatment issues in a better manner. Several diagnostic techniques are in use, these days; for such purpose and tremendous research is going on to develop newer and newer methods. However, more work is required to be done to develop cheap and reliable early detection techniques. Micro-fluidic chips are also playing key role to deliver new devices for better health care. The present study focuses on a review of recent developments in the interrogation of different techniques and present state-of-the-art of microfluidic sensor for better, quick, easy, rapid, early, inexpensive and portable POCT (Point of Care testing device) device for a particular study, in this case, bone disease called osteoporosis. Some simulations of the microchip are also made to enable feasibility of the development of a blood-chip-based system. The proposed device will assist in early detection of diseases in an effective and successful manner.