• 제목/요약/키워드: point spread function

Search Result 157, Processing Time 0.032 seconds

Inertial Sensor Aided Motion Deblurring for Strapdown Image Seekers (관성센서를 이용한 스트랩다운 탐색기 훼손영상 복원기법)

  • Kim, Ki-Seung;Ra, Sung-Woong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.1
    • /
    • pp.43-48
    • /
    • 2012
  • This paper proposes a practical linear recursive robust motion deblurring filter using the inertial sensor measurements for strapdown image seekers. The angular rate information obtained from the gyro mounted on the missile is used to define the PSF(point spread function). Since the gyro output contains a unknown but bounded bias error. the motion blur image model can be expressed as the linear uncertain system. In consequence, the motion deblurring problem can be cast into the robust Kalman filtering which provides reliable state estimates even in the presence of the parametric uncertainty due to the gyro bias. Through the computer simulations using the actual IR scenes, it is verified that the proposed algorithm guarantees the robust motion deblurring performance.

Robert H. Koch's Work on Lightweight Medium-Aperture Mirrors

  • Holenstein, Bruce D.;Mitchell, Richard J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.79-84
    • /
    • 2012
  • After a visit by Peter Waddell from the University of Strathclyde, Glasgow, UK in 1991, Robert H. Koch launched a program at the University of Pennsylvania to build lightweight pneumatic membrane mirrors, initially for balloon flight observations where weight is at a premium. Mirror cells were fabricated from sizes 0.18 m to 1.77 m, and experiments conducted to characterize the mirror figure and stability. Most of the work stopped after Prof. Koch's retirement in 1996 until 2006 when the authors expressed an interest in building an array of medium-aperture portable telescopes. The program restarted in earnest at Gravic, Inc. in Malvern, PA in 2008 with Koch using his extensive observational astronomy experience to guide the fabrication of a fully operational 1.07 m membrane mirror telescope with an optical tube assembly weighing under 45 Kg. Residual wavefront aberrations remediation resulted in Koch and the authors investigating membrane tensioning techniques with different cell designs, active secondary wavefront correction, photometric algorithms for aberrated images, and the use of additional lightweight mirror substrates from the Alt-Az Initiative Group, such as foamed glass. The best result for the lightweight mirrors was a point spread function spot size of several arc seconds. A lightweight 1.6 m cast aluminum cell alt-az telescope was subsequently designed by Koch and the authors for prime focus use.

High-Speed NMR Imaging by Spiral -Scan Echo Planar Method (나선형 주사 방법에 의한 고속 NMR 영상화 연구)

  • Ahn, C.B.;Rew, C.Y.;Kim, J.H.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1985 no.06
    • /
    • pp.22-25
    • /
    • 1985
  • 본고에서, "나선형 주사 방법에 의한 고속 NMR 영상화" 방법을 제안하고 그에 따른 실험 결과를 보였다. 이것은 2차원 FID 영역을 나선형 궤적으로 스캐닝하며 데이타를 받을 수 있도록 경사 자계 파형 (gradient pulse)을 가하여 빠른 시간에 (수십 msec - 수초)내에 영상 정보를 얻어낸 후, 재구성 알고리즘을 씀으로써 영상을 얻어내는 방법이다. 이 방법의 장점은 첫째로 $T_2$ 감쇄에 의한 PSF (Point Spread Function)가 윈형 대칭으로 주어지므로 영상화 했을때 물체의 구조 식별이 기존의 EPI (Echo Planar Imaging) 방법에 비해서 선명하며, 둘째로 나선형 궤적을 구현하기 의한 경사 자계 파형에서 불연속 점을 없앰과 동시에 파형의 세기가 점차로 증가하는 형태이므로, 기존의, 파형 왜곡에 의해 영상에 미치는 영향을 최소화 할 수가 있으며, 세째로 나선형 스캔을 사이 사이에 끼워 넣는 방법을 씀으로써 해상도를 향상시킬 수가 있다.

  • PDF

Software of Slit-Viewing Camera Module for IGRINS (Immersion GRating INfrared Spectrograph)

  • Lee, Hye-In;Pak, Soojong;Lee, Jae-Joon;Mace, Gregory;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.66.1-66.1
    • /
    • 2016
  • We developed an observation control software for the IGRINS (Immersion Grating Infrared Spectrograph) silt-viewing camera module, which points the astronomical target onto the spectroscopy slit and sends tracking feedbacks to the telescope control system. The point spread function (PSF) is not always symmetric. In addition, bright targets are easily saturated and shown as a donut shape. It is not trivial to define and find the center of the asymmetric PSF especially on a slit mask. We made a center balancing algorithm (CBA) following the concept of median. The CBA derives the expected center position along the slit-width axis by referencing the stray flux ratios of both upper and lower sides of the slit. We compared efficiencies of the CBA and those of a two-dimensional Gaussian fitting (2DGA) through simulations from observation images in order to evaluate the center finding algorithms. Both of the algorithms are now applied in observation and users can select the algorithm.

  • PDF

Photometry of MIRIS Paschen-α blobs detected in Cepheus

  • Kim, Il-Joong;Pyo, Jeonghyun;Jeong, Woong-Seob;Park, Won-Kee;Kim, Min Gyu;Lee, Dukhang;Moon, Bongkon;Park, Sung-Joon;Park, Youngsik;Lee, Dae-Hee;Han, Wonyong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.55.3-55.3
    • /
    • 2016
  • By comparing MIRIS Paschen-${\alpha}$ ($Pa{\alpha}$) Galactic Plane Survey (MIPAPS) data with Anderson's H II region catalog (the most complete Galactic H II region catalog up to date), we confirmed $Pa{\alpha}$ detections from ~50% of the H II region candidates in Cepheus (Galactic longitude from $+96^{\circ}$ to $116^{\circ}$). The detection of the hydrogen recombination line identifies these candidates as clear H II regions. If we extend this result to the whole plane, more than 1000 candidates are expected to be identified as H II regions. In this contribution, we present the results of quantitative estimations (brightness, size, etc.) for the $Pa{\alpha}$ blobs detected in Cepheus. To obtain intensity of $Pa{\alpha}$ emission line, we perform background and point spread function (PSF) matching between two filter images (line and continuum filters) as well as flux calibration.

  • PDF

Iterative Unsharp Mask Filter for Digital Auto-Focusing (디지털 자동초점을 위한 반복적 Unsharp Mask 필터)

  • Shin, Jeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.5
    • /
    • pp.145-152
    • /
    • 2010
  • This paper presents a digital auto-focusing algorithm using iterative unsharp mask filter. The proposed digital auto-focusing algorithm has the advantage of low computational complexity because it uses a simple filter instead of calculating the point spread function for the estimation of image degradation. The proposed iterative algorithm can control the number of iterations for image restoration according to the objective and the subjective criterion. We show that the proposed algorithm is mathematically equivalent to the conventional image restoration. Finally, in order to evaluate the performance of the proposed algorithm, various experiments are performed so that the proposed algorithm can provide good results in the sense of subjective and objective views.

Optical Tracking of Three-Dimensional Brownian Motion of Nanoparticles

  • Choi C. K.;Kihm K.D.
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.3-19
    • /
    • 2005
  • Novel optical techniques are presented for three-dimensional tracking of nanoparticles; Optical Serial Sectioning Microscopy (OSSM) and Ratiometric Total Internal Reflection Fluorescent Microscopy (R-TIRFM). OSSM measures optically diffracted particle images, the so-called Point Spread Function (PSF), and dotermines the defocusing or line-of-sight location of the imaged particle measured from the focal plane. The line-of-sight Brownian motion detection using the OSSM technique is proposed in lieu of the more cumbersome two-dimensional Brownian motion tracking on the imaging plane as a potentially more effective tool to nonintrusively map the temperature fields for nanoparticle suspension fluids. On the other hand, R-TIRFM is presented to experimentally examine the classic theory on the near-wall hindered Brownian diffusive motion. An evanescent wave field from the total internal reflection of a 488-nm bandwidth of an argon-ion laser is used to provide a thin illumination field of an order of a few hundred nanometers from the wall. The experimental results show good agreement with the lateral hindrance theory, but show discrepancies from the normal hindrance theory. It is conjectured that the discrepancies can be attributed to the additional hindering effects, including electrostatic and electro-osmotic interactions between the negatively charged tracer particles and the glass surface.

  • PDF

Correlation between mergers and AGN activity : a case study with MARK 478

  • Hong, Ju-Eun;Im, Myung-Shin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.34.1-34.1
    • /
    • 2010
  • Studies suggest that activities in luminous AGNs, residing mostly in early-type galaxies, are triggered by merging. However, the observational evidence for the connection between mergers and AGN activity is not clear yet because tracer of the past merging activities such as tidal tail, shell are often too faint. To see if we can reveal the merging features with a small telescope, we observed an AGN, MARK 478, at z=0.077 with long exposure time (7550 seconds) in V filter at Maidanak observatory. Our 2-D fitting analysis shows that the host galaxy of MARK 478 has the bulge to the total luminosity ratio of 0.3. And the residual image, after subtracting point spread function (PSF), bulge and disk components, shows that the host galaxy has an arm-like feature that could be a spiral arm or a feature from minor merging. We also show that the structural parameters obtained from our 2-D fitting match well with those derived from HST image. The promising result suggests that studies of low redshift AGN host galaxies are possible with data from a small telescope. In order to allow a statistical analysis, we hope to expand our sample size in future.

  • PDF

A Study on Iris Image Restoration Using Focus Value of Iris Image (영상의 초점값을 이용한 홍채 영상 복원 연구)

  • Kang, Byung-Jun;Park, Kang-Ryoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.781-784
    • /
    • 2005
  • 홍채 인식은 동공과 흰자위 사이에 존재하는 도넛 모양의 홍채 패턴(Iris pattern)을 이용하여 자신인지 타인인지 판별하는 매우 신뢰도가 높은 생체인식기술 가운데 하나이다. 홍채 인식은 홍채 영상의 홍채 패턴으로부터 홍채 코드(Iris code)를 추출하여 인식하기 때문에 좋은 질의 홍채영상을 취득하는 것은 정확한 홍채 인식을 위해서 매우 중요하다. 이러한 홍채 영상의 질을 결정하는 중요한 요소 가운데 하나가 초점(focus)이다. 초점이 맞지 않아 흐려진(blurring) 영상은 홍채 인식에서 자신임에도 불구하고 타인으로 인식하는 FRR(false reject error)를 증가시킨다. 홍채 인식 시스템의 카메라는 고정 초점 방식과 가변 초점 방식이 있다. 고정 초점 방식은 초점렌즈가 고정되어 있어서 초점이 맞지 않는 영상을 취득할 경우 사용자에게 다시 요구하여 입력받도록 한다. 이는 사용자에게 불편을 초래한다. 가변 초점 방식은 사용자와의 거리를 측정하여 초점렌즈를 움직여서 초점이 잘 맞은 선명한 영상을 얻는다. 하지만, 초점렌즈를 움직이기 위해서 사용자와의 거리를 측정하는 센서와 초점렌즈를 움직이는 모터등과 같은 부가 장비가 필요하다. 따라서 카메라의 부피가 커지고, 가격이 상승하게 되는 문제점이 있다. 그리므로 본 논문은 고정 초점 카메라를 사용하여 부가 장비 없이 홍채 영상 복원 알고리즘을 사용하여 소프트웨어적으로 초점이 맞지 않아 흐려진 영상을 처리하는 방법을 제안한다. 본 논문은 초점값을 이용하여 열화(degradation)의 정도를 판단하였으며, 초점값(focus value)에 따라 점확산함수(point spread function)를 설계하여 홍채영상을 복원하였다.

  • PDF

SURFACE PHOTOMETRY OF NGC4419

  • CHOI JEONG TAE;ANN HONG BAE;LEE HYUNG MOK
    • Journal of The Korean Astronomical Society
    • /
    • v.26 no.1
    • /
    • pp.33-45
    • /
    • 1993
  • We have conducted surface photometry of a spiral galaxy NGC4419, by making use of photographic plates in U, B, V and R-bands taken by 105cm Schmidt Camera at Kiso Observatory. Two dimensional surface brightness distributions as well as luminosity profiles along the major axis are examined in detail to decipher the morphological properties of the galaxy. Analysis of the color distributions of NGC4419 shows that B-V and U-B colors remain constant throughout the galaxy with a weak trend of blue bulge in B-V color. The blue bulge might indicate an active star formation in the nucleus of NGC4419. For a quantitative analysis of the luminosity distribution of NGC4419, the observed luminosity profiles are decomposed into bulge and disk components, assuming the bulge component to follow de Vaucouleurs $\gamma^{1/4}-law$ while the disk component is assumed to be exponential. The fitting generally fails at the central part and at the shoulder near r = 15' where bulge and disk components overlap. The failure at the central part cannot be attributed wholly by the seeing disk since the core-radius of the central plateau is much larger than the width of point spread function. The failure at shoulder could be due to the luminosities from the spiral arms.

  • PDF