• Title/Summary/Keyword: point specificity

검색결과 231건 처리시간 0.024초

입원 환자 영양검색 지표 개발 (Development of Nutrition Screening Index for Hospitalized Patients)

  • 김수안;김소연;손정민
    • 대한지역사회영양학회지
    • /
    • 제11권6호
    • /
    • pp.779-784
    • /
    • 2006
  • Several studies about hospital malnutrition have been reported that about more than 40% of hospitalized patients are having nutritional risk factors and hospital malnutrition presents a high prevalence. People in a more severe nutritional status ended up with a longer length of hospital stay and higher hospital cost. Nutrition screening tools identify individuals who are malnourished or at risk of becoming malnourished and who may benefit from nutritional support. For the early detection and treatment of malnourished hospital patients , few valid screening instruments fur Koreans exist. Therefore, the aim of this study was to develop a simple, reliable and valid malnutrition screening tool that could be used at hospital admission to identify adult patients at risk of malnutrition using medical electrical record data. Two hundred and one patients of the university affiliated medical center were assessed on nutritional status and classified as well nourished, moderately or severely malnourished by a Patient-Generated subjective global assessment (PG-SGA) being chosen as the 'gold standard' for defining malnutrition. The combination of nutrition screening questions with the highest sensitivity and specificity at prediction PG-SGA was termed the nutrition screening index (NSI). Odd ratio, and binary logistic regression were used to predict the best nutritional status predictors. Based on regression coefficient score, albumin less than 3.5 g/dl, body mass index (BMI) less than $18.5kg/m^2$, total lymphocyte count less than 900 and age over 65 were determined as the best set of NSI. By using best nutritional predictors receiver operating characteristic curve with the area under the curve, sensitivity and 1-specificity were analyzed to determine the best optimal cut-off point to decide normal or abnormal in nutritional status. Therefore simple and beneficial NSI was developed for identifying patients with severe malnutrition. Using NSI, nutritional information of the severe malnutrition patient should be shared with physicians and they should be cared for by clinical dietitians to improve their nutritional status.

Development of a Novel Multiple Cross-Linking Spiral Amplification for Rapid and Sensitive Detection of HPV16 DNA

  • Zhang, Donghong;Liu, Dongliang;Liu, Bing;Ma, Xiulan
    • Journal of Microbiology and Biotechnology
    • /
    • 제31권4호
    • /
    • pp.610-620
    • /
    • 2021
  • There has been increasing interest in the head and neck squamous cell carcinoma (HNSCC) that is caused by high-risk human papillomavirus (HR-HPV) and has posed a significant challenge to Otolaryngologists. A rapid, sensitive, and reliable method is required for the detection of HR-HPV in clinical specimens to prevent and treat HPV-induced diseases. In this study, a multiple cross-linking spiral amplification (MCLSA) assay was developed for the visual detection of HPV-16. In the MCLSA assay, samples were incubated under optimized conditions at 62℃ for 45 min, and after mixing with the SYBR Green I (SGI) dye, the positive amplicons showed bright green fluorescence while the negative amplicons exhibited no obvious change. The specificity test revealed that the developed MCLSA technique had high specificity and could effectively distinguish all five HPV-16 strains from other pathogenic microorganisms. In terms of analytical sensitivity, the limit of detection (LoD) of MCLSA assay was approximately 5.4 × 101 copies/tube, which was 10-fold more sensitive than loop-mediated isothermal amplification (LAMP) and RT-PCR. The detection results of laryngeal cancer specimens collected from 46 patients with suspected HPV infection in the Liaoning region demonstrated that the positive detection rates of MCLSA and hybridized capture 2 kit were 32.61% (15/46). The true positive rate of the MCLSA assay was higher than that of RT-PCR (100% vs. 93.33%) and LAMP (100% vs. 86.67%). Therefore, the MCLSA assay developed in the present study could be a potentially useful tool for the point-of-care (PoC) diagnosis of HR-HPV, especially in resource-limited countries.

Malaria Prevalence in a Low Transmission Area, Jazan District of Southwestern Saudi Arabia

  • Hawash, Yousry;Ismail, Khadiga;Alsharif, Khalaf;Alsanie, Walaa
    • Parasites, Hosts and Diseases
    • /
    • 제57권3호
    • /
    • pp.233-242
    • /
    • 2019
  • Detailed description of malaria in low transmission areas is crucial for elimination. The current study aimed to provide a comprehensive description for malaria transmission in Jazan, a low transmission district, southwestern Saudi Arabia. Patients at a tertiary care hospital were recruited in our study between August 2016 and September 2018. Malaria diagnosis was performed through a species-specific nested polymerase chain reaction (nested PCR), microscopy and Paramax-$3^{TM}$ rapid detection test (RDT). Malaria was detected in 30 patients by the PCR, with point prevalence of 10.9%. Of these malaria infections, 80% was imported, 26.6% was asymptomatic and 23.3% was sub-microscopic. Malaria was reported throughout the year, with February/March and September/October peaks. Infection was significantly more in males than in females (P=0.01). Likewise, infections were detected more in febrile than in non-febrile patients (P=0.01). Adult aged 15-24 years, fever and travel were identified as high-risk factors. Malaria was primarily attributed to Plasmodium falciparum mono-infections, followed by P. vivax mono-infections and lastly to falciparum/vivax mixed infections accounting 76.6%, 16.6%, and 6.6% of PCR-confirmed malaria cases, respectively. The nested PCR was superior to the smear microscopy (sensitivity 76.6%; specificity 100%) and the RDT (sensitivity 83.3%, specificity 94.2%). The overall percent agreement between microscopy and the RDT was 92.7% (kappa=0.63). High proportion of imported malaria including sub-microscopic and sub-patent cases were described. We suggest that incorporation of molecular tool into the conventional malaria diagnosis is beneficial in Jazan district.

Relationships of the Vitamin D and Platelet Indices in Sjögren's Syndrome

  • Gunay, Nahide Ekici;Bugday, Irfan;Akalin, Tayfun
    • 대한임상검사과학회지
    • /
    • 제50권4호
    • /
    • pp.484-491
    • /
    • 2018
  • Primer $Sj{\ddot{o}}gren's$ Syndrome (pSS) is an autoimmune/inflammatory illness. The platelet indices (PIs) indicate the inflammatory response and activity/severity of many diseases. A vitamin D deficiency is accompanied by the increased tendency of autoimmune diseases. This study investigated whether the vitamin D levels are related to the altered platelet indices in pSS. A total of 261 individuals were included in this analytical cross-sectional study. The laboratory data of pSS patients were evaluated and the relationship between the PIs and vitamin D status was examined. According to these findings, in patients with pSS, the vitamin D levels were lower than the healthy control group (P<0.05). The vitamin D levels were negatively associated with PDW (P=0.012), but positively correlated with PCT (P<0.001). The cut-off point was obtained with receiver operating characteristics (ROC) curves for PDW: 12.53 (AUC 0.921, sensitivity 90%, specificity 85%), for PCT; 0.29 (AUC 0.660, sensitivity 68%, specificity 55%). In multivariate linear regression analysis, the most significant parameters for the effects of PDW are the following: vitamin D (${\beta}=-0.373$; t=-2.626; sig.=0.013) and plateletcrit (${\beta}=-0.308$; t=-2.13; sig.=0.040). A vitamin D deficiency may be accompanied by changes in PIs in pSS. A higher PDW and lower PCT supports the underlying inflammation, which may be vitamin D related useful parameters to consider in approaching to pSS.

Development and Clinical Evaluation of a Rapid Diagnostic Test for Yellow Fever Non-Structural Protein 1

  • Kim, Yeong Hoon;Kim, Tae-Yun;Park, Ji-Seon;Park, Jin Suk;Lee, Jihoo;Moon, Joungdae;Chong, Chom-Kyu;Neves, Ivan Junior;Ferry, Fernando Raphael;Ahn, Hye-Jin;Bhatt, Lokraj;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • 제57권3호
    • /
    • pp.283-290
    • /
    • 2019
  • A rapid diagnostic test (RDT) kit was developed to detect non-structural protein 1 (NS1) of yellow fever virus (YFV) using monoclonal antibody. NS1 protein was purified from the cultured YFV and used to immunize mice. Monoclonal antibody to NS1 was selected and conjugated with colloidal gold to produce the YFV NS1 RDT kit. The YFV RDTs were evaluated for sensitivity and specificity using positive and negative samples of monkeys from Brazil and negative human blood samples from Korea. Among monoclonal antibodies, clones 3A11 and 3B7 proved most sensitive, and used for YFV RDT kit. Diagnostic accuracy of YFV RDT was fairly high; Sensitivity was 0.0% and specificity was 100% against Dengue viruses type 2 and 3, Zika, Chikungunya and Mayaro viruses. This YFV RDT kit could be employed as a test of choice for point-of-care diagnosis and large scale surveys of YFV infection under clinical or field conditions in endemic areas and on the globe.

치면열구전색치아의 미세누출 평가를 위한 Swept-Source Optical Coherence Tomography의 타당도 평가 (Evaluation of sealant microleakage using Swept-Source Optical Coherence Tomography)

  • 남상미;구혜민;이은송;김백일
    • 대한치과의사협회지
    • /
    • 제56권12호
    • /
    • pp.686-694
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the validity of swept-source optical coherence tomography (SS-OCT) for detecting sealant microleakage. Materials and Methods: A total of 31 extracted sound human molar, assigned as suitable for sealant application, were chosen and divided into two groups: (1) no microleakage group and (2) microleakage group by applying sealant using the different methods. All specimens were immersed in 1% methylene blue for 24 h and sectioned to confirm the absence or presence of sealant microleakage as a gold standard method. Subsequently, all the sectioned specimens were digitally photographed using a microscope with a magnification of ${\times}50$. Presence of microleakage was evaluated on a 2-point rating scale. The association of histological method with conventional methods (visual and tactile assessment) and SS-OCT was assessed using a chi-squared test. The intra- and inter-examiner reliability was calculated using Cohen's Kappa. Results: The SS-OCT showed a sensitivity of 0.73 and a specificity of 1.00, while visual and tactile assessment showed a sensitivity of 0.67 and a specificity of 0.86. The inter-examiner reliability of SS-OCT was 0.79, whereas that of the visual and tactile assessment was 0.53. Conclusions: SS-OCT can be used to non-invasively detect sealant microleakage and to monitor pit and fissure sealant in the clinics.

  • PDF

Development of Enzymatic Recombinase Amplification Assays for the Rapid Visual Detection of HPV16/18

  • Ning Ding;Wanwan Qi;Zihan Wu;Yaqin Zhang;Ruowei Xu;Qiannan Lin;Jin Zhu;Huilin Zhang
    • Journal of Microbiology and Biotechnology
    • /
    • 제33권8호
    • /
    • pp.1091-1100
    • /
    • 2023
  • Human papillomavirus (HPV) types 16 and 18 are the major causes of cervical lesions and are associated with 71% of cervical cancer cases globally. However, public health infrastructures to support cervical cancer screening may be unavailable to women in low-resource areas. Therefore, sensitive, convenient, and cost-efficient diagnostic methods are required for the detection of HPV16/18. Here, we designed two novel methods, real-time ERA and ERA-LFD, based on enzymatic recombinase amplification (ERA) for quick point-of-care identification of the HPV E6/E7 genes. The entire detection process could be completed within 25 min at a constant low temperature (35-43℃), and the results of the combined methods could be present as the amplification curves or the bands presented on dipsticks and directly interpreted with the naked eye. The ERA assays evaluated using standard plasmids carrying the E6/E7 genes and clinical samples exhibited excellent specificity, as no cross-reaction with other common HPV types was observed. The detection limits of our ERA assays were 100 and 101 copies/µl for HPV16 and 18 respectively, which were comparable to those of the real-time PCR assay. Assessment of the clinical performance of the ERA assays using 114 cervical tissue samples demonstrated that they are highly consistent with real-time PCR, the gold standard for HPV detection. This study demonstrated that ERA-based assays possess excellent sensitivity, specificity, and repeatability for HPV16 and HPV18 detection with great potential to become robust diagnostic tools in local hospitals and field studies.

Potential impact of metal crowns at varying distances from a carious lesion on its detection on cone-beam computed tomography scans with several protocols

  • Matheus Barros-Costa;Eduarda Helena Leandro Nascimento;Iago Filipe Correia-Dantas;Matheus L. Oliveira;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • 제54권1호
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: This study evaluated the impact of artifacts generated by metal crowns on the detection of proximal caries lesions in teeth at various distances using cone-beam computed tomography (CBCT). Additionally, the diagnostic impacts of tube current and metal artifact reduction (MAR) were investigated. Materials and Methods: Thirty teeth were arranged within 10 phantoms, each containing 1 first premolar, 1 second premolar, and 1 second molar. A sound first molar (for the control group) or a tooth with a metal crown was placed. Of the 60 proximal surfaces evaluated, 15 were sound and 45 exhibited enamel caries. CBCT scans were acquired using an OP300 Maxio unit (Instrumentarium, Tuusula, Finland), while varying the tube current (4, 8, or 12.5 mA) and enabling or disabling MAR. Five observers assessed mesial and distal surfaces using a 5-point scale. Multi-way analysis of variance was employed for data comparison, with P<0.05 indicating statistical significance. Results: The area under the curve (AUC) varied from 0.40 to 0.60 (sensitivity: 0.28-0.45, specificity: 0.44-0.80). The diagnostic accuracy was not significantly affected by the presence of a metal crown, milliamperage, or MAR(P>0.05). However, the overall AUC and specificity were significantly lower for surfaces near a crown (P<0.05). Conclusion: CBCT-based caries detection was not influenced by the presence of a metal crown, variations in milliamperage, or MAR activation. However, the diagnostic accuracy was low and was further diminished for surfaces near a crown. Consequently, CBCT is not recommended for the detection of incipient caries lesions.

양릉천 저주파 전침자극이 $CCl_4$로 유발된 흰쥐의 간 손상에 미치는 영향 (Hepatoprotective effect of electroacupuncture at GB34 (Yangreungcheon) in $CCl_4$-intoxicated rats)

  • 채충헌;안택원;임윤경
    • Korean Journal of Acupuncture
    • /
    • 제25권2호
    • /
    • pp.211-224
    • /
    • 2008
  • Objectives : To investigate the effect of electro-acupuncture (EA) at GB34 on hepatotoxicity in $CCl_4$-intoxicated rats. Methods : Rats were injected with $CCl_4$ and treated with acupuncture or 2 Hz electro-acupuncture (EA) at left GB34 three times a week for 10 weeks. A non-acupoint in left gluteal area was selected as a sham point. To estimate the effects of EA on hepatotoxicity in rats, body weight, liver weight and liver index were measured, and biochemical assays for serum ALT, AST, ALP and total cholesterol, and hematological analysis for RBC, WBC, PLT, hemoglobin, lymphocytes, neutrophils and monocytes, and histology analysis of liver tissue were performed. Results : 1. Lymphocyte level in blood was significantly decreased by $CCl_4$-intoxication and significantly increased by acupuncture and 2 Hz EA at left GB34. 2. Neutrophill and monocyte level in blood was increased by $CCl_4$-intoxication and significantly reduced by acupuncture and 2 Hz EA at left GB34. 3. Acupuncture and 2 Hz EA at left GB34 significantly reduced serum ALT and AST which were increased by $CCl_4$-intoxication. 4. EA at GB34 significantly reduced serum ALT and AST as compared with EA at sham point in $CCl_4$-intoxicated rat. 5. No significant difference was found between the effects of acupuncture and that of 2 Hz EA on $CCl_4$-induced liver damage in rats. Conclusions : 2 Hz EA at GB34 has hepatoprotective effects on $CCl_4$-induced liver damage in rats and the point-specificity of GB34 may be involved in these effects.

  • PDF

한국 장년 성인의 과체중 예방을 위한 식생활 간이평가표 개발 (The Development of a Simple Evaluation Questionnaire for Screening the Overweight-type Dietary Pattern in 30 to 49 Year Old Adults)

  • 박영숙;한재라;이정원;조한석;구재옥;김정희;윤진숙
    • 대한지역사회영양학회지
    • /
    • 제7권4호
    • /
    • pp.495-505
    • /
    • 2002
  • A study was performed to develop as a screening tool the Simple Evaluation Questionnaire for Screening the Over-weight-type Dietary Pattern in 30 to 49 Year Old Adults. We used the data from the 30 to 49 year old subjects who participated in the three surveys - the health behavior survey, the dietary habit survey and the food intake survey - as the National Health and Nutrition Survey 1998. The 3,598 adults were classified into to two body fatness groups of normal (including underweight) and overweight (including obese) on the basis of their relative body weight (RBW) When comparing variables between the two groups, significant differences were found in gender, education, job, employment status, perceived health status, sadness / depression state, stress level, age, number of diseases, age when overweightedness started, maximum body weight, sleep length, drinking pattern (yes/no) , amount of alcoholic drinks, frequency of intoxication or drunkeness, amount of alcoholic drinks when drunk, intensity of exercise, frequency of exercise, exercise duration, skipped meals, small meals and drug supplements. In terms of food intake, there were significant differences in the daily food intake in terms of breakfast, dinner, daily kimchi and dairy products. In terms of mealtimes, we found differences in the amount of cooked rice at breakfast, kimchi at lunch, soup / kuk at dinner, fresh vegetables for snacks, fried foods for snacks between breakfast and lunch, and fruits /juices for snacks between lunch and dinner. After developing questions with indicators and analyzing the indicators by logistic regression analysis three times, we chose 10 questions for a simple evaluation of dietary patterns for the overweight-type category in order to give one point each. Among them we selected two questions to add one additional point and one question to add two additional points. The average scores of the overweight and normal groups, as shown by the developed questionnaire, were $5.97 \pm 2.36 \pm 7.36 \pm 2.21$, respectively. A score of seven points was selected as the cut-off point. We examined the sensitivity, specificity and positive predictive value of the questionnaire to the results of 67%, 59% and 62%, respectively.