• Title/Summary/Keyword: point defects

Search Result 499, Processing Time 0.026 seconds

The effect of PVT process parameters on the resistance of HPSI-SiC crystal (PVT 공법의 공정 변수가 고순도 반절연 SiC 단결정의 저항에 미치는 영향)

  • Jun-Hyuck Na;Min-Gyu Kang;Gi-Uk Lee;Ye-Jin Choi;Mi-Seon Park;Kwang-Hee Jung;Gyu-Do Lee;Woo-Yeon Kim;Won-Jae Lee
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.34 no.2
    • /
    • pp.41-47
    • /
    • 2024
  • In this study, the resistance characteristics of semi-insulating SiC single crystals grown using the PVT method were investigated, considering the purity level of SiC source powders used in PVT growth and the cooling procedure after crystal growth. Two β-SiC powders with different purities were employed, and the cooling rate after growth was adjusted to achieve various resistance values. 4-inch HPSI-SiC ingots were grown using the PVT method, utilizing SiC powders with low nitrogen concentration and relatively high nitrogen concentration. These ingots were then subjected to different cooling procedures to modify the cooling rate. Transmission/absorption spectra and crystal quality of the grown crystals were analyzed through UV/VIs/NIR spectroscopy and X-ray rocking curve analysis, respectively. Additionally, electrical properties were investigated through non-contact resistivity analysis to identify the dominant factors influencing resistivity properties.

Prognosis of Blade Icing of Rotorcraft Drones through Vibration Analysis (진동분석을 통한 회전익 드론의 블레이드 착빙 예지)

  • Seonwoo Lee;Jaeseok Do;Jangwook Hur
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Weather is one of the main causes of aircraft accidents, and among the phenomena caused by weather, icing is a phenomenon in which an ice layer is formed when an object exposed to an atmosphere below a freezing temperature collides with supercooled water droplets. If this phenomenon occurs in the rotor blades, it causes defects such as severe vibration in the airframe and eventually leads to loss of control and an accident. Therefore, it is necessary to foresee the icing situation so that it can ascend and descend at an altitude without a freezing point. In this study, vibration data in normal and faulty conditions was acquired, data features were extracted, and vibration was predicted through deep learning-based algorithms such as CNN, LSTM, CNN-LSTM, Transformer, and TCN, and performance was compared to evaluate blade icing. A method for minimizing operating loss is suggested.

Transparent Electrode Characteristics of SnO2/AgNi/SnO2 Multilayer Structures (SnO2/AgNi/SnO2 다중층 구조의 투명 전극 특성)

  • Min-Ho Hwang;Hyun-Yong Lee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.5
    • /
    • pp.500-506
    • /
    • 2024
  • The transparent electrode characteristics of the SnO2/AgNi/SnO2 (OMO) multilayer structures prepared by sputtering were investigated according to the annealing temperature. Ni-doped Ag of various compositions was selected as the metal layer and heat treatment was performed at 100~300℃ to evaluate the thermal stability of the metals. The manufactured OMO multilayer structures were heat treated for 6 hours at 400~600℃ in an N2 atmosphere. The structural, electrical, and optical properties of the OMO structures before and after annealing were evaluated and analyzed using a UV-VIS spectrophotometer, 4-point probe, XPS, FE-SEM, etc. OMO with Ni-doped Ag shows improved performance due to the reduction of structural defects of Ag during annealing, but OMO structure with pure Ag shows degradation characteristics due to Ag diffusion into the oxide layer during high-temperature annealing. The figure of merit (FOM) of SnO2/Ag/SnO2 was highest at room temperature and gradually decreased as the heat treatment temperature increased. On the other hand, the FOM value of SnO2/AgNi/SnO2 mostly showed its maximum value at high temperature(~550℃). In particular, the FOM value of SnO2/Ag-Ni (3.2 at%)/SnO2 was estimated to be approximately 2.38×10-2-1. Compared to transparent electrodes made of other similar materials, the FOM value of the SnO2/Ag-Ni (3.2 at%)/SnO2 multilayer structure is competitive and is expected to be used as an alternative transparent conductive electrode in various devices.

Properties of Photoluminescence and Growth of CdIn2Te4 Single Crystal by Bridgeman method (Bridgeman법에 의한 CdIn2Te4 단결정 성장과 광발광 특성)

  • Moon, Jong-Dae
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.273-281
    • /
    • 2003
  • A stoichiometric mixture for $CdIn_2Te_4$ single crystal was prepared from horizontal electric furnace. The $CdIn_2Te_4$ single crystal was grown in the three-stage vertical electric furnace by using Bridgeman method. The quality of the grown crystal has been investigated by the x-ray diffraction and the photoluminescence measurements. The (001) growth plane of oriented $CdIn_2Te_4$ single crystal was confirmed from back-reflection Laue patterns. The carrier density and mobility of $CdIn_2Te_4$ single crystal measured with Hall effect by van der Pauw method are $8.61{\times}10^{16}\;cm^{-3}$ and $242\;cm^2/V{\cdot}s$ at 293 K, respectively. The temperature dependence of the energy band gap of the $CdIn_2Te_4$ single crystal obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)=1.4750\;eV-(7.69{\times}10^{-3}\;eV)T^2/(T+2147)$. After the as-grown $CdIn_2Te_4$ single crystal was annealed in Cd-, In-, and Te-atmospheres, the origin of point defects of $CdIn_2Te_4$ single crystal has been investigated by the photoluminescence(PL) at 10 K. The native defects of $V_{Te}$, $Cd_{int}$, and $V_{Cd}$, $Te_{int}$ obtained by PL measurements were classified as a donors or acceptors type. And we concluded that the heat-treatment in the Cd-atmosphere converted $CdIn_2Te_4$ single crystal to an optical n-type. Also, we confirmed that In in $CdIn_2Te_4$ did not form the native defects because In in $CdIn_2Te_4$ single crystal existed in the form of stable bonds.

Minimally invasive cardiac surgery with the partial mini-sternotomy in children (소아연령군에서의 부분흉골소절개를 통한 최소침투적심장수술)

  • 이정렬;임홍국;성숙환;김용진;노준량;서경필
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.466-471
    • /
    • 1998
  • Purpose: The safety and efficacy of minimally invasive techniques in congenital heart surgery were tested in this study. Materal and method: Between July 1997 and November 1997, a total of 46 children were underwent minimally invasive cardiac operations at Seoul National University Children's Hospital. Age and body weight of the patients averaged 34.6${\pm}$41.8 (Range: 1∼148) months and 14.5${\pm}$9.9(Range: 3.0∼40.0) kg, respectively. Twenty eight patients were male. Preoperative surgical indications included 15 atrial septal defects, 25 ventricular septal defects, 1 foreign body in aorta, 3 partial atrioventricular septal defects, 1 total anomalous pulmonary venous connection(cardiac type), and 1 tetralogy of Fallot. After creating a small lower midline skin incision starting as down as possible from the sternal notch, a vertical midline sternotomy extended from xyphoid process to the level of the second intercostal space, where one of the T-, J-, I- or inverted C-shaped lower lying mini-sternotomy was completed with a creation of unilateral right or bilateral trap door sternal opening. A conventional direct aortic and bicaval cannulation was routine. Result: A mean length of skin incision was 6.1${\pm}$1.0(range: 4.0∼9.0) cm. A mean distance between the suprasternal notch and the upper most point of the skin incision was 4.0${\pm}$1.1 (range: 2.0∼7.0) cm. Mean cardiopulmonary bypass time, aortic cross-clamp time, and the operation time were 62.9${\pm}$20.0(range: 28∼147), 29.8${\pm}$12.8(range: 11∼79), and 161.1${\pm}$34.5 (range: 100-250) minutes. A mean total amount of postoperative blood transfusion was 71.0${\pm}$68.1 (range: 0∼267) cc. All patients were extubated mean 11.3${\pm}$13.8(range: 1∼73) hours after operation. A mean total amount of analgesics used was 0.8${\pm}$1.8(range: 0∼9) mg of morphine. The mean duration of stay in intensive care unit and hospital stay were 35.0${\pm}$32.2 (range: 10∼194) hours and 6.2${\pm}$2.0(range: 3∼11) days. There were no wound complications and hospital deaths. Conclusion: This short-term experience disclosed that the minimally invasive technique can be feasibly applied in a selected group of congenital heart disease as well as is cosmetically more attractive approach.

  • PDF

Multi-Point Optical Fiber Grating Strain Sensor System (광섬유 격자 다중화 스트레인 센서 시스템)

  • Lee, Yong-Wook;Jung, Jae-Hoon;Chung, Seung-Hwan;Lee, Byoung-Ho;Kim, Nam-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.147-151
    • /
    • 2001
  • An optical fiber sensor is capable of nondestructive measurement of a structure and it has an advantage of the immunity to electromagnetic interference because light is not affected by electromagnetic wave. In addition, if optical fibers are buried in an object like a concrete, this sensor tan analyze defects and physical status of the object without disassembling it. Especially, the fiber Bragg grating sensor is a promising optical fiber sensor capable of nondestructive test of such an object. A fiber Bragg grating has the characteristics of reflecting or blotting light of a specific wavelength. If we apply physical quantity like strain to the fiber Bragg grating, the center wavelength of the reflected light is shifted and then we can find the physical quantity applied to the fiber Bragg grating by measuring the center wavelength shift of the reflected light. The fiber Bragg grating sensor capable ot static and dynamic strain measurement is being used in health-monitoring of buildings, structures, etc. Recently increasing is interest in dynamic strain measurement inevitable to the civil structures such as roads and bridges. In this study we implemented the optical fiber sensor system which can measure dynamic strain at multiple points using Fabry-Perot wavelength demodulation. And we measured the static and dynamic strain using this sensor system with a test structure(cantilever). Measurement results were similar to those obtained with the conventional electrical measurement methods.

  • PDF

Implementation of Massive FDTD Simulation Computing Model Based on MPI Cluster for Semi-conductor Process (반도체 검증을 위한 MPI 기반 클러스터에서의 대용량 FDTD 시뮬레이션 연산환경 구축)

  • Lee, Seung-Il;Kim, Yeon-Il;Lee, Sang-Gil;Lee, Cheol-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.21-28
    • /
    • 2015
  • In the semi-conductor process, a simulation process is performed to detect defects by analyzing the behavior of the impurity through the physical quantity calculation of the inner element. In order to perform the simulation, Finite-Difference Time-Domain(FDTD) algorithm is used. The improvement of semiconductor which is composed of nanoscale elements, the size of simulation is getting bigger. Problems that a processor such as CPU or GPU cannot perform the simulation due to the massive size of matrix or a computer consist of multiple processors cannot handle a massive FDTD may come up. For those problems, studies are performed with parallel/distributed computing. However, in the past, only single type of processor was used. In GPU's case, it performs fast, but at the same time, it has limited memory. On the other hand, in CPU, it performs slower than that of GPU. To solve the problem, we implemented a computing model that can handle any FDTD simulation regardless of size on the cluster which consist of heterogeneous processors. We tested the simulation on processors using MPI libraries which is based on 'point to point' communication and verified that it operates correctly regardless of the number of node and type. Also, we analyzed the performance by measuring the total execution time and specific time for the simulation on each test.

Thermal Conductivity Measurement of Ge-SixGe1-x Core-Shell Nanowires Using Suspended Microdevices (뜬 마이크로 디바이스를 이용한 Ge-SixGe1-x Core-Shell Nanowires 의 열전도율 측정)

  • Park, Hyun Joon;Nah, Jung hyo;Tutuc, Emanuel;Seol, Jae Hun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.10
    • /
    • pp.825-829
    • /
    • 2015
  • Theoretical calculations suggest that the thermoelectric figure of merit (ZT) can be improved by introducing a core-shell heterostructure to a semiconductor nanowire because of the reduced thermal conductivity of the nanowire. To experimentally verify the decrease in thermal conductivity in core-shell nanowires, the thermal conductivity of Ge-SixGe1-x core-shell nanowires grown by chemical vapor deposition (CVD) was measured using suspended microdevices. The silicon composition (Xsi) in the shells was measured to be about 0.65, and the remainder of the germanium in the shells was shown to play a role in decreasing defects originating from the lattice mismatch between the cores and shells. In addition to the standard four-point current- voltage (I-V) measurement, the measurement configuration based on the Wheatstone bridge was attempted to enhance the measurement sensitivity. The measured thermal conductivity values are in the range of 9-13 W/mK at room temperature and are lower by approximately 30 than that of a germanium nanowire with a comparable diameter.

Oribicularis Oris Muscle Defects in Philtral Deformities in the Repaired Cleft Lip (구순열 수술 후 인중의 변형과 구륜근 결손)

  • Kim, Suk-Wha;Jeong, Yeon-Woo;Cheon, Jung-Eun;Park, Chan-Young;Oh, Myung-June;Kim, Jung-Hong;Choi, Tae-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.427-432
    • /
    • 2010
  • Purpose: The purpose of this study is to estimate muscle defect by ultrasonography in the patients with secondary deformities of the lip. We investigated the association between the muscle defect in the repaired cleft lip and the philtral appearance not only at resting state but also maximal puckering. Methods: From December 2006 to November 2007, 52 children were evaluated after primary or secondary cheiloplasty. Digital photographs were taken both from the front and both three quarter views in repose and at maximal pucker. Video clips were also taken in repose and at maximal pucker. A panel of four, scored the philtral ridge and dimple seen on these photographs and videos by using two visual analog scales. Eminence of the philtral ridge was scored by a 5 point grading scale, from "conspicuous groove" to "normal philtral ridge" and the philtral dimple was scored by 3 point grading scale, from "no dimple" to "prominent dimple". Ultrasound images of the upper lip were made using a linear array transducer at the resting position of the lip and evaluated by a single radiologist. Results: The philtral ridge eminence scored $2.79{\pm}0.54$ and $1.40{\pm}0.53$ at resting and maximal pucker, correlating with "flat" and "conspicous groove". The philtral dimpling scored $1.44{\pm}0.53$ and $2.27{\pm}0.66$ at resting and maximal pucker, correlating with "no dimple" and "slight dimple". Ultrasound imaging showed the average muscle dehiscence to be $3.78{\pm}2.14$ mm at resting position. Correlation between the muscle defect in ultrasound imaging and philtral ridge eminence at rest was statistically significant (p<0.050), but was not significant (p=0.756) at maximal pucker using Spearman's rank correlation. Correlation between the muscle defect in ultrasound imaging and philtral dimpling was not statistically significant both at rest (p=0.920) and at maximal pucker (p=0.815) using Spearman's rank correlation. Conclusion: Quantitative assessment of the muscle defect using ultrasonography correlates with the static philtral appearance, but does not correlate with the dynamic appearance. Also, the size of the muscle defect does not show any correlation with the philtral dimpling. Our findings reveal that ultrasound imaging partially reflect static appearance of philtrum but cannot reflect dynamic appearance and suggest the need for further research to evaluate dynamic appearance.

Assessment of Attenuation Correction Techniques with a $^{137}Cs$ Point Source ($^{137}Cs$ 점선원을 이용한 감쇠 보정기법들의 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyoung;Park, Yun-Young;Park, Hae-Joung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.57-68
    • /
    • 2005
  • Purpose: The objective of this study was to assess attenuation correction algorithms with the $^{137}Cs$ point source for the brain positron omission tomography (PET) imaging process. Materials & Methods: Four different types of phantoms were used in this study for testing various types of the attenuation correction techniques. Transmission data of a $^{137}Cs$ point source were acquired after infusing the emission source into phantoms and then the emission data were subsequently acquired in 3D acquisition mode. Scatter corrections were performed with a background tail-fitting algorithm. Emission data were then reconstructed using iterative reconstruction method with a measured (MAC), elliptical (ELAC), segmented (SAC) and remapping (RAC) attenuation correction, respectively. Reconstructed images were then both qualitatively and quantitatively assessed. In addition, reconstructed images of a normal subject were assessed by nuclear medicine physicians. Subtracted images were also compared. Results: ELEC, SAC, and RAC provided a uniform phantom image with less noise for a cylindrical phantom. In contrast, a decrease in intensity at the central portion of the attenuation map was noticed at the result of the MAC. Reconstructed images of Jaszack and Hoffan phantoms presented better quality with RAC and SAC. The attenuation of a skull on images of the normal subject was clearly noticed and the attenuation correction without considering the attenuation of the skull resulted in artificial defects on images of the brain. Conclusion: the complicated and improved attenuation correction methods were needed to obtain the better accuracy of the quantitative brain PET images.