• Title/Summary/Keyword: point bending

Search Result 1,243, Processing Time 0.026 seconds

The effect of temperature changes on force level of superelastic nickel-titanium archwires (온도 변화가 교정용 니켈-티타늄 호선의 하중값에 미치는 영향)

  • Chun, Kyoung-Ae;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.432-439
    • /
    • 2007
  • The purpose of this study was to evaluate the influence of intraoral temperature changes on the orthodontic force level of a superelastic nickel-titanium alloy wire. Methods: Nickel-titanium archwires of $0.016"{\times}0.022"$ thickness were tested with a three point bending test setup, and temperature changes were applied. The force level changes according to temperature changes were measured at a 1.5 mm deflection during the loading phase and a 1.5 mm deflection during the unloading phase from a deflection to 3.1mm. Ten cycles of thermal cycling from baseline $(37^{\circ}C)$ to cold $(20^{\circ}C)$ or hot $(50^{\circ}C)$temperature were applied. Results: Alter thermal cycling, the force level during the loading phase decreased and the force level during the unloading phase increased even after the temperature was changed to the initial $37^{\circ}C$. Conclusions: The results suggest that the orthodontic force level can not return to the initial force level after temperature changes. When applying superelastic nickel-titanium archwires, we must consider that a lighter force than the loading force and a heavier force than the unloading force will be applied after intraoral temperature changes caused by eating and drinking.

THE AGING EFFECT Of K3B/IM7 IN $80^{\circ}C$ WATER

  • Kim Hyungwon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.31-34
    • /
    • 2005
  • Hygrothermal aging of the laminates of $Avimid^{R}$ K3B/IM7 in $80^{\circ}C$ water was studied as a function of immersion time prior to forming microcracks. The factors causing the $80^{\circ}C$ water to degradation of the laminates could be the degradation of the matrix toughness, change in residual stresses or interfacial damage between the fiber and matrix. The times to saturation in $80^{\circ}C$ water for the laminates and the neat resin are 100 hours and 500 hours. After 500 hours aging of the neat resin in $80^{\circ}C$ water, the glass transition temperature was changed less than $1\%$ by DSC test and the weight gain was $1.55\%$ increase. After 500 hours aging, the fracture toughness of the neat resin was decreased about $37\%$ by 3-point bending test. After 100 hours aging of the [+45/0/-45/90]s K3B/IM7 laminates in $80^{\circ}C$ water, the weight gain was $0.41\%$ increase. The $80^{\circ}C$ water diffusion rate into the neat resin was faster than into the laminates. In 100 hours, the loss of the microcracking toughness of the laminates was $28\%$ of the original toughness by our own microcracking fracture toughness criterion.

  • PDF

Fracture Behavior and Crack Growth of Concrete by The Nonlinear Fracture Mechanics (비선형 파괴역학에 의한 콘크리트의 파괴거동과 균열성장에 관한 연구)

  • 배주성;나의균
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.2
    • /
    • pp.81-92
    • /
    • 1990
  • Concrete, a mixed material, has heterogeniety, anisotrophy and nonlinearity. Therefore, in its 'racture analysis, it is more reasonable to evaluate its fracture toughness by applying the concept of 'racture mechanics rather than the strength concept. Up to the present the concepts of fracture mechanics which were applied to concrete have been divided into two main classes. The one is the concept of linear elastic fracture mechanics and the other is the concept of elastic-plastic fracture mechanics. But it has been pointed out that there are many problems and irrationalities in applying the concept of linear elastic fracture mechanics to concrete. In this study, the J -integral method and the COD method mainly used in the analysis of nonlinear fracture mechanics, were introduced and the three point bending test was carried out for investigating the effects of the variation of the maximum aggregate size and notch depth on the fracture behavior and the crack growth of concrete, and the relationships of fracture energy and crack opening displacement. According to the results of this study the more the maximum aggregate size and the notch depth increased, the more the nonlinearity of load-deflection behavior was remarkable. The increase of the coarse aggregate size created the more ductility of concrete. Thus concrete showed the more stable fracture. As for the path of the crack growth, the more the coarse aggregate size increased, the more it was irregulary deviated from the straight line but it was not almost affected by the variation of the notch depth. Also, the fracture energy increased according as the coarse aggregate size increased and the notch depth decreased.

The study of Mobile Robot using Searching Algorithm and Driving Direction Control with MAV (초소형비행체를 이용한 자율이동로봇의 경로탐색 및 방향제어에 관한 연구)

  • 김상헌;이동명;정재영;김관형
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09b
    • /
    • pp.105-119
    • /
    • 2003
  • 일반적인 로봇시스템은 자신이 이동해야 할 목표 지점을 자율적으로 생성할 수 없으므로 어떤 다른 시스템의 정보를 이용하여 주변을 탐색하거나 장애물을 인식하고 식별하여 자신의 제어전략을 수립한다. 그러므로 본 논문에서 제시한 시스템은 초소형 비행체를 이용하여 주위 환경과 자율 이동로봇의 위치 정보를 탐색할 수 있도록 시스템을 구성하였다 이러한 시스템의 성능은 로봇이 위치하고 있는 주위의 불완전한 정보로부터 적절한 결론을 유도해 낼 수 있어야 한다. 그러한 비선형적인 문제는 현재까지도 문제 해결을 위해 많은 연구가 진행되고 있다. 본 연구에서는 자율이동로봇의 행동 환경을 공간상의 제약을 받지 않는 비선형 시스템인 초소형 비행체에 극초단파(UHF16채널) 영상장치를 이용하여 호스트 PC로 전송하고 호스트 PC는 로봇의 현재 위치, 이동해야 할 목표위치, 장애물의 위치와 형태 등을 분석한다. 분석된 결과 파라메타는 RF-Module을 이용해서 로봇에 전송하고, 로봇은 그 데이터를 분석하여 동작하게 된다. 로봇이 오동작 또는 장애물로 인해 정확한 목적지까지 도달하지 못할 때 호스트 PC는 새로운 최단경로를 생성하거나 장애물을 회피 할 새로운 전략을 로봇에게 보내준다. 본 연구에 적용한 알고리즘은 초소형 비행체에서 탐지한 불완전한 영상정보에서도 비교적 신뢰도 놀은 결과를 보이는 A* 알고리즘을 사용하였다 적용한 알고리즘은 실험을 통하여 실시간으로 정보를 처리할 수 있었으며, 자율 이동로봇의 충돌회피나 최단 경로 생성과 같은 문제를 실험을 통하여 그 성능과 타당성을 검토하였다.delta}textitH]$를 도출하였다.rc}C$에서 30 ㎫의 압력으로 1시간동안 행하였다 소결한 시편들은 직사각형 형태로 가공하였으며 표면은 0.5$\mu\textrm{m}$의 다이아몬드 입자로 연마하였다. XRD, SEM 및 TEM을 이용하여 상분석 및 미세조직관찰을 행하였다. 파괴강도는 3중점 굽힘 법으로 (3-point bending test) 측정하였다. 이때 시편 하부의 지지 점간의 거리는 30mm, cross-head 속도는 0.5 mm/min으로 하였고 5개의 시편을 측정하여 평균값을 구하였다.ell/\textrm{cm}^3$, 혼합재료 3은 0.123$\ell/\textrm{cm}^3$, 0.017$\ell/\textrm{cm}^3$, 혼합재료 4는 0.055$\ell/\textrm{cm}^3$, 0.016$\ell/\textrm{cm}^3$, 혼합재료 5는 0.031$\ell/\textrm{cm}^3$, 0.015$\ell/\textrm{cm}^3$, 혼합재료 6은 0.111$\ell/\textrm{cm}^3$, 0.020$\ell/\textrm{cm}^3$로 나타났다. 3. 단일재료의 악취흡착성능 실험결과 암모니아는 코코넛, 소나무수피, 왕겨에서 흡착능력이 우수하게 나타났으며, 황화수소는 펄라이트, 왕겨, 소나무수피에서 다른 재료에 비하여 상대적으로

  • PDF

FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO PLATFORM WIDTH OF FIXTURE (임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석)

  • Chung Kyung-Min;Chung Chae-Heon;Jeong Seung-Mi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.674-688
    • /
    • 2003
  • Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.

Evaluation of Fracture Toughness for Steel Fiber Reinforced High Strength Concrete by Non-linear Fracture Mechanics Parameter(J-integral) (비선형 파괴역학 파라메터(J-적분)에 의한 강섬유보강 고강도콘크리트의 파괴인성 평가)

  • Koo, Bong Kuen;Kim, Tae Bong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.25-37
    • /
    • 1993
  • This paper describes the use of the J-integral, a one parameter of the non-linear fracture mechanics(NLFM), as a means to measure toughness of steel fiber reinforced concrete. This parameter can be conveniently evaluated from experimentally determined load-deflection curves from flexural tests when a maximum-load failure criterion is employed. And, for high strength concrete which was reinforced steel fiber, with two different fiber length in the form of notched beams, were tested under 3-point bending, and $J_{IC}$, as well as the linear elastic fracture mechanics(LEFM) parameters $K_{IC}$ and $G_{IC}$ were evaluated. The results suggest that $J_{IC}$ is a promising fracture criterion for all of these. while $K_{IC}$(or $G_{IC}$) almost certainly are not. Also it was found that a fiber addition of less than 0.5% did not improve the fracture toughness of the high strength concrete. However, at more than 1.0% in fiber contents, $J_{IC}$ showed significant increases. reflecting the changed character of the concrete; $K_{IC}$ and $G_{IC}$ did not.

  • PDF

Study on the Nonlinear Electromagnetic Acoustic Resonance Method for the Evaluation of Hidden Damage in a Metallic Material (금속 재료의 잠닉손상 평가를 위한 비선형 전자기음향공진 기법에 관한 연구)

  • Cho, Seung-Wan;Cho, Seung-Hyun;Park, Choon-Su;Seo, Dae-Cheol;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.277-282
    • /
    • 2014
  • Recently, much attention has been paid to nonlinear ultrasonic technology as a potential tool to assess hidden damages that cannot be detected by conventional ultrasonic testing. One nonlinear ultrasonic technique is measurement of the resonance frequency shift, which is based on the hysteresis of the material elasticity. Sophisticated measurement of resonance frequency is required, because the change in resonance frequency is usually quite small. In this investigation, the nonlinear electromagnetic acoustic resonance (NEMAR) method was employed. The NEMAR method uses noncontact electromagnetic acoustic transducers (EMATs) in order to minimize the effect of the transducer on the frequency response of the object. Aluminum plate specimens that underwent three point bending fatigue were tested with a shear wave EMAT. The hysteretic nonlinear parameter ${\alpha}$, a key indicator of damage, was calculated from the resonance frequency shift at several levels of input voltage. The hysteretic nonlinear parameter of a damaged sample was compared to that of an intact one, showing a difference in the values.

Effect of Saw-Damage Etching Conditions on Flexural Strength in Si Wafers for Silicon Solar Cells (태양전지용 실리콘 기판의 절삭손상 식각 조건에 의한 곡강도 변화)

  • Kang, Byung-Jun;Park, Sung-Eun;Lee, Seung-Hun;Kim, Hyun-Ho;Shin, Bong-Gul;Kwon, Soon-Woo;Byeon, Jai-Won;Yoon, Se-Wang;Kim, Dong-Hwan
    • Korean Journal of Materials Research
    • /
    • v.20 no.11
    • /
    • pp.617-622
    • /
    • 2010
  • We have studied methods to save Si source during the fabrication process of crystalline Si solar cells. One way is to use a thin silicon wafer substrate. As the thickness of the wafers is reduced, mechanical fractures of the substrate increase with the mechanical handling of the thin wafers. It is expected that the mechanical fractures lead to a dropping of yield in the solar cell process. In this study, the mechanical properties of 220-micrometer-solar grade Cz p-type monocrystalline Si wafers were investigated by varying saw-damage etching conditions in order to improve the flexural strength of ultra-thin monocrystalline Si solar cells. Potassium hydroxide (KOH) solution and tetramethyl ammonium hydroxide (TMAH) solution were used as etching solutions. Etching processes were operated with a varying of the ratio of KOH and TMAH solutions in different temperature conditions. After saw-damage etching, wafers were cleaned with a modified RCA cleaning method for ten minutes. Each sample was divided into 42 pieces using an automatic dicing saw machine. The surface morphologies were investigated by scanning electron microscopy and 3D optical microscopy. The thickness distribution was measured by micrometer. The strength distribution was measured with a 4-point-bending tester. As a result, TMAH solution at $90^{\circ}C$ showed the best performance for flexural strength.

A Study on Buckling Characteristics of 2-way Grid Single-Layer Domes Considering Rigidity-Effect of Roofing Covering Materials (지붕마감재 강성효과를 고려한 2방향 그리드 단층돔의 좌굴특성에 관한 연구)

  • Park, Sang-Hoon;Suk, Chang-Mok;Jung, Hwan-Mok;Kwon, Young-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.2 no.1 s.3
    • /
    • pp.85-92
    • /
    • 2002
  • Two way grid single-layer domes are of great advantage in fabrication and construction because of the simple fact that they have only four members at each junction. But, from a point of view of mechanics, the rectangular latticed pattern gives rise to a nonuniform rigidity-distribution in the circumferential direction. If the equivalent rigidity is considered in the axial direction of members, the in-plane equivalent shearing rigidity depends only on the in-plane bending rigidity of members and its value is very small in comparison to that of the in-plane equivalent stretching rigidity. It has a tendency to decrease buckling -strength of dome considerably by external force. But it is possible to increase buckling strength by the use of roofing covering materials connected to framework. In a case like this, shearing rigidity of roofing material increases buckling strength of the overall structure and can be designed economically from the viewpoint of practice. Therefore, the purpose of this paper, in Lamella dome and rectangular latticed dome that are a set of 2-way grid dome, is to clarify the effects of roofing covering materials for increasing of buckling strength of overall dome. Analysis method is based on FEM dealing with the geometrically nonlinear deflection problems. The conclusion were given as follows: 1. In case of Lamella domes which have nearly equal rigidity in the direction of circumference, the rigidity of roofing covering materials does not have a great influence on buckling-strength, but in rectangular latticed domes that has a clear periodicity of rigidity, the value of its buckling strength has a tendency to increase considerably with increasing rigidity of roofing covering materials 2. In case of rectangular latticed domes, as rise-span-ratio increases, models which is subjected to pressure -type-uniform loading than vertical-type-uniform loading are higher in the aspects of the increasing rate of buckling- strength according to the rate of shear reinforcement rigidity, but in case of Lamella dome, the condition of loading and rise-span-ratio do not have a great influence on the increasing rate of buckling strength according to the rate of shear reinforcement rigidity.

  • PDF

Effects of Wearing between Respirators and Glasses Simultaneously on Physical and Visual Discomforts and Quantitative Fit Factors (안면부 여과식 방진마스크와 안경 동시 착용 시 불편감과 밀착계수 비교)

  • Eoh, Won Souk;Choi, Youngbo;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.52-60
    • /
    • 2018
  • This study compares the differences of the fit factor by the order of wearing preference between Particulate filtering facepiece respirators(PFFR) and glasses when participants wore simultaneously and a survey of physical and visual complaint. Recognition level about fit of respirators was investigated and the educational (before- and after-) effect of the fit factor. When participants wore PFFR and glasses, physical complaints were nose pressure, slipping, nose and ear pressure, ear pressure and rim loosen, the most highly physical complaints were nose pressure. Visual complaints were demister, blurry vision, dizziness, visual field, and lens dirty, the most highly visual complaints were demister. But, there was significant difference in physical complaint such as nose pressure(10.3%), slipping (23.0%), nose and ear pressure(14.3%), and rim loosen(16.2%), visual complaint such as visual field(13.8%) and lens dirty(32.4%). For the recognition of fit of respirators, respirators fitness, leak site, an initial point and an object, faulty factor, recognition level was higher. Fit factor was increased after education of proper wearing of respirator. Change of the fit factor was smaller compared to the normal breathing and after 6 actions in case of after education. Questionnaire consisted of general characteristics and physical/visual complaint, recognition of fit. Complaints were measured after the QNFT with multiple choices. Quantitative fit factor was measured by device and compared the result of (before- and after-) educational effect. Also, we selected to 6 actions (Normal breathing, Deep breathing, Bending over, Turning head side to side, Moving head up and down, Normal breathing) among 8 actions OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The fit factor was higher after the training (p=0.000). Descriptive statistics, paired t-test, and Wilcoxon analysis were performed to describe the result of questionnaire and fit test. (P=0.05) Therefore, it is necessary to investigate the quantitative research such as training program and glasses fitting factor about the wearing of PFFR and glasses simultaneously.