• Title/Summary/Keyword: plus construction

Search Result 161, Processing Time 0.028 seconds

Diagnostic Analysis and Influential Factors of CM Fee Estimation (CM 대가 산정방식의 문제점 분석에 대한 연구 -문화예술회관 사례를 중심으로-)

  • Yoo, Byeong-Gi;Jung, Chan-Young;Kim, Jae-Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.6
    • /
    • pp.132-140
    • /
    • 2006
  • On December, 1996, Construction Management(CM) was introduced in Korean construction industry due to its managerial efficiency proven in the international construction industries. However, It have had serious problems with many regulations, standards, manuals and details of practices considering its constituents and industry conditions. Especially, there were controversial points in the CM fee estimate; difference between the fee on the owner's view point and that from contractor's that impedes appropriate CM services. Therefore, this paper is to analyze public construction projects into Cm fee calculation such as fee as a percent of construction cost, cost plus fixed fee and contract price, and analyzed what is irrationality and why irrationality is made. So it makes a contribution to a study on standards for paper CM fee calculation.

An Application Analysis of Renewable Energy for Public Building and an Analysis of Building Energy Substitution Rate (공공건축물의 신재생에너지 적용분석 및 건물에너지 분담률 분석)

  • Kang, Su-Hyun;Yu, Si-Wan;Hwang, Jung-Ha;Cho, Young-Hum
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.348-353
    • /
    • 2011
  • Recently the renewable energy has been used widely and the importance of renewable sources is bigger than before. So the government enforced a law to the public buildings to install the renewable energy facilities. The capacity of facilities is 5% of total construction cost until April 13, 2011. Since then, the government changed the law from 5% of total construction cost to 10% of predicted energy usage because of the practical use of the renewable energy facilities. So, in this study, the comparative analysis is conducted according to the law to the building installed PV system through the EnergyPlus simulation.

  • PDF

Fundamental Rearch to Prepare a Direction to Improve the Design Fee Standard through Case Analysis (사례분석을 통한 설계대가 기준 개선 방향 마련 기초연구)

  • Han, Jae Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.179-180
    • /
    • 2020
  • In the budgeting guidelines, there are rules for calculating design fee and direct costs. However, only the design fee is calculated excluding the direct cost, which causes the cost to be insufficient. Therefore, this study is designed to analyze representative cases where direct costs are insufficient, draw out problems, and propose a way to improve design fees.

  • PDF

The Establishment of Improvement Direction through Case Analysis of Cost Standards in Overseas Construction Engineering (해외 건설엔지니어링분야 대가기준 사례분석을 통한 개선방향 마련)

  • Ko, Hyun A;Han, Jae Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.165-166
    • /
    • 2020
  • The standard for the cost calculation in the field of domestic construction engineering can be largely divided into the construction cost ratio method and the actual cost addition method. However, the standard for calculating the cost of the construction cost ratio method is a trend to switch to the actual cost addition method due to limitations such as not reflecting the characteristics of the construction. Therefore, this study aims to derive implications by investigating and analyzing examples of cost standards in the field of overseas construction engineering, such as the United States, and deriving directions for improvement in domestic cost standards in the future.

  • PDF

Analysis of Construction Condition and Environmental Effect of Deep Soil Mixing (심층혼합처리 공법의 시공조건 및 환경적 영향 분석)

  • Cho, Jin-Woo;Lee, Yong-Soo;Yu, Jun;Shin, Won-Jae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1155-1158
    • /
    • 2006
  • This paper presents a study on the construction condition and environmental effect of deep soil mixing. Construction condition means the difference in unconfined compressive strength with respect to the depth and location of samples. Environmental effect means alkalinity diffused from soil stabilizer. The experimental results indicate that the unconfined compressive strength vary with respect to the depth, and doesn't show consistency pattern. So, in field application we must decide a mixing ratio enough to satisfy the least unconfined compressive strength. The difference in unconfined compressive strength with respect to the location of samples is negligible. The generation of alkalinity from soil stabilizer is reduced by permeating in non-improved soil and it is expected that the diffusion of alkalinity has no environmental effect on soil and ground water.

  • PDF

Improvement of Fibrinolytic Activity of Bacillus subtilis 168 by Integration of a Fibrinolytic Gene into the Chromosome

  • Jeong, Seon-Ju;Park, Ji Yeong;Lee, Jae Yong;Lee, Kang Wook;Cho, Kye Man;Kim, Gyoung Min;Shin, Jung-Hye;Kim, Jong-Sang;Kim, Jeong Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.11
    • /
    • pp.1863-1870
    • /
    • 2015
  • Fibrinolytic enzyme genes (aprE2, aprE176, and aprE179) were introduced into the Bacillus subtilis 168 chromosome without any antibiotic resistance gene. An integration vector, pDG1662, was used to deliver the genes into the amyE site of B. subtilis 168. Integrants, SJ3-5nc, SJ176nc, and SJ179nc, were obtained after two successive homologous recombinations. The integration of each fibrinolytic gene into the middle of the amyE site was confirmed by phenotypes (Amy-, SpecS) and colony PCR results for these strains. The fibrinolytic activities of the integrants were higher than that of B. subtilis 168 by at least 3.2-fold when grown in LB broth. Cheonggukjang was prepared by inoculating each of B. subtilis 168, SJ3-5nc, SJ176nc, and SJ179nc, and the fibrinolytic activity of cheonggukjang was 4.6 ± 0.7, 10.8 ± 0.9, 7.0 ± 0.6, and 8.0 ± 0.2 (U/g of cheonggukjang), respectively at 72 h. These results showed that construction of B. subtilis strains with enhanced fibrinolytic activities is possible by integration of a strong fibrinolytic gene via a marker-free manner.

Construction of an Ultra High Vacuum Molecular Beam Epitaxy System and Optical Property of ZnSe/GaAs(001) Epitaxial films (초고진공 분자선 에피성장 시스템의 제작과 에피성장된 ZnSe/GaAs(001)의 광학특성)

  • Kim, Eun-Do;Son, Young-Ho;Eom, Gi-Seog;Cho, Seong-Jin;Hwang, Do-Weon
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.458-464
    • /
    • 2006
  • The construction and the performance test of an ultra high vacuum (UHV) molecular beam epitaxy (MBE) system has been completed successfully. We have done domestic development and tried performance test for ultra high vacuum molecular beam epitaxy system. This system has reached pressure $2X10-^{10}$ Torr and the substrate has reached temperature $1,100^{\circ}C$. We have investigated into the characteristic of ZnSe/GaAs(001) by using scanning electron microscope (SEM), atomic force microscope (AFM), x-ray diffraction (XRD) and photolumi-nescence (PL).

The analysis of the renewable energy supply ratio for the school building applied PV system (PV 시스템이 설치된 대학건물의 전력 생산에 따른 신재생에너지 공급비율 분석)

  • Kang, Su-Hyun;Lee, Yong-Ho;Hwang, Jung-Ha;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.50-57
    • /
    • 2012
  • Recently the renewable energy has been used widely and the importance of renewable sources is bigger than before. And the government enforced a law to the public buildings to install the renewable energy facilities. The capacity of facilities was 5% of total construction cost until April 13, 2011. Since then, the government changed the law from 5% of total construction cost to 10% of predicted energy usage for the resonable use of the renewable energy facilities. In this study, the comparative analysis is conducted according to the law to the building installed PV system through the Energy Plus simulation. And the method for improving renewable energy supply ratio was analyzed using existing PV array. Adjusting the PV array angle is the best way to generate more electric power without additional fee. When applying the month optimum angle, 3,600kWh of electric power are more generated compared to the existing angle.

Development of a Renewable Energy Facility Design and Its Simulation Case Study (신재생에너지 설비 설계방안 개발 및 시뮬레이션 사례 연구)

  • Shin, Younggy;Kim, Eun Joo;Kim, Tae Hyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.464-470
    • /
    • 2013
  • Economic feasibility was conducted regarding the regulation that dictates obligatory installation of renewable energy facilities in small proportion. A concern is how to allocate the capacities of candidate facilities (solar collectors, PV cells and geothermal heat pumps) with minimum cost, and meet the obligatory energy supply proportion. A design rule has been developed, with which a designer can tune his or her design strategy between installation cost and LCC. This was derived mainly from documents regarding the KEMCO installation guide. It was concluded that PV was the cheapest, with respect to installation cost, but a geothermal heat pump was the most recommended, when LCC was also taken into account. The proposed design result was also confirmed, by simulation results obtained from Energy Plus.

Analyzing Defects Types and Causes of Activities in Information and Communication Works Based on Investigation (정보통신공사 하자관리 실태조사를 통한 세부 공종별 하자 유형 및 원인 분석)

  • Eom, Yong-Been;Sohn, Sung-Geun;Kang, Sang-Hun;Park, Hyun Jung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.269-270
    • /
    • 2021
  • As the era of the Fourth Industrial Revolution arrives and the culture of contact-less was established due to the long-term COVID-19, the construction industry is striving to develop smart home services to expand the scope of information and communications technology (ICT) to provide convenience to residents. However, various defects are occurring in information and communications technology facilities in apartments, and related research is lacking. In this study, case studies and research methods of related prior studies are analyzed as a basis for identifying the types and causes of defects that occur in information and communications technology facilities. To analyze various studies, we divided them into studies on smart home Internet of Things (IoT), information and communications technology construction of apartments, and investigated their features and limitations. Plus, future research will be conducted on apartments within 10 years of completion among apartments completed by domestic construction companies to supplement the limitations of prior research. In addition, we will prepare basic data on defects of ICT construction by analyzing the major causes of defect types through the analysis of defect types and frequency by detailed work type of information and communications technology construction.

  • PDF