• 제목/요약/키워드: plumbing system

검색결과 53건 처리시간 0.028초

곡관 종류에 따른 배수관내의 소음 저감에 관한 실험적 연구 (Experimental Study on the Noise Reduction of Drainage Pipe by a kind of Curve Pipe)

  • 김정훈;심동혁;김경훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.187-192
    • /
    • 2006
  • The effect where the multiple sound arrest ing goes mad to the human being does the zone. From like that cotton, this dissertation the both sides flag executed the research regarding a sound arresting reduction in the object in one example. It compared the piping structure which generally is space-time and a specific piping structure and it tested and research and the modeling regarding a sound arresting reduction the simulation which leads and it executed result and comparison of existing it analyzed. The duplication where the reduction effect is bigger the result general VG2 piping structure than escape it did with the fact that it appears the large effect the piping structure which it connects. Also, the straight pipe effect of multiple sound arresting could not go mad with the fact that.

  • PDF

안전성평가연구소 정읍제2안전성평가시험연구동 설계사례 (A Case Study on the Design for Jeong-eup Second Safety Evaluation Tentative Research Institute)

  • 정종림;오근환;정재훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.552-557
    • /
    • 2008
  • This paper introduces to schematic design for Korea Institute of Toxicology Second Campus at Jeong-eup and provides fundamental information and data in order to design this laboratory facility to meet the criteria of G.L.P(Good Laboratory Practice), AAALAC(Association for Assessment and Accreditation of Laboratory Animal Care) and so on. This paper especially focus on design criteria, HVAC(Heating Ventilating and Air Conditioning) equipment and systems, plumbing equipment and systems, maintenance of equipment and systems and energy saving system of this laboratory facility.

  • PDF

스프링클러 동배관의 공식부식 발생원인 (Investigation on Causes of Pitting Corrosion in Sprinkler Copper Tubes)

  • 이재봉;정호석
    • Corrosion Science and Technology
    • /
    • 제13권1호
    • /
    • pp.6-14
    • /
    • 2014
  • Copper metal is widely used in tubes installed in sprinkler water services because of its excellent corrosion resistance. Copper corrosion is considered to be insignificant in water system and the incident of copper pipeline failure is relatively low. However, pitting corrosion is a major problem with all copper tubes. In this study, leaked sprinkler copper tubes were collected from three different locations and examined on the causes of pitting corrosion of copper tubes in sprinkler water plumbing systems. Electrochemical tests such as potentiodynamic polarization, as well as surface and chemical analyses were performed. Results show that pitting corrosion of copper tubes were found as Type I pitting that the carbon film formed on the copper tubes have a harmful effects, causing the pinhole failure in the pipe and resulting in leakage of water. The contermeasures on Type I pitting corrosion of copper tubes were proposed.

효과적인 포인트 클라우드 기반 건축 MEP 파이프 객체 역설계 처리를 위한 시스템 아키텍처 (System Architecture for Effective Point Cloud-based Reverse Engineering of Architectural MEP Pipe Object)

  • 강태욱
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5870-5876
    • /
    • 2014
  • 본 연구의 목적은 효과적인 건축 MEP(Mechanic, Electric and Plumbing) 파이프 객체 역설계 자동화를 위한 시스템 아키텍처를 제안하고, 프로토타입 개발을 통해 역설계 기술에서 향후 개선할 점을 도출하는 것이다. 이를 위해 역설계 작업에 필요한 요구사항, 유스케이스, 기능 및 클래스를 도출하였다. 도출된 기능을 바탕으로 건축 MEP파이프 객체 역설계를 위한 아키텍처를 설계하였으며, 시스템의 정적 구조, 알고리즘을 설계하였다. 제안된 시스템 아키텍처를 기반으로 한 프로토타입 개발 연구를 통해 향후 개선할 점을 도출하였으며, 일반적인 파이프 유형은 RANSAC(RANdom SAmple Consensus)등 일반적인 역설계 방법으로 처리가 가능하지만, 이형 파이프와 대용량 데이터 처리를 위한 공간 인덱싱 기반 LOD(Level Of Detail)기법이 별도로 고려될 필요가 있다는 것을 확인하였다.

DEFORMATION OF AUGUSTINE VOLCANO, ALASKA, 1992-2006, MEASURED BY ERS AND ENVISAT SAR INTERFEROMETRY

  • Lee, Chang-Wook;Lu, Zhong;Kwoun, Oh-Ig
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.582-585
    • /
    • 2006
  • Augustine volcano is an active stratovolcano located southwest of Anchorage, Alaska. Augustine volcano experienced seven significantly explosive eruptions in 1812, 1883, 1908, 1935, 1963, 1976, and 1986, and a minor eruption in January 2006. To measure ground surface deformation of Augustine volcano, we applied satellite radar interferometry with ERS-1/2 and ENVISAT SAR images acquired from three descending and three ascending satellite tracks. Multiple interferograms are stacked to reduce artifacts due to changes in atmospheric condition and retrieve temporal deformation sequence. For this, we used Least Square (LS) method for reducing atmospheric effects and Singular Value Decomposition (SVD) method for the retrieval of a temporal deformation sequence. Interferograms before 2006 eruption show about 3 cm/year subsidence by contraction of pyroclastic flow deposits from the 1986 eruption. Interferograms during 2006 eruption do not show significant deformation around volcano crater. Interferograms after 2006 eruption show again a several cm subsidence by compaction and contraction of pyroclastic flow deposits for a few months. This study demonstrates that satellite radar interferometry can monitor deformation of Augustine volcano to help understand the magma plumbing system driving surface deformation.

  • PDF

급수관에서 관재에 따른 부식특성과 미생물 재성장 고찰 (Influence of Pipe Materials on Corrosion and Bacteria Regrowth in A Model Home Plumbing System)

  • 김태현;이윤진;이환;이철효;안교철;이우식
    • 한국환경과학회지
    • /
    • 제16권1호
    • /
    • pp.121-128
    • /
    • 2007
  • This study performed in order to evaluate the effects of pipe materials on corrosion and bacteria regrowth using a laboratory scale batch test. Two varieties of feed water with different microbial conditions were selected: tap water, surface river water (Han River water), and five pipe materials; carbon steel, copper, galvanized iron, stainless steel, and PVC, Carbon steel and galvanized iron pipes showed higher corrosion rates than other materials. In terms of attached bacterial growth, pipes with PVC and stainless steel showed higher bacteria concentration compared to other materials. Pseudomonas vesicularis was the predominant bacteria found on biofilm. The behavior of bacterial growth in the pipes was observed using a scanning electron microscope.

Design, Fabrication, and Testing of a MEMS Microturbine

  • Jeon Byung Sun;Park Kun Joong;Song Seung Jin;Joo Young Chang;Min Kyoung Doug
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.682-691
    • /
    • 2005
  • This paper describes the design, fabrication, and testing of a microturbine developed at Seoul National University. Here, the term 'microturbine' refers to a radial turbine with a diameter on the order of a centimeter. Such devices can be used to transmit power for various systems. The turbine is designed using a commercial CFD code, and it has a design flow coefficient of 0.238 and work coefficient of 0.542. It has 31 stator blades and 24 rotor blades. A hydrodynamic journal bearing and hydrostatic thrust bearings counteract radial and axial forces on the rotor. The test turbine consists of a stack of five wafers and is fabricated by MEMS technology, using photolithography, DRIE, and bonding processes. The first, second, fourth, and fifth layers contain plumbing, and hydrostatic axial thrust bearings for the turbine. The third wafer contains the turbine's stator, rotor, and hydrodynamic journal bearings. Furthermore, a turbine test facility containing a flow control system and instrumentation has been designed and constructed. In performance tests, a maximum rotation speed of 11,400 rpm and flow rate of 16,000 sccm have been achieved.

중앙난방방식을 지역난방과 소형열병합난방 방식으로 전환 시 경제성 비교 분석 (Analysis of the Economic Efficiency of the District Heating and Gas Engine Co-Generation System Compared with the Central Heating System)

  • 김규생
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.544-551
    • /
    • 2015
  • This study was conducted to determine the LCC of apartment complexes with district heating and a cogeneration system. For the purpose of analyzing LCC according to the size of the apartment complex, 500, 1,500, and 4,000-unit model apartments were selected. Analysis was performed on the design of the heating system and the life cycle cost including total construction cost, maintenance and operation cost for the duration of the project period (15 years). According to the calculated results, 1) The initial cost of the cogeneration system for 500, 1,500, and 4,000-unit apartments is higher than that of the district heating system by 20%, 13%, and 12%, respectively. 2) In the case of the cogeneration system, the payback period by electric generation was found to be 5.21, 4.92 and 4.47 years, and saving cost was calculated to be 29 billion won, 94 billion won and 262 billion won after the payback period for 500, 1,500, and 4,000-unit apartments, respectively. 3) The LCC values of the cogeneration system were 1.12, 1.07 and 1.06 times larger than those of the district system according to the size of the apartment complex. In this study, the district heating system was found to be more efficient than the cogeneration system in terms of LCC reduction. 4) District heating is affected by fuel bills, so energy efficiency should be improved through recovering waste heat (incineration heat, etc.). Also, district cooling should be provided according to heat use to keep the temperature high in winter and low in summer.

콤팩트형 태양열/지열히트펌프 하이브리드 냉난방 및 급탕 시스템 개발 및 성능분석 (The Development and Performance Analysis of Compact Type Solar Thermal/Ground Coupled Heat Pump Hybrid System for Heating, Cooling and Hot water)

  • 백남춘;정선영;윤응상;이경호
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.59-67
    • /
    • 2012
  • In this study,the compact type solar thermal and ground coupled heat pump hybrid system for space heating/cooling and hot water supply has been developed. This hybrid system was installed in Zero Energy Solar House(ZeSH) in KIER for the demonstration. The thermal performance and operational characteristics of this hybrid system were analysed especially. The results are as follows. (1) This hybrid system was designed in order to address the existing disadvantages of solar thermal/ground coupled heat pump system. For this design, all parts except solar collector and ground coupled heat pump were integrated into a single product in a factory. The compact type unit includes two buffer tanks, an expansion tank, pumps, valves, a controller, etc. This system has an advantage of easy installation with simple plumbing work even in narrow space. (2) The thermal charging and discharging time of the buffer tanks and its characteristics by ground coupled heat pump, and heat pump COP according to geo-source temperature and buffer storage temperature have been studied. This system was found to meet well to the heat load without any other auxiliary heating equipment. (3) The operating hours of the ground coupled heat pump as a backup device of solar thermal can be reduced significantly by using solar heat. It was also found that the minimum heating water supply setting temperature and maximum cooling water supply setting temperature make an influence on the heat pump COP. The lower heating water and the higher cooling water temperature, the higher COP. In this respect, the hybrid system's performance can be improved in ZeSH than conventional house.

AHP 분석을 통한 공동주택 안전 및 안심생활 수준 향상에 관한 연구 (A Study on the Improvement of the Safety and Safe Living Standards of Apartment Houses through AHP Analysis)

  • 지영일;신승하;최병정
    • 한국재난정보학회 논문집
    • /
    • 제17권2호
    • /
    • pp.289-305
    • /
    • 2021
  • 연구목적: "AHP 분석을 통한 공동주택 입주민의 안전 및 안심생활 수준 향상"을 위하여 상위계층과 sub 상위계층, 하위대안 요소의 중요도 및 안심생활을 위한 요인을 확인하며, 종합우선도를 확인하고자 한다. 연구방법: 본 연구에서는 공동주택 유지보수 및 제도에 관한 선행연구와 전문가 자문을 토대로 안전관리 평가요소 및 대안을 계층 구조화하였다. 연구 모형은 전문가를 상대로 쌍대비교 구성의 설문에 활용하고, 대체안 순위 결정 등을 위해 AHP분석 기법을 사용 하였다. 연구결과: 설문조사 응답 결과는 일관성을 확보하였고, 연구의 최종 목표 달성을 위해 sub상위계층 그리고 대안을 상대적 가중치 비교 등을 분석한 결과 상위계층은 공동주택 전기설비 안전점검, sub 상위계층은 안전점검/정밀점검/진단평가, 대안은 급·배수시설이 최우선적으로 중요한 것으로 확인되었다. 결론: 공동주택관리 전문가의 관리자적 시각으로 볼 때 급·배수시설, 방범안전, 전기안전이 최우선적인 대안으로 나타났다. 이는 생활안전사고의 중요성을 확보하고 안심생활의 수준 향상이 가능한 것으로 의사 결정되어 사전 예방 및 관리 강화의 대안임을 보여 주었다.