• 제목/요약/키워드: plumbing system

검색결과 53건 처리시간 0.033초

층상배관 배수시스템의 소음 특성 평가 (Noise Characteristics of Plumbing System with Wall Hanging Unit)

  • 박철용;김상훈;장동운
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1421-1424
    • /
    • 2006
  • Recently Requirement of indoor environment is increased in APT. Among indoor noises of APT, noise of plumbing system in bathroom is very serious problem except of floor impact noise. Plumbing system with wan hanging unit make a good grade and recognition in rating noise of bathroom in grade of house rating. But it is hard to find a data which are measured in APT built. In this study, the effect of noise reduction is checked by measuring the noise of plumbing system with wall hanging unit that is built. As result the upper household's Peak sound level is measured 80dB(A), the under household's peak sound level is measured 40dB(A).

  • PDF

Identification of target subjects and their constraints for automated MEP routing in an AEC project

  • Park, SeongHun;Shin, MinSo;Kim, Tae wan
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.776-783
    • /
    • 2022
  • Since Mechanical, Electrical, and Plumbing(MEP) routing is a repetitive and experience-centered process that requires considerable time and human resources, if automated, design errors can be prevented and the previously required time and human resources can be reduced. Although research on automatic routing has been conducted in many industries, the MEP routing in AEC projects has yet to be identified due to the complexity of system configuration, distributed expertise, and various constraints. Therefore, the purpose of this study is to identify the target subjects for MEP routing automation and the constraints of each subject. The MEP design checklist provided by a CM company and existing literature review were conducted, and target subjects and constraints were identified through process observation and in-depth expert interviews for five days by visiting a MEP design company. The target subjects were largely divided into six categories: air conditioning plumbing, air conditioning duct, restroom sanitary plumbing, heating plumbing, and diagram. The findings from interviews show that work reduction and error reduction has the greatest effect on air conditioning plumbing while the level of difficulty is the highest in air conditioning duct and restroom sanitary plumbing. Major constraints for each subject include preventing cold drafts on air conditioning pipes, deviation in ventilation volume in air conditioning ducts, routing order on restroom sanitary plumbing, and separation distance from the wall on heating plumbing. In this way, subjects and constraints identified in this study can be used for MEP automatic routing.

  • PDF

신경망 알고리즘을 이용한 버터플라이 밸브의 위치제어 (Position Control System using Neural Network Algorithm for Butterfly Valve)

  • 최정주
    • 한국기계가공학회지
    • /
    • 제11권5호
    • /
    • pp.94-98
    • /
    • 2012
  • Butterfly valves are usually used by the plumbing systems in plant engineering field. Valves are used for controlling the flow rate and pressure of fluid. In order to control the flow rate using butterfly valve, the position control of valve disc should be designed. However, since there are lots of uncertain disturbance in plumbing system, the robust control system should be considered. Therefore, the sliding mode control system using neural network algorithm is proposed in this paper. The proposed control system provides the estimating method using neural network for the unmeasurable disturbance in the plumbing system. The performance of the proposed control system is evaluated through computer simulations.

노후 아파트의 바닥충격음 및 급·배수 소음 저감방안에 관한 연구 (A Study on the Reduction Method of Heavy-weight floor impact sound and Plumbing noise in Decrepit Apartment houses)

  • 주문기;한명호;오양기
    • KIEAE Journal
    • /
    • 제9권2호
    • /
    • pp.99-106
    • /
    • 2009
  • The noise in apartment buildings are major factor that determine the quality of indoor noise environment. Particularly, the noise from children's running footsteps and plumbing noise have caused the residents who live in decrepit apartment houses to uncomfortable environment. And as time go by, sound performance are getting worse according to the aging of the facilities. So this study deals with the plans to improve the sound performance of decrepit apartment house. To compare the noise reduction, we measured the heavy-weight impact sound level and plumbing noise level before and after changes the measurement conditions. As the results of measurements, the heavy-weight impact sound level were decreased when stiffness reinforcement were installed on slab. Especially the sound level were decreased 2.1-7.6dB in 50-80Hz of low frequency range. Instead of PVC pipe system, cast iron pipe and triple elbow drain pipe systems were installed. Noise level were decreased 15dB(A) in 250Hz. Noise level of pipe system's on the slab is less than under slab one. On the contrary water saving stool showed increasing the noise level.

초고층 건축물의 위생설비 시스템 설계 (Sanitary Plumbing System Design of High-rise Building)

  • 주덕훈;변운섭;윤해동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.491-496
    • /
    • 2009
  • Recently, the high-rise building has been constructed competitively because it is symbol of the national competitive power including the technical power. The higher buildings are getting, the more important building mechanical systems are. So, the building mechanical systems are getting developed. Among the building mechanical systems, the sanitary system is basically necessary in order to maintain the building hygienically along with convenience and safety. This study has been investigated for various cases of high-rise building plumbing system. As a result, a variety of zoning method has been applied to most skyscrapers depending on the building height in the building mechanical system. And a variety of joint have been applied to minimize the Shortening and Sway. Also, the drainage in same uses has been discharged outside of a build through the one vertical pipe line. And airing system has been used like Individual Vent Pipe Yoke Vent Pipe Stack Vent Pipe Loop Vent Pipe Relief Vent Pipe method. It is sure that this study could be used as the high-rise building design.

  • PDF

BIM 기반 MEP 설계 조율 프로세스 분석을 통한 비용 관리 시스템 개발 사례 연구 (Cost Management System for Mechanical, Electrical, and Plumbing(MEP) Coordination Using Building Information Modeling(BIM) - A Case Study)

  • 원종성;함성일;장세준
    • 한국건축시공학회지
    • /
    • 제22권2호
    • /
    • pp.195-205
    • /
    • 2022
  • 본 연구에서는 BIM(building information modeling)을 활용한 비용 기반 MEP(mechanical, electrical, and plumbing) 조율 프로세스를 제안하였다. 제안된 프로세스는 MEP 부재간 간섭 해결뿐만 아니라 MEP 조율 과정에서 의사결정에 따른 MEP 관련 비용 변화를 정확하고, 빠르게 분석하고, 참여자와 공유할 수 있도록 해준다. 이를 위하여 MEP BIM 모델로부터 추출된 물량 정보와 비용 데이터베이스, 시간 정보를 통합했다. 제안된 프로세스의 적용성을 평가하기 위하여 국내 건설 프로젝트 현장에 적용하였다. 적용 결과, 예상 비용 대비 약 1.6%의 MEP 관련 비용을 절감했다고 분석되었다.

급수배관에서의 순간최대 급수량의 산정에 대한 비교 연구 (A Comparison of the Design Loads of a Water Supply System)

  • 이용화
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.38-41
    • /
    • 2014
  • Fixture units and the diversity curve are used, in order to determine the required size of water supply pipe. However, the values of the National Plumbing Code, International Plumbing Code and National Standard Plumbing Code of America are not the same. The objective of this study is to comparatively analyze the fixture units and the peak flows of a 10th story office building, at any instant of time, according to the three codes.

지속가능형 공동주택 구현을 위한 건식온돌 이중바닥 시스템 개발 (A study on development of dry ondol access floor system for sustainable apartment)

  • 오진균;손장열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.689-689
    • /
    • 2010
  • Since the apartment was built by Korea National Housing Cooperation in 1961, the amount of its supply has been increased greatly, especially from the late 70's. Recently there are many ongoing studies regarding sustainable construction apartment in Korea, one of the research is developing sustainable apartment that has longer life cycle. Also according as life's quality of residents is upgrading, complain for impact noise and plumbing system noise from upstair or downstair are increasing more and more. To solve this complains, government established impact noise standard as lightweight impact noise of 58dB, heavyweight impact noise of 50dB and presented standard floor system or recognition floor system to satisfy this impact noise standard. So in this study, the aim is to develop dry ondol access floor system for sustainable apartment which have pleasant and quiet life environment.

  • PDF

화장실 배수관에 따른 배수소음 평가 (Rating of Noise Emission by Plumbing system in Bathroom)

  • 정진연;이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.923-927
    • /
    • 2003
  • The aim of this study is to investigate the characteristics and quantity of the noise reduction by pipe material, wrapped pipe with glass wool and installed pipe height The characteristics of noise emission from drain-pipes is as follows. The noise reduction pipe in PVC can reduce noise levels in 7-10㏈ and the cast-iron pipe can reduce in 14㏈compared with the normal PVC pipe. In these days, the glass wool was used for preventing the burst and the noise reduction. But the glass wool for wrapping pipe is not effective to the noise reduction. The characteristics of noise emission from various installed pipe height were measured As the ceiling space of the remodeled building was raised, the noise level was troubled by increasing of the vertical pipe length.

  • PDF