전기투석에 의한 니켈도금 폐수처리 공정에서 한계전류밀도와 불균질 이온교환막의 재생 (The Limiting Current Density and the Regeneration of a Heterogeneous Ion Exchange Membrane in a Nickel Plating Rinse Waters Treatment Process by Electrodialysis)

  • 윤용수
    • 환경위생공학
    • /
    • 제16권2호
    • /
    • pp.38-46
    • /
    • 2001
  • In this work, the heterogeneous ion exchange membrane was used in a electrodialysis apparatus to treat a Ni planting rinse water because the heterogeneous ion exchange membrane was excellent efficiency as compared with low manufacturing cost, was easy to make, and had a good mechanical properties. For a regeneration of membrane and to obtain the optimal condition for a scale-up of apparatus after treating Ni plating rinse water, we would find about the limiting current density and the concentration polarization. When the Ni plating rinse water 150mg/L was treated with the electrodialysis apparatus using the heterogeneous ion exchange membrane, the limiting current density was about $1.49{\;}mA/\textrm{cm}^2$. And the limiting current density increased with the flow rate and concentration of Ni plating rinse water. We recognized that the used membrane could be reused by periodic backwashing because efficiency was constant when the membrane was backwashed after treating wastewater.

  • PDF

Preparation of Water Soluble Chitosan Blendmers and Their Application to Removal of Heavy Metal ions from Wastewater

  • Seo, Sang-Bong;Toshio Kajiuchi;Kim, Dae-In;Lee, Soon-Hong;Kim, Hak-Kil
    • Macromolecular Research
    • /
    • 제10권2호
    • /
    • pp.103-107
    • /
    • 2002
  • High purity water soluble chitosans (WsCs) were employed as a flocculant to remove heavy metal ions from wastewater of industrial plating wastewater treatment complex. Their weight average molecular weights and polydispersities were 272,000~620,000 g/mol and 1.4~1.9 range, respectively and were readily soluble in water in the pH range of 3~11. Heavy metal ions such as chromium, iron and copper were removed well by WsCs. When WsCs was blended with either sodium N, N-diethyldithiocarbamate trihydrate (SDDC$_{T}$) or sodium salicylate (SSc), the removal efficiency was further increased primarily due to the excess amount of hydrophilic sulfonic and carboxylic groups. Especially, in the case of WsCs-SSc the remaining chromium and copper concentrations were 0.1 mg/L and 9.5 mg/L, which are 1/15 and 1/3 compared with that of pure WsCs, respectively. The former is within the acceptable limit, but the latter is not. Therefore, the effective copper flocculant remains to be studied.d.

도금폐수내 유리시안과 착염시안 및 중금속의 처리특성 (I) (Treatment Characteristics of Plating Wastewater Containing Freecyanide, Cyanide Complexes and Heavy Metals (I))

  • 정연훈;이수구
    • 한국물환경학회지
    • /
    • 제25권6호
    • /
    • pp.979-983
    • /
    • 2009
  • The mean pH of wastewater discharged from the plating process is 2, so a less amount of alkali is required to raise pH 2 to 5. In addition, if sodium sulfite is used to raise pH 5 to 9 in the secondary treatment, caustic soda or slaked lime is not necessary or only a small amount is necessary because sodium sulfite is alkali. Thus, it is considered desirable to use only $FeSO_4{\cdot}7H_2O$ in the primary treatment. At that time, the free cyanide removal rate was highest as around 99.3%, and among heavy metals, Ni showed the highest removal rate as around 92%, but zinc and chrome showed a low removal rate. In addition, the optimal amount of $FeSO_4{\cdot}7H_2O$ was 0.3g/L, at which the cyanide removal rate was highest. Besides, the free cyanide removal rate was highest when pH value was 5. Of cyanide removed in the primary treatment, the largest part was removed through the precipitation of ferric ferrocyanide: $[Fe_4(Fe(CN)_6]_3$, and the rest was precipitated and removed through the production of $Cu_2[Fe(CN)_6]$, $Ni_2[Fe(CN)_6]$, CuCN, etc. Furthermore, it appeared more effective in removing residual cyanide in wastewater to mix $Na_2SO_3$ and $Na_2S_2O_5$ at an optimal ratio and put the mixture than to put them separately, and the optimal weight ratio of $Na_2SO_3$ to $Na_2S_2O_5$ was 1:2, at which the oxidative decomposition of residual cyanide was the most active. However, further research is required on the simultaneous removal of heavy metals such as chrome and zinc.

폐산화철촉매에 의한 도금폐수중 크롬이온 회수에 관한 기초연구 (A study on the recovery of chromium from metal-plating wastewater with spent catalyst)

  • 이효숙;오영순;이우철
    • 자원리싸이클링
    • /
    • 제13권2호
    • /
    • pp.9-15
    • /
    • 2004
  • 석유화학공정으로부터 폐기되는 폐산화철촉매를 이용하여 도금합성폐수중 크롬회수에 관한 연구를 회분식과 연속식으로 실시하였다. 도금합성제수 중 $CrO _{4}^{-2}$ 형태의 음이온으로 존재하는 6가 크롬은 폐산화철촉매의 등전점(pH 3.0)이하에서 폐촉매와 물리적 흡착을 한다. 한편, 6가 크롬은 pH 3.0 이상에서도 폐촉매의 수산화철과 산화환원반응에 의해 일부 환원되어 $Cr(OH)_3$로 침전한다. 컬럼을 이용한 크롬 연속회수실험에서 크롬합성폐수의 pH가 0.5∼2.0일 때 폐촉매의 크롬흡착량은 2.0∼2.3g/L이며, pH가 3.0에서는 1.5g/L이었다. 폐수 중 크롬농도가 50∼500mg/L로 높아질수록 폐촉매에 흡착한 크롬누적량은 1.29∼8.56g/L로 증가하지만, 유속이 30∼80 ml/mm으로 증가하여도 크롬 흡착누적량은 2.21∼2.49 mg/L로 거의 유사하였다.

아연도금공정에서의 청정생산기술의 적용 및 평가 (Application and Evaluation of Cleaner Production Technology in Zinc Plating Process)

  • 이홍기;구석본
    • 청정기술
    • /
    • 제9권2호
    • /
    • pp.63-69
    • /
    • 2003
  • 도금산업은 제조 공정상 다량의 환경오염물질을 배출하는데 일반적으로 산 알칼리 폐수 뿐만아니라 크롬화합물, 시안화합물, 중금속류, 부식성물질, 독성물질 등이 발생하여 환경오염을 초래한다. 본 연구에서는 도금 산업에서 가장 환경오염부하가 크고 많이 적용하는 아연도금공정의 공정진단 및 분석을 통해 아연도금공정의 청정생산 실행효과가 큰 우선순위별 단위공정에 최적기술을 적용하여 현 도금공장의 열악한 근무환경과 환경오염을 개선하고자 하였다.

  • PDF

Operational conditions of electrochemical oxidation process for removal of cyanide (CN-) in real plating wastewater

  • Zhao, Xin;Jang, Minsik;Cho, Jin Woo;Lee, Jae Woo
    • Membrane and Water Treatment
    • /
    • 제11권3호
    • /
    • pp.217-222
    • /
    • 2020
  • An electrochemical oxidation process was applied to remove cyanide (CN-) from real plating wastewater. CN- removal efficiencies were investigated under various operating factors: current density and electrolyte concentration. Electrolyte concentration positively affected the removal of both CN- and Chemical Oxygen Demand (COD). As the electrolyte concentration increased from 302 to 2,077 mg Cl-/L, removal efficiency of CN- and COD increased from 49.07% to 98.30% and from 23.53% to 49.50%, respectively, at 10 mA/㎠. Current density affected the removal efficiency in a different way. As current density increased at a fixed electrolyte concentration, CN- removal efficiency increased while COD removal efficiency decreased, this is probably due to lowered current efficiency caused by water electrolysis.

페콘크리트의 중화 및 중금속 제거를 위한 재활용에 관한 연구 (I) (A Study on Recycle of Waste Concretes for Neutralization and Removal of Heavy Metals ( I ))

  • 김은호;김정권;성낙창
    • 한국환경과학회지
    • /
    • 제6권5호
    • /
    • pp.497-503
    • /
    • 1997
  • This study was performed to Investigate the utilization of waste concretes for neutralization and removal of heavy metals In plating wastewater, because waste concretes have been known to be very porous, to have high species surface area and to have alkaline minerals such as calcium. The results obtained from this research showed that waste concretes had a buffer capacity to neutralize an acidic alali system in plating wastewater. Generally, neutralization and removal rate of heavy metals were excellent in the increase of waste concrete amounts and a small size. Because a coefficient of correlation was high, it seemed that removal of heavy metals could be explained by Freundlich and Langmuir isotherms. If we reflected the adsorption capacity(k) and adsorption intensity(1/n) of Freundlich isotherm, we couldn't consider waste concretes as a good adsorbent. But, we could know that waste concretes were capable of removing a part of heavy metals. In point of building waste debris, if waste concretes substituted for a valuable adsorbent such as actuated carbon, they could look forward to an expected economical effect.

  • PDF

A study on Nickel Hydroxide Crystallization for Plating waste Treatment

  • Lee, Chang-Hwan;Lee, Choul-Ho
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.292-295
    • /
    • 2001
  • A Study on the precipitation characteristics of nickel hydroxide as well as carbonate and sulfide is carried out to determine the proper treatment condition of the wastewater induced from nickel-plating industry. The nickel concentrations in the effluent could be kept lower than 5ppm when the value of pH was maintained higher than 10. The precipitation of nickel salts by alkaline addition to the nickel containing model wastewater was conducted by using proper amount of sodium hydroxide, sodium carbonate, sodium bicarbonate and sodium sulfide. In case of the sulfide treatment, the residual nickel concentration in the clear water after precipitates removed showed the lowest value. The influences of the precipitation condition upon the particle size of the crystals precipitated were also investigated. In spite of the various precipitation conditions were adopted, the particle size of the precipitated crystals showed no great differences. The sedimentation rates of the precipitated particle bed were observed and the free sedimentation period was terminated within 20 minutes. Although the hindered sedimentation as well as bed compaction progressed subsequently, the bed heights were maintained almost the same level after two hours of sedimentation.

  • PDF

산화철 나노구조박막 이용한 도금폐수내의 시안제거 (Cyanide Degradation from Plating Wastewater Using Iron Oxide Nanocomposite Layer)

  • 장준원;김혜란;임형석;박재우
    • 한국물환경학회지
    • /
    • 제30권3호
    • /
    • pp.292-297
    • /
    • 2014
  • We synthesized the self-organized nanoporous oxide with potentiostatic anodization of iron foil. The iron oxide nanocomposite (INCs) were fabricated in 1M $Na_2SO_4$ containing 0.5wt% NaF electrolyte holding the potential at 20, 40 and 60 V for 20min, respectively. Field Emmision Scanning Electron Microscopy (FESEM) and X-ray Diffractometer (XRD) were used to evaluate the micromorphology and crystalline structure of INC film. Also, this study was performed to evaluate the fenton reaction using INC film with hydroperoxide for degradation of cyanide dissolved in water. In case of INC-40V in the presence of $H_2O_2$ 3%, the first-order rate constant was found to be $1.7{\times}10^{-2}min^{-1}$, and indicated to be $1.2{\times}10^{-2}min^{-1}$ on commercial hematite powder. This result is shown to be good performance enough to replace the powder type for treatment of wastewater.